• Title/Summary/Keyword: 저감 효율

Search Result 1,951, Processing Time 0.033 seconds

발전설비에서 $CO_2$ 배출 저감 및 에너지 효율 향상 방안

  • Jo, Hyeong-Hui;Kim, Gyeong-Min
    • Journal of the KSME
    • /
    • v.51 no.5
    • /
    • pp.30-32
    • /
    • 2011
  • 이 글에서는 국내 발전설비와 관련하여 이산화탄소 배출량 및 이산화탄소를 줄이기 위한 기술 현황을 소개하고, 신기술 사용에 따른 에너지 효율 향상 및 $CO_2$ 배출 저감 방안에 대하여 기술하고자 한다.

  • PDF

Characteristics of NOx Reduction and NH3 Slip in SNCR Using Pipe Nozzle for the Application of Hybrid SNCR/SCR Process (Hybrid SNCR/SCR 탈질공정에서 SNCR의 관통노즐에 의한 NOx 저감 및 NH3 Slip 특성)

  • Hyun, Ju Soo
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.111-118
    • /
    • 2009
  • A hybrid SNCR/SCR plant was designed and manufactured, and experimented on the SNCR process in the first step to investigate the optimum operation conditions of SNCR, with the equivalence ratio of the reducing agent(NSR, 0.5~5.0), reaction temperature($850{\sim}1,100^{\circ}C$), nozzle type(wall nozzle, pipe nozzle), and nozzle position as variables. In the case of wall nozzles, the NOx reduction efficiency rapidly increased to 87% at 2.5 NSR and slowed down after this. Compared to the upward spray from the pipe nozzle, wall nozzles have narrower range of applicable reaction temperature. In the case of pipe nozzles, it rapidly increased to 77% at 1.5 NSR. But the pipe nozzle downward had no NOx reduction efficiency; on the contrary, NOx increased. When the reducing agent was sprayed upward from a pipe nozzle, the NOx reduction efficiency was 50~75% in the range of 0.5~1.5 NSR, and the NOx reduction efficiency was constant without fluctuations even in the change of reaction temperature from 890 to $1,000^{\circ}C$. When 5% urea solution was sprayed upward from the pipe nozzle, 200 ppm NOx decreased to approximately 60 ppm at 1.2 NSR, and the non-reacted $NH_3$ was 50~100 ppm. In this condition, we expect over 90% NOx reduction efficiency without additional supply of $NH_3$ to SCR at the back of SNCR.

Comparison of system efficiency and thermal analysis about single phase 3-level PFC converter with variation of switching modulation (단상 3레벨 PFC 컨버터의 모듈레이션 기법에 따른 효율비교 및 열해석)

  • Yeo, Si-Jun;Baek, Seunghoon;Cho, Younghoon;Choe, Gyuha
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.229-230
    • /
    • 2017
  • 본 논문은 단상 3레벨 PFC 컨버터에 적용하는 두 가지 모듈레이션 기법에 따른 시스템 효율 및 스위치 발열을 비교하고, 열해석 시뮬레이션을 통한 열 분포에 대한 결과를 기반으로 적절한 방열기법 모색을 위한 근거자료를 제시한다. 제안하는 모듈레이션 기법을 통해, 주 스위치인 SiC MOSFET의 도통손실을 저감하여 시스템 효율을 향상시키며, 스위치에 발생하는 열을 저감시킨다. 앤시스 열해석 시뮬레이션을 통해 이를 확인하고, 실험을 통해 검증한다. 정격부하(5kW)에 대해 약 $27^{\circ}C$의 스위치 온도저감이 이루어졌으며, 전 부하(0.5kW ~ 5kW)에 걸쳐 약 1%의 효율이 향상되었음을 실험을 통해 확인하였다.

