• Title/Summary/Keyword: 적정 투과율

Search Result 37, Processing Time 0.028 seconds

Selection to the Optimal Windows Transmittance of Office Building on Sky Conditions (천공상태에 따른 오피스 창호의 적정 투과율 선정)

  • 임오연;김병수
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.225-232
    • /
    • 2003
  • The purpose of this study is to select the optimal and minimum transmittance for visual amenity in office buildings. This study progressed as follows. The first, we select 5 films with various transmittance based on the current film makers whose films being used on the windows of office building nowadays and the case study of construction. And then we choose 6 kinds of transmittance as evaluation object including plain glass. The second, we made a mock-up models having different transmittance on the southern windows with model of real scale office building. The third, we select 17 pairs of adjectives for the evaluation of visual comfort on interior or exterior conditions with transmittance factor. The fourth, subjective evaluation experiment was done using selected evaluation adjectives and the result was analyzed. The results are as follows : the minimum transmittance appropriate for the office building is 30%∼40% and the optimal transmittance range is 40%∼60%.

Optimal Windows Transmittance by Energy Performance Analysis and Subjective Evaluation in office building (에너지성능분석 및 감성평가에 의한 오피스 창호의 적정 투과율 선정)

  • Kim, Byoung-Soo;Kim, Jung-Shin;Yim, Oh-Yon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.73-83
    • /
    • 2004
  • The purpose of this study is to select the optimal transmittance rate of windows in office buildings through subjective evaluation and energy performance analysis(computer simulation program ; DOE 2.1E). The results are as follows ; 1) In the subjective evaluation experiment, minimum transmittance of the glass is GE 30% and LT 70%, but the optimal transmittance rate is concluded in $40%\sim60%$. 2) As a result of the energy performance analysis, it is desirable for the building of consumptive with mainly air-conditioning to make transmittance as 40-60%. 3) Comparing foreign study on minimum and optimal transmittance rate is $25%\sim38%$, the minimum transmittance of this study is almost the same. But for the optimal transmittance rate, 20% more is needed for KOREAN.

Effects of Shading Rate and Method of Inside Air Temperature Change in Greenhouse (차광율 및 차광방법이 온실내부의 온도변화에 미치는 영향)

  • 이석건;이현우;김길동;이종원
    • Journal of Bio-Environment Control
    • /
    • v.10 no.2
    • /
    • pp.80-87
    • /
    • 2001
  • This study was conducted to provide basic data for the design of shading facility of greenhouse. The proper distance between external shading screen and roof surface, transmissivity of shading materials, and shading effects of external and internal shadings were analyzed. About a distance of 10 cm between inclined external shading screen and roof surface was enough to guarantee the external shading effect in the greenhouse without roof vent. The inside temperature of greenhouse installed with 85% internal shading screen was lower the maximum of 4$^{\circ}C$ and mean of 2$^{\circ}C$ than that with 55% internal shading screen in both natural ventilation and no ventilation condition. The difference of soil temperature between shading and no shading greenhouse was great, but the difference by shading rate or shading method was small. The performance of external shading for controlling inside temperature down was superior to that of the internal shading. The externally inclined shading screen parallel to the roof surface of greenhouse was more effective than the externally horizontal shading screen in controlling inside temperature of greenhouse without roof vent.

  • PDF

Effect of Side Openings and Greenhouse Width on the Natural Ventilation Performance (측창 및 온실 폭이 자연환기 성능에 미치는 영향)

  • Hyun Woo Lee;Young Hoe Woo;Jong Won Lee
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.25 no.1
    • /
    • pp.14-19
    • /
    • 2023
  • In summer, the natural ventilation performance for varying greenhouse width is very important in the glasshouses for year round cultivation. The effect of the side openings and greenhouse width on natural ventilation performance was analyzed by simulation. The necessary ventilation rate with different solar radiation transmittance increased significantly when the outside temperature grows higher. The necessary ventilation rate of 40% transmittance was about half of that of 90% transmittance. In consequence, shading effect on temperature control in greenhouse is significant in summer. When the total area of the openings for ventilation is constant, the maximum ventilation rate happens when the area of roof openings is equal to the area of side openings. This maximum ventilation rate is about 3 times of that of the greenhouse with roof openings and without side openings. Therefore, the side openings are advantageous to improve the natural ventilation in greenhouses. As the greenhouse width increases, the influence of side openings on the ventilation rate is becoming smaller. If the natural ventilation rate of the greenhouse with roof and side openings is to become double of that of the roof openings only, the width should be narrower than 38.4m for the Venlo type and 64m for Wide span type.

