• Title/Summary/Keyword: 저항열

Search Result 1,199, Processing Time 0.028 seconds

A Study on the High Frequency Ultrasonic Attenuation Characterization in Artificially Aging Degraded 2.25Cr-1Mo Steel (2.25Cr-1Mo 강 인공 열화재의 고주파수 초음파 감쇠특성에 관한 연구)

  • Park, Ik-Keun;Park, Un-Su;Kim, Chung-Seok;Kim, Hyun-Mook;Kwun, Sook-In;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.439-445
    • /
    • 2001
  • The destructive method is reliable and widely used lot the estimation of material degradation but, it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. Ultrasonic nondestructive evaluation technique has been reported good to attain efficiency of measurement, high sensitivity of measurement, and rapidity and reliability of result interpretation. In this study, it was verified experimentally the feasibility of the evaluation of degraded 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at $630^{\circ}C$ by high frequency longitudinal wave method investigating the change of attenuation coefficient by FFT analysis and wavelet transform. Because of carbide precipitation increase and spheroidization near grain boundary of microstructure to aging degradation, attenuation coefficient had a tendency to increase as degradation proceeded. It was identified possibly to evaluate degradation using the characteristics of high-frequency ultrasonics. Frequency dependence of ultrasonic attenuation coefficient to aging degradation appeared large, which made sure that attenuation coefficient is an important parameter for evaluation of aging degradation.

  • PDF

Synthesis of High-Quality Monolayer Graphene on Copper foil by Chemical Vapor Deposition

  • Lee, Su-Il;Kim, Yu-Seok;Song, U-Seok;Jo, Ju-Mi;Kim, Seong-Hwan;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.351-352
    • /
    • 2011
  • 그래핀(Graphene)은 2차원 평면구조의 $sp^2$ 탄소 결합으로 이루어진 물질이다. 일반적으로 그래핀은 탄소 원자 한층 정도의 얇은 두께를 가지면서 강철의 100배 이상 높은 강도, 다이아몬드보다 2배 이상 뛰어난 열 전도성, 그리고 규소보다 100배 이상 빠른 전자이동도 등의 매우 우수한 특성을 지닌다. 그래핀을 합성하거나 얻는 방법에는, 기계적 박리법(Micro mechanical exfoliation), 산화흑연(graphite oxide)을 이용한 reduced graphene oxide(RGO)방법과 탄화 규소(SiC)를 이용한 epitaxial growth 방법 등이 있지만, 대 면적화가 어렵거나 구조적 결함이 큰 문제점이 있다. 반면, 탄화수소(hydrocarbon)를 탄소 공급원으로 하는 열화학 기상 증착법(Thermal chemical vapor deposition, TCVD)은 구조적 결함이 상대적으로 적으면서 대 면적화가 가능하다는 이점 때문에 최근 가장 많이 이용되고 있는 방법이다. TCVD를 이용, 니켈, 몰리브덴, 금, 코발트 등의 금속에서 그래핀 합성연구가 보고되었지만, 대부분 수 층(fewlayer)의 그래핀이 합성되었다. 하지만, 구리 촉매를 이용하는 것이 단층 그래핀 합성에 매우 효율적이라는 연구결과가 보고되었다. 구리의 경우, 낮은 탄소융해도(solubility of carbon) 때문에 표면에서 self limiting 과정을 통하여 단층 그래핀이 합성된다. 그러나 단층 그래핀 일지라도 면저항(sheet resistance)이 매우 높고, 이론적 계산값에 비해 전자이동도(electron mobility)가 낮게 측정된다. 이러한 원인은 구조적 결함에서 기인된 것으로써 산업으로의 응용을 어렵게 만들기 때문에 양질의 단층 그래핀 합성연구는 필수적이다[1,2]. 본 연구에서는 TCVD를 이용하여 구리 포일(25 ${\mu}m$, Alfa Aeser) 위에 메탄가스를 탄소공급원으로 하여 수소를 함께 주입하고, 메탄가스의 양과 합성시간, 열처리 시간을 조절하면서 균일한 단층 그래핀을 합성하였다. 합성된 그래핀을 $SiO_2$ (300 nm)기판위에 전사(transfer)후 라만 분광법(raman spectroscopy)과 광학 현미경(optical microscope)을 통하여 분석하였다. 그 결과, 열처리 시간이 증가할수록 촉매로 사용된 구리 포일의 grain size가 커짐을 확인하였으며, 구리 포일 위에 합성된 그래핀의 grain size는, 구리 포일의 grain size에 의존하여 커짐을 확인하였다. 또한 동일한 grain 내의 그래핀은 균일한 층으로 합성되었다. 이는 기계적 박리법, RGO 방법, epitaxial growth 방법으로 얻은 그래핀과 비교하여 매우 뛰어난 결정성을 지님이 확인되었다. 본 연구를 통하여 면적이 넓으면서도 결정성이 매우 뛰어난 양질의 단층 그래핀 합성 방법을 확립하였다.