  • PDF

Analysis of Efficient Pollution Reduction Facility using Pollutant Distribution Analysis (오염원 분포를 고려한 효율적 오염저감시설 적지분석)

  • Lee, Ji-Heon;Bae, Myung-Soon;Lee, Sang-Gil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.465-469
    • /
    • 2008
  • 수도권의 중요한 상수원인 팔당호 수질에 큰 영향을 주고 있는 경안천 유역의 오염배출량을 저감하기 위하여 많은 인공습지조성이 계획되었으나 이들의 위치선정의 적합성에 대한 분석이 부족한 실정이다. 또한 경안천은 상류에서 중류까지는 주변 농경지의 용수공급을 위해 많은 수중보가 설치되어 물의 흐름이 단절되어있어 수리적 요소에 인공요인으로 작용하고 있으며, 하류로 갈수록 하천이 곡선형태로 흐르고 하폭 또한 넓어져 자체적으로 유기물이 증가하기 좋은 환경을 가지고 있다. 본 연구에서는 유역의 자연적, 인공적 요소를 고려한 물리적 모델을 구축하고 각 오염원특성별 부하량 분석을 통한 속성정보를 반영하였으며 오염저감시설설치 시나리오의 타당성분석을 분석을 수행하였다. 연구과정을 좀더 상세히 살펴보면 첫째, 비점오염원의 주된 경로중 하나인 축산계부하량 저감을 위하여 지형적 인자를 고려한 인공습지조성 적지분석 결과를 HSPF모델에 반영하였다. 둘째, 기존 오염 총량제에서 수행해오던 오염부하량 산정방식을 통해 산정된 양을 유역단위로 재분배 하여 오염원 분포를 반영하였다. 주요 오염부하량인 축산계와 토지계의 오염부하량만을 적용하였으며 일부 오염원 항목들은 생략하거나 하수처리시설을 통해 처리되고 있는 것으로 모의하였다. 셋째, 각 시나리오별 시뮬레이션을 수행하여 경안천 인공습지조성가능성 및 수질개선 효과를 예측하였다. 기존의 점오염원 처리시설만으로는 하천에서의 목표수질을 만족시키는데 한계가 있기 때문에 점오염원 저감시설뿐 아니라 비점오염원 저감시설인 인공습지를 기존의 처리시설에 연계하여 시나리오를 구성하였다. 기존습지시설의 오염저감율은 각 시설들의 평균값을 적용하였으며 처리효율은 BOD, TN, TP 각각 40%, 25%, 12%로 적용하였다. 오염원분포를 고려한 모의결과 현재 인공습지 입지대상지역들 중 좀 더 효율적인 오염저감 효과를 보이는 지역이 분석되었다.

  • PDF

Lifecycle cost assessment of best management practices for diffuse pollution control in Han River Basin (한강수계 비점오염원 저감시설의 생애주기비용 평가)

  • Lee, Soyoung;Maniquiz-Redillas, Marla C.;Lee, Jeong Yong;Mun, Hyunsaing;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.448-455
    • /
    • 2016
  • Diffuse pollution management in Korea initiated by the Ministry of Environment (MOE) resulted to the construction of pilot facilities termed Best Management Practices (BMPs). Twelve BMPs installed for the diffuse pollution management in the Kyung-An Stream were monitored since 2006. Data on the mass loading, removal efficiency, maintenance activities, etc. were gathered and utilized to conduct the evaluation of long-term performance of BMPs. The financial data such as actual construction, design and maintenance cost were also collected to evaluate the lifecycle cost (LCC) of BMPs. In this study, most of the maintenance activity was focused in the aesthetic maintenance that resulted to the annual maintenance cost of the four BMP types was closely similar ranging from 8,483 $/yr for retention pond to 8,888 $/yr infiltration system. The highest LCC were observed in constructed wetland ($418,324) while vegetated system had the lowest LCC ($210,418). LCC of BMPs was not so high as compared with the conventional treatment facility and sewage treatment plant. On the other hand, the relationship of removal efficiency on unit cost for TSS and TN was significant. This study will be used to design the cost effective BMP for diffuse pollution management and become models for LCC analysis.

Reduction of Radiated Noise by Eigen-property Control (구조물의 고유특성 제어를 통한 방사 소음 저감)

  • 최성훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.376-382
    • /
    • 2004
  • The interaction between a vibrating structure and a surrounding acoustic medium determines the acoustic power propagating into the far-field. A straightforward method to reduce the radiated power is to reduce the vibration of the structure. However it is more efficient to control the modes of the structure separately since each vibration mode of the structure has different radiation efficiency. An efficient method to reduce the sound radiation in the low frequency region is proposed by reducing the radiation efficiency of the structure. Numerical simulations are carried out for a simply-supported beam in which the feed-forward control is applied to reduce the volume velocity of each structural mode. This method is found to be very efficient in reducing low frequency sound radiation.

