• Title/Summary/Keyword: 재사용 가능

Search Result 2,783, Processing Time 0.036 seconds

Proposal of Reuse Method of Sorting Soil Produced in Treatment Process of Construction Waste (건설폐기물의 처리공정에서 생산된 선별토사의 활용 방안 제시)

  • Na, Chul-Sung;Kang, Han-Su;Park, Jung-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.111-116
    • /
    • 2009
  • In order to verify relevance propriety as material for improving and replacing agricultural land of soil(the rest is sorting soil) produced in treatment process of construction waste, this study executed physical, mechanics and soil analysis test with mixing sorting soil and farm land, crops rearing comparison test with replacing lower layer soil.

  • PDF

전해환원 금속전환체 잔류염 제거 기초 실험

  • Park, Byeong-Heung;Jeong, Myeong-Su;Jo, Su-Haeng;Heo, Jin-Mok
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.296-296
    • /
    • 2009
  • 산화물 사용후핵연료를 대상으로 하는 파이로 공정은 고온 용융염 매질에서 산화물을 금속으로 전환시키는 전해환원 공정으로부터 시작된다. 이후, 전해정련 공정이 도입되어 전해환원 공정에서 금속으로 환원된 생성물을 처리하게 된다. 전기화학적 공정인 이 두 공정에는 전류전달 매질인 전해질로 용융염이 사용된다. 그러나 전해환원 공정은 LiCl 염을 기반으로 하는 반면 전해정련은 LiCl-KCl 공융염 조건에서 운전하여 두 공정의 연계성 향상 및 공정 안정성 확보를 위해서는 전해환원 공정에서 생성되는 금속전환체에 존재하는 잔류염을 제거하는 공정의 도입이 두 공정사이에 고려되고 있다. 전해환원 공정에서 산화물이 금속으로 환원되는 동안 고체입자의 외형이 유지되며 따라서 제거된 산소에 의해 금속전환체에는 공극이 발생하게 된다. 또한, 전해환원에 도입되는 산화물의 물리적 형태가 분말 또는 펠렛 등 다양한 형태로 도입 가능하여 단위 입자들 사이에 많은 공극이 발생하게 된다. 이렇게 기존재하거나 또는 공정 운전에 의해 새롭게 생성된 공극에는 전해환원 매질인 LiCl 염이 침투하여 금속전환체는 염에 의해 젖게 되며 공정 종료시 고화되어 금속전환체에 포함된다. LiCl을 제거하기 위해서는 가열에 의한 증류가 연구되고 있다. 그러나 LiCl의 낮은 증기압에 의해 비교적 낮은 온도에서 증발시키기 위해서는 감압조건이 필수적으로 고려되어야 한다. 한국원자력연구원에서는 다공성 모의 금속전환체를 사용하여 LiCl에 의한 Wetting 후 적절한 증발 조건 결정을 목적으로 온도 및 압력 조건 설정을 위한 기초실험에 결과를 수행하였다. 본 연구의 기초 실험 결과 $700^{\circ}C$온도 조건과 감압조건이 잔류염 제거를 위한 공정조건임을 밝혔다. 또한 모의 금속전환체를 담고 있는 미세 다공성 Basket은 고온조건에서 공극의 변형에 의해 증발에 대한 저항으로 작용하여 증발 효율을 저하시키는 것으로 나타났다. 따라서 잔류염 제거를 위해서는 전해환원 Basket이 비교적 큰 공극을 지녀야 할 것으로 판단된다.

  • PDF

Effect of Rapid Thermal Annealing on the Properties of Nitrogen-doped $In_2O_3$ Thin Films