  • PDF

Grain Boundary Character Changes and IGA/PWSCC Behavior of Alloy 600 Material by Thermomechanical Treatment (가공열처리에 의한 Alloy 600 재료의 결정립계특성 변화와 입계부식 및 1차측 응력부식균열 거동)

  • Kim, J.;Han, J.H.;Lee, D.H.;Kim, Y.S.;Roh, H.S.;Kim, G.H.;Kim, J.S.
    • Korean Journal of Materials Research
    • /
    • v.9 no.9
    • /
    • pp.919-925
    • /
    • 1999
  • Grain boundary characteristics and corrosion behavior of Alloy 600 material were investigated using the concept of grain boundary control by thermomechanical treatment(TMT). The grain boundary character distribution (GBCD) was analyzed by electron backscattered diffraction pattern. The effects of GBeD variation on intergranular at tack(JGA) and primary water stress corrosion cracking(PWSeC) were also evaluated. Changes in the fraction of coinci dence site lattice(CSL) boundaries in each cycle of TMT process were not distinguishable, but the total eSL boundary frequencies for TMT specimens increased about 10% compared with those of the commercial Alloy 600 material. It was found from IGA tests that the resistance to IGA was improved by TMT process. However, it was found from PWSCC test that repeating of TMT cycles resulted in the gradual decrease of the time to failure and the maximum load due to change in grain boundary characteristics, while the average crack propagation rate of primary crack increased mainly due to suppression of secondary crack propagation. It is considered that these corrosion characteristics in TMT specimens is attributed to 'fine tuning of grain boundary' mechanism.

  • PDF

Chromel-Alumel Thermoelectric Flow Sensor Fabricated on Dielectric(Si3N4/SiO2/Si3N4) Membrane (유전체(Si3N4/SiO2/Si3N4)멤브레인 위에 제작된 크로멜-알루멜 열전 유량센서)

  • Lee, Hyung-Ju;Kim, Jin-Sup;Kim, Yeo-Hwan;Lee, Jung-Hee;Choi, Yong-Moon;Park, Se-Il
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.103-111
    • /
    • 2003
  • A chromel-alumel thermoelectric flow sensor using $Si_3N_4/SiO_2/Si_3N_4$ thermal isolation membrane was fabricated. Temperature coefficient of resistance of thin film Pt-heater was about $0.00397/^{\circ}C$, and Seebeck coefficient of chromel-alumel thermocouple was about $36\;{\mu}V/K$. The sensor showed that thermoelectric voltage decreased as thermal conductivity of gas increased, and $N_2$-flow sensitivity increased as heater voltage increased or the distance between heater and thermocouple decreased. When heater voltage was about 2.5 V, $N_2$-flow sensitivity and thermal response time of the sensor were about $1.5\;mV/sccm^{1/2}$ and 0.18 sec., respectively. Linear range in flow sensitivity of the flow sensor was wider than that of Bi-Sb flow sensor.

