• Title/Summary/Keyword: 전기설비

Search Result 9,128, Processing Time 0.036 seconds

A Study on Fault Location Estimation Technique Using the distribution Ratio of Catenary Current in AC Feeding System (전차선 전류 분류비를 이용한 교류전기철도 고장점 표정기법에 관한 연구)

  • Jung, Ho-Sung;Park, Young;Kim, Hyeng-Chul;Min, Myung-Hwan;Shin, Myong-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.5
    • /
    • pp.404-410
    • /
    • 2011
  • In AC feeding system, the fault location is calculated by using ratio of current absorbed in the neutral point of AT(Automatic Transformer) or by measuring reactance. In this way, however, an estimation error can be happened due to the many reasons. In addition, for measuring currents in the neutral point of AT, other measuring devices and communication equipments are additionally required. In order to solve the disadvantages, this paper suggests a novel technique using the distribution ratio of catenary current. The proposed technique uses existing protective relays and measures catenary current. With the measured data, we can calculate the distribution ratio of catenary current and determine fault location. Through the simulated results, we derived the correlation between current ratio and fault location. Using this technique, additional equipments and expenses can be reduced. Besides, fault location can be determined more correctly.

Calculation Method of Transient Potential Rises of Horizontal Ground Electrodes Depending on Injection Point of the Ground Current (접지전류의 입사점에 따른 정보통신설비용 수평접지전극의 과도전위상승 계산 방법)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.197-203
    • /
    • 2014
  • When the lightning current is injected to the ground system of information and communication facilities, analysis of the transient potential rise in the ground system is one of main factors to effectively design the ground system. The performance of grounding systems is normally estimated with the grounding impedance and the transient potential rise which represents the electrical characteristics of the grounding system. The method for calculating the grounding impedance depending on the injection point of the lightning current was proposed. The delta-gap source model was proposed to calculate the grounding impedance in the case that the lightning current is injected to the center of the horizontal ground electrode. A new program which is possible to apply the frequency-dependent soil parameters using the Debye model was developed, because a commercial program for analyzing the performance of the grounding system can not apply to the frequency-dependent soil parameters. The experiment was carried out to confirm the availability of the simulation results with the same condition. Finally, the transient potential rises of a horizontal ground electrode depending on the lightning current waveforms were analyzed by using the results of the grounding impedance which is associated with the frequency-dependent soil parameters.

EM Algorithm based Air Flow and Power Data classification Analysis (EM 알고리즘기반의 공기 유량 및 전력 데이터 분류 분석)

  • Shim, Jae-Ryong;Noh, Young-Bin;Jung, Hoe-kyung;Kim, Yong-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.551-553
    • /
    • 2016
  • Since air compressor, as an essential equipment used in the factory and plant operations, accounts for around 20% of the total domestic electricity consumption, a real time sensor data monitoring based analysis for electricity consumption reduction is important. In particular, flow rates and pressures of these monitored variables has a direct correlation with the power consumption. This paper proposes a method to identify if the measurement error of the flow rate sensor comes from the sensor measurement limit through bivariate classification analysis of the flow rate and power using the EM (Expectation and Maximization) Algorithm and show how to enable more accurate analysis by the correlation between the flow rate and power on the right-censored data.

  • PDF

Studies on the Application of Unit-inverter Parallel Operation to Sea-water Lift Pump in Power Plant (단위 인버터 병렬운전에 의한 발전소 해수펌크 적용)

  • 김수열;류홍우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • Due to the increase in capacity of auxiliary machinery in power plant, the importance of energy saving has been greatly emphasized. If the speed of fans or pumps is controlled in accordance with the variation of load, large electric energy can be saved. Large capacity inverter, 2MVA GTO inverter, has been developed by operating two of 1MVA unit inverters in parallel. The parallel operation of the unit inverter is accomplished through two output transformers of which the secondary windings are connected in series. The system is composed of one control cubicle, one rectifier cubicle and 2 unit inverter cubicles. This inverter system was applied to the sea water lift pump(SLP) driven by a 6.6KV 1500KW induction motor in Seo-Inchon power plant to save the electric energy. The parallel operation of inverters by 180 degrees apart in switching frequency helps to reduce the harmonic components.

A Study on the Development of the Problem Improvement Directions in Enhancing BIM Data Interoperability through IFC (IFC를 통한 BIM 데이터의 상호연동 시 문제점분석 및 개선방향 설정에 관한 연구)

  • Kim, Ji-Won;Ock, Jong-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.6
    • /
    • pp.88-98
    • /
    • 2009
  • Construction industries have increasingly utilized Building information Modeling (BIM) technologies. Interoperability - the capability for BIM data to run from one computer application to another in the life cycle of a project has become one of the principal research areas. Enhancing interoperability inevitably requires information structures that are standardized throughout the construction industries. As a candidate of the data exchange standard, Industry Foundation Classes (IFC) has been developed and several researches recently performed to measure its richness of digital data exchange. But doubts have been brought up whether IFC meets a sufficient level of interoperability since the research result revealed a number of cases of information misrepresentation and loss. This research presents the lessons learned from the interoperability tests of three widely used 3D design applications including Graphisoft's Archicad, Autodesk's Revit, and Bentley's Bentley Architecture. One building's architectural and structural design data were modeled with the three tools and exchanged through IFC respectively for interoperability test.

