• Title/Summary/Keyword: 적정면적

Search Result 506, Processing Time 0.031 seconds

A Study on the Suitability of the Number of Entrances for Emergency Evacuation Facilities Using Regression Analysis (회귀분석을 이용한 비상대피시설의 출입구 개수 적정성에 관한 연구)

  • Roh, Jeong-Heon;Lee, Jeong-Moon;Kim, Kuk-Joo;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.5
    • /
    • pp.431-438
    • /
    • 2019
  • In this research, the proper number of entrances in the evacuation facilities for civil and military personnel was determined by using parametric study and regression analysis. The current standards on the emergency evacuation facility only set the number of possible evacuees and the architectural floor area after the evacuation have been completed. On the other hand, there are needs to consider the dynamic standards along with allowable evacuation time such as the number of entrance, staircases and so on rather than the static standards such as the floor area. The number of entrances and their location are required in order to account for the allowed evacuation time of particular number of people in a set area. The results of this research could be contributed to the standards which should contain the dynamic conditions associated with evacuation.

Performance Analysis and Implications of Culvert Drain Maintenance (암거배수 정비의 성과분석과 시사점)

  • Hyangmi Yi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.412-412
    • /
    • 2023
  • 정부는 2027년까지 식량자급률 55.4%를 달성하고, 채소·과실류 국내 공급 여력의 85% 수준을 유지하기 위한 적정 농지면적 150.0만ha가 필요하다고 추정하였다. 그리고 정부는 적정 면적 확보를 위해서 농지보전 목표가 포함된 중장기 기본계획을 수립할 예정이다. 이러한 식량자급률 달성과 채소 및 과실류 재배 면적 확보를 위해서는 논의 다각적인 활용 방안을 모색할 필요가 있다. 왜냐하면 최근 쌀 공급과잉 문제를 해결하기 위해 최근 '양곡관리법'이 정치적 이슈로 등장할 만큼 쌀 공급과잉 해소와 논 농지의 효율적인 활용에 대해 사회적 관심이 많다. 이러한 맥락에서 본 연구에서는 우리나라 최초로 논 배수 개선을 위해 지하암거가 설치된 경북상주시 공검면 일대를 대상으로 암거배수의 성과를 살펴보고 개선방안을 모색하였다. 이를 위해 본 연구에서는 지하암거 설치로 배수여건이 개선된 수혜농가 42명을 대상으로 심층면담을 실시하였다. 사례지역은 오태저수지를 기점으로 시작하는 공검소하천 양안에 넓게 위치하고 분지지형으로 하천보다 낮은 저지대로, 평상시·강수시 지하수위가 높아 습답이 형성되어 영농기계 사용이 어렵고, 일부지역의 경우 작물 파종, 수확을 하지 못하는 등 피해 발생하여 영농여건이 매우 불리한 지역이다. 이러한 배수불량을 개선하기 위해 수혜면적 55.6ha에 (지하)배수가 정비되었다. 이러한 배수 개선이 지역 영농에 미치는 효과는 다음과 같이 분석되었다. 첫째, 수혜구역 내 농가들은 배수불량으로 농기계 작업이 불편하고, 논의 습답을 제거하기 위해 해당 시설에 대한 필요성을 느끼고 있다. 또한 암거배수 시설로 인해 약 72% 농가들은 습답 개선의 효과가 있는 것으로 나타났다. 둘째, 전체 수혜농가의 약 72%는 암거시설로 인해 논의 습답이 개선된 것으로 나타났다. 특히, 암거시설로 인해 물빠짐이 개선되었고, 농기계 작업이 용이하게 되었다. 다만 사업 첫해에는 논을 파헤쳐 농기계가 빠지는 피해가 있었지만, 2차년도부터는 논이 정비되어 농기계 빠지는 피해는 없는 것으로 분석되었다. 셋째, 수혜 농가들이 느끼는 "습답 피해가 매우 있음"은 사업 시행 전 51.61%에서 사업 완료 후에는 4.17%로 급격히 감소하였다. 또한 "습답 피해가 전혀 없음"을 느끼는 농가는 사업 시행 전 3.23%에 불과했지만, 사업 완료 후에는 20.83%로 급증하였다.