Structures and Double Layer Performances of Carbons Pyrolized from Carbon Oxides (산화탄소로부터 열분해한 탄소의 구조 및 전기이중층 거동)

  • Kim, Ick-Jun;Yang, Sunhye;Jeon, Min-Je;Moon, Seong-In;Kim, Hyun-Soo;An, Kye-Hyeok
    • Applied Chemistry for Engineering
    • /
    • v.18 no.5
    • /
    • pp.522-526
    • /
    • 2007
  • Structural features and electrochemical performances of cokes pyrolized from oxidized cokes were examined, and compared with KOH-activated coke. Needle cokes ($d_{002}=3.5{\AA} $), having a graphene layer structure, were changed to a single phase of graphite oxide after oxidation treatment with an acidic solution having an $NaCLO_3$/needle coke composition ratio of above 7.5, and the inter-layer distance of the oxidized coke was expanded to $6.9{\AA} $ with increasing oxygen content. After heating at $200^{\circ}C$, the oxidized coke was pyrolized to the graphene layer structure with inter-layer distance of $3.6{\AA} $. However, the change of the inter-layer distance of the needle coke was not observed in the KOH activation process. On the other hand, an intercalation of electrolyte ions into the pyrolized coke, observed at first charge, occurred at 1.0 V, in which the value was lower than that of KOH-activation coke. The cell capacitor using pyrolized coke exhibited a lower internal resistance of $0.57{\Omega}$ in 1 kHz, and a larger capacitance per weight and volume of 30.3 F/g and 26.9 F/ml at the two-electrode system in the potential range 0~2.5 V than those of the cell capacitor using KOH-activation of coke. This better electrochemical performance may be associated with structure defects in the graphene layer derived from the process of the inter-layer expansion and shrinkage.

Experimental Study on the Behavior of Building Hardware with Joint Details (접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구)

  • Hong, Seonguk;Kim, Seunghun;Baek, Kiyoul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.190-198
    • /
    • 2018
  • In recent years, non-welded building hardware has been installed by bolt assembly is used. The non-welded building hardware method can reduce accidents caused by welding, and can be constructed by bolt assembly, which can reduce labor costs and shorten the construction period. However, there is a need for a method to compensate for the occurrence of buckling at the time of construction. The purpose of this study is to evaluate the behavior of joints between steel pipe and fastener and to evaluate the behavior of joints of non-welded and welded hardware frame. As a result, it was found that the foundation steel structure without welded joints was deformed to a rotation angle of member much larger than the allowable interlayer displacement angle 0.01 to 0.02 required according to the seismic load rating in the seismic load resistance system.

Characteristics of wild yeast isolated from non-sterilized Makgeolli in Korea (국내 생막걸리에서 분리한 야생 효모의 특성)

  • Jung, Su Ji;Yeo, Soo-Hwan;Mun, Ji-Young;Choi, Han-Seok;Baek, Seong Yeol
    • Food Science and Preservation
    • /
    • v.24 no.7
    • /
    • pp.1043-1051
    • /
    • 2017
  • Wild yeasts were isolated from domestic non-sterilized Makgeolli and their fermentation characteristics were analyzed to select the best fermentation seed culture. A total of 65 yeast strains isolated yeasts from non-sterilized Makgeolli and Nuruk. In order to select fermentable strains, hydrogen sulfide, $CO_2$ production ability, alcohol tolerance and aroma component production ability were analyzed. To screen the aromatic strains of isolates, media containing cerulenin, 5,5,5-trifluor-DL-leucine (TFL) and API ZYM kit were used. There were 36 strains resistance to cerulenin and all strains produced esterase and demonstrated tolerance against TFL. Hydrogen sulfide, which could degrade the quality of the fermented beverage, was not produced in 34 yeast. The correlation between alcohol tolerance of yeast and carbon dioxide production was analyzed by principal component analysis. YM22, YM31, YM32 and YM37 produced a total of 0.14-0.18 g/72 h of $CO_2$ indicating high fermentability. Alcohol tolerance was measured by alcohol concentration. YM32, YM37 yeast had 20% alcohol tolerance. As a result, alcohol and flavor characteristics of wild yeast isolated from non-sterilized Makgeolli were analyzed and it was confirmed that yeast was suitable for the production of alcohol.

