• Title/Summary/Keyword: 적외선 체열영상

Search Result 27, Processing Time 0.019 seconds

Realization of Infrared Thermograph System (적외선 체열촬영시스템의 구현)

  • 이수열;우응제;조민형
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.13-24
    • /
    • 1994
  • In the conventional thermograph systems, expensive infrared lens systems are usually used for accomodating infrared beams to high speed optical scanners. In this study, a cheap focussing mirror with a two dimensional scanner are used for the development of medical infrared thermograph system in which high speed imaging is not critically required. The infrared thermograph system can be used for two dimensional imaging of human skin temperature by measuring the amount of infrared lights radiating from it. It has been experimentally proven that the accuracy of temperature measurements using the developed system is under 0.1$^{\circ}C$ with image matrix size of 256${\times}$240, and imaging time of 4 seconds.

  • PDF

Development and Possibility Evaluation of Thermal Imaging Camera for Medical Monitoring of Body Temperature (열화상카메라 개발을 통한 의료용 체열진단 가능성 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 2015
  • Recently, thermography camera have been using for body-temperature monitoring. We report on fabrication of prototype thermography camera using the chalcogenide-glass lens and the camera test by analysis of thermal image. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ with noise equivalent temperature difference(NETD) of 87.7mK. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.

A study on the method for thermal imaging of each abdominal region (복부 영역별 체열 영상 획득 방법 연구)

  • Kim, Keun Ho;Choi, Woosu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.397-399
    • /
    • 2021
  • 한의사의 복진을 모사하는 진단기기와 이를 이용하여 질환과 변증을 분류하는 알고리즘을 개발하는 연구가 진행되고 있다. 본 연구에서 적외선 체열 영상과 접촉식 온도계로부터 구성되는 복부 영역별 체열 영상 시스템을 제시하였고, 복부 영역의 절대 온도를 보정하는 방법을 살펴보았다. 접촉식 온도계를 활용해 추가로 복부표면 온도를 측정하였고, 동시에 열화상 카메라로도 영상을 촬영하여, 동일위치에서 열화상 영상의 온도값과 접촉식 체온계의 온도값을 비교해 전체 열화상 영상을 보정하였다. ICC 값이 0.96으로 나와 높은 재현성을 보였다.

Use of Digital Infrared Thermography on Experimental Spinal Cord Compression in Dogs (개에서 실험적으로 유발한 척수압박에 대한 적외선 체열촬영술의 적용)

  • Kim Wan-Tae;Kim Min-Su;Kim Sun Young;Seo Kang-Moon;Nam Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.302-308
    • /
    • 2005
  • This study was performed to examine the absolute skin temperature and temperature difference $({\Delta}T)$ between the left and the right, the upper and the lower parts on the back of dog and to investigate the clinical usefulness of infrared thermography as diagnostic or prognostic aid on experimental spinal cord compression by using Digital Infrared Imaging System. In normal dogs, symmetrical and contouring patterns were observed in thermogram. The skin temperature difference was not significant between the left and the right, the upper and the lower parts on the back. In spinal cord compressed dog, there was symmetrical temperature reduction pattern around lesion. Patterns of ${\Delta}T$ between thoracic and lumbar portions were remarkable and showed the tendency to return to normal after 4 weeks of operation. It is considered that infrared thermography is a useful diagnostic and prognostic aid for spinal cord injury in dogs.

Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image (개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.365-371
    • /
    • 2019
  • We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.

Measurement of ROI Temperature in Herniation of Intervertebral Disc Patients Using DITI (디지털 적외선 체열진단기를 이용한 추간판탈출증 환자의 ROI 온도측정)

  • Park, Jeong Kyu;Park, Jong Sam;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.273-278
    • /
    • 2017
  • Among 45 patients of herniation of intervertebral disc with $L_4$ to $L_5$ herniation, who underwent infrared thermography, the number of female was larger than male and the age of 50s was highest. From the results measured from the distribution table, we have confirmed that there was no significant difference depending on sex and age (p> 0.05). The region of the highest ROI temperature for patients with $L_4-L_5$ intervertebral disc prolapse was the back of the posterior right tibia, and followed by the back of the left shin bone-below the front right knee-below the front left knee. There was a significant difference depending on the measured site. The average ROI temperature for patients was $30.30{\pm}0.50$ whereas that for normal persons was $31.20{\pm}0.58$, yielding the temperature difference of $0.66{\pm}0.59$ between the two groups. The ROI of patients was lower than $31.20{\pm}0.58$ (p <0.05) because the significance of the sample, which has been obtained from the results of a sample t-test, was less than 0.05 (p <0.05). From further researches, it may necessary to develope the methodology for correcting data regarding thermal environment and, in addition, to develope a new thermal index based on it. Therefore, we can confirm that pre-treatment for infrared thermography is very important in order to minimize the procedure for correcting data. It is required that radiologists who inspect disc herniations should carefully observe and consider the patients during their measurements.

