• Title/Summary/Keyword: 재사용 간격

Search Result 277, Processing Time 0.032 seconds

Numerical Analysis of Coupled Thermo-Hydro-Mechanical (THM) Behavior at Korean Reference Disposal System (KRS) Using TOUGH2-MP/FLAC3D Simulator (TOUGH2-MP/FLAC3D를 이용한 한국형 기준 처분시스템에서의 열-수리-역학적 복합거동 특성 평가)

  • Lee, Changsoo;Cho, Won-Jin;Lee, Jaewon;Kim, Geon Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.183-202
    • /
    • 2019
  • For design and performance assessment of a high-level radioactive waste (HLW) disposal system, it is necessary to understand the characteristics of coupled thermo-hydro-mechanical (THM) behavior. However, in previous studies for the Korean Reference HLW Disposal System (KRS), thermal analysis was performed to determine the spacing of disposal tunnels and interval of disposition holes without consideration of the coupled THM behavior. Therefore, in this study, TOUGH2-MP/FLAC3D is used to conduct THM modeling for performance assessment of the Korean Reference HLW Disposal System (KRS). The peak temperature remains below the temperature limit of $100^{\circ}C$ for the whole period. A rapid rise of temperature caused by decay heat occurs in the early years, and then temperature begins to decrease as decay heat from the waste decreases. The peak temperature at the bentonite buffer is around $96.2^{\circ}C$ after about 3 years, and peak temperature at the rockmass is $68.2^{\circ}C$ after about 17 years. Saturation of the bentonite block near the canister decreases in the early stage, because water evaporation occurs owing to temperature increase. Then, saturation of the bentonite buffer and backfill increases because of water intake from the rockmass, and bentonite buffer and backfill are fully saturated after about 266 years. The stress is calculated to investigate the effect of thermal stress and swelling pressure on the mechanical behavior of the rockmass. The calculated stress is compared to a spalling criterion and the Mohr-Coulumb criterion for investigation of potential failure. The stress at the rockmass remains below the spalling strength and Mohr-Coulumb criterion for the whole period. The methodology of using the TOUGH2-MP/FLAC3D simulator can be applied to predict the long-term behavior of the KRS under various conditions; these methods will be useful for the design and performance assessment of alternative concepts such as multi-layer and multi-canister concepts for geological spent fuel repositories.

A Case Study of Blasting with Electronic Detonator (전자뇌관을 활용한 발파 시공 사례)

  • Hwang, Nam-Sun;Lee, Dong-Hoon;Lee, Seung-Jae
    • Explosives and Blasting
    • /
    • v.34 no.4
    • /
    • pp.40-45
    • /
    • 2016
  • Sites, where explosives are used, are constantly under constraint of vibration and noise levels. If a sensitive area is located nearby the sites, mechanical excavation has been preferred rather than blasting. Recently, however, blasting using electronic detonators is applicable in the areas, where previously should be excavated by mechanical methods. $HiTRONIC^{TM}$ is a fourth-generation detonator that utilizes Hanwha Corporation's advanced electronic technology. The detonator contains IC-Chip, which allows delay times between 0~15,000ms with 1ms interval. Furthermore, the product can provide high accuracy(0.01%) for accurate-blasting. Electronic detonator is widely used in highway and railway construction sites, large limestone quarries, and other works. In this paper, several sites, in which HiTRONIC was used, are introduced in order to enhance understanding of electronic detonator.

The Evaluation of the Axial Strength of Composite Column with HSA800 Grade Steel (HSA800 강재를 적용한 합성기둥의 축방향 내력 평가)

  • Lee, Myung Jae;Kim, Cheol Hwan;Kim, Hee Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.473-483
    • /
    • 2014
  • According to the Korean Building Code (KBC), the validity of the application of 800MPa grade steel(HSA800) to composite column should be verified by experimental or analytical method. Thus, stub column tests for encased and filled composite members with HSA800 steel were conducted, and axial strength and the validity of design compressive strength equations in KBC were evaluated. The test results show that the equation of the compressive strength of encased composite column member in KBC should be modified in order to use HSA800 steel without any reduction of specified minimum yield strength. For this purpose, it is suggested that the interval of hoop should be narrowed and the effective concrete area should be used. The equation of the compressive strength of filled composite column member in KBC is applicable to filled composite column with HSA800 steel without any modification.

New calibration apparatus for a precise barometer (초정밀 기압계 교정을 위한 새로운 압력계 교정장치 개발)

  • 우삼용;이용재;최인묵;김부식;최종운
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.3
    • /
    • pp.157-161
    • /
    • 2003
  • Nowadays there are increasing demands for more accurate measurement of atmospheric pressure according to the development of environmental industries. One of the most important pressure gauges for satisfying these demands is a quartz resonance barometer. In order to calibrate such an accurate barometer, laser/ultrasonic mercury manometers have been used. However, complexity and cost of mercury manometers made it out of use gradually. As a substitute, a gas-operated pressure balance is used for calibration of precise barometers. In such a case, commercially available pressure balances cannot be entirely suitable because consequent exposure of the piston, cylinder and masses to the atmosphere causes the problem of contamination. In this paper a device for changing the masses in situ without breaking the vacuum is described. This device made it possible to add or remove weights in the absolute mode, thereby greatly reducing the time between observations. At the same time, we investigated the characteristics of a commercial precise barometer using this new apparatus.

