• Title/Summary/Keyword: 전극 전위

Search Result 580, Processing Time 0.024 seconds

Fabrication and Characterization of Gas-liquid Hybrid Reactor Equipped with Atmospheric Pressure Plasma (기-액 하이브리드 대기압 플라즈마 반응기 제작 및 특성 분석)

  • Kwon, Heoung Su;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.452-458
    • /
    • 2022
  • Three types of gas-liquid hybrid horizontal, vertical and needle-to-cylinder plasma reactors were fabricated. Through these reactors, a high-efficiency, eco-friendly cleaning concept that generates reactive active species generated in atmospheric plasma discharge and gas-liquid activation reaction of cleaning components through the potential difference within the electrode was presented. As a result of comparing the efficiency for cleaning performance, the needle-to-cylinder type reactor had the best characteristics. Through this study, it was confirmed that the gas-liquid hybrid atmospheric pressure plasma reactor has the potential to be applied to ultra-precision cleaning processes such as semiconductor processes.

Analysis of Trace Copper Metal at The Electrode Consisting of Carbon Nanotube using Stripping Voltammetry (벗김전압전류법을 이용한 카본나노튜브 전극에서의 구리 분석)

  • Choi, Chang-Kun;Jung, Young-Sam;Kim, Nack-Joo;Pak, Dae-Won;Chung, Kun-Yong;Kim, Lae-Hyun;Kwon, Yong-Chai
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.933-937
    • /
    • 2012
  • In the present study, we evaluate the sensitivity and optimal stripping voltammetry (SV) conditions of copper (Cu), which is one of the main trace heavy metals inducing the environmental contamination, using carbon nanotube (CNT) electrode. In addition, the reaction mechanism of stripping reaction of Cu is investigated. The electrochemical analyses such as squarewave stripping voltammetry (SWSV) and linear scan voltammetry (LSV) are used for the evaluations. As a result of that, the best SWSV conditions like squarewave amplitude of 15 mV, frequency of 60 Hz, deposition potential of -1.0V vs. Ag/AgCl and deposition time of 200s are determined with the measured Cu sensitivity of $1.824{\mu}A/{\mu}M$. As a driving force affecting the stripping reaction of Cu, surface reaction is more dominant one than diffusion. These results are compared with other reference results and it is confirmed that our suggested CNT electrode gives rise to better Cu sensitivity result than other references.

Development of Smart Multi-function Ground Resistivity Measuring Device using Arduino in Wind Farm (풍력 발전단지내 아두이노를 활용한 스마트 다기능 대지 고유 저항 측정 장치 개발)

  • Kim, Hong-Yong;Yoon, Dong-Gi;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.65-71
    • /
    • 2019
  • Conventional methods of measuring ground resistance and ground resistance field measurement are used to measure voltage drop according to the resistance value of the site by applying current by installing a constant interval of measurement electrode. If the stratified structure of the site site is unique, errors in boundary conditions will occur in the event of back acid and the analysis of the critical ground resistance in the ground design will show much difference from simulation. This study utilizes the Arduino module and smart ground measurement technology in the convergent information and communication environment to develop a reliable smart land resistance measuring device even if the top layer of land is unique, to analyze the land resistance and accumulate data to predict the change in the age of the land. Considering the topographical characteristics of the site, we propose a ground resistance measuring device and its method of measuring ground resistance so that the auxiliary electrode can be installed by correctly positioning the angle and distance in measuring ground resistance. Not only is ground resistance value obtained through electrodes installed to allow accurate ground resistance values to be selected, but it can also be used as a useful material for installing electrical facilities in similar areas. Moreover, by utilizing reliable data and analyzing the large sections of the site, a precise analysis of the site, which is important in ground design as well as construction cost, is expected to be used much in ground facility design such as potential rise.

Electrochemical Reduction of Carbon Dioxide Using Porous La0.8Sr0.2CuO3 Electrode (다공성 La0.8Sr0.2CuO3 전극을 이용한 이산화탄소의 전기화학적 환원 반응)

  • Kim, Jung Ryoel;Lee, Hong Joo;Park, Jung Hoon
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.247-255
    • /
    • 2014
  • $La_{0.8}Sr_{0.2}CuO_3$ powder with the perovskite structure was prepared as electrode catalyst using citrate method. Porous electrode was made with as-prepared catalyst, carbon as supporter and polytetrafluoroethylene (PTFE) as hydrophobic binder. As results of potentiostatic electrolysis with potential of -1.5~-2.5 V vs. Ag/AgCl in 0.1, 0.5 and 1.0 M KOH at 5 and $10^{\circ}C$ on the porous electrode, liquid products were methanol, ethanol, 2-propanol and 1, 2-butanol regardless reaction temperature, while gas products were methane, ethane and ethylene at $5^{\circ}C$, and methane, ethane and propane at $10^{\circ}C$ respectively. Optimal potentials for $CO_2$ reduction in the view of over all faradic efficiency were high values (-2.0 and -2.2 V) for gas products whereas low potential (-1.5 V) for liquid products regardless of concentration and temperature.

