• Title/Summary/Keyword: 적외분광분석

Search Result 307, Processing Time 0.02 seconds

Highly-permeable Mixed Matrix Membranes Based on SBS-g-POEM Copolymer, ZIF-8 and Ionic Liquid (SBS-g-POEM 공중합체, ZIF-8, 이온성 액체에 기반한 고투과성 혼합 매질 분리막)

  • Kang, Dong A;Kim, Kihoon;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.29 no.1
    • /
    • pp.44-50
    • /
    • 2019
  • In this paper, we developed mixed matrix membranes (MMMs) consisting of SBS-g-POEM block-graft copolymer, ionic liquid (EMIMTFSI) and ZIF-8 nanoparticles to separate a $CO_2/N_2$ gas pair. The SBS-g-POEM is a rubbery block-graft copolymer synthesized through low-cost free-radical polymerization. The EMIMTFSI was dissolved into the SBS-g-POEM matrix and solution synthesized ZIF-8 nanoparticles were also dispersed into the copolymer matrix. The physico-chemical properties of manufactured membranes were characterized by Fourier transform infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC), scanning electron microscopy (SEM), X-ray diffraction (XRD), which showed that the components were compatible with each other. The gas separation performance was confirmed by time-lag measurements showing $CO_2$ permeability of 537.0 barrer and $CO_2/N_2$ selectivity of 15.2. The result represents the EMIMTFSI and ZIF-8 nanoparticles improves the gas permeability more than two-times, without significantly sacrificing the $CO_2/N_2$ selectivity.

Simulation of Sentinel-2 Product Using Airborne Hyperspectral Image and Analysis of TOA and BOA Reflectance for Evaluation of Sen2cor Atmosphere Correction: Focused on Agricultural Land (Sen2Cor 대기보정 프로세서 평가를 위한 항공 초분광영상 기반 Sentinel-2 모의영상 생성 및 TOA와 BOA 반사율 자료와의 비교: 농업지역을 중심으로)

  • Cho, Kangjoon;Kim, Yongil
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.2
    • /
    • pp.251-263
    • /
    • 2019
  • Sentinel-2 Multi Spectral Instrument(MSI) launched by the European Space Agency (ESA) offered high spatial resolution optical products, enhanced temporal revisit of five days, and 13 spectral bands in the visible, near infrared and shortwave infrared wavelengths similar to Landsat mission. Landsat satellite imagery has been applied to various previous studies, but Sentinel-2 optical satellite imagery has not been widely used. Currently, for global coverage, Sentinel-2 products are systematically processed and distributed to Level-1C (L1C) products which contain the Top-of-Atmosphere (TOA) reflectance. Furthermore, ESA plans a systematic global production of Level-2A(L2A) product including the atmospheric corrected Bottom-of-Atmosphere (BOA) reflectance considered the aerosol optical thickness and the water vapor content. Therefore, the Sentinel-2 L2A products are expected to enhance the reliability of image quality for overall coverage in the Sentinel-2 mission with enhanced spatial,spectral, and temporal resolution. The purpose of this work is a quantitative comparison Sentinel-2 L2A products and fully simulated image to evaluate the applicability of the Sentinel-2 dataset in cultivated land growing various kinds of crops in Korea. Reference image of Sentinel-2 L2A data was simulated by airborne hyperspectral data acquired from AISA Fenix sensor. The simulation imagery was compared with the reflectance of L1C TOA and that of L2A BOA data. The result of quantitative comparison shows that, for the atmospherically corrected L2A reflectance, the decrease in RMSE and the increase in correlation coefficient were found at the visible band and vegetation indices to be significant.

