Possible Use of NIR Spectroscopy for Soil Testing (토양검정에서 근적외 분광분석기의 이용 가능성)

  • Ryu, Kwan-Shig;Cho, Rae-Kwang;Park, Woo-Churl;Kim, Bok-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.4
    • /
    • pp.273-277
    • /
    • 2001
  • Traditional methods of chemical analysis for the soil properties take time and produce harmful waste. The purpose of this research was to evaluate an NIR technique for measuring some soil properties that are rapid and accurate in soil fertility assessments. The NIR instrument (InfraAlyzer 500, Bran & Luebbe Co.) was used for obtaining spectral data from 140 finely ground soil for calibrations and validation estimating pH, CEC, extractable Ca, Mg, K, $SiO_2$, humic acid and EC. Partial least square regression analysis was used to develop a calibration of NIR spectroscopy method. The results indicated that NIR spectroscopy could be used as a routine nondestructive method quantitatively determining soil chemical properties quickly. However the NIR technique may require sample preparation to obtain even diffuse reflection spectra from the soil and data manipulations to obtain optimal predictions.

  • PDF

Nondestructive Evaluation of Free Acid Content in Apples using Near-infrared Spectroscopy (근적외 분광분석법을 응용한 사과의 유리산 함량 측정)

  • Sohn, Mi-Ryeong;Cho, Rae-Kwang
    • Applied Biological Chemistry
    • /
    • v.41 no.3
    • /
    • pp.234-239
    • /
    • 1998
  • In non-destructive evaluation of free acid content in apples by near- infrared spectroscopy(NIRS), browning and heat treatment of squeezed apple juice affected to the accuracy but titrable alkali concentration did not. The free acid content in apples after harvest was able to determine using different apples in harvest time for calibration making. The result of MLR, multiple correlation coefficient(R) was 0.77 and standard error of prediction(SEP) was 0.03%. The free acid content in apples during storage was able to determine using calibration equation established with stored apples, R was 0.90 and SEP was ca. 0.04%. The prediction accuracy by LAIR was not sufficient for use of quantitative analysis of free acid content in apple, but classification of law and high level in acid content was supposed to be applicable.

  • PDF

Rapid Evaluation of Chemical Components of Rice Grain Using Near Infrared Spectroscopy (근적외분광분석법에 의한 미질관련 성분 측정)

  • 황흥구;조래광;손재근;이수관
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.39 no.1
    • /
    • pp.7-14
    • /
    • 1994
  • This study was conducted to establish the rapid evaluation method of chemical components of rice grain on the basis of non-destructive method. A near-infrared reflectance spectroscopic(NIRS) method was utilized, for the determination of amylose, protein, magnesium, and potassium content of rice. A multiple linear regression analysis for the data obtained by standard laboratory methods and NIRS method was carried out to make a calibration. The standard error of prediction for amylose, protein, magneisum and potassium content were 0.88%, 0.28%, 12.62mg and 10.79mg, respectively. It was concluded that the NlRS method can be useful the rapid determination of amylose, protein, magnesium and potassium content instead of the existing laboratory method.

  • PDF

Rapid Quality Evaluation of Dried Red Pepper by Near-infrared Spectroscopy (근적외 분광분석법에 의한 건조고추의 품질측정)

  • Cho, Rae-Kwang;Hong, Jin-Hwan;Kim, Hyun-Koo;Park, Moo-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.675-680
    • /
    • 1990
  • A near-infrared reflectance spectroscopic(NIRS) method which has been recently developed for a non-destructive method for measuring ingredients in foods and agricultural products especially was evaluated for the determination of capsanthin, total sugar, capsaicin and moisture contents in Korean domestic red peppers. A multiple linear regression analysis with the data obtained by standard-laboratory methods(capsaicin by GC, capsanthin by Colorimetry, total sugar by HPLC and moisture by Vacuum drying method) and NIRS method was carried out to make a calibration. The accuracy of the NIRS method was found to be adequate when the standard-laboratory values for a set of sample that were not included in the calibration, were compared. It is concluded that the NIRS method is suitable for the determination of total sugar and capsanthin.

