열상장비용 스터링 극저온 냉동기 특성평가 (II) : 수명시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (II) : Life test)

  • 홍용주;박성제;김효봉;김양훈;권영주
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 2003
  • The needs for the cryocooler which has high reliability and long MTTF are increased in the military and commercial thermal imaging system The gas contamination wear, leakage of the working fluid, fatigue and etc. have the significant effects on the reliability and MTTF(Mean Time To Failure) or MTBF(Mean Time Between Failure) of the Stirling cryocooler. In the KIMM, the Stilting cryocooler with the linear compressor was released after the several performance tests were performed. This paper describe the experimental facility for the MTTF evaluation and some typical results of the Stilling cryocooler.

  • PDF

관성관 맥동관 냉동기의 성능에 관한 해석적 연구 (The Study of the performance analysis of the inertance Pulse Tube refrigerator)

  • 홍용주;박성제;김효봉;최영돈
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.159-162
    • /
    • 2003
  • Cooling with easy, reliable cryocooler is highly desirable for the commercial and military application The pulse tube refrigerator has no moving parts at the cold end, so that the mechanical vibration and magnetic noise can be reduced to the low level with higher relaibility and longer lifetime than the Stilting cryocooler. The inertance tube improve the performance of pulse tube refrigerator by providing optimal phase shift between pressure and amss flow rate, and it is easiest to implement at large cooling capacity and high operating frequency. In this study, the performance of the inertance pulse tube refrigerator was investigated by analysis. The results show the influence of the diameter and length of the inertance tube on the performance of the refrigerator.

  • PDF

1 kW급 역브레이튼 극저온 냉동기 개발에 관한 연구 (A Study on 1 kW Development of Reverse Brayton Cycle Cryocooler System)

  • 권용하;박재홍;정종환;김영수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.176-180
    • /
    • 2003
  • To obtain superconducting state, a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor recuperator, coldbox, control valves and has 1 ㎾ cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation (MLI) and high vacuum. The results can be summarized as; conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (I) : 성능시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (II) : Performance test)

  • 박성제;홍용주;김효봉;김양훈;이성래;이기백;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.320-323
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the cooling capacity / applied input power and cool down time are investigated. This cooler delivers approximately 0.9W cooling at 80K for 30W ~ 40W of input power. And, It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (IV) : 진동, 소음, 누설시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (IV) : Vibration, Noise, Leak test)

  • 박성제;홍용주;김효봉;김양훈;최상규;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.167-170
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the vibration, acoustic noise, EMI and leak rate are evaluated. Vibration outputs are measured to 20KHz for compressor and expander, respectively. And, the objective of noise test is a noise level, less than 30㏈ at 5 m. EMI tests are carried out according to the standard MIL-STD-461C tests RE01 and RE02. Leak test for the Stilting cryocooler is performed by bombing method.

  • PDF

회전하는 맥동관 냉동기의 맥동관에 대한 2차원 모델 해석 (Two-dimensional model analysis for the pulse tube of rotating pulse tube refrigerator)

  • 최재영;정상권;정은수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.63-69
    • /
    • 2006
  • This paper describes the effect of rotating frequency on the pulse tube of Stirling type pulse tube refrigerator. Various conditions were analyzed by two-dimensional analysis with several dominant non-dimensional parameters. With the additional pressure term influenced by centrifugal force in rotating condition, the linearized conservation equations of mass, momentum, energy of the gas were solved to obtain the first order variables and calculate the enthalpy flow in rectangular coordinates. The rotational effect in pulse tube for the refrigerator's performance were quantitatively evaluated. According to the first order analysis, the enthalpy flow decreases with the rotating speed.

일체형 스터링 냉동기 성능에 미치는 주요 인자에 관한 연구 (A Study on the Principal Factors for the Stirling Refrigerator Performance)

  • 김대웅;박성제;홍용주;김효봉;고상철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.67-70
    • /
    • 2008
  • Performance of integral type Stirling refrigerator used for cooling infrared detector is affected by principal factors such as design factors and operating factors. Operating factors include charging pressure and operating frequency. The purpose of this paper is to examine the basic design analysis on the integral type Stirling refrigerator and the changes in performance through experiments on operating factors.

일체형 스터링 냉동기의 설계, 제작 및 성능특성에 관한 연구 (A study on the performance characteristics of rotary type Stirling cryocooler)

  • 박성제;홍용주;김효봉;김양훈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권1호
    • /
    • pp.54-58
    • /
    • 2006
  • Stirling cryocooler is relatively compact, reliable, commercially available. and uses helium as a working fluid. Over the past decade and a half, there has been rapid development of Stirling cryocooler, mainly for military and space applications. Stirling cryocoolers have been widely used lot the cooling of infrared sensors and high temperature superconducting filters to the temperature of the liquid nitrogen. The Stirling cryocooler with the rotary compressor is applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. In this paper, integral Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.6W cooling at 80K for 20W of input power from 24V DC power supply.

Triplet 열교환기를 사용하는 소형 J-T 냉동기 (Miniature J-T Refrigerator Using Triplet Heat Exchanger)

  • 황규완;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.60-63
    • /
    • 2009
  • Most J-T (Joule-Thomson) refrigerators use a Giaque-Hampson type heat exchanger due to its excellent thermal performance and compactness. The cryoprobe (cryosurgical probe) treating prostate cancer usually has a dimension of 17 gauge (1.6 mm diameter), so it does not have enough space to bear a Giaque-Hampson type heat exchanger. In this paper, the triplet heat exchanger is adopted as the heat exchanger of cryoprobe, and the performance is investigated with an experimental test. The result shows that the triplet heat exchanger can be substituted for Giaque-Hampson type heat exchanger in the application of cryosurgery.

1984~1985년의 미국100대 발명, 발견

  • 한국과학기술단체총연합회
    • 과학과기술
    • /
    • 제19권1호통권200호
    • /
    • pp.48-57
    • /
    • 1986
  • - DATA파이프 - 화학품 생산을 위한 바이오매스의 이용 - 선형 프로그래밍 산법 - 복합질병을 위한 왁찐 - 말라리아 왁찐 - 데이터 기록용의 확장식 디스크매체 - 생세포의 냉동보존용 전산화 시각분석법 - 콜버그완 - 중유회수의 능률향상 - 충돌 들뜸체계이용 소프트 X선 레이저 - 스터얼링 사이클 저온 냉각기 - 셀데인 - 플라즈마 체계이용 소프트 X선 레이저 - 수력터빈 시스템 - 암호시스템을 해독하는 산법 - 균일한 크기의 극히 미세한 물질을 형성하는 공정 - 마그네켄치 - 리그닌 퇴화효소 - 코즈믹 튜브 - 테라비트 Km/Sec용량의 광전송 - 폴리머-세라믹 복합체 - 노바 - 살아있는 뇌의 신경 수용체를 보고 측정하는 방법