Fabrication of Gel-type Electrolyte for the Development of Reference Electrode for Sea Water and Application to Measuring Equipment for Total Residual Oxidants (해수용 기준전극 개발을 위한 겔 타입 내부전해질 제조 및 잔류염소 측정장치에의 적용)

  • Kim, Yu-Jin;Lee, Hae-Don;Kim, Dae-Won
    • Applied Chemistry for Engineering
    • /
    • v.28 no.2
    • /
    • pp.153-157
    • /
    • 2017
  • Gel type internal electrolytes were synthesized by varying hydroxyethyl-cellulose (HEC) amounts and their durability and conductivity were measured. The ionic conductivity decreased as the content of HEC increased thus the internal electrolyte containing more than 12% of HEC could not be used as a reference electrode. Based on durability test results, as the HEC amount decreased carrier density resulting in increasing of the amount of KCl coming out of the porous membrane. Therefore in order to use long time at ballast water treatment systems, we selected 10% HEC for gel type internal electrolyte. The resolution test for total residual oxidants (TRO) was carried out using the TRO sensor and the gel type reference electrode made of 10% HEC. A 50 mV potential was applied to the TRO sensor for 30 sec and changes in the current were measured. It was confirmed that the TRO concentrations ranging from 0 to 15 mg/L could be separated at salinity conditions of 0.2~30 PSU. The results indicated that the TRO concentration at sea water and at fresh water was successfully measured by the TRO sensor constructed with the reference electrode using gel-type internal electrolyte of HEC.

Preparations of SPE Electrocatalysts Modified with Polypyrrole and Its Application for PEMFC (폴리피롤로 개질된 SPE 전극촉매의 제조 및 PEMFC로의 응용)

  • Kim, Jung-Hoon;Oh, Seung-Duck;Kim, Han-Sung;Park, Jong-Ho;Han, Jung-Woo;Lee, Kang Taek;Joe, Yung-Il
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.118-124
    • /
    • 2005
  • In this study, a novel deposition method of Pt catalysts onto Nafion membranes modified with polypyrrole (PPy) has been proposed for PEMFC application. The PPy/Nafion composite membranes were fabricated by chemical polymerization of pyrrole using $FeCl_3$ and $Na_2S_2O_8$ as initiator. The proton conductivity and water uptake of the chemically prepared PPy/Nafion composites were investigated. The ionic conductivity and water uptake of PPy/Nafion composite membrane prepared with $Na_2S_2O_8$ were decreased with polymerization time of pyrrole. In the case of $FeCl_3$, the ionic conductivity was almost retained and the water uptake was decreased with polymerization time of pyrrole. When the Pt particle was deposited on PPy/Nafion composites membrane by chemical reduction of $H_2PtCl_6$, the Pt loading on Nafion membrane was enhanced by polypyrrole due to electronic conduction property. The performance evaluation with membrane electrode assembly composed of Pt/PPy/Nafion composite and diffusion electrode was carried out using a single cell. As a result of fuel cell test, current density of $569mA/cm^2$ at 0.3 V has been obtained for MEA contained with Pt/PPy/Nafion composite. This study shows that direct deposition of Pt catalysts on Nafion impregnated polypyrrole is a promising method to prepare thin catalyst layer for the PEMFC.

Pole-pole array electrical resistivity survey and an effective interpretational scheme of its data (2극법 전기비저항 탐사 자료의 효율적인 해석방법)

  • Cho Dong-Heng;Lee Chang Yourl;Jee Sang-Keun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.112-131
    • /
    • 2000
  • In spite of its many strong points, pole-pole electrode configuration is not often used for ground electrical resistivity survey except for bore hole survey as normal logging and for archaeological investigation. Above all, poor spatial resolution of pole-pole survey may be responsible for this. But recent experiences so far gained by the present authers lead them to think that pole-pole survey can be at least a viable means of reconnaissance survey in near-surface conductive environment and an effective interpretational scheme may augment its resolution. As well known, a response of any other electrode configuration is a linear combination of pole-pole responses. Based on this principle of linear superposition and the principle of reciprocity, the other 'responses' can be derived with simple additions and subtractions of pole-pole responses. Though such responses are not always correct due to the adverse effects of noises, combined with the potential decay curves, they can be helpful to interprete better pole-pole survey data especially in connection of the resolution. This can be comparable to the use of the first or second derivatives of gravity and magnetic intensity surveys.