  • Tak, Seong-Geon;Kim, Jun-Yeong;O, Seok-Hyeon;Jeong, Min-Jae;Kim, Chun-Su;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.243-244
    • /
    • 2011
  • 최근에 산화물 반도체를 평판 디스플레이와 태양 전지의 투명 전극으로 응용하기 위해 많은 연구가 진행중에 있다. 특히, $In_2O_3$ 박막은 투명 전도 산화막으로써 3.7 eV의 직접 전이 밴드갭 에너지를 갖고 가시광 영역에서 높은 투과도를 갖는 반도체이어서 다양한 영역에서 응용 가능하다. 본 연구는 낮은 비저항과 높은 투과율을 갖는 최적의 투명 전도막을 성장시키기 위하여 라디오파 반응성 마그네트론 스퍼터링 방법을 사용하여 질소 도핑된 $In_2O_3$ 박막을 유리 기판 상부에 증착하였고, 후열처리로 온도 400, 450, 500, 550$^{\circ}C$에서 급속 열처리를 수행하여, 증착된 박막의 구조, 표면, 광학, 전기적 특성을 조사하였다. 증착된 박막은 XRD를 사용하여 구조적 특성을 조사한 결과, $2{\theta}=30.2^{\circ}$와 43.95$^{\circ}$에서 상대적으로 강한 피크가 관측되었다(Fig. 1). 전자는 (222)면에서 회절된 피크이며, 후자는 (100)면에서 발생한 회절 피크이다. 열처리 온도가 0$^{\circ}C$에서 500$^{\circ}C$로 증가함에 따라 (222) 면의 회절 신호의 세기는 상대적으로 증가하였고, 550$^{\circ}C$에서 급격하게 감소하였다. 박막의 광학적 특성은 자외선-가시광선 분광기를 사용하여 광학 흡수율과 투과율을 측정하였다(Fig. 2). 열처리를 하지 않은 박막의 경우에, 파장 200~1,100 nm 범위에서 측정된 평균투과율은 76%이었다. 광학 흡수 계수와 광자 에너지의 관계를 나타내는 포물선 관계식을 기초로 하여 광학 밴드갭 에너지를 계산하였다. 박막의 전기적 특성의 경우에, Hall 효과를 측정하여 전하 운반자 농도, 홀 이동도, 전기 비저항을 조사한 결과, 전기적 특성은 열처리 온도에 상당한 의존성을 나타냄을 알 수 있었고, 열처리 온도 500$^{\circ}C$에서 박막의 비저항값은 $4.0{\times}10^{-3}{\Omega}cm$이었다.

  • PDF

광방사 세기비를 이용한 공정 플라즈마의 변수 진단

  • Lee, Yeong-Gwang;O, Se-Jin;Lee, Jae-Won;Hwang, Hye-Ju;Lee, Hui-Jin;Kim, Yu-Sin;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.149-149
    • /
    • 2011
  • 아르곤 기체의 방사세기 또는 그 세기 비는 플라즈마 공정 진단에서 일반적으로 사용된다. 본 실험에서는 100 mTorr 압력 조건하의 유도결합 플라즈마(13.56 MHz)에서 E-H 모드 전이 영역, rf 바이어스(12.5 MHz) 전력 인가 및 N2 혼합 시 단순화한 충돌-방사 모델에 기초한 광방사 세기비 방법을 적용하여 플라즈마 변수를 진단하였다. 개발 프로그램 기반의 분광기를 사용하여 아르곤 기체의 특정 파장(750.4, 751.5 그리고 811.5 nm)들을 관측하였고, 동일한 조건하에서 정전 탐침법으을 이용하여 전자 에너지 분포함수의 변화도 측정 하였다. 맥스웰 전자 에너지 분포를 가정하는 일반적인 경우와 비교하여 볼 때 실제적인 전자 에너지 분포함수의 측정은 전자의 가열 메커니즘에 대한 상세한 정보를 제공함과 동시에 플라즈마 재흡수에 대한 보정을 가능하게 해준다. 광방사 세기비법에 의해 측정된 결과에 의하면, 750.4 nm/751.5 nm는 높은 에너지(>13.08 eV)의 전자들의 유효 전자온도에 대한 정보를 나타내는 반면 811.5 nm/750.4 nm는 아르곤 준안정 준위 밀도(1s5)에 대한 정보를 제공하게 된다. 수행된 실험 조건하에서, 측정된 준안정 준위 밀도는 E-H 모드 전이 영역에서 최대값을 나타내었고 바이어스 전압 및 N2 기체 혼합 비율이 증가함에 따라 감소하는 결과를 얻었다. 유효 전자온도의 경우 광방사 세기비법과 정전 탐침법 모두 같은 결과를 보여 주었는데, E-H 모드 전이 영역에서는 전자온도는 거의 일정하였고 바이어스 전압 및 N2 기체 혼합 비율이 증가함에 따라 전자온도는 증가하였다. 이러한 실험 결과는 방전 모드 전이, 바이어스 인가 그리고 혼합 기체 사용하는 공정 플라즈마를 이해하는데 있어 이들 변수의 진단이 중요한 요소임을 보여준다.

  • PDF

Retrospective Study of Survival Rates According to the Type of Dental Restoration of Proximal Caries in Primary Molars (치과용 수복재료에 따른 유구치부 인접면 수복물의 생존율연구 : 후향적연구)

  • Jih, Myeongkwan;Lee, Sangho;Lee, Nanyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.249-256
    • /
    • 2015
  • Restorative dental materials have advanced rapidly, with improved physical properties that improve survival rates. Accordingly, various materials can be selected. Amalgam, composite resin, glass-ionomer cement, and preformed stainless steel crowns have all been used widely for the restoration of dental caries in primary molars. The various dental materials used to treat proximal caries in the primary molars have distinct advantages and disadvantages. However, few studies have examined their survival rates. This retrospective study examined the 2-year survival rates of more than 700 class II restorations of proximal caries in primary molars clinically and radiologically according to the type of restoration. The study results should help in the selection of class II restorations for molars, one of the biggest concerns of pediatric dentists.

