• Title/Summary/Keyword: 재해사고

Search Result 767, Processing Time 0.021 seconds

Effects of the Questionnaire and Radioactivity Measurement of Fishery from the Fukushima Nuclear Disaster (후쿠시마 원자력 재해 이후 수산물의 방사능 측정 및 설문 조사)

  • Kim, Myung Jun;Kang, Seok Min;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • March 11, 2011 Fukushima nuclear power plant accident has occurred, the last four years, his is the current state of anxiety remains on the consumer. Therefore, 2015 the current progress continues to have continued research for the purpose of resolving the insecurity of fishery in the country. We measured the radiation of the origin of fishery products, by 2015, research was carried out through a number of references to get additional data or studies that influence this to some degree. Create a consumer and one for the seller for the survey to find out the thoughts of both consumers and sellers on fisheries was to create the statistics by direct survey in 2014 year survey meter using PM1405 equipment dynamics of several species of aquatic origin in accordance with the (Taiwan, China, Russia), mackerel, pomfret, hairtail, saury, shrimp, squid measurements of radiation were investigated. The measurement in 2014 was $0.043{\sim}0.073{\mu}Sv/h$. The seller influenced the survey (90%) on fishery products sales, consumer safety, without this fishery (90%), radioactive contamination very high (28%) and the polarization was not as nearly 72%. The study of the stability of the radiation determined by the radiation levels of the aquatic marine products in a comparison the radiation levels result was determined in ICRP below the standard value (1 mSv/y).

Safety Management Factor Analysis of Expert Perceptions Based on 4M Method for Plant Construction Phase (플랜트 시설물 시공단계의 4M기법을 활용한 전문가 인식조사에 의한 안전관리요인 분석)

  • Kim, Kyujin;Choi, Byungsun;Chun, Jaeyoul
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.1
    • /
    • pp.18-27
    • /
    • 2016
  • The purpose of this study is to classify main risk factors on a construction phase of a plant project and analyze importance by the risk factors. Plant Industry is continuing boom and the increase in overseas plant orders in 2014 has showed a performance increase of 61% of the total orders, as the plant industry are risk factors for the construction phase, safety management target recognition and variety of accident prevention and safety factors by importance, etc. a situation that requires the development and introduction of management. So, it is performed that collected disaster conditions data on a construction phase of a plant project, is questioned by plant construction professional and is classified by 4M. Then, it is performed that is questioned by plant construction and safety professional in order to apply AHP method, and is presented from analyzing the risk factors, which are results of the survey, by importance and priority. This study will recognize from identifying the main risk factors in advance and will be utilized as a basic data is to prevent the risk factors.

Technological Development Trends for Underground Safety in Urban Construction (도심지 공사시 지하안전 확보를 위한 기술개발 동향)

  • Baek, Yong;Kim, Woo Seok
    • Tunnel and Underground Space
    • /
    • v.27 no.6
    • /
    • pp.343-350
    • /
    • 2017
  • Amid increasingly saturated ground space, development of underground space has been booming throughout the world and excavation has been underway near the structure above or under the ground level. But the ground subsidence caused by improper or poor construction technologies, underground water leakage, sudden changes of stratum and the problem with earth retaining system component has been emerged as hot social issue. To deal with such problems nationwide, establishment of preventive and proactive disaster management and rapid restoration system has been pushed now. In this study, collection of the data on technology development trend to secure the underground safety was made, taking into account of internal change elements (changing groundwater level, damage to underground utilities, etc) and external change elements (vehicle load, earthquake and ground excavation, etc) during excavation. Amid the growing need of ground behavior analysis, ground subsidence evaluation technology, safe excavation to prevent ground subsidence and reinforcement technology, improvement of rapid restoration technology in preparation for ground subsidence and development of independent capability, this study is intended to introduce the technology development in a bid to prevent the ground subsidence during excavation. It's categorized into prediction/evaluation technology, complex detect technology, waterproof reinforcement technology, rapid restoration technology and excavation technology which, in part, has been in process now.