  • PDF

Analysis of Voltaic Cell Described in the Science Textbooks of Secondary Schools (중·고등학교 과학 교과서에 제시된 볼타전지에 대한 문제점 분석)

  • Sin, Dong-Hyeok;Lee, Sang-Gwon;Choe, Byeong-Sun
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.363-377
    • /
    • 2002
  • The purpose of this study was to improve the problems of the voltaic cell described in the science textbooks of secondary schools. For this purpose, the contents of science textbooks which are related to the voltaic cell were analyzed and the problems which were not explained clearly by theorems were tried to be explained by experiments, and lastly sug-gestions were made toward the improvements regarding the voltaic cell in the science textbooks. The findings are that there are problems on the ways of ensuring whether the voltaic cell operates properly as a chemical battery, on the explanation of why the hydrogen bubbles form at the zinc electrode, on the cell potential, on the unification of the electrode terminology used, and on the mention of the current. Solutions to the problems except the cell potential were suggested. According to the experiment, the theoretical potential was calculated by considering the potentials of redox reactions at the two electrodes of the cell and by taking into account the characteristics of the electrodes such as the work function, ionization energy, stan-dard reduction potential, and electronegativity.The cell potential of the voltaic cell is explained by several factors. In the improved version of the textbook's introduction section to the voltaic cell, it is necessary to describe the voltaic cell his-torically.For the conceptual section, it should be explained in terms of the Daniel cell.

Studies of Magnesium-Eriochrome Black T Complex in Acetonitrile (Acetonitrile에서의 Mg-EBT$^-$ 착물에 관한 연구)

  • Doo Won Park;Won Hyung Choi;Heung Lark Lee
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.4
    • /
    • pp.256-261
    • /
    • 1973
  • Complex formation of magnesium-Eriochrome Black T at constant ionic strength and hydrogen ion concentration have been studied spectrophotometrically in acetonitrile solution. The measured pH values were calibrated with standard buffer solutions by using a glass electrode Ag/0.1M $AgNO_3$ reference electrode couple. The results are as follows;$E_{glass}=716+59.1\;logA_{H+}[mv]$+(in mv. vs. Ag reference electrode for picric acid $-10^{-3}M$ tetramethylammonium picrate buffer), and $E_{glass}=1,193+59.1\;logA_{H+}[mv]$(in mv. vs. Ag reference electrode for 1,3-diphenylguanidine $-3{\times}10^{-3}M $ 1,3-diphenylguanidine perchlorate buffer). The acid dissociation exponent of ligand, $ pK_{H,EBT-}$was found to be 9.1. The conditional formation constants of $MgEBT^{-}$complex by log-ratio method were 3.97 (when m = 2) and 5.02 (when m = 1) as $log K_n$, respectively, for the reaction of $H_mEBT^{(3-m)-} + Mg^{2+} {\leftrightarrow}MgEBT^{-} + mH^{+}$. The present study showed that$MgEBT^{-}$ has the composition of 1:1 which agrees with the result of Schwarzenbach et al. in aqueous solution.

  • PDF

Effects of Electrolyte Cation on Electrochemical Properties of Negative and Positive Electrodes in Aluminum-Air Batteries (알루미늄-공기 전지의 음극 및 양극의 전기화학적 특성에 미치는 전해질 양이온의 영향)

  • Lee, Seunghwan;Yoon, Sungjae;Choi, Weon-Kyung;Baeg, Changhyun;Jeong, Soon-Ki
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.2
    • /
    • pp.134-141
    • /
    • 2022
  • To improve the performance of aluminum-air batteries, it is very important to understand the effect of electrolytes on the electrochemical properties of electrodes. In this study, the effects of electrolyte cations on the electrochemical redox reactions proceeding at the negative and positive electrodes were investigated using electrolytes having the same anion but different cations such as NaCl, LiCl, CaCl2, and ZnCl2. It was confirmed by discharge test, scanning electron microscopy and X-ray diffraction analysis that electrolyte cations affect the discharge potential and specific capacity of the electrode. Precipitates were formed on the surface of the positive electrode by Ca2+ and Zn2+ ions, resulting in degradation of the performance of the positive electrode. In addition, Ca2+ ions passivated the negative electrode and accelerated the performance degradation. This suggests that the positive ions of the electrolyte have different effects on the electrochemical performance of the positive and negative electrodes.