• Title/Summary/Keyword: 재사용 간격

Search Result 277, Processing Time 0.03 seconds

Model Test Study on the Reinforcing Effect of Inclined System Bolting (경사볼트의 보강효과에 대한 모형시험 연구)

  • Lee, Jea-Dug;Kim, Byoung-Il;Piao, Ming-Shan;Yoo, Wan-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5C
    • /
    • pp.231-238
    • /
    • 2012
  • The rockbolt functions as a main support, which restricts enlargement of the plasticity area and increases stability in the original ground around tunnels, and prevents a second deformation of an excavated surface by supplementing vulnerability arising from opening of the excavated surface. System bolting is generally applied if ground conditions are bad. System bolting is generally installed perpendicular to the excavation direction in every span. If a place is narrow, or it is difficult to insert bolts due to construction conditions, it may be connected and used with short bolts, or installed obliquely. In this study, laboratory model tests were performed to analyze the effect of the ground being reinforced by inclined bolts, based on a bending theory that assumes that the reinforced ground is a simple beam. In all test cases, deflections and vertical earth pressures induced by overburden soil pressure were measured. Total of 99 model tests were carried out, by changing the installation angle of bolts, lateral and longitudinal distance of bolts, and soil height. The model test results indicated that when the installation angle of bolts was less than $75^{\circ}$, deflections of model beams tended to increase rapidly. Also, the relaxed load that was calculated by earth pressure was rapidly increased when the installation angle of bolts was less than $75^{\circ}$. However, the optimum installation angle of inclined bolts was judged to be in the range of $90^{\circ}{\sim}75^{\circ}$. Also, as might be expected, the reinforcement effect of bolts was increased when the longitudinal and lateral distance of bolts was decreased.

A Study on the Flexural Behavior of Plate Girder Bridge Decks Using a Macro-Element (매크로 요소를 사용한 판형교 바닥판의 휨거동 해석)

  • 최진유;양기재;박남회;강영종
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.1
    • /
    • pp.13-24
    • /
    • 2000
  • Current specification prescribes that upper and lower reinforcement mat is required in the same amount to resist negative and positive moment in bridge decks. But the negative moment is much smaller than positive moment because the actual behavior of decks consists of local deflection of slab and global deflection of girder. From this study, the analysis method based on harmonic analysis and slope-deflection method was developed and verified by finite element method. The negative moment, obtained from this method, were smaller than those computed based on the KHBDC specifications as much as 40∼50% in the middle of bridge. The amount of reduction of the design negative moment was shown herein to be dependent on variable parameters as shape factor(S/L) of slab, relative stiffness ratio of girder and deck slab, and so on. This investigations indicate that the upper reinforcement mat to resist negative moment can be removed. But further experimental study is required to consider durability and serviceability. From this new design concept, the construction expense can be reduced and the problem of decreasing durability resulting from corrosion of upper reinforcement steel settled.

  • PDF

A study on the discriminant analysis of node deployment based on cable type Wi-Fi in indoor (케이블형 Wi-Fi 기반 실내 공간의 노드 배치 판별 분석에 관한 연구)

  • Zin, Hyeon-Cheol;Kim, Won-Yeol;Kim, Jong-Chan;Kim, Yoon-Sik;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.836-841
    • /
    • 2016
  • An indoor positioning system using Wi-Fi is essential to produce a radio map that combines the indoor space of two or more dimensions, the information of node positions, and etc. in processing for constructing the radio map, the measurement of the received signal strength indicator(RSSI) and the confirmation of node placement information counsume substantial time. Especially, when the installed wireless environment is changed or a new space is created, easy installation of the node and fast indoor radio mapping are needed to provide indoor location-based services. In this paper, to reduce the time consumption, we propose an algorithm to distinguish the straight and curve lines of a corridor section by RSSI visualization and Sobel filter-based edge detection that enable accurate node deployment and space analysis using cable-type Wi-Fi node installed at a 3 m interval. Because the cable type Wi-Fi is connected by a same power line, it has an advantage that the installation order of nodes at regular intervals could be confirmed accurately. To be able to analyze specific sections in space based on this advantage, the distribution of the signal was confirmed and analyzed by Sobel filter based edge detection and total RSSI distribution(TRD) computation through a visualization process based on the measured RSSI. As a result to compare the raw data with the performance of the proposed algorithm, the signal intensity of proposed algorithm is improved by 13.73 % in the curve section. Besides, the characteristics of the straight and the curve line were enhanced as the signal intensity of the straight line decreased by an average of 34.16 %.