Trapping Efficiency of Vegetative Filter Strip: Effect of Type and Height (식생대 특성에 따른 유출토사 저감 효율 : 식생의 종류와 높이)

  • Chang, Moonjeong;Son, Minwoo;Byun, Jisun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.206-206
    • /
    • 2019
  • 이 연구는 유출토사량의 저감을 위해 설치되는 식생대의 특성에 따른 효율을 살펴보는 것을 목적으로 한다. 검토하는 식생대의 특성으로는 식생의 종류와 식생대의 높이가 포함된다. 식생대의 효율을 평가하기 위해서는 VFSMOD-W 프로그램을 이용한다. 식생대가 적용되는 대상지역은 금강의 지류인 금마천이다. 금마천 유역은 나지를 다수 포함하고 있어 식생대의 설치에 따른 변화를 잘 살펴볼 수 있는 지역으로 판단된다. 해당 지역에서의 강우량은 시간당 최대강우량이다. 식생대의 특성을 나타내기 위해 보정되는 매개변수는 조고이며 VFSMOD-W 프로그램에서 제공하는 식생의 종류를 입력하였다. 사용된 프로그램에서는 식생대의 간격, 규모 등을 고려할 수 있므려 총 36개 종류의 식생대가 검토된다. 본 연구의 결과를 통해서 가장 먼저 나타나는 점은 식생대의 설치간격이 좁아질 때 보다 많은 양의 토사를 저감할 수 있다는 것이다. 하천으로 유출되는 유역토사의 저감을 식생대를 좁게 설치하는 과정을 통해 유도할 수 있다는 점이 확인된다. 식생대의 조도계수 역시 토사저감에 큰 영향을 미치는 것으로 나타났다. 나지의 경우 0.012, Bermuda Grass의 경우 0.41로 조도계수를 설정하고 수치실험을 시행한 결과 조도계수의 증가가 유출 토사량 감소에 큰 영향을 준다는 점이 확인된다. 식생대의 최대 높이가 주는 영향을 살피기 위해서 1 cm에서부터 100 cm까지의 식생대 높이를 적용하고 결과를 분석하였다. 식생대의 특성 및 설치방식을 고정된 조건으로 두고 식생대의 높이에 따른 영향만 살펴보았다. 그 결과 식생대의 최대높이는 유출 토사량에 큰 영향을 주지 않는 것이 나타났다. 이를 통해 유출 토사량 저감 효율을 증가시키고자 할 때 식생의 높이보다는 식생의 종류와 조고 등에 보다 집중하여 식생대를 조성하는 것이 바람직하다는 점을 알 수 있다.

  • PDF

Evaluating stormwater runoff reduction effects of LID according to the RCP climate change scenarios (RCP 기후변화 시나리오와 LID 기법의 적용에 따른 우수 유출저감 효과 분석: 용두빗물펌프장 유역 적용 사례를 중심으로)

  • Park, Kyung Woon;Kim, Min JI;Kim, Ji Eun;Kim, Tae-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.285-285
    • /
    • 2021
  • 급격한 기후변화의 영향으로 강수량은 증가하는 반면 강수일수는 점차 감소하며, 지속적인 도시화로 인해 불투수 면적이 증가하여 침투량은 감소하고 우수 유출량은 증가하고 있다. 이러한 우수 유출량의 증가로 인한 홍수피해에 대한 대책으로 분산형 유출저감 시설인 저영향개발(LID)이 해결방안으로 제시되고 있다. 기존연구에서는 대부분 LID 시설별 우수 유출 저감 효과를 분석하거나, LID 시설의 설치 비율과 강우빈도를 다양하게 적용하여 유출량과 침투량 등을 분석하였다. 그러나 기후변화로 인하여 미래 호우 패턴은 과거와는 다를 것으로 예상되므로 장기적인 측면에서 기후변화 시나리오에 따른 분석을 수행할 필요가 있다. 따라서 본 연구에서는 대표농도경로(RCP)에 따른 기후변화를 반영한 미래 호우사상에 대하여 LID 적용 면적 대비 최고의 효율을 나타낼 수 있는 LID 적용 비율을 산정하였다. 이를 위해 빈번하게 침수피해가 발생하는 동대문구에 위치한 용두빗물펌프장 유역을 선정하였으며, 다양한 LID 기법 중 설치가 용이한 투수성 포장과 옥상녹화, 그리고 도로와 단지에 적용성이 높고 저류기능과 여과기능 등이 있는 식생 체류지를 대상 LID 기법으로 선정하였다. 과거와 미래의 대표 호우사상에 대한 유출량을 SWMM으로 산정한 결과, 강수량은 110.5 mm에서 319.42 mm로 증가하였고, 지표 유출량은 87.346 mm에서 294.63 mm로 증가하였다. 그리고 LID 기법 중 세 가지를 모두 적용한 경우 지표면 유출량이 294.63 mm에서 100.3 mm로 가장 큰 폭으로 감소하였다. 또한 저감 효율이 가장 좋은 설치 면적 비율을 도출하기 위하여 다양한 LID 설치면적 비율에 대한 분석을 하였으며, 유역전체면적대비 적용면적비에 따른 우수유출 저감율을 저감효율로 정의한 결과, LID 설치비율이 60%인 경우가 지표 유출량은 1.37, 저류량은 0.50으로 가장 큰 효율이 나타났다.

