• Title/Summary/Keyword: 재현도오차

Search Result 123, Processing Time 0.025 seconds

Effectiveness of the Detection of Pulmonary Emphysema using VGGNet with Low-dose Chest Computed Tomography Images (저선량 흉부 CT를 이용한 VGGNet 폐기종 검출 유용성 평가)

  • Kim, Doo-Bin;Park, Young-Joon;Hong, Joo-Wan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.411-417
    • /
    • 2022
  • This study aimed to learn and evaluate the effectiveness of VGGNet in the detection of pulmonary emphysema using low-dose chest computed tomography images. In total, 8000 images with normal findings and 3189 images showing pulmonary emphysema were used. Furthermore, 60%, 24%, and 16% of the normal and emphysema data were randomly assigned to training, validation, and test datasets, respectively, in model learning. VGG16 and VGG19 were used for learning, and the accuracy, loss, confusion matrix, precision, recall, specificity, and F1-score were evaluated. The accuracy and loss for pulmonary emphysema detection of the low-dose chest CT test dataset were 92.35% and 0.21% for VGG16 and 95.88% and 0.09% for VGG19, respectively. The precision, recall, and specificity were 91.60%, 98.36%, and 77.08% for VGG16 and 96.55%, 97.39%, and 92.72% for VGG19, respectively. The F1-scores were 94.86% and 96.97% for VGG16 and VGG19, respectively. Through the above evaluation index, VGG19 is judged to be more useful in detecting pulmonary emphysema. The findings of this study would be useful as basic data for the research on pulmonary emphysema detection models using VGGNet and artificial neural networks.

A Study on the Development of Emotional Content through Natural Language Processing Deep Learning Model Emotion Analysis (자연어 처리 딥러닝 모델 감정분석을 통한 감성 콘텐츠 개발 연구)

  • Hyun-Soo Lee;Min-Ha Kim;Ji-won Seo;Jung-Yi Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.687-692
    • /
    • 2023
  • We analyze the accuracy of emotion analysis of natural language processing deep learning model and propose to use it for emotional content development. After looking at the outline of the GPT-3 model, about 6,000 pieces of dialogue data provided by Aihub were input to 9 emotion categories: 'joy', 'sadness', 'fear', 'anger', 'disgust', and 'surprise'. ', 'interest', 'boredom', and 'pain'. Performance evaluation was conducted using the evaluation indices of accuracy, precision, recall, and F1-score, which are evaluation methods for natural language processing models. As a result of the emotion analysis, the accuracy was over 91%, and in the case of precision, 'fear' and 'pain' showed low values. In the case of reproducibility, a low value was shown in negative emotions, and in the case of 'disgust' in particular, an error appeared due to the lack of data. In the case of previous studies, emotion analysis was mainly used only for polarity analysis divided into positive, negative, and neutral, and there was a limitation in that it was used only in the feedback stage due to its nature. We expand emotion analysis into 9 categories and suggest its use in the development of emotional content considering it from the planning stage. It is expected that more accurate results can be obtained if emotion analysis is performed by additionally collecting more diverse daily conversations through follow-up research.

A Study on the Accuracy of Scan by the Standard Model Deformation Depending on the Hand Scanning Method (핸드스캐닝 작업 방법에 따라 표준 모델 변형이 작업 정밀도에 미치는 정밀스캔에 관한 연구)

  • Shin, Seong-Hun;Jang, Seong-Ho;Song, Joon-Ki;Park, Kwang-Sig;Lee, Hee-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.197-202
    • /
    • 2018
  • This study was conducted to evaluate the distortion and data accuracy that may occur depending on the methods employed by the oral scanner (intra-oral scanner). Deseutap 3D models employing a plaster model used clinically as a scanner to create a standard scan data using the same model, separated by oral scanners in three different ways (AS Group, ZS group, OS group) How to scan each 5 times made the scan data for each group, it shows the 0.121 mm, 0.172 mm AS group, OS group 0.423 mm accuracy in ZS group. The ZS group showed the highest accuracy, with maximum error values of 0.113 mm, 0.169 mm and 0.246 being observed for the ZS, AS and OS group, respectively. The three scanning methods showed a clear differences in accuracy and reproducibility and also appeared to be meaningful in clinical practice.

Estimation of Measurement Uncertainty in Vitamin C Analysis from Vegetable and Fruit Juice (야채음료 중 비타민 C 분석에 있어서의 측정불확도 추정)

  • Kim, Young-Jun;Kim, Hyeon-Wee
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1053-1059
    • /
    • 2003
  • This study aimed to determine the amount of vitamin C from vegetable & fruit juice by high performance liquid chromatograhy (HPLC). Components for estimation of measurement uncertainty associated with the analysis of vitamin C, such as standard weight, purity, molecular weight, dilution of standard solution, calibration curve, recovery, and precision, were importantly applied. The estimation of uncertainty obtained with systematic and random error based on the GUM (Guide to the expression of uncertainty in measurement) and EURACHEM document with mathematical calculation and statistical analysis. The components, evaluated ty either Type A or Type B methods, were combined to produce an overall value of uncertainty known as the combined standard uncertainty. An expanded uncertainty was obtained by multiplying the combined standard uncertainty with a coverage factor (k) calculated from the effective degree of freedom. The content of vitamin C from vegetable and fruit juice was 27.53 mg/100g and the expanded uncertainty by multiplying by the coverage factor (k, 2.06) was 0.63 mg/100g at a 95% confidence level. It was concluded that the main sources were, in order of recovery and precision, weight and purity of the reference material, dilution of the standard solution, and calibration curve. Careful experiments on other higher uncertainties is further needed in addition to better personal proficiency in sample analysis in terms of accuracy and precision.