Effect of Recombinant CagL Immunization on the Gastric Diseases Induced by Helicobacter pylori in Mongolian gerbils (CagL 재조합 단백질 접종후에 Mongolian gerbil에서 나타나는 Helicobacter pylori 감염에 대한 반응)

  • Bak, Eun-Jung;Jang, Sung-Il;Choi, Yun-Hui;Kim, Jin-Moon;Kim, Ae-Ryun;Kim, Ji-Hye;Woo, Gye-Hyeong;Yoo, Yun-Jung;Lee, Sung-Haeng;Cha, Jeong-Heon
    • Korean Journal of Microbiology
    • /
    • v.48 no.2
    • /
    • pp.109-115
    • /
    • 2012
  • Helicobacter pylori is an important factor of chronic gastritis, digestive ulcer, and stomach cancer. CagL, a virulence factor of H. pylori, is well-known as a pilus protein which acts as adhesion to host cell and a component of Type 4 secretion system. In this study, we evaluated the protective response of recombinant CagL protein (rCagL) using Mongolian gerbil animal model for H. pylori infection. The cagL gene was cloned from 26695 H. pylori followed by over-expression and purification of the protein in E. coli. Mongolian gerbils were immunized with rCagL protein mixed with aluminum adjuvant via intramuscular injections once a week during 4 weeks. At a week after the last immunization, the Mongolian gerbils were administrated with H. pylori 7.13 strain into the stomach and sacrificed to measure antibody titer on rCagL by ELISA and bacterial colonization in the stomach, and to examine the histopathological changes and cytokine expression at 6 week after challenge. Antibody titers on recombinant protein were significantly increased from a week after the first immunization. There was no significant change of the number of bacterial colony between control group and immunized group. The relative stomach weight was significantly decreased in immunized group, but the significant change of histopathological assessment was not observed in the stomach. Cytokine expression such as IL-$1{\beta}$ and KC also was not significantly different between control and immunized groups. These results indicate that rCagL could effectively induce the formation of the specific IgG antibodies. However, bacterial colonization and histopathological lesions could not be inhibited by the immunization in the stomach, indicating not enough protection against H. pylori infection. We consider that along with CagL other adequate antigens could be needed stimulating immune response and inducing protective effects against gastric disease, and also a better adjuvant could be considered.

LONG-TERM EVALUATING OF THE REMINERALIZATION OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: A MICRO-CT STUDY (미세 전산화 단층 촬영을 이용한 글라스 아이오노머 수복물의 인접면우식 재광화 효과에 관한 장기간 연구)

  • Lee, Hyeok-Sang;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.498-503
    • /
    • 2006
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements (highly-filled glass ionomer cement, compomer, resin-modified glass ionomer cement) and a resin composite(control). The long-term changes in remineralization caused by each material were evaluated by microtomography. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 for 30 days with constant circulation Tomographic images were obtained with a micro CT scanner at 90, 180, and 270 days, and density-measuring software was used to calculate the micro-density of artificial caries lesions in the specimens. The mean density changes were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using one-way ANOVA and the post-HOC Tukey multiple comparison test at p<0.05. While the density of artificial caries lesions increased for all treatments, the increases for the three glass ionomer groups were significantly higher than that for the resin group in each three month period. As time went on, the amount of density increase of the glass ionomer groups decreased, and significant differences were found between the remineralization effects of the glass ionomer groups.

  • PDF

The Evaluation for Pullout Performance of Steel Strip Reinforcements with Deformed-Bars as Transverse Members (지지부재로 이형철근을 설치하는 띠형 강보강재의 인발성능 평가)

  • Jung, Sung-Gyu;Kim, Juhyong;Cho, Samdeok;Lee, Kwangwu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.4
    • /
    • pp.77-86
    • /
    • 2013
  • Laboratory pullout tests were conducted to evaluate pullout performance of steel strip reinforcements with deformed steel bars as transverse members. The steel strip reinforcement has an installation hole to assemble a deformed steel bar. Jumunjin standard sand is used to form a relative density of ground model to 80%. Frictional resistance of steel strip reinforcement without transverse member increases sharply at the initial displacement and quickly decreases with displacement. Maximum frictional resistance increases linearly as normal pressure increasing, and soil-reinforcement interaction friction angle(${\rho}_{peak}$) of a steel strip reinforcement is estimated to $14.64^{\circ}$. Passive resistance increases with displacement and converge into maximum passive resistance in most cases. Maximum passive resistance increases linearly as normal pressure increasing irrespective of shape of the steel reinforcement. Pullout force of steel strip reinforcements with installation holes or transverse members largely increases about 4 to 7 times compared to frictional resistance force of steel strip reinforcements when embedment length($L_e$) of steel strip reinforcements is 500 mm. In the case of using 2 transverse members, interference effect is observed due to the spacing of 2 transverse members and location of assembly holes and transverse members.