  • PDF

Applicability Estimation of LID Techniques (LID 요소기술의 적용성 평가)

  • Yeon, Jong Sang;Kim, Eung Seok;Shin, Hyun Suk;Jang, Young su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.444-444
    • /
    • 2015
  • 현제 도시유역의 산업화와 도시화로 인해 유역 내 불투수면적의 증가는 직접 유출량 증가, 지하수자원 고갈, 침투량 감소, 증발산량의 감소 등의 물 순환 체계의 변화를 가져왔다. 이러한 도시 유역 내 물 순환 체계 변화를 개선하기 위해 여러 국가에서 저영향개발(Low Impact Development, LID)의 개발 및 도입이 진행되고 있다. LID는 분산형 빗물관리 시설로써 유역 내 소규모의 LID 요소기술을 대상유역에 적용하여 강우유출수를 저류, 체류, 방지 및 처리하는 시설을 의미한다. LID는 궁극적 목표로 계획단계에서 개발이전의 수문기능을 유지하기 위해 보전, 영향최소화, 유출이동시간 유지, 추가유출량 감소, 오염발지에 초점을 맞추어 계획된다. 현제 LID의 성능 및 적용성에 대한 다양한 연구가 진해되어지고 있으나, LID 요소기술별 시공 비용, 유지관리 비용, 강우유출수 저감효율, 비점오염원 저감효율, 적용위치 등의 다양한 인자를 복합적으로 고려하여 LID요소기술별 적용성 평가를 수행한 연구는 미미한 실정이다. 따라서 본 연구에서는 LID 요소기술 중 나무화분 여과장치, 옥상녹화, 빗무정원, 투수성포장, 침투트렌치, 빗물통, 식생수로 등의 총 7가지 LID 요소기술을 대상으로 연구를 수행하였다. LID 요소기술의 적용성평가를 수행하기 위해 시공비용, 유지관리비용, 강우유출수 저감효율, 비점오염원 저감효율, 적용위치 등의 촐 5가지 평가인자를 Entropy 방법을 이용하여 평가인자별 가중치를 산정하였다. 이후 다기준의사결정 방법 중 PROMETHEE 방법을 이용하여 LID 요소기술의 우선순위를 산정하였다. 현제 PROMETHEE 방법을 이용하여 LID 요소기술별 우선순위를 산정한 결과 옥상녹화가 첫번째 우선순위로 분석되었으며, 침투트렌치, 나무화분여과장치, 투수성포장, 식생수로, 빗물통, 빗물정원 순으로 분석되었다. 따라서 국내에 LID를 적용할 경우 옥상녹화, 침투트렌치, 나무화분 여과 장치 등의 LID 요소기술의 적용성 및 기대효과가 클 것으로 판단된다. 그러나 국내의 모든 지역을 대상으로 적용하기에는 문제가 있으며, 국내 LID 요소기술 적용 시 기초자료로 사용될 수 있을 것으로 판단된다. 대상지역별 신뢰도 높은 LID 요소기술 적용성 평가를 위해서는 대상유역 내 시공된 LID 요소기술을 계측하여 비점오염원 및 우수유출수 저감효율, 시공 비용, 연간 유지관리 비용을 분석하여 평가를 수행되어 한다고 판단된다.

  • PDF