Electrodeposition of some Alpha-Emitting Nuclides and its Isotope Determination by Alpha Spectrometry (몇가지 알파입자 방출 핵종의 전해석출 및 알파 스펙트럼 측정에 의한 그의 동위원소 정량)

  • Key-Suck Jung;In-Suck Suh
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.279-286
    • /
    • 1983
  • An apparatus was made for the electrodeposition of alpha emitting actinide nuclides, $^{207}Bi$ and $^{210}Po$. The electrodeposition was made on a polished stainless steel plate cathode. The anode was made of platinum wire and to stir the solution. With the ammonium chloride as electrolyte initial pH = 4, chloride concentration = 0.6M and solution volume = 15ml, a current of 1.5 ampere(current density = 0.59A/$cm^2$) was flowed for 100 minutes for the quantitative recovery of electrodeposition and on average recovery of 98.3% was obtained within ${\pm}$0.7% uncertainty. Alpha spectrometry of the electrodeposited sample showed alpha peaks from $^{210}Po, ^{234}U$ and $^{239}Pu$ having energy resolution (FWHM) of 18.3, 21.8 and 36.0 keV respectively. The electrodeposition and alpha spectrometry for a natural uranium sample of domestic origin gave $^{238}U : ^{234}U = 1 : 6.1{\times}10^{-5}$ and for a neutron-irradiated uranium sample did $^{238}U : ^{239}Pu : ^{241}Am = 100 : 0.0263 : 5.20{times}10^{-5}$. The result of $^{238}U$ determination in the irradiated sample by electrodeposition-alpha spectrometry was in accord within ${\pm}1.6%$ of relative error with the results of solid fluorimetry and mass spectrometry. For $^{239}Pu$ the result of electrodeposition-alpha spectrometry was in accord within ${\pm}$4.0% of relative error with the results of anion exchange separation and the thenoyltrifluoroacetone(TTA) extraction both followed by alpha spectrometries.

  • PDF

Accuracy Analysis of Orthometric Heights Based on GNSS Static Surveying (GNSS 정지측량을 통한 표고 산출 정확도 분석)

  • Shin, Gwang-Soo;Han, Joong-Hee;Kwon, Jay Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.5
    • /
    • pp.527-537
    • /
    • 2014
  • In 2013, NGII(National Geographic Information Institute) has developed and provided the KNGeoid13(Korean National Geoid Model 2013) to support the fundamental computation of GNSS-derived orthometric height. In this study, the adjusted ellipsoidal height, the sum of geoidal height and height by the leveling, is applied to calculate the GNSS-derived orthometric height without the local bias, based on GNSS static surveying and KNGeoid13. The mean of errors in GNSS-derived orthometric heights could be verified with the leveling data, which was actually less than 0.5 cm with using the adjusted ellipsoidal heights, but 3 cm by calculating differences between ellipsoidal heights and geoidal heights. By analyze the accuracy of GNSS-derived orthometric height depending on the duration of observation, we could realized 95% of data shows less than 4 cm accuracy, when the GNSS survey conducting for 4 hours spread over two days, but while the case of GNSS survey conducting for 4 hours and 2 hours respectively, resulted in 95% of data less than 5cm level of accuracy. Also, if the ambiguity is fixed, less than 10cm of accuracy could be obtained at 95% of data for only 30 minutes GNSS survey over a day. Following the study, we expected that the height determination by GNSS and geoid models can be used in the public benchmark surveying.

Development of GPS/IMU/SPR Integrated Algorithm and Performance Analysis for Determination of Precise Car Positioning (정밀 차량 위치결정을 위한 GPS/IMU/SPR 통합 알고리즘 개발 및 성능 분석)

  • Han, Joong-Hee;Kang, Beom Yeon;Kwon, Jay Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.2
    • /
    • pp.163-171
    • /
    • 2014
  • Based on the GPS/IMU integration, the car navigation has unstable conditions as well as drastically reduces accuracies in urban region. Nowadays, many cars mounted the camera to record driving states. If the ground coordinates of street furniture are known, the position and attitude of camera can be determined through SPR(Single Photo Resection). Therefore, an estimated position and attitude from SPR can be applied measurements in Kalman filter for updating errors of navigation solutions from GPS/IMU integration. In this study, the GPS/IMU/SPR integration algorithm was developed in loosely coupled modes through extended Kalman filters. Also, in order to analyze performances of GPS/IMU/SPR, simulation tests were conducted in GPS signal reception environments and the GCPs (Ground Control Points) distributions. In fact, the position and attitude gathered from GPS/IMU/SPR integration are more precise than the position and attitude from GPS/IMU integration. When IPs (image points), corresponded to GCPs, were concentrated in the center of image, the position error in the optical axis respectively increased. To understand effects from SPR, we plan to carry additional test on the magnitude of GCP, IP and initial exterior orientation errors.