Analysis of the Polymer Properties and Sound Characteristics of Interlayer Films for Laminated Glass (접합유리용 고분자 필름의 물성 및 음향학적 특성 분석)

  • Ko, Sangwon;Hong, Jiyoung;Sunwoo, Yerim;Kim, Young Jun
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • To improve the sound insulation performance of laminated glass in high speed trains, it is beneficial to study the relationship between the characteristics of interlayer films and the acoustical performance. In addition to those of conventional PVB (polyvinyl butyral), the dynamic mechanical properties of PVB derivatives and PC (polycarbonate), which are candidates for interlayer films, were analyzed. We assumed that PVB-HEMU, which has a glass transition temperature ($T_g$) around room temperature and a large tan ${\delta}$ (loss tangent) value, can be made to damp efficiently. The damping capability was tested utilizing sound transmission loss measurement and simulation under the identical structure of laminated glass in high speed trains. We also built a database for analysis of relations between interlayer film characteristics and acoustical performance; this was followed by the determination of sound transmission loss using the intensity technique and FEA.

Efficient Ontology Object Model for Semantic Web (시맨틱웹을 위한 효율적인 온톨로지 객체 모델)

  • Yun Bo-Hyun;Seo Chang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.2 s.40
    • /
    • pp.7-13
    • /
    • 2006
  • The advent of Semantic Web has generated several methods that can access the data on the web. Thus, it is necessary to handle the data by accessing the current web ontology as well as the existing knowledge base system. Web ontology languages are RDF(Resource Description Framework), DAML-OIL, OWL(Web Ontology Language), and so on. This paper presents the creation and the method of the ontology object model that can access, represent, and process the web ontology and the existing knowledge base. Unlike the existing access approach of web ontology using the model on memory constructed by each parser, we divide the model of web ontology into three layers such as frame-based ontology layer, generic ontology layer, and functional ontology layer. Generic ontology layer represents the common vocabulary among several domains and functional ontology layer contains the dependent vocabulary to each ontology respectively. Our model gets rid of the redundancy of the representation and enhances the reusability. Moreover, it can provide the easy representation of knowledge and the fast access of the model in the application.

  • PDF

On the Development of Authoritative Representations of Torpedo Systems for Engagement Level Simulation (교전수준 어뢰체계 표준모델 개발 방안 연구)

  • Shin, Ji-Hwan
    • Journal of the Korea Society for Simulation
    • /
    • v.16 no.3
    • /
    • pp.19-28
    • /
    • 2007
  • We considered the authoritative representations of torpedo systems that was the engagement level model to develop system specifications and to analyze operational requirements on concept design phase. The Work Breakdown Structure(WBS) of models was defined about authoritative representations of the torpedo systems. The communication of information among each subsystems and input/output parameters were defined. In the heavy weight and light weight torpedo model, presetter, underwater maneuver, war head, sonar, guidance and control, propulsion subsystem modeling were developed for heavy-weight and the light-weight torpedo systems. The authoritative representations of torpedo systems have similar structures with those of the engineering level models and could be verified via engagement level simulations according to the V&V process in the future.

  • PDF

Experimental study of composite beams consisting structural laminated timber beam with concrete slab (구조용집성재보와 콘크리트슬래브로 구성된 합성보의 실험적 연구)

  • An, Hyun-Jin;Kim, Soon-Chu;Moon, Youn-Joon;Yang, Il-Seung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.233-236
    • /
    • 2008
  • In the traditional way floors has been constructed there are no shear connectors between the concrete slab and timber joists. In this study, an existing floor system os improved by simply providing normal bolts or lag screw so that the composite action can be achieved. It is evident that the key elements in the composite beam are the shear connectors. The selection of these connectors was based on their shear capacity. The experimental study carried out in this research investigated the flexural behavior of composite beams. The experimental studies of composite beams showed that the ultimated load capacity of the proposed composite beam(LS-S10 specimen) is 1.29 times as high as the noncomposite one. Finally, it can be concluded that LS-S10 specimen consisting structural laminated timber beam and concrete slab can be significantly improved by providing appropriate shear connectors.

  • PDF

Characterization of Repairing Polyurethane for Trenchless Sewer Pipeline (비굴착 하수관로용 폴리우레탄 보수재 특성 평가)

  • Park, Jun-Ha;Jeon, Sang-Ryeol;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3542-3547
    • /
    • 2015
  • There is commonly used the full depth excavation method of sewer pipeline maintenance in Korea. This induces couple of technical and social problems like increase of construction cost and time for excavation and backfill, increase of public complains and delay of traffic, and so force. In order to overcome these problems, lots of laboratory tests were carried out for sewer pipeline of maintenance materials with trenchless methods. The testing materials are liquid and hardened polyurethane, and polyurethane CIPP. The lab tests were followed by Korean Standard. There are no side effects, like harmless to the human body and air pollution with stink. Judging from the limited test results, all the items tested were satisfied the KS criteria.