Modified Cubic Convolution Scaler for Multiformat Conversion in a Transcoder (다양한 포맷변환을 지원하는 Transcoder의 개선된 Cubic Convolution Scaler)

  • Yoo, Young-Joe;Seo, Ju-Heon;Han, Jong-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.9C
    • /
    • pp.867-880
    • /
    • 2007
  • We derive a modified version of cubic convolution interpolation for the enlargement or reduction of digital images by arbitrary scaling factors. The proposed scaling scheme is used to resize various format pictures in the transcoding system, which transforms the bitstream compressed at a bit rate, such as the HD bitstream, into another bit rate stream. In many applications such as the transcoder, the resolution conversion is very important for changing the image size while the scaled image maintains high quality. We focus on the modification of the scaler kernel according to the relation between formats of the original and the resized image. In the modification, various formats defined in MPEG standards are considered. We show experimental results that demonstrate the effectiveness of the proposed interpolation method.

유도 결합 플라즈마원의 외부 냉각에 관한 수치 모델링

  • Ju, Jeong-Hun;Jo, Jeong-Hui;Park, Sang-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.218-218
    • /
    • 2016
  • 실린더 형태의 유전체 관에 나선형으로 도전체 안테나를 설치하는 타입의 유도 결합 플라즈마원은 간단한 구조로 화학 조성 분석용부터 나노 분말 제조, 반도체용 식각/증착, 표면 처리, 자동차 및 일반 산업 부품용 증착 보조원등으로 널리 사용되고 있다. 고밀도 라디칼/이온의 공급을 위해서 투입 전력을 증가시키는 경우 높은 전력 밀도로 인해서 유전체 관에 인가되는 열응력이 대기압 및 관 고정용 구조물에 의한 구조 응력에 더해져서 파손에 이르는 경우가 발생될 수 있다. 실제 실린더 길이 전체를 안테나 코일로 감는 경우에도 플라즈마 발생 밀도가 높은 지역은 중심 일부 영역에 국한 되는 공정 영역도 있어서 이에 대한 분석이 필요하다. CFD-ACE+를 이용하여 플라즈마의 생성, 냉각수의 열전도, 외부 공냉식 팬의 역할등에 대해서 수치 모델을 작성하여 검토하였다. 나선형 냉각코일의 경우 냉각수량을 일정값 이상으로 증가시키는 경우 유속이 지나치게 빨라져서 열원이 있는 내경쪽 표면에서 열전도가 유속에 비례해서 증가하지 못하는 단점이 발생할 수 있으며 냉각팬의 경우 일반적으로 장치 내부에 대해서만 모델링을 하는 데 실제로 전체 시스템의 주변에서 공기의 흐름을 넓게 해석해야 실제 냉각 효과를 파악할 수 있다. 심한 경우 냉각용 공기 흡입구와 토출구의 간격이 좁아서 열원에 의해서 가열된 공기의 상당량이 다시 냉각용 공기 흡입구로 재순환 되는 경우도 발생하기 쉽다.

  • PDF

InGaN/GaN LED 구조의 Bowing 및 광전특성 개선 연구

  • Lee, Gwan-Jae;Kim, Jin-Su;Lee, Cheol-Ro;Lee, Jin-Hong;Im, Jae-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.192.2-192.2
    • /
    • 2015
  • 본 논문에서는 사파이어 기판 표면에 레이저 처리를 통해 격자 구조(레이저 격자 구조)를 제작하고 InGaN/GaN 발광다이오드(Light-Emitting Diodes, LED) 박막을 성장 한 시료에서 Bowing 특성 변화를 논의한다. 그리고 Bowing 정도에 따른 InGaN/GaN LED의 광학 및 전기적 특성을 Photoluminescence (PL)와 Electroluminescence (EL) Mapping 법을 이용하여 상호 비교 분석하였다. 2-인치 사파이어 기판 상에 레이저 격자 구조의 간격은 1 mm (GS1-LED), 2 mm (GS2-LED), 3 mm (GS3-LED) 로 제작하였으며, 격자 구조가 없는 LED를 기준 시료(C-LED)로 사용하였다. GS1-LED, GS2-LED, GS3-LED의 Bowing 정도는 C-LED 대비 각각 8%, 7.6%, 6.4% 감소하였다. PL Mapping 결과, GS-LED의 발광 파장의 분포 균일도가 C-LED 보다 개선되는 것을 확인하였고, 파장이 C-LED 대비 단파장으로 이동하였다. 또한, GS-LED시료의 PL 강도는 C-LED보다 증가하였고, 특히 GS2-LED의 PL 강도는 C-LED 대비 6.9% 증가 하였다. EL mapping 결과, GS-LED 발광 파장의 분포 균일도는 PL 결과와 유사하게 측정되었으며, 2인치 기판 전체 면적에 대한 GS-LED의 주요 동작전압 및 출력 전력 수율이 C-LED대비 현저히 개선되었다. 사파이어 기판 표면에 제작한 레이저 격자 구조에 따른 InGaN/GaN LED의 광학적, 전기적 특성을 Bowing의 개선과 응력 완화 현상으로 논의 할 예정이다.

  • PDF