• Title/Summary/Keyword: 저압 조건

Search Result 186, Processing Time 0.032 seconds

Photo-Induced Chemical Vapor Deposition of $SiO_2$ Thin Film by Direct Excitation Process (직접 광여기 Photo-CVD에 의한 이산화실리콘 박막의 증착 특성)

  • Kim, Youn-Tae;Kim, Chi-Hoon;Jung, Ki-Ro;Kang, Bong-Ku;Kim, Bo-Woo;Ma, Dong-Sung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.7
    • /
    • pp.73-82
    • /
    • 1989
  • We developed a photo-CVD equipment for the deposition of silicon based insulating materials. Silicon dioxide thin films were deposited at various process conditions especially low temperature range $50-250^{\circ}C$. Low pressure mercury lamp was used in the direct excitation of $SiH_4/N_2O$ mixture gas without mercury sensitization. AES and ESCA analysis showed that oxygen to silicon atomic ratio and binding state of Si-O bond was nearly 2.0 and $SiO_2$ type, respectively. The refractive indices were measured to be 1.39-1.44, indicating that films were in relatively low density.

  • PDF

Low Temperature Recrystallization of Self-Implanted Amorphous Silicon Films (저온공정에 의한 자기이온주입된 비정질 실리콘 박막의 재결정화)

  • Lee, Man-Hyeong;Choe, Deok-Gyun;Kim, Jeong-Tae
    • Korean Journal of Materials Research
    • /
    • v.2 no.6
    • /
    • pp.417-427
    • /
    • 1992
  • Silicon ion implantation was performed to LPCVD amorphous Si films and the low temperature annealing process followed with various conditions to find the optimal physical properties by studying recrystallization behavior. The uniformity of the recrystallized films was inspected by optical microscopy and for this purpose, new KOH: (IPA) : $H_2$O: $K_2$C${r_2}{O_7}$, etchant was developed. XRD and TEM results showed that the crystallites were grown as a form of dendrite with (111) preferred orientation, and the grain size was increased with dose concentration. The maximum grain size was obtained when the 3${\times}{10^{15}}$c$m^2$ implanted amorphous Si film was recrystallized at 55 $0^{\circ}C$for more than 40 hrs and at this condition the grain size was 3.2${\mu}$m.

  • PDF

Optimization Study for Pressure Swing Distillation Process for the Mixture of Isobutyl-Acetate and Isobutyl-Alcohol System (Isobutyl-Acetate와 Isobutyl-Alcohol 이성분계의 압력변환증류 공정 최적화 연구)

  • Cho, Sung Jin;Shin, Jae Sun;Choi, Suk Hoon;Lee, Euy Soo;Park, Sang Jin
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.307-313
    • /
    • 2014
  • In this study, an optimization process design has been performed to separate 99.9 mol% of Isobutyl Acetate from binary azeotropic mixture of Isobutyl Acetate and Isobutyl Alcohol system using a Pressure Swing Distillation (PSD). PSD is used to separate binary azeotropic mixtures using the difference between the relative volatilities and azeotropic compositions by changing the system pressure. Non-Random Two Liquid (NRTL) model for liquid phase and the Peng-Robinson equation for vapor phase are used. An optimization study for the reflux ratio and feed stage locations which minimize the total reboiler heat duties are studied. Since PSD process consists of two columns, i.e. high pressure and low pressure, the effect of column sequence on the optimum conditions is reported.

Study on Component Map Generation and Performance Simulation of 2-spool Separate Flow Type Turbofan Engine Using SIMULINK (SIMULINK를 이용한 2-스풀 분리형 배기방식 터보팬 엔진의 구성품 성능맵 생성 및 성능모사에 관한 연구)

  • Kong, Changduk;Kang, MyoungCheol;Park, Gwanglim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.1
    • /
    • pp.70-79
    • /
    • 2013
  • In this work, a steady-state performance modeling and off-design performance analysis of the 2-spool separate-flow turbofan engine named (BR715-56) which is a power plant for the narrow body commercial aircraft is carried out for engine performance behaviors investigation and condition monitoring using a commercial code MATLAB/SIMULINK. Firstly, the engine component maps of fan, high pressure compressor, high pressure turbine and low pressure turbine are generated from similar component maps using the scaling method, and then the off-design performance simulation model is constructed by the mass flow matching and the work matching between components. The model is developed using SIMULINK, which has advantages of easy steady-stare and dynamic modelling and user friendly interface function. It is found that the off-design performance analysis results using the proposed model are well agreed with the performance analysis results by GASTURB at various operating conditions.

Examination of Conductor and Sheath Temperatures Dependent on the Load Currents through High-Power Live Cables at a Power Station (발전소에서 활선 고전력 케이블의 운전 부하전류에 따른 도체 및 피복표면의 온도 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.213-218
    • /
    • 2017
  • High-voltage power systems operate in order to generate and transmit electric power at power stations. Compared to low-power systems, high-power systems are complex in structure, large-scale, and expensive. When high-power cable accidents occur, most facilities are incapacitated-including low-power systems-causing huge economic losses. Great care must therefore be taken in designing, installing and managing power systems. Although dependent on installation circumstances and usage conditions, in some cases the cross-sectional areas of cables fall short of the critical area due to the expansion of and improper design and installation of power facilities. In this situation, the exceeded ampacity (allowable current) above the critical value caused by the operating current initiates the deterioration processes of power cables. In order to systematically monitor power cables operating at power stations, we have developed the first device of its kind in Korea. In this paper, we present the analyzed characteristics of expected temperatures of cables based on the load current of high-voltage cables operating at Korean Western Power Co. Ltd. We can predict the lifetime of cables by analyzing the temperature obtained from our device.