Robust Planning of Intensity-modulated Proton Therapy for Prostate Cancer (전립선암 치료를 위한 세기조절 양성자 로버스트 치료계획)

  • Park, Su Yeon;Kim, Jong Sik;Park, Ju Young;Park, Won;Ju, Sang Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.25-31
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the dosimetric properties of robust planning strategy for plain intensity-modulated proton therapy (IMPT) taking into account of the uncertainties of effective proton range and set up error as compared to photon intensity-modulated radiation therapy (photon-IMRT) in prostate cancer treatment. Materials and Methods: The photon-IMRT (7 beams, step & shoot), plain-IMPT (2, 4, and 7 portals), and robust- IMPT plans, which was recalculated the plain-IMPT based on the uncertainties of range error (${\pm}5%$) and set up error (0.5 cm), were evaluated for five prostate cancer patients prescribed by 70 Gy/35 fractions. To quantitatively evaluate the dose distributions, several parameters such as maximum dose, minimum dose, mean dose, conformity index (CI), and homogeneity index (HI) for PTV as well as dose-volume index of VxGy for OARs were calculated from dose-volume histograms. Results: Robust-IMPT showed superior dose distributios in the PTV and OARs as compared to plain-IMPT and photon-IMRT. Like plain-IMPT, robust-IMPT were resulted in dose fluctuation around OARs, while better homogeneity and conformity in PTVs and lower mean dose in OARs as compared to photon-IMRT. Conclusion: In consideration with the effective range correction and set up movement using robustness in IMPT plan, the dosimetric uncertainties from plain-IMPT could substantially reduce and suggest more effective solutions than photon-IMRT in prostate cancer treatment.

  • PDF

Turbid water atmospheric correction for GOCI: Modification of MUMM algorithm (GOCI영상의 탁한 해역 대기보정: MUMM 알고리즘 개선)

  • Lee, Boram;Ahn, Jae Hyun;Park, Young-Je;Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.2
    • /
    • pp.173-182
    • /
    • 2013
  • The early Sea-viewing Wide Field-of-view Sensor(SeaWiFS) atmospheric correction algorithm which is the basis of the atmospheric correction algorithm for Geostationary Ocean Color Imager(GOCI) assumes that water-leaving radiances is negligible at near-infrared(NIR) wavelengths. For this reason, all of the satellite measured radiances at the NIR wavelengths are assigned to aerosol radiances. However that assumption would cause underestimation of water-leaving radiances if it were applied to turbid Case-2 waters. To overcome this problem, Management Unit of the North Sea Mathematical Models(MUMM) atmospheric correction algorithm has been developed for turbid waters. This MUMM algorithm introduces new parameter ${\alpha}$, representing the ratio of water-leaving reflectance at the NIR wavelengths. ${\alpha}$ is calculated by statistical method and is assumed to be constant throughout the study area. Using this algorithm, we can obtain comparatively accurate water-leaving radiances in the moderately turbid waters where the NIR water-leaving reflectance is less than approximately 0.01. However, this algorithm still underestimates the water-leaving radiances at the extremely turbid water since the ratio of water-leaving radiance at two NIR wavelengths, ${\alpha}$ is changed with concentration of suspended particles. In this study, we modified the MUMM algorithm to calculate appropriate value for ${\alpha}$ using an iterative technique. As a result, the accuracy of water-leaving reflectance has been significantly improved. Specifically, the results show that the Root Mean Square Error(RMSE) of the modified MUMM algorithm was 0.002 while that of the MUMM algorithm was 0.0048.

An Analysis of DEM and Gravity Effect for Precision Geoid Determination in Korea (우리나라 정밀지오이드 구축을 위한 지형자료 및 중력자료 영향 분석)

  • Lee, Bo-Mi;Lee, Ji-Sun;Kwon, Jay-Hyoun;Lee, Yong-Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.5
    • /
    • pp.519-527
    • /
    • 2008
  • The basic elements in precise geoid determination are the gravity and topographic data with reliable quality and distribution. In this study, the effect of the gravity and topographic data on the precision of the geoid are analyzed through simulations in which the quality and distribution of the data are artificially controlled. It was found that the distribution of the topographic data has more effect on the precision of geoid than the quality of the it. This leads to the conclusion that the SRTM (Shuttle Radar Topography Mission) DTM (Digital Terrain Model) with resolution of 90m is qualified as a topographic data in geoid determination. In the experiments with gravity data, on the other hand, the aliasing effect caused by the low data density caused large errors in geoid. It was found that the more gravity data especially in north-eastern mountainous area is needed for precise geoid determination in Korea.