• Title/Summary/Keyword: 저장탄약 신뢰성평가

Search Result 14, Processing Time 0.016 seconds

A development of the Automatic Measuring System for internal pressure of the artillery (화포 내부 압력의 자동 측정시스템 개발)

  • Lee, Jeong-Ho;Kim, Dong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.766-773
    • /
    • 2021
  • Chemicals, such as ammunition, are disposable items that cannot be reused because of their operational characteristics. The reliability of the test process and test results are important factors in evaluating the performance of guns and ammunition. The pressure after firing is a crucial value in an acceptance test of guns and ammunition performance; hence, accurate measurements are required. The pressure in the artillery is measured using the copper crusher gauge. The compression amount of copper is converted into a pressure by either a length-pressure conversion table or conversion formula. Therefore, the exact measurement of the squeeze of the copper crusher is related directly to the correct estimate of the pressure. Currently, the pressure is measured manually by the operator, which always includes some human error. In this study, the cause of the measurement error was analyzed, and the automatic measuring system for copper crusher deformation was developed to minimize the error elements. A copper crusher could be measured using the probe sensor and CCD camera, and the Jig for stable positioning was also designed. A designated SW was also developed for the system operating and measurement-analysis. This measuring system through this study may be used for an ammunition stockpile reliability test and gun/ammunition acceptance test.

A Study on the Estimation of Shelf Life for Fuze MTSQ KM577A1 from ASRP Data (저장탄약신뢰성평가 데이터를 이용한 기계식시한신관 KM577A1 저장수명 추정 연구)

  • Lee, Dongnyok;Yoon, Keunsig
    • Journal of Applied Reliability
    • /
    • v.18 no.1
    • /
    • pp.56-65
    • /
    • 2018
  • Purpose: The purpose of this study is to estimate shelf life of fuze MTSQ (Mechanical Time & Super Quick) KM577A1 from Ammunition Stockpile Reliability Program (ASRP) data. Methods: For many years, ammunition test data had been gathered from ASRP. In this study, lot selection criteria and reliability score of functioning time for fuze are proposed. Reliability score of functioning time and failure data are used to estimate shelf life. Results: The results of this study are as follows; The failure modes of fuze MTSQ KM577A1 are dud, inverse function and mechanical time functioning failure (not operating in intended time). Dud and inverse function are major failure modes. Fuze MTSQ KM577A1's shelf life ($B_5$) is estimated 18.2 years conservatively. Conclusion: Degradation of chemical components in fuze MTSQ KM577A1 is major factor for its reliability. And shelf life ($B_5$) of fuze MTSQ KM577A1 is estimated 18.2 years conservatively.

A Study on the shelf-life of IR screening smoke launcher grenade (적외선 차장 연막유탄 신뢰도 및 저장수명 연구)

  • Lee, Jongchan;Lee, Junhyuk;Jung, Hyunsuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.437-445
    • /
    • 2020
  • Smoke grenades are the primary means of protection used by tanks to disrupt enemy detection systems. Such smoke grenades are a critical factor that determines the survival of tanks in the engagement of ground weapon systems, but it can only be used once. Owing to its destructive property, the performance and safety of the smoke grenade cannot be confirmed prior to use. Therefore, the reliability of smoke grenades can be evaluated through various tests during the storage period. This paper presents the results of estimating the reliability and shelf life of IR screening smoke grenade launchers based on the result of the Ammunition Stockpile Reliability Program conducted in 2019. Among the smoke grenade launcher lots currently stored, 16 lots and samples were selected for each year of manufacture and tested. The reliability and shelf life were estimated by examining the number of defects and the change in quality characteristics of each test item. The results of this study can be used to assess the reliability of the smoke grenade launchers and to improve the quality of manufacturing sites.

A Case Study of Six Sigma for Improving Non-Function Test Process in the Ammunition Stockpile Reliability Program (저장탄약신뢰성평가의 비기능시험 업무프로세스 개선을 이한 6시그마 적용 사례 연구)

  • Yoon, Keun-Sig;Kim, Yong-Hwa;Bong, Ha-Gyu;Lee, Jong-Chan
    • Journal of Korean Society for Quality Management
    • /
    • v.34 no.4
    • /
    • pp.13-21
    • /
    • 2006
  • This paper includes an example of applying Six Sigma to Non-function test process to improve the efficiency and reliability of the Ammunition Stockpile Reliability Program (ASRP). By applying the DMAIC which is one of the Six sigma methods. we found out the vital few and as an improved version : effective redesign of check-sheets, pre-examination of technology, on-the-scene support system. As a result, we could enhance the reliability and reduce manpower and additional expenses.