Analysis of Spectral Reflectance Characteristic Change during Growing Status of Rice Plants using Spectroradiometer (스펙트로레디오메터를 이용한 벼 생장시기의 분광반사 특성 변화 분석)

  • Jang, Se-Jin;Suh, Ae-Sook;Kim, Pan-Gi;Yun, Jin-Il
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.3
    • /
    • pp.12-19
    • /
    • 2000
  • Knowledge for reflectance characteristic of interesting targets will provide us with actual application of remote sensing on agriculture. In this study, we have measured and analyzed reflectivity characteristics based on growing status from transplanting time to harvesting time. Rice paddies transplant into 3 fields at 20, May, 1999. Measurement of reflectivity characteristics were carried out with a portable spectroradiometer for frequencies from 300nm to 1100nm during the time period from 11:00 AM to 01:00 PM of clear sky and calm a day. The measurements for a day repeated 3 times(also, 3 times to each measurement)for reliable values. In result, we found that averaged reflectivity of visible range has about 2.34% - 2.55% in blue region(400nm-498nm), about 5.05% - 6.01% in green region(500nm-598nm) and about 4.21% - 5.24% in red region(600nm-698nm). It must be noted that the more rice canopy grows, the more spectral reflectivity decreases in visible region. Also, we separated infrared region into two cases - One case is increasing region with 700nm-780nm, the other is fixed region with 800nm-1100nm. Averaged reflectivity of these regions has about 22.3% - 23.0% in increasing region, about 29.4% - 33.1% in fixed region. It must be noted that more rice canopy grows, the more spectral reflectivity also increases up to 23, Aug. in infrared region. After 23, Aug, the reflectivity has a tendency toward decrease.

  • PDF

Near Infrared Spectroscopy for Diagnosis: Influence of Mammary Gland Inflammation on Cow´s Milk Composition Measurement

  • Roumiana Tsenkova;Stefka Atanassova;Kiyohiko Toyoda
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.59-66
    • /
    • 2001
  • Nowadays, medical diagnostics is efficiently supported by clinical chemistry and near infrared spectroscopy is becoming a new dimension, which has shown high potential to provide valuable information for diagnosis. The investigation was carried out to study the influence of mammary gland inflammation, called mastitis, on cow´s milk spectra and milk composition measured by near infrared spectroscopy (NIRS). Milk somatic cell counts (SCC) in milk were used as a measure of mammary gland inflammation. Naturally occurred variations with milk composition within lactation and in the process of milking were included in the experimental design of this study. Time series of unhomogenized, raw milk spectral data were collected from 3 cow along morning and evening milking, for 5 consecutive months, within their second lactation. In the time of the trial, the investigated cows had periods with mammary gland inflammation. Transmittance spectra of 258 milk samples were obtained by NIRSystem 6500 spectrophotometer in 1100-2400 nm region. Calibration equations for the examined milk components were developed by PLS regression using 3 different sets of samples: samples with low somatic cell count (SCC), samples with high SCC and combined data set. The NIR calibration and prediction of individual cow´s milk fat, protein, and lactose were highly influenced by the presence of mil samples from animals with mammary gland inflammation in the data set. The best accuracy of prediction (i.e. the lower SEP and the higher correlation coefficient) for fat, protein and lactose was obtained for equations, developed when using only “healthy” samples, with low SCC. The standard error of prediction increased and correlation coefficient decreased significantly when equations for low SCC milk were used to predict examined components in “mastitis” samples with high SCC, and vice versa. Combined data set that included samples from healthy and mastitis animals could be used to build up regression models for screening. Further use of separate model for healthy samples improved milk composition measurement. Regression vectors for NIR mild protein measurement obtained for “healthy” and “mastitic” group were compared and revealed differences in 1390-1450 nm, 1500-1740 nm and 1900-2200 nm regions and thus illustrated post-secretory breakdown of milk proteins by hydrolytic enzymes that occurred with mastitis. For the first time it has been found that monitoring the spectral differences in water bands at 1440 nm and 1912 nm could provide valuable information for inflammation diagnosis.

Influence of Fluorinated Illite on Thermal, Antibiotic and Far-infrared Emission Properties of Polypropylene Non-woven Fibers (폴리프로필렌 부직포 섬유의 열, 항균 및 원적외선 방사 특성에 미치는 불소화 일라이트 첨가의 영향)