Review of Clinical Trials on Infrared Thermography Using Search of Papers in Medline within 5 Years (적외선 체열영상을 이용한 최신 해외 임상연구 동향)

  • Hwang, Deok-Sang;Park, Kyoung-Sun;Kim, Eun-Gyung;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.8 no.1
    • /
    • pp.13-17
    • /
    • 2010
  • Purpose : This study is to the recent trends of clinical trial using infrared thermography and to review its application in medicine. Methods : We searched for papers which had used infrared thermography in Medicine within 5 years, using English. Results : A total of 23 papers were but 8 were found, but 8 were not related to non-invasive infrared thermography. The other 15 papers were clinical trials about the effect of acupuncture and therapeutic massage, evaluation of post-hepatic neuralgia, sleep disorder, and regional circulation. Conclusion : These results suggest that infrared thermography can be used as a reliable and helpful method in many clinical trials.

  • PDF

Relation between Changes of DITI and Clinical Results according to the Level and Extent of Sympathicotomy in Essential Hyperhidrosis (본태성다한증에서 흉부교감신경의 차단 범위와 부위에 따른 임상결과와 체열변화 사이의 관계)

  • 최순호;임영혁;이삼윤;최종범
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.64-71
    • /
    • 2004
  • Background: Video-assisted sympathicotomy is a safe and effective method for the treatment of essential hyperhidrosis with immediate symptomatic improvement. However, this is offset by the occurrence of a high rate of side-effects, such as embarrassing compensatory hyperhidrosis. Therefore, by comparing and assessing the relationship between temperature change measured by DITI (digital infrared thermographic imaging) and clinical results according to the level and extent of sympathicotomy in essential hyperhidrosis. we tried to obtain a more precisely and objectively, the distribution and degree of compensatory sweating by DITI and also for ascertaining the clinical usefulness. Material and Method: From January 2000 to June 2002, the thoracoscopic sympathicotomy was performed in 28 patients suffering from essential hyperhidrosis in Dept. of Thoracic and Cardiovascular Surgery, Wonkwang University Hospital. The patients were divided into four groups, Group I: patients having undergone T2 sympathicotomy, Group II: patients having undergone T3 sympathicotomy, Group III: patients having undergone T3,4 sympathicotomy, and Group IV: patients having undergone T2,3,4 sympathicotomy. The parameters were composed of the satisfaction rate of treatment, the degree of compensatory and plantar sweating, and temperature changes of entire body measured by DITI Result: There was no difference in age and follow-up period among the groups. All of the treated patients obtained satisfactory alleviation of essential hyperhidrosis in immediate postoperative period. However, the rate of long-term satisfaction were 85.8%, 85.8%, 42.9%, and 28.6% in group I, II, III, and IV (p<0.05). More than embarrassing compensatory sweating was present in 14.2%, 14.2%, 57.1%, 71.4% in group I, II, III, and IV (p<0.05) In regard to plantar sweating, decrease in sweating was expressed in each of four groups, but was not significant between groups. An apparent increase of temperature measured by DITI indicated sufficient denervation and predicted long-lasting relief of essential hyperhidrosis and also decrease in temperature of trunk and lower extremity by DITI had correlated well with postoperative satisfaction, and also postoperative compensatory sweating. Conclusion: We suggested that the incidence and degree of compensatory sweating was closely related to the site and the extent of thoracic sympathicotomy. Resection of the lower interganglionic neural fiber of the second thoracic sympathetic ganglion on the third rib is the most practical and minimally invasive treatment than other surgical methods. We were also to anticipated the distribution and degree of compensatory sweating by DITI precisely and objectively and for ascertaining the clinical usefulness.

The Method of medical Infrared Thermographic imaging using an Infrared LED Lamps (적외선 LED 램프를 이용한 적외선 체열 영상 진단)

  • Song, M.J.;Ryu, S.M.;Soo, B.M.;Kim, J.S.;Choi, W.S.;Park, C.B.;Kim, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.282-282
    • /
    • 2010
  • LED Device was designed of electronic circuits of electrical power part for used Pspice student version and used Infrared LED lamps of load part. LED was used Computerized Electronic Medical Infrared Thermographic Imaging System for body surface Investigation of variable Body thermal asymmetry. It was knowledge body thermal Asymmetry of body surface and quantity body surface of electromagnetic wave to inflow electrical power part.

  • PDF