Effects of Shading Rate and Method on Inside Air Temperature Change in Greenhouses (차광율 및 차광방법이 온실내부의 온도변화에 미치는 영향)

  • 이현우;이석건;김길동;이종원
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.27-28
    • /
    • 2001
  • 온실의 차광설계에 필요한 기초자료를 제시하기 위하여 온실모형과 실험온실을 이용하여 외부차광재의 적정 설치간격 분석, 차광재별 광투과율 분석, 차광율에 따른 온실내부온도의 변화 분석, 차광이 온실내부의 지온변화에 미치는 영향분석 및 외부차광과 내부차광의 차광효과 비교를 실시하였다. 외부경사차광시 온실 지붕과 차광재의 설치간격은 10-30cm에서 차광효율이 가장 좋은 것으로 나타났으나 환기창의 개폐를 위한 공간이 필요하지 않는 온실에서는 10cm 정도이면 충분한 간격이 될 것으로 판단된. (중략)

  • PDF

Variation of Photosynthetic Photon Flux in Commercial Plastic Greenhouses (상업용 플라스틱 온실의 광합성유효광량자속 변화)

  • Lee, Hyun-Woo;Kim, Young-Shik
    • Current Research on Agriculture and Life Sciences
    • /
    • v.30 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • This study was conducted to provide data necessary for clearing up the way to be able to improve covering and management method of covering material in commercial plastic greenhouse. The photosynthetic photon flux(PPF) in representative 4 different commercial tomato greenhouses was measured and analyzed. The variation trend of daily integral PPF was in agreement with that of the duration of sunshine. Each of daily integral PPF for 4 different experimental greenhouses was quite dissimilar, and was less than the amount of PPF necessary to grow tomato. October to November of beginning of winter was a good season to replace covering material in order to secure more PPF during insufficient winter season in greenhouse. The main inside factors to interrupt PPF incidence were thermal screen, inside covering material, condensation receiver in greenhouse. The single wide span greenhouse covered with PO film was superior to the other experimental greenhouses in the aspect of PPF transmittance.

  • PDF

Effect On the Air Permeability of Composting Bulking Agent (퇴비화 첨가제의 공기투과성에 대한 분석)

  • Kim, Byung Tae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.71-82
    • /
    • 2012
  • Common bulking agents in composting system include woody materials such as sawdust and woodchips. These bulking agents are mainly used for the purpose of the proper control of C/N ratio and moisture content in the composting. The topic for the effect on air permeability of bulking agents has far received relatively little attention in the composting field. This study investigated the effect of bulk density, moisture content, air-filled porosity, particle size and air flow rate on air permeability of several mixture ratios of sawdust and woodchip bulking agent. Increasing the moisture contents, the air-filled porosity was decreased and the particle size was increased for all kinds of bulking agent mixtures. Especially, with the increasing of mixing ratio of woodchip, these effects were sharply magnified. The air permeability respond to air-filled porosity was very similar to that for moisture content which was anticipated the linear relationship between air-filled porosity and moisture content. Above the region of moisture content 0.25 or 0.43(d.b.)(20 or 30% w.b.), the pressure drop decreased even though air-filled pore spaces were filling with water. Especially, to the particle size of 5 mm the pressure drop was decreased exponentially, so the air permeability was dramatically improved. By the water had the role of binding of the small particles, the macropores less resistances to air flow were created in the matrix. The effect of particle size on air permeability was much stronger than that of air-filled porosity or moisture content. And it is needed the preparing of initial particle size above 5 mm for efficient composting.

Preparation of ITO thin film with oxygen gas flow (산소 가스 유량 변화에 따른 ITO 박막의 제작)

  • Geum, Min-Jong;Jeon, A-Ram;Choe, Dong-Hun;Lee, Gyo-Ung;Han, Jeon-Geon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.107-108
    • /
    • 2007
  • 마그네트론 스퍼터링 장치를 이용하여 산소 가스 유량 변화에 따른 ITO 박막을 실온 제작하였다. 그 결과 산소 가스 유량의 증가에 따라 박막의 비저항이 감소하였으며 적정 유량 이상에서는 비저항이 증가하였다. 또한 산소 가스 유량을 3 sccm으로 고정한 후 ITO 박막의 두께를 변화시킨 경우 막 두께 40nm 이상에서 부터는 $0.6{\sim}0.8$ $m{\Omega}-cm$의 비저항과 가시광 영역에서 80% 이상의 광투과율 특성을 나타내었다.

  • PDF

Oxygen Permeation and Syngas Production of La0.7Sr0.3Ga0.6Fe0.4O Oxygen Permeable Membrane (La0.7Sr0.3Ga0.6Fe0.4O 분리막의 산소투과특성 및 합성가스의 생성)

  • 이시우;이승영;이기성;정경원;김도경;우상국
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.594-600
    • /
    • 2003
  • L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ perovskite-type mixed conducting membranes, which could permeate oxygen selectively, have been fabricated and the microstructural features developed by varying the sintering conditions have been analyzed. The effects of surface modification and the membrane thickness on oxygen permeability have been evaluated under He/air environment. With increasing a grain boundary fraction, the overall oxygen permeability decreased. The syngas (CO+ $H_2$) has been produced by partial oxidation reaction of methane with the oxygen permeated through the membrane. Methane conversion and syngas yield have been evaluated as functions of the compositional ratio of feed gas and reaction temperature. In long-term duration test for 600 h, under C $H_4$+He/air environment, L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membrane showed a highly stable performance.

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.