  • Kim, Jinhoon;Im, Ji Sun;Seo, Kyeong-Won;Lee, Young-Seak
    • Polymer(Korea)
    • /
    • v.37 no.1
    • /
    • pp.86-93
    • /
    • 2013
  • In this work, the thermal, antibiotic properties and far-infrared emissivity of fluorinated illite embedded polypropylene non-woven fibers (f-illite/PP fibers) were investigated in the presence of 0, 1, 3, 5 and 7 wt% illite powders. The thermal properties of f-illite/PP fibers were studied by thermogravimetric analysis (TGA). Their antibiotic properties were examined by Staphylococcus aureus and Klebsiella pneumoniae test. Their far-infrared emissivity was also investigated by Fourier transform infrared spectroscopy. From the experimental results, thermal, antibiotic properties and far-infrared emissivity of f-illite/PP fibers were improved by increasing fluorinated illite contents and the property values of 5 wt% f-illite/PP fibers were increased remarkably by about 10.3, 41.2 and 9.8% respectively in comparison with PP non-woven fibers having no fluorinated illite additive. This result was interpreted as the development of interfacial adhesion force between the polymer chains due to the fluorination of illite power.

Surface Coating Treatment of Phosphor Powder Using Atmospheric Pressure Dielectric Barrier Discharge Plasma (대기압 유전체배리어방전 플라즈마를 이용한 형광체 분말 코팅)

  • Jang, Doo Il;Ihm, Tae Heon;Trinh, Quang Hung;Jo, Jin Oh;Mok, Young Sun;Lee, Sang Baek;Ramos, Henry J.
    • Applied Chemistry for Engineering
    • /
    • v.25 no.5
    • /
    • pp.455-462
    • /
    • 2014
  • This work investigated the hydrophobic coating of silicate yellow phosphor powder in the form of divalent europium-activated strontium orthosilicate ($Sr_2SiO_4:Eu^{2+}$) by using an atmospheric pressure dielectric barrier discharge (DBD) plasma with argon as a carrier and hexamethyldisiloxane (HMDSO), toluene and n-hexane as precursors. After the plasma treatment of the phosphor powder, the lattice structure of orthosilicate was not altered, as confirmed by an X-ray diffractometer. The coated phosphor powder was characterized by scanning electron microscopy, fluorescence spectrophotometry and contact angle analysis (CAA). The CAA of the phosphor powder coated with the HMDSO precursor revealed that the water contact angle increased from $21.3^{\circ}$ to $139.5^{\circ}$ (max. $148.7^{\circ}$) and the glycerol contact angle from $55^{\circ}$ to $143.5^{\circ}$ (max. $145.3^{\circ}$) as a result of the hydrophobic coating, which indicated that hydrophobic layers were successfully formed on the phosphor powder surfaces. Further surface characterizations were performed by Fourier transform infrared spectroscopy and X-ray photoelectron spectrometry, which also evidenced the formation of hydrophobic coating layers. The phosphor coated with HMDSO exhibited a photoluminescence (PL) enhancement, but the use of toluene or n-hexane somewhat decreased the PL intensity. The results of this work suggest that the DBD plasma may be a viable method for the preparation of hydrophobic coating layer on phosphor powder.

Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength (광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향)

  • Yoo, Ji-A;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.324-335
    • /
    • 2011
  • Objectives: This study investigated the effects of the color components of light-cured composite resin before and after polymerization on degree of conversion (DC) and biaxial flexural strength (FS). Materials and Methods: Four enamel shades (A1, A2, A3, A4) and two dentin shades (A2O, A3O) of Premisa (Kerr Co.) and Denfil (Vericom Co.) were evaluated on their CIE $L^*,\;a^*,\;b^*$ color components using the spectrophotometer before curing, after curing and at 7 day. The DC of same specimens were measured with Near-infrared spectrometer (Nexus, Thermo Nicolet Co.) at 2 hr after cure and at 7 day. Finally, the FS was obtained after all the other measurements were completed at 7 day. The correlations between each color component and DC and FS were evaluated. Results: The light-curing of composite resin resulted in color changes of Premisa in red-blue direction and Denfil in green-blue direction. The DC and FS were affected by product, time and shade (3-way ANOVA, p < 0.05) and product and shade (2-way ANOVA, p < 0.05), respectively. Premisa only showed a significant correlation between the DC and CIE $a^*$ component - before and after polymerization (Pearson product moment correlation, p < 0.05). The FS of Premisa showed significant negative correlations with CIE $a^*$ and CIE $b^*$ components. Conclusions: The DC and FS of the light-curing composite resin were affected by the color components of the material before and after polymerization.