  • PDF

A Study on Estimating Level-of-Service for Pedestrian Facilities (보행자 시설 서비스 수준 산정에 관한 연구)

  • 김정현;오영태;손영태;박우신
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.1
    • /
    • pp.149-156
    • /
    • 2002
  • 본 연구는 보행자 시설 중 계단과 대기공간에 대해 공학적으로 합리적인 분석방법을 제공하고 이를 통해 안전하고 편리한 보행시설의 제공을 도모하는 것을 목적으로 하였다. 본 연구를 위해 계단과 대기공간에 대한 외국의 조사방법과 분석방법을 참조, 비교하여 서비스 수준 결정기준을 정하고 용량 값을 산출하여 우리나라 현실에 맞는 적정한 설계기준을 산출하기 위해 노력하였다. 계단의 경우 효과척도로 보행 교통량을 그리고 대기공간에 있어서는 1인당 점유면적을 사용하였다. 현장 조사 결과 계단에서의 보행량은 보행자가 군을 형성했을 경우와 그렇지 않은 경우 최대 보행량에 차이가 나는 것을 고려하여 보행자 군의 형성 여부에 따라 서비스 수준의 기준을 다르게 제시하였으며, 대기공간의 경우에는 1인당 점유면적을 한국인의 평균체형을 기준으로 하여 서비스 수준의 기준을 제시하였다. 계단과 대기공간에 있어서 이러한 조사와 분석을 통해 산출된 결과는 외국의 경우와 다른 값을 나타내는데, 계단에 있어서는 실질적으로 이용할 수 있는 유효계단 폭에 따라 최대 보행 교통량의 타이가 크게 나타났으며, 대기공간의 경우에는 한사람이 점유 할 수 있는 용량상태에서의 공간이 0.2$m^2$/인으로 외국의 경우보다 적게 나타난다.

A Study on Optimum Tree Planting Density for Apartment Complex (아파트단지 조경수 적정식재밀도 연구)

  • Oh, Choong-Hyeon;Jeong, Wook-Ju;Lee, Im-Kyu;Kim, Min-Kyung;Park, Eun-Ha
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.140-147
    • /
    • 2012
  • This study was conducted to investigate optimum planting density for apartment complex. The validity of Landscape Architecture Criteria of Korea was checked for it. We compared our field data with Landscape Architecture Criteria. In this step, the tree density of urban forest was regarded as standard. Field study was examined in 3 apartment complexes located in capital area, especially completed during these 10 years. 10 sites in each complex were selected and tree density per unit area were calculated. This field study data was divided standard size and large size which received weight. And, it was compared and analyzed. And crown projected area(CPA) was calculated considering proper growth of low vegetation and sufficient shade. The outcome shows that minimum size of Landscape Architecture Criteria is rational. But, in the case of planting large size tree received weight, tree density was short comparing with the tree density of urban forest and CPA was less than 50%. By the result of field study in 3 apartment complex, the tree density of apartment complex satisfied or exceeded Landscape Architecture Criteria. But, in the case of planting large size tree, tree density and CPA show high density due to addition planting for deficient landscape. Therefore, the revision of the Landscape Architecture Criteria was required such as deletion or minimization of the weighted clause about the large size tree and regulate the limit CPA not less than 50% and not more than 100%.

Assessment of Uncertainty for Discharge Measurement using Velocity-Area method (유속-면적법으로 측정된 유량에 대한 측정 불확도 평가)