Development of Closed-loop Control Type FES System for Restoration of Gait in Patients with Foot Drop (족하수 환자의 보행보조를 위한 피드백 제어형 전기자극기 개발)

  • 정호춘;임승관;이상세;진달복;박병림
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.183-190
    • /
    • 1999
  • The purpose of this study was to develop a portable and convenient closed-loop contrel type electrical stimulator for patients with foot drop. This system restores walking movement as well as prevents from atrophy or necrosis of lower limb muscles and increases blood circulation in hemiplegic patients caused by traffic accident, industrial disaster or stoke. This system detects the changes of the ankle joint angle during walking, and then controls the stimulus intensity automatically to maintain the programmed level of the ankle joint angle. Also, this automatic system controls the stimulus intensity which is affected by increased electrode impedance resulting from long time use. The system detects the joint angle by an optical sensor and includes modified PID control which adjusts the stimulus intensity if the joint angle deviates from the preset value. Stimulus parameters are 30~80 volt, 40 Hz, and 0.2 ms. The system was applied to five hemiplegic patients for 42 days. Duration of stimulation was 15 min/day for the first week and then the duration was gradually increased to 30, 60, 90 and 120 min/day. The muscle force was increased up to 29.7%, muscle fatigue was decreased compared with the level before stimulation and the pattern of locomotion was improved. These results suggest that the electrical stimulator with closed-loop control type is more convenient and effective in restoration of locomotion of patients with foot drop than open-loop system.

  • PDF

A Study on the Estimation of Occupational Safety and Health Expense Rate by Safety Environment Change in Construction Industry (건설산업의 안전 환경 변화에 따른 산업안전보건 관리비 적정요율 산정에 관한 연구)

  • Oh, Se-Wook;Kim, Young-Suk;Choi, Seung-Ho;Choi, Jin-Woo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.4
    • /
    • pp.97-107
    • /
    • 2013
  • Occupational safety and health management expense in construction industry means the monetary amount that the purchaser appropriates to prevent various disaster from happening during the construction period by setting aside a certain amount from subcontract based on the construction type and scale. The current appropriation standard of the Ministry of Employment and Labor has been enforced since its stipulation in 1988 although various policy changes for the safety in construction industry, e.g. the development of occupational safety management techniques in construction industry, changes in construction field site environment, cost depreciation, etc., are happening in Korea and overseas. Therefore, it is required at this point to examine whether the current occupational safety and health management expense appropriation is proper or not on the basis of time trend and the changes in the construction industry environment. Accordingly, this study aims at investigating the appropriation of occupational safety and health management expense for construction industry by the construction type and target expense in response to current construction industry environment and proposing the proper appropriation. The above research result proposes the calibration of the appropriation as specified and stipulated by the Ministry of Employment and Labor by the construction type and target expense, which is necessary to reflect the actual condition of the current construction industry environment.

Policy Study on Appropriateness of Safety Check Costs in Construction Projects - Focusing on Industrial Safety and Health Act - (건설공사 안전점검대가의 적정성에 대한 정책적 고찰 - 산업안전보건법을 중심으로 -)

  • Kim, Byeong-Cheol;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.747-757
    • /
    • 2017
  • Of safety check regulation, 'Construction Technology Promotion Act' and 'Special Act on the Safety Control of Public Structures' contain provisions about the content of safety in construction works and the items of safety checks in the maintenance aspect and thus contribute to accident prevention in the construction industry. Of the regulations responsible for the practical safety of workers, the safety check regulation of Ministry of Employment and Labor demand for safety check from the start of construction based on an agreement with a concerned agency to the completion of construction solely based on 'Guidance Standards for the Specialized Disaster Prevention Instruction in Article 32 of Occupational Safety and Health Act' and 'Appropriation and Usage Standards of Safety and Health Management Costs in the Construction Industry'. There is, however, a huge gap, as well, in them according to client agencies. In small construction sites ordered by a private organization, checks are done formally with no detailed regulations. As a result, the costs of checks continue to drop with only the contract kept intact. This study examined the forms of safety checks practically done in the Jeju region, distinguished and compared them by the construction costs, calculated proper costs based on each construction act, and further proposed improvement measures for the detailed regulations.