A Study on the Mechanical Properties of Gas Pressure Welded Splices of Deformed Reinforcing Bar (가스압접 이형철근의 기계적 강도 특성 연구)

  • Jeon, Juntai
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.520-526
    • /
    • 2015
  • Reinforcing bar splices are inevitable in reinforced concrete structure. In these days, there are three main types of splices used in reinforced concrete construction site - lapped splice, mechanical splice and welded splice. Low cost, practicality in construction site, less time consuming and high performance make gas pressure welding become a favorable splice method. However, reinforcing bar splice experiences thermal loading history during the welding procedure. This may lead to the presence of residual stress in the vicinity of the splice which affects the fatigue life of the reinforcing bar. Therefore, residual stress analysis and tensile test of the gas pressure welded splice are carried out in order to verify the load bearing capacity of the gas pressure welded splice. The reinforcing bar used in this work is SD400, which is manufactured in accordance with KS D 3504. The results show that the residual stresses in welded splice is relatively small, thus not affecting the performance of the reinforcing bar. Moreover, the strength of the gas pressure welded splice is high enough for the development of yielding in the bar. As such, the reinforcing bar with gas pressure welded splice has enough capacity to behave as continuous bar.

Effects of Gamma-Ray and Heat Treatment on Sterilization of Escherichia coli O157:H7 (Escherichia coli O157:H7의 살균을 위한 감마선과 가열처리의 효과)

  • Kwon, Oh-Jin;Yook, Hong-Sun;Kim, Seong-Ai;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.1016-1020
    • /
    • 1997
  • Treatments of irradiation alone and/or in combination with heat were investigated for the sterilization of Escherichia coli O157: H7. D values of the strain were 129.2 min at $50^{\circ}C$, 27.1 min at $55^{\circ}C$, and 2.4 min at $60^{\circ}C$. The survival effect of E. coli O157:H7 during heating at various media was investigated. On heating at temperature of $60^{\circ}C$ for 10 min, the strain was generally more resistant in the media containg such chemical substrates such as 0.03 M cysteine, 1% sodium citrate or 5% sucrose, whereas this strain was appeared weaker in the chemical substrates added group such as 1% meat extract, 1% casein or 1% casamino acid. In the case of irradiation alone, $D_{10}$ value of E. coli O157:H7 was 0.116 kGy, and inactivation factors were $17{\sim}25$ at doses of 2 to 3 kGy. Pre-and post-irradiation heating showed the same $D_{10}$ value about 0.07 kGy. And Inactivation factors were $25{\sim}41$ at doses of 2 to 3 kGy. Therefore, combination treatment with heat and irradiation significantly increased in inactivation rate by increasing radiation sensitivity of E. coli O157:H7.

  • PDF

High-dose Intravenous Immune Globulin Retreatment in Kawasaki Disease (가와사끼병에서의 고용량 정주용 면역글로불린 재치료)

  • Shim, So Yun;Heo, Mi Young;Kim, Hae Soon;Sonh, Sejung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.10
    • /
    • pp.1273-1277
    • /
    • 2002
  • Purpose : To determine clinical features, laboratory findings and cardiac abnormalities of highdose immune globulin(IVIG) retreatment in patients with Kawasaki disease, and to report effectiveness of retreatment. Methods : Retrospective study of 174 children diagnosed with Kawasaki disease at Ewha Mokdong hospital from March, 1999 to July, 2001. Results : Twenty(11.5%) of 174 patients were retreated with high-dose IVIG. After this, only two patients(1.1%) did not respond to IVIG retreatment. Patients with failure to respond to initial IVIG did not differ from the patients who responded to a single course of IVIG in sex, age, days of fever at initial IVIG and clinical characteristics. Compared with responders with single IVIG treatment, the patients who were retreated had significantly lower albumin(3.7 vs 3.4 g/dL, P < 0.05), higher ALT(118.2 vs 229.3 U/L, P < 0.05) and CRP(8.9 vs 13.3 mg/dL, P < 0.05). On echocardiography, patients who recieved IVIG retreatment were significantly more likely to have caronary abnormalities(45.0% vs 13.6%, P < 0.05). Conclusion : Retratment with IVIG for persistent or recurrent fever was safe and effective.