  • Kim, Jongmin;Kim, Dongsu;Kim, Seojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.104-104
    • /
    • 2016
  • 소규모 하천에서의 평수기 유량 측정은 일반적으로 지점식 초음파 유속계, 프로펠러 유속계 등을 활용해 도섭법으로 측정된 유속 측정성과를 기반하여 유속-면적법으로 산정된다. 유속-면적법으로 측정된 유량 측정 성과는 횡방향 측선의 수, 수심방향 측점의 수, 측정 시간, 수심 등 제반 측정 인자에 의해 영향을 받고 유량 불확도는 각 인자 별 오차에 영향을 받는다. ISO 748 (2007)과 ISO 1088 (2007)은 유속-면적법 적용방법, 현장 측정 가이드라인, 불확도 인자 별 적용 요건에 따른 오차, 최종 유량 불확도 산정 기법을 제시하였다. 따라서, 국내외 유량조사 기관에서는 유속면적법을 적용할 경우, ISO에서 제시된 인자 별 오차 및 유량 불확도 산정 기법을 기반으로 유량 불확도를 산정해왔다. ISO 748과 1088은 다양한 규모의 실제 하천에서 관측된 자료를 기반으로 횡방향 측선 수, 수심방향 측점 수 (2점법, 3점법 등), 측정 시간 등과 관련된 인자 별 오차를 표로 상세하게 제시하였고 실무에서는 별도 추가 검증없이 사용해 왔다. 그러나, ISO에서 유속-면적법 유량 측정 불확도를 평가하기 위해 사용된 측정자료는 유량을 제어하기 힘들고 유속 측정 상황이 유출 조건 별로 상이한 현장 자료를 기반으로 하였고, 상대적으로 정확도가 낮은 프로펠러유속계를 기반으로 1960년대에 관측된 자료들을 주로 활용하여 도출되었다. 따라서, 본 연구에서는 기존 ISO에서 제시한 유속-면적법에 필요한 인자들의 오차를 정밀 실규모 실험을 통해 재산정하여 기존 ISO 748과 1088에서 제시한 인자별 오차의 적정성을 검증하고자 하였다. 이를 위해 흐름을 안정적으로 통제할 수 있는 건설기술연구원 안동 하천실험센터의 완경사수로(A2)에서 정상상태의 폭 7m, 수심 1m, 유속 약 1m/s의 흐름을 유지한 후, 유속 측정 정확도가 우수한 micro-ADV를 활용하여 공간적으로 매우 정밀하게 유속을 측정하고, 수심은 Total Station을 기반으로 흐름 발생 전에 정밀 측정하였다. 오차 분석 결과, ISO 규정에서 제시한 오차와 본 실험의 결과로 도출된 인자들의 오차는 상당한 차이를 보였다. 따라서, 본 연구 결과로 도출된 유속-면적법의 인자 별 오차는 실험이 수행된 소하천 규모의 하천에서 도섭법으로 산정된 유량의 불확도를 평가할 경우에 활용될 것으로 기대된다.

  • PDF

Research on The Modeling of Appropriate Parking Space for Mass Traffic Generating Facilities (대량 교통유발시설의 적정주차 추정모형구축에 관한 연구)

  • 오윤표;장무렬
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.3
    • /
    • pp.61-73
    • /
    • 2001
  • The purpose of this study is to simulate the suitable space of parking lots for Mass traffic instigating facilities in Pusan. After the suitable scale of parking lots estimate using GPSS, one of the Queue Simulation, with the average arriving time and the average parking time at parking lots, the formula is simulated by the Regression model to relate a total floor area and the suitable number of parking lots. The improved criteria or present parking lots is needed to prevent the unnecessary vehicles and improve the efficiency of land use. The suitable scale of parking lots estimate just with the state of using the parking lots in this study. but it is necessary to consider land use, traffic condition, commercial area etc.

  • PDF

Reservoir Sizing for Irrigation to Upland Area with Sparse Data (자료 부족 지역의 밭 관개용수 공급을 위한 저수지 규모 결정)

  • Noh, Jae-Kyoung;Lee, Jae-Nam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.372-372
    • /
    • 2012
  • 해외 사업에서 지구에 따라 기상 자료가 부족한 지역이 많다. 여기서는 에티오피아의 밭 관개 용수 공급을 위해 일 강우 자료와 월평균 기상자료를 이용하여 일 증발 자료를 생산하여 적정 저수지 위치와 규모를 정한 결과 다음과 결과를 얻었다. 첫째, 구글지도와 DEM을 이용하여 6개의 댐 후보지를 선정하였고, 표고별 저수면적, 저수량 관계식을 도출하였다. 둘째, 기상자료 수집의 어려움으로 한국 자료를 분석하여 현지의 장기간 기상 자료를 가공, 모의하여 적용하였다. 셋째, 현지 유량측정 자료와 한국 관측자료를 이용하여 현지의 합리적인 일 유입량 자료를 생산하였다. 넷째, 현지의 토양조건을 고려하고, 토양수분 물수지 모형을 개발하여 토양수분 부족량 공급 기준의 합리적 관개용수 필요수량을 산정하였다. 다섯째, 저수지 일 물수지 모형을 구축하여, 저수량 일별 모의에 의해 적정 댐 저수지 규모를 결정하였다. 여섯째, 국내 농업용 저수지의 실적 공사비 내역 자료를 참고하여 합리적 수준의 개략 공사비와 총 사업비를 산출하였다. 일곱째, 최적 저수지 위치와 규모로 유역면적 $739.57km^2$인 위치와 만수위 EL. 1,660 m, 총 저수량 3,529만 $m^3$인 규모를 제시하였다.