Effect of Abdominal Respiration on the Electrical Axis of ECG in Young Adults (복식호흡이 젊은 성인의 심전도축에 미치는 영향)

  • Youn, Ryea-Min;Kim, Young-Sik;Yoon, Im-Sil;Jung, Han-Na;Nam, Jeong-Su;Yoon, Joong-Soo;Lee, Won-Joon;Choi, Hyun-Ju
    • Journal of Life Science
    • /
    • v.20 no.5
    • /
    • pp.723-728
    • /
    • 2010
  • The effect of abdominal respiration on electrocardiogram readings was examined using a 12-lead ECG in healthy young adults. Ten males and ten females without any cardiac and/or pulmonary problems participated in this study. ECG readings during periods of abdominal respiration and thoracic respiration were compared using a paired t-test. Results showed that the PR interval was longer in males compared to females during the period of abdominal respiration (p<0.05). There were no differences in amplitudes of the P, R, T waves, QTc, and degree of P axis between abdominal respiration and thoracic respiration in both male and female subjects. However, degrees of QRS axis in male subjects (p<0.05) and T axis (p<0.05) in female subjects were increased during the abdominal respiration. Therefore, abdominal respiration may cause positive electrical axis changes in the depolarization and relaxing re-polarization of the ventricles.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

Image Evaluation of Projection Method in Chest Radiography (흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.217-223
    • /
    • 2022
  • In this study, images taken using a grid and images taken using Air Gap Technique were evaluated in X-ray chest radiography. Subjective Evaluation The ROC (Receiver Operating Characteristic) evaluation was evaluated by 5 radiologists who had worked for more than 10 years in the radiology department of a university hospital. Objective evaluation SNR (Signal to noise ratio) was evaluated. As a result of the analysis, the Cronbach Alpha value was 0.714, which was significantly higher. In the Air Gap Technique, the distance between the phantom and the subject was set at 20 cm, and the image was taken with a tube voltage of 100 kVp, a tube current and a recording time of 8 mAs. In the ROC (Receiver Operating Characteristic) evaluation, the highest score was obtained with 18 score and an objective evaluation SNR (signal to noise ratio) of 6,149 scored. Also, in the imaging method using a grid, when the distance between the phantom and the constant receptor is 15 cm apart, and the tube voltage is 110 kVp, the tube current and the recording time are taken at 8 mAs, the ROC evaluation score is 19 and the objective evaluation SNR (Signal to noise ratio) is the highest with 6.622 scored. Therefore, if the Air Gap Technique imaging method is used, which overcomes the shortcomings such as delay in reading, increase in patient's exposure dose, and shortening of mechanical lifespan, as well as re-radiography due to the cut-off phenomenon of the grid that appears using the grid, the It is thought that it will be very helpful for chest imaging, including the case of using a portable X-ray imaging device.

A Study on Image Acquisition of Gamma Camera using Simulation LUT and MLPE (시뮬레이션 순람표와 최대우도함수를 이용한 감마카메라의 영상 획득 연구)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.409-414
    • /
    • 2021
  • In order to acquire an image from a gamma camera, linearity correction must be performed. To this end, digital coordinates are acquired by using a linearity map to accurately specify the location where the scintillator and gamma rays interact. In this study, a method for acquiring undistorted images and digital coordinates was developed using a lookup table and maximum likelihood position estimation without using a linearity map. The proposed method was verified by configuring a small gamma camera through DETECT2000 simulation. A gamma camera was constructed using a GAGG scintillator and a SiPM optical sensor, and a gamma-ray interaction was generated at the center of the scintillator, and a lookup table was prepared using the ratio of the signals obtained from the SiPM. Through the prepared lookup table and the maximum likelihood position estimation, the position of the signal obtained by the gamma-ray interaction was acquired as digital coordinates to compose an image. As a result, the linearity was maintained compared to the generally acquired image, the accuracy of the location where the gamma-ray interaction was generated was excellent, and the distance between the locations was uniform. Since the lookup table obtained through simulation is created using the ratio of the signal, it can be directly used in the experiment, and the position of the signal can be conveniently obtained with digital coordinates with corrected linearity without creating a linearity map.

