• 제목/요약/키워드: 저온냉동

검색결과 210건 처리시간 0.019초

2단 냉동기의 냉각시간 단축을 위한 기체-간극 열스위치 설계 (Design of gas-gap thermal switch for reducing cooldown time of 2-stage cryocooler)

  • 김형진;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2000
  • A preliminary design of gas-gp thermal switch is presented to reduce the cooldown time of superconducting system conduction-cooled by a two-stage refrigerator without liquid cryogens. The switch connects thermally the first and the second stages (ON) to take advantage of the larger refrigeration capacity at the first stage during the beginning period. After the cryogenic temperature is reached, the switch should isolate thermally the two stages (OFF) in order to reduce the heat leak to the cold end. In this paper, a new concept for the performance index is introduced to evaluate the reduction of the cooldown time and the increase of the cooling load at the same time. In addition, the design of a gas-gap switch is discussed as a closed container of several staggered concentric tubes filled with gas, which is frozen at low temperatures for the shut-off of heat without any mechanical actuation. Some of the detailed features in the design is quantitative investigated by the gas convection model in the continuum or the rarefied gas region.

  • PDF

적외선 센서 냉각용 스터링 냉동기의 수명/신뢰성 시험 (Reliability Test of the Stirling Cryocooler for cooling infrared detector)

  • 박성제;홍용주;김효봉;유병건;이기백
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.156-159
    • /
    • 2003
  • A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.5W cooling at 77K for 30W ∼ 40W of input power from AC power supply. And, after the climate performance and reliability for the cryocooler is discussed, operating test without cooling load at the cold end is performed.

  • PDF

소형 관성관 맥동관 냉동기의 단열 해석 및 성능 실험 (Adiabatic analysis and performance experiment of miniature inertance pulse tube refrigerator)

  • 남중원;남관우;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.28-32
    • /
    • 2003
  • Miniature inertance pulse tube refrigerator was designed and fabricated to provide optimal performance with 10W compressor. An adiabatic model was used to design an inertance pulse tube refrigerator. Among the various design parameters which should be optimized, pulse tube length and inertance tube length were considered. PdV work and various losses were calculated for various pulse tube and inertance tube length. Experiments were carried out for different pulse tube length and inertance tube length. It was shown that the experimental results were similar to the calculated results. The reason why the quantitative optimal point exists is explained.

  • PDF

관성관형 동축 맥동관 냉동기의 특성에 관한 연구 (The study of the Characteristic of the Coaxial Type Inertance Pulse Tube Refrigerators)

  • 김양훈;박성제;홍용주;김효봉;이승홍
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.33-35
    • /
    • 2003
  • There are three types that geometrical arrangement of the pulse tube and regenerator - in line type, U type, and coaxial type. The most compact and convenient one practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. To investigate effects of the inertance tube, we perform experiments with varying inertance tube inner diameter and length. The experimental results show that optimum inertance tube inner diameter and length are 1.3mm, 1900mm respectively.

  • PDF

스터링 냉동기의 선헝압축기 운전특성에 관한 수치해석적 연구 (Numerical Analysis of Performance of Linear Compressor for the Stilting Cryocooler)

  • 홍용주;박성제;김효봉;염한길;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.58-62
    • /
    • 2002
  • The purpose of this study is to analyze the charging gas effect on the resonance and performance characteristics of the linear compressor for small scale FPFD Stirling refrigerator. To ensure high performance of FPFD type Stirling refrigerator, the operating frequency of the refrigerator should be around the natural frequency of compressor. The gas spring effect which is induced from Pressure change in cylinder due to motion of pistons has significant effect on the natural frequency of the compressor. The numerical results show the linear compressor has high natural frequency when the charging pressure of working fluid is high and the stroke of compressor, current, input power and efficiency of compressor were shown with different operating conditions.

스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구 (Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

극저온냉동기 직냉형 진공시스템의 냉동부하 평가 (Evaluation of the required cooling capacity of the Cryocooler in the vacuum system)

  • 홍용주;박성제;김효봉;최영돈
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.171-173
    • /
    • 2003
  • The cryostat or dewar have been widely used for making and maintaining cryogenic and vacuum environments. The thermal performances of such cryogenic vacuum system mainly depend on the radiation heat transfer between hot and cold surface The characteristics of radiation heat transfer are complicated, because amounts of heat transfer depend on view factor, emissivities, and areas of thermal elements. In this study, the analysis of the radiation heat transfer in the small cryogenic vacuum system was performed using the surface to surface radiation model for evaluation of the required cooling capacity of the cryocooler.

  • PDF

GM 냉동기를 이용한 네온 액화기 제작 (I) (Neon liquefier system using GM cryocooler (I))

  • 권운식;손명환;백승규;이언용;권영길;권용덕
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.266-268
    • /
    • 2003
  • The neon liquefier by using GM cryocooler is designed and in process of manufacturing for the cooling of 100 hp high temperature superconductor (HTS) motor. It was used the principle of thermosyphon that the rotor of the motor is cooled by the latent heat of liquidized neon. The cold-box was designed to minimize heat loss by conduction, convection, radiation. Two heat exchanger were made to liquefy neon by the direct contact of neon gas on the cold head. As a first stage of our project, evaporation apparatus will be setup in the inner field of the cold-box and then the performance of neon liquefier will be test.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

고온 초전도 회전자 냉각을 위한 탑재형 맥동관 냉동기 연구 (Investigation on-board pulse tube refrigerator for high temperature superconducting rotor)

  • 남중원;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.316-319
    • /
    • 2003
  • Cryogenic refrigerator system is necessary for cooling the superconducting rotor. Among the various cryogenic refrigerator systems, on-board hybrid pulse tube cryocooler is designed for cooling the superconducting rotor. Hybrid pulse tube cryocooler is composed of pulse tube cryocooler and Stirling cryocooler. This Stirling cryocooler precools the middle point of regenerator to obtain lower temperature at cold part of pulse tube cryocooler. In this paper, only Stirling cryocooler is on-boarded then rotated by motor for various rotating speeds and heat loads at cold part of Stilting cryocooler. Through this experiment the feasibility of the on-board cryocooler is investigated.

  • PDF