  • PDF

Survey and model development of the mechanization for swine farming (양돈농가의 기계화 실태분석 및 모델개발)

  • 이성현;박원규;강창호;오권영
    • Journal of Bio-Environment Control
    • /
    • v.7 no.2
    • /
    • pp.91-108
    • /
    • 1998
  • This study was carried out to survey basic information of swine farms on the machine holdings. facility type. management of manure by farm scale and operation, and then to develop the mechanization model. Manual feeding was common for sows and nursing sows. but automation feeding was normally furnished for weaners. growing pigs and castrated male pigs. Water supplies was completely automated for all of the surveyed swine farms. Fully mechanized and automated system would not be feasible and affordable for the small scale farms breeding less than 500 heads. Because the environmental control for the nursing sows and weaner was important, some swine houses were constructed with the windowless type. However, the furnished rates ranged from 22.2% to 44.4% of the surveyed nursing sow and weaner houses at the farm scales. In the future, a computerized ventilation system would be commended for the efficient use of heat energy and to maintain the desirable temperature of swine buildings. Over-investment for large scale farm and over-crowded pigpen of small farm would cause wasting construction expenses and spreading epidermic diseases Hence, the size of swine building should follow the recommended scale. The fermentation drier was recommended for the manure management. Urine could be recycled or discharged after treating by the activated sludge process.

  • PDF

A Comparison of Density and Patient Doses According to kVp and mAs Changes in General Radiography (일반촬영에서 kVp와 mAs의 변화에 따른 농도와 환자 선량 비교)

  • Kang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.987-994
    • /
    • 2019
  • Low energy x-rays that occur in the low tube voltage radiography of general radiography are absorbed strongly in the body and do not aid image quality enhancement. This study maintains titer in general radiography while using tube current that are proportional to density and the tube voltage 15% principle according to density to reduce patient exposure doses, and area doses and entrance surface doses were measured to compare patient exposure doses. In hand, knee, abdomen, and skull radiography, kVp was increased to 115% and mAs was decreased to 50% and kVp was decreased to 85% while mAs was increased to 200% and area doses and entrance surface doses were measured to compare relative doses. Also, 5 places in each image were set, density was measured, and Kruskal wallis H test was conducted to observe significance probabilities between groups. To fix density, kVp was increased to 115% and mAs was decreased to 50% and after measurements of mean area doses and entrance surface doses were made by each part, each decreased to 58.68% and 59.85% when standard doses were set to 100%, and each increased to 147.28% and 159.9% when kVp was decreased to 85% and mAs was increased to 200%. Comparisons of density changes showed that hand, knee, abdomen, and skull radiography all displayed significance probabilities>0.05, showing no changes in concentration. Radiography that increases kVp and lowers mAs through reasonable calculations within ranges that don't affect resolution and contrast seems to be a simple way to decrease patient exposure doses.

An Analysis on the Characteristics of Site Planning and Size of Newly-Built Elementary Schools in Sejong City (세종시 신설 초등학교의 학교규모와 배치특성 분석)

  • Song, Byung-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.357-366
    • /
    • 2016
  • This study compared 24 newly-built elementary schools in Sejong City regarding the size of the site and school, as well as the outdoor space to improve the site and space programming in school planning. Among the others, one result indicates that the overall number of classes in a school should be reduced to 48, including the affiliated kindergarten, instead of the present number of 50. In addition, the number of classes must be counted in lieu of the number of student by classifying the size of school. In light of the present mean ratio of school building area per site in the city of 24.6%, which is much higher than other comparable city schools, the ratio should be about 20.0% by increasing the sports facility and outdoor spaces. In addition, the deprivation of the area caused by the district-unit-plan and the irregularity of the place should also be considered when determining the size of a school and site.