  • PDF

A Study for Automatic Analysis of Qualysis of Quality Components in Tabacco Leaves Using Non-destructive Analytical Method (근적외 분광분석법에 의한 잎담배의 품질측정 자동화)

  • Cho, Rae-Kwang;Lee, Kyung-Hee;Lee, Jung-Hwan;Kwon, Yong-Kil
    • Applied Biological Chemistry
    • /
    • v.37 no.5
    • /
    • pp.349-355
    • /
    • 1994
  • The present study was conducted to develop the automatic analytical method for determining moisture, nicotine, reducing sugar and total nitrogen contents and color(L, a, b) value in domestic tobacco leaves using near infrared(NIR) spectroscopy. The results of multiple linear regression analysis between chemical and NIR data showed that NIR spectro-scopy can determine those quality components of tobacco samples in 30 seconds, non-destructively. The results using developed calibrations are summarized as follows; The standard error of prediction(SEP) for moisture, nicotine. total nitrogen, reducing sugar contents and color(L, a, b) value in domestic tobacco leaves was 0.28%, 0.25%, 0.07%, 0.75%, 1.25, 0.44 and 1.07, respectively. In addition, The possibility of developing the cheaper filter type NIR instrument, for quality evaluation in the procurement from leaf tobacco cultivators and process control was investigated.

  • PDF

Possibility of the Nondestructive Quality Evaluation of Apples using Near-infrared Spectroscopy (근적외 분광분석법을 응용한 사과의 비파괴 품질 측정 가능성 조사)

  • Sohn, Mi-Ryeong;Kwon, Young-Kil;Lee, Kyung-Hee;Park, Woo-Churl;Cho, Rae-Kwang
    • Applied Biological Chemistry
    • /
    • v.41 no.2
    • /
    • pp.153-159
    • /
    • 1998
  • A possibility of evaluation of the major internal quality factors-Brix, moisture contents, firmness and acid content in the Korean domestic 'Fuji'apple fruits by near-infrared reflectance spectroscopic (NIRS) methods were investigated. A multiple linear regression(MLR) analysis between the data obtained by physico- chemical analysis method using refractometer, freeze drier, texture analyzer and titrater and NIR spectral data was carried out to make a calibration. The standard error of prediction(SEP) of Brix, moisture, firmness and acid content were $0.50^{\circ}Brix,\;0.64%,\;0.14kg/cm^2$ and 0.07%. It is concluded that NIRS methods can be used to evaluate Brix and moisture contents of in a apple non-destructive and rapid way but the accuracy for determination of firmness and acid content was slightly low.

  • PDF

Real-time monitoring for blending uniformity of trimebutine CR tablets using near-infrared and Raman spectroscopy (근적외분광분석법과 라만분광분석법을 이용한 트리메부틴말레인산 서방정의 혼합 과정 모니터링)

  • Woo, Young-Ah
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.519-526
    • /
    • 2011
  • Chemometrics using near-infrared (NIR) and Raman spectroscopy have found significant uses in a variety quantitative and qualitative analyses of pharmaceutical products in complex matrixes. Most of the pharmaceutical can be measured directly with little or no sample preparation using these spectroscopic methods. During pharmaceutical manufacturing process, analytical techniques with no or less sample preparation are very critical to confirm the quality. This study showed NIR and Raman spectroscopy with principal component analysis (PCA) was very effective for the blending processing control. It is of utmost importance to evaluate critical parameters related to quality of products during pharmaceutical processing. The blending is confirmed by off-line determination of active pharmaceutical ingredient (API) by a conventional method such as high performance liquid chromatography (HPLC) and UV spectroscopy. These analytical methods are time-consuming and ineffective for real time control. This study showed the possibility for the determination of blend uniformity end-point of CR tablets with the use of both NIR and Raman spectroscopy. The samples were acquired from six positions during blending processing with U-type blender from 0 to 30 min. Using both collected NIR and Raman spectral data, principal component analysis (PCA) was used to follow the uniformity of blending and finally determine the end-point. The variation of homogeneity of six samples during blending was clearly found and blend uniformity end-point was successfully confirmed in the domains of principal component (PC) scores.