Efficient Design of a Disaster Broadcasting System using LTE Modem (이동 LTE모뎀을 활용한 재난방송시스템 설계)

  • Moon, Chaeyoung;Kim, Semin;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.292-294
    • /
    • 2018
  • Recently, damage caused by natural disasters such as fire, earthquake, heavy rains and heavy snow is increasing. In addition, traffic accidents due to freezing, fog and fire in tunnels and bridges are frequently occurring. In such a disaster situation, it is very important to take prompt action by the person in charge of managing the facility and area.To this end, a disaster broadcasting system is used, but in the existing system, the broadcasting room and the speaker are connected by a wired connection. Also, the person in charge has to be in the broadcasting room to broadcast, which has a problem of delaying the time. In this paper, we design a disaster broadcasting system using LTE modem. The designed system enables a broadcasting person to make a call to a broadcasting system from anywhere using a cellular phone and a public telephone. Broadcasting via telephone is possible only with the telephone number pre-registered in the system and can be registered / deleted by the administrator. The registered telephone number, incoming voice file, and announcement voice for automatic broadcasting are stored in the system internal SD memory for convenient management. This disaster broadcasting system is expected to contribute to quick and convenient disaster broadcasting.

  • PDF

A Study on the Quantitative Risk Assessment of Bridge Construction Projects (교량 공사 프로젝트의 정량적 리스크 평가에 관한 연구)

  • Ahn, Sung-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.1
    • /
    • pp.83-91
    • /
    • 2020
  • The recent bridge construction projects is demanded more sophisticated risk management measures and loss forecasts to brace for risk losses from an increase in the trend of bridge construction. This study aims to analyze the risk factors that caused the loss of material in actual bridge construction and to develop a quantified predictive loss model, based on the past record of insurance payment by major domestic insurance companies for bridge construction projects. For the development of quantitative bridge construction loss model, the dependent variable was selected as the loss ratio, i.e., the ratio of insurance payout divided by the total project cost, while the independent variable adopted 1) Technical factors: superstructure type, foundation type, construction method, and bridge length 2) Natural hazards: typhoon and flood 3) Project information: construction period and total project cost. Among the selected independent variables, superstructure type, construction method, and project period were shown to affect the ratio of bridge construction losses. The results of this study can provide government agencies, bridge construction design and construction and insurance companies with the quantitative damage prediction and risk assessment services, using risk indicators and loss prediction functions derived from the findings of this study and can be used as a guideline for future basic bridge risk assessment development research.

A study on the explosion proof by the electric discharge on voltage application type (전압인가식 제전기의 방폭화에 관한 연구)

  • Lee Chun Ha;Kim Jum Ho;Park Min Young
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.62-69
    • /
    • 2004
  • It is necessary to eliminate the electric static for the prevention of disasters by electric static discharge, the improvement of production efficiency, the protection of a sensitive electronic devices in the variable manufacturing processes. Then it is handled for elimination of electric static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the ideal condition of electric static elimination efficiency by changing of the length of voltage input type eliminator's bar, the length of copper pipe and the gap of electrode and the existence of explosion by inflammable gas with that conditions. As the result, the electric static elimination efficiency has the most ideal value at the 8-11(mm) gap of the earth electrode and needle type electrode each elimination bar and there is not explode at the explosive experiment of inflammable gas with the ideal elimination bar. We can consider that there are some data which are needed for elimination efficiency and it will be able to protect the occurrence of explosion accident inflammable nas in the industrial fields.

  • PDF

Research Trends of SCADA Digital Forensics and Future Research Proposal (SCADA 디지털포렌식 동향과 향후 연구 제안)

  • Shin, Jiho;Seo, Jungtaek
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.6
    • /
    • pp.1351-1364
    • /
    • 2019
  • When SCADA is exposed to cyber threats and attacks, serious disasters can occur throughout society. This is because various security threats have not been considered when building SCADA. The bigger problem is that it is difficult to patch vulnerabilities quickly because of its availability. Digital forensics procedures and techniques need to be used to analyze and investigate vulnerabilities in SCADA systems in order to respond quickly against cyber threats and to prevent incidents. This paper addresses SCADA forensics taxonomy and research trends for effective digital forensics investigation on SCADA system. As a result, we have not been able to find any research that goes far beyond traditional digital forensics on procedures and methodologies. But it is meaningful to develop an approach methodology using the characteristics of the SCADA system, or an exclusive tool for SCADA. Analysis techniques mainly focused on PLC and SCADA network protocol. It is because the cyber threats and attacks targeting SCADA are mostly related to PLC or network protocol. Such research seems to continue in the future. Unfortunately, there is lack of discussion about the 'Evidence Capability' such as the preservation or integrity of the evidence extracting from SCADA system in the past researches.