Effect of Pyruvate and Aspartate Enriched University of Wisconsin Solution on Myocardial Protection (피루브산염과 아스파라진산염을 첨가한 위스콘신대학 용액의 심근보호 효과)

  • 이정렬;김준석;한재진;강문철
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.11-19
    • /
    • 2002
  • Background: Ischemia-reperfusion myocardial injury is an important factor to determine the early and the late mortality of transplanted patients. Recently, modulation of the cytosolic NADH/NAD+ ratio by Pyruvate and aspartate was tested to Protect the heart from ischemia-reperfusion injury. Material and Method: We added pyruvate and aspartate to the University of Wisconsin solution, and evaluated their effect on myocardial protection. We used 16 piglet(age 1 to 3 days) hearts. Eight hearts were arrested with and stored in the University of Wisconsin solution(UW solution) for 24 hours(control group), and the other eight hearts were arrested with and stored in the modified UW solution added pyruvate(3mmol/L) and aspartate(2 mmol/L)(test group). All hearts underwent modified reperfusion with blood cardioplegic solution followed by conversion to a left-sided working model with perfusion from a support pig. And then, we measured stroke work index(SWI), high-energy phosphate stores, and myocardial water content of the hearts. SWI was calculated at left ventricular end-diastolic pressures of 3, 6, 9, and 12 mmHg after 60 and 120 minutes reperfusion, respectively, Result: At 60 minutes and 120 minutes after reperfusion, SWI was higher in the test group than in the control group significantly. The levels of AMP, ADP, ATP of the test group were also higher. But, the creatine phosphate level and myocardial water content were similar in the two groups. Conclusion: From these results, we could Prove that pyruvate and aspartate enhance cardiac contractility and high-energy phosphate stores after ischemia.

Stability of the Innovative Prestressed wale System Applied in Urban Excavation (도심지 굴착에 적용된 IPS 띠장의 안정성)

  • Kim, Nak-Kyung;Park, Jong-Sik;Jang, Ho-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.225-235
    • /
    • 2005
  • The stability of innovative prestressed wale system applied in urban excavation was investigated. The IPS is a wale system prestressed by tension of steel wires. The IPS consists of steel wires, H-beam support and wale. The IPS provides a high flexural stiffness to resist the bending moment caused by earth pressures. And the IPS transmits earth pressures due to excavation to corner struts. The IPS provides a larger spacing of support, economical benefit, construction easiness, good performance and safety control. This paper explains basic concept and mechanism of the IPS and presents the measured performances of the IPS applied in urban excavation. In order to investigate applicability and stability of the IPS in urban excavation, observations and measurements in site were performed. The IPS applied in urban excavation was performed successfully. The results of the field instrumentation were presented. The measured performances of the IPS were investigated. And behavior of the wall and corner struts was investigated.

Settlement Restraint of Soft Ground by Low Slump Mortar Injection (저유동설 몰탈주입에 의한 연약지반의 침하억제 효과)

  • 천병식;여유현;정영교
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.53-67
    • /
    • 2001
  • In this study the pilot test of CGS as injection method by low slump mortar was performed and the results were analyzed in order to find out the application of this method and effect of settlement restraint. The site far pilot test is adjacent to apartments supported by pile foundations. Sand drain method was performed previously as countermeasures against settlement, but settlement occur continuously because this ground is very soft. Site investigations such as SPT, DCPT and vane shear test were performed to determine the characteristics of ground improvement. Field measurements and FDM analysis were performed on purpose to find out the displacement of ground during injection works. From the results of this study, CGS method can be optimized by the control of diagram, space, depth, injection material, and injection pressure. CGS improved soft ground compositely by the bearing effect of CGS columns and reinforcement of adjacent ground. Considering that increase of N value is about 2.1, CGS can be considered as an effective method to increase the bearing capacity as well as to stop the settlement of soft ground. It is also expected to be economic and effective in improvement of ground when it is used in applicable sites.

  • PDF