Measurements of Load Current of XLPE Cables Installed at the Load Terminal of Turbine Generator in Operation at Thermoelectric Power Station (화력 발전소의 터빈 발전기 부하단에 설치된 XLPE 케이블의 부하전류 측정)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.207-212
    • /
    • 2017
  • The cables installed to deliver high electric power from a generator at a thermoelectric power station are XLPE (or CV) cables. Depending on the installation and usage conditions, the cables in operation start deteriorating from the time of initial operation. Some cables can cause accidents due to faulty construction or other environmental factors. In order to prevent cable accidents, regular auditing of power cables is required. We have invented a measuring device for systematic surveillance and prevention of accidents, and installed the device at Korean Western Power Co. Ltd. which measures load currents through the cables. In this paper, we present the load current measured using our device, analyze the load characteristics by measures current, compare the ampacity defined by IEC standard, and present a basic data to obtain the temperature of cable conductors.

An experimental study on development of water mist fire-fighting systems for Ro-Ro spaces (Ro-Ro 구역용 미분무 소화설비의 개발을 위한 실험적 연구)

  • Kwark, Ji-Hyun;Kim, Young-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.946-952
    • /
    • 2013
  • Large scale fire tests were conducted to develop water mist nozzles as a component of fixed water- based fire fighting systems for Ro-Ro spaces and special category spaces. Fire scenarios for this system consist of two cases which are for cargo fire in a simulated truck and for passenger vehicle fire, and each case has 3 different tests according to the position between fixed water mist nozzles and fire source. Every experiment proceeded for 30 minutes and acceptance criteria were based on gas temperature, fuel package's damage and ignition of targets. This study primarily dealt with the experimental results of cargo fire and focused on fire suppression capability in accordance with discharge pressure, flow rate and flow characteristics like swirl and penetration of the developed water mist nozzles. It appeared that low pressure water mist nozzles with about 40 L/min were able to control fire occurred in Ro-Ro spaces.

Study on the Membrane Cleaning-in-place (CIP) Conditions for the Dye Wastewater Treatment Process Using Polyamide Composite Membranes (폴리아마이드계 복합막을 이용한 염료 폐수 처리 공정 분리막 세척 조건 연구)

  • JeGal, Jong-Geon;Lee, Yong-Hwan;Hwang, Jeong-Eun;Jaung, Jae-Yun
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.94-102
    • /
    • 2008
  • For the treatment of the dye wastewater, a polyamide nano-composite membrane and reverse osmosis (RO) membranes were prepared using interfacial polymerization technique, in which piperazine, meta-phenylene diamine, and trimesoyl chloride were used as monomers, Their permselective properties were characterized with aqueous solutions of PEG 600, $Na_2SO_4$, and NaCl, and their performance was compared with that of Osmonics Co, They were found to be a typical nano-composite membrane and a low pressure RO membrane. Using them, a real dye wastewater supplied from the Kyungin Corporation, one of the domestic dye producer, was treated, studying the separation performances of the membranes, Also, during the wastewater treatment, cleaning in place (CIP) of the membranes was carried out regularly to recover the flux of the membranes. Three different chemical cleaners were employed for the CIP process and their performance were compared in this study.

Adsorption Characteristics of n-Butane and 1-Butene on Mesoporous MCM-41 Containing Silver Ions (은이온이 담지된 메조포러스 MCM-41을 이용한 n-부탄과 1-부텐의 흡착 특성 연구)

  • Kang, Min;Lee, Hyung Ik;Yoon, Dal Young;Ko, Chang Hyun;Kim, Jong-Nam;Kim, Ji Man
    • Korean Chemical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.393-398
    • /
    • 2006
  • There have been a lot of works in order to develop an excellent adsorbent for separation of olefin and paraffin. In the present work, the adsorption characteristics of mesoporous MCM-41 containing silver ion for 1-butene and n-butane were studied. The adsorption ability for the 1-butene depending on thermal treatment were also investigated.MCM-41 exhibits much higher adsorption amounts for 1-butene as well as n-butane, compared to those of Ag/13X zeolite. In case of MCM-41 containing silver ion, the adsorption amount of 1-butene dramatically increased due to the ${\pi}$-complexation, whereas the adsorption amount of n-butane decrease. The Ag/MCM-41 after the thermal treatment at 373 K under evacuation exhibit the highest 1-butene/n-butane adsorption ratio, expecially at low pressure (100 Torr).

Finite Element Analysis on Polyethylene Gas Pipes under External Loadings (폴리에틸렌 가스배관의 외부 하중에 대한 유한요소 해석)

  • Kil, Seoog-Hee;Park, Kyo-Shik;Kim, Ji-Yoon
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.204-211
    • /
    • 2008
  • Polyethylene(PE) pipes have been widely used as they are easy to construct and suitable for economical efficient when they are compared with metal pipelines. This paper studied the effect of various external loadings on stress and deflection of the buried PE pipes using Finite Element Method(FEM). For this purpose, stresses of buried PE pipes were calculated according to the loading condition such as pipe types(pipe diameter $50{\sim}400mm$), burial depths($0.6{\sim}1.2m$) and internal pressures($0.4{\sim}4bar$). As a result, it was founded the effect and relation with each of loading conditions under the buried condition.