Design and Implementation of An Automatic Telemetering/Rate Notification System Using CDMA Mobile Communication Modules (CDMA 이동통신모듈을 이용한 원격자동검침 및 요금통보 시스템의 설계 및 구현)

  • Kang, Chang-Soon;Kim, Soo-Jeong;Ko, Eun-Young
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.7
    • /
    • pp.977-985
    • /
    • 2008
  • This paper is concerned with automatic telemetering system which reads the consumed quantity of electricity, gas, and piped water. The existing metering method such that a meterman visits households and directly reads meters can cause several problems, including violation of privacy and the possibility of criminal accident, as well the inefficiency in viewpoint of system operation and rate notification. In this paper, we propose a new automatic telemetering and rate notification system, in which the system reads several meters at remote locations and notifies the rates to the customer's cellular phone with short message service(SMS). The proposed system has been developed by using CDMA mobile communication modules and personal computers. This system can operate only with cellular communication network even without wired-internet facilities. In particular, the developed system can provide home security and convenience as well as cost reduction, and thus be applied to intelligent home networks.

  • PDF

Hazard Identification and Risk Assessment for the Use of Passenger Portable Electronic Devices (승객 휴대 전자기기 사용에 대한 위해요인 식별 및 리스크 평가)

  • Lim, In-Kyu;Kim, Mu-Geun;Kang, Ja-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.288-294
    • /
    • 2018
  • The entertainment system of the aircraft has changed its paradigm in the form of using passenger electronic devices instead of using a fixed monitor. This has simplified the on-board equipment while the risk of safety has increased with the electric charging of portable electronic devices. Unlike personal portable electronic devices that do not have a transmission function, the use of Wi-Fi enabled electronic devices(T-PED) is allowed and the battery is required to be charged in the cabin. In this study, we used the NASA Aviation Safety Reporting System to investigate the effects of changes in wireless environment and entertainment service. Based on this, we analyzed the risks of personal electronic devices by sharing event occurrence cases caused by in-flight electronic equipment or passenger portable electronic devices(especially smart phones) from the viewpoint of aircraft safety management. This analysis includes identification of potential hazards and risk assessment, and finally the strategies for risk mitigation for safe use of portable electronic devices are suggested.

Insulation Performance Analysis of Vulnerable Parts of Thermal Bridge and Condensation in Modular Buildings (모듈러 주택의 열교 및 결로 취약부위별 단열성능 분석)

  • Kim, Miyeon;Kim, Hyunggeun;Park, Jinchul
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.3
    • /
    • pp.31-39
    • /
    • 2021
  • The modular construction method is an off-site construction method using built-in structures from the manufacturing facilities. Modular construction is commonly applied to buildings which have relatively smaller and simpler structures than other types of buildings. Although modular building has emerged in the domestic construction industry as an alternative building strategy, previous researches on the environmental characteristics of modular building has not been comprehensively studied. Thus, this study empirically analyzed the insulation performance of thermal bridge and condensation parts of the modular buildings by using IR image analysis, Air-Surface Temperature Ratio method, and temperature difference ratio. The insulation performance analysis was conducted by comparing a modular building and a RC building in Seoul. The results shows that there was no significant difference between insulation performances of RC building and modular building. Furthermore

Economic Assessment on an Integrated system of Phosphoric Acid Fuel Cell and Organic Rankine Cycle (인산형 연료전지와 유기랭킨사이클 연계시스템에 대한 경제성 평가)

  • Kim, Deug Soo;Yoo, Hoseon
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.43-49
    • /
    • 2022
  • In this study, the operational characteristics of the 7.48 MW fuel cell power plant consisting of 17 units of 440 kW Phosphoric Acid Fuel Cell (PAFC) in operation since its commercial operation in December 2017 were explained and the heat recovery process of the plat using Organic Rankine Cycle (ORC)was simulated. The fuel cell system performance improvement and economic assessment were analyzed by calculating the amount of heat recovery and electric power available when connecting a 125 kW XLT Model ORC for hot water heat sources with 105℃, 40.8 t/h. The result of the study shows that integrating the 125 kW ORC to PAFC power plant would improve generating efficiency by about 0.6% through annually 851,472 kWh of electricity produced by ORC, and fuel cell and ORC integrated systems were calculated to have a 0.35% higher Internal Return Ratio and more Net Present Value of 1,249 million KRW than not installing ORC despite installation costs.

  • PDF

Standardization Analysis of 'NEC Article 690' for Photovoltaic Shutdown Technology (태양광(PV) 셧다운(Shutdown)기술 'NEC Article 690' 표준화 분석)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.171-176
    • /
    • 2022
  • The communication signal for quick cut-off specification is defined as "design to support fast cut-off requirements of all applicable photovoltaic(PV) systems" in NEC 2014, NEC 2017 or the corresponding UL standard regardless of the system configuration. On the other hand, if you look at the domestic regulations related to new and renewable energy, the standards, regulations, and guidelines set by each institution are general, or only the parts necessary for the institution are being established and operated. There are many insufficient points to apply these things to photovoltaic facilities, and there are cases where excessive facilities are installed according to the design, inspection standards of supervisors and inspection agencies, and the skill level of inspectors. The internationally accepted IEC standards deal with various facility standards in detail. In each European country, there are separate facility regulations based on IEC. In particular, the performance and safety of devices are dealt with in detail, and in the case of 'NEC Article 690' applied in North America such as the United States, each item is described in detail. Therefore, in this paper, we will look at the details of the PV shutdown technology that is currently used and applied internationally.