• Title/Summary/Keyword: 재료평가

Search Result 6,496, Processing Time 0.035 seconds

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Effect Assessment of Safety Education in Laboratories of Department of Dental Technology Applied of Theory of Planned Behavior (TPB) (TPB 이론을 적용한 치기공학 전공 대학생들의 실습실 안전교육 효과 평가)

  • Park, Jong-Hee;Lee, Myung-Sun
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.9 no.2
    • /
    • pp.15-31
    • /
    • 2008
  • Objective: This study is a quasi-experimental study by nonequivalent control group pretest-posttest design, performed in order to identify whether the program developed on the basis of Ajzen(1988, 1991)'s theory of planned behavior (TPB) for predicting the safety behavior of students of department of dental technology affects intention toward safety behavior and general behavior. Therefore, the purpose of this study is to identify whether the safety education in laboratories in which knowledge is reinforced on the basis of the TPB theory affects safety behavior. Methodology: The theoretical framework of this study was established on the basis of the TPB by Ajzen(1988, 1991). This study was performed between May 20 and December 5, 2006, and the subjects included 101 in the experimental group and 98 in the control group, a total of 199. The experimental group was educated through six 50-minute sessions (twice a week) for three weeks. The experimental group was pretested, educated, and then asked to answer the pro-questionnaire after finishing the sixth session, but the control group was free from intervention. The research tool in this study was developed by the authors with reference to the process of tool development used in Schifter and Ajzen (1985) based on Ajzen and Fishbein(1980)'s tool development guide. Results: The data were analyzed through SPSS 14.0 version. The reliability test of attitude, subjective norm, perceived norm, intention, and behavior toward safety behavior as TPB variables was calculated of Cronbach's alpha coefficient, and general characteristics and the homogeneity test of the experimental and the control groups were analyzed through t test and $X^2$ test. According to the results of the analysis, the experiment group may be higher than the control group after the safety education in the scores of attitude, the subjective norm, the perceived norm, and the intention toward safety behavior as TPB independent variables showed no significant difference, but there was significant difference in the behavior and the knowledge. Meanwhile, according to the results of the pretest and posttest, eleven items in the experimental group and two items in the control group showed significant difference in the behaviors, and twelve in the former and four in the latter were significantly different in the knowledge. Conclusion: The safety education program developed on the basis of TPB was identified to enhance safety behavior and knowledge. Therefore, the safety education program used in this study for students of department of dental technology may be utilized as database for safety education in the department of dental technology.

  • PDF

Construction of Data System on Seed Morphological Traits and Functional Component in Tartary Buckwheat Germplasms (쓴메밀 유전자원의 종자특성과 유용성분 변이에 관한 자원 정보 구축)

  • Kim, Su Jeong;Sohn, Hwang Bae;Hong, Su Young;Lee, Jong Nam;Kim, Ki Deog;Suh, Jong Taek;Nam, Jeong Hwan;Chang, Dong Chil;Park, Min Woo;Kim, Yul Ho
    • Korean Journal of Plant Resources
    • /
    • v.33 no.5
    • /
    • pp.446-459
    • /
    • 2020
  • This study analyzed the phenotypes and chemotypes of 74 tartary buckwheat (Fagopyrum tataricum) germplasms using principal component analysis and cluster analysis. The average seed size of tartary buckwheat germplasm was 5.2 × 3.4 mm, which is smaller than the seed size of common buckwheat. The dark browned colored ovate or elliptic shape was mostly observed in collected germplasm. The average content of rutin was 1,393 mg per 100 g dry weight (DW) in tartary buckwheat seed. Similarly, the flavonoid and polyphenol contents ranged from 253 to 2,669 and 209 to 1,823 mg, respectively, per 100 g DW in the collected germplasm. The three components (PC1, 2, and 3) of principal component analysis revealed 68.55% of the total variance of the collected accessions. Cluster analysis using descriptors showed that 74 accessions were clustered into five groups. The study showed that the most interesting resources for functional breeding programs are: Five resources (HLB1004, HLB1005, HLB1007, HLB1009, and HLB1013) due to the rich rutin, polyphenol, and flavonoid.

Research Trends in Clothing and Textiles Education (의생활교육 연구 동향)

  • Moon, Hee-Kang;Lee, Yhe-Young
    • Journal of Korean Home Economics Education Association
    • /
    • v.21 no.2
    • /
    • pp.109-125
    • /
    • 2009
  • The purpose of this study was to analyze research trends in clothing and textiles education focused on primary and secondary school education. Among the reviewed articles published between 1989 and 2008 in four journals including The Journal of Korean Home Economics Education, The Journal of Korean Association of Practical Arts Education, Journal of the Society of Clothing and Textiles, and Journal of the Korean Home Economics Association, 175 articles were related to clothing and textiles education. The most popular research field was teaching contents followed by teaching-learning method and teaching material, while clothing selection and self-expression, the general focus on home economics education and making clothing and household utensils were the popular research topics. In terms of research methods, about three quarters of articles used survey methods followed by experiment method and documentary studies. The rapid increase in research on clothing selection and self-expression and the decrease in articles on making clothing and household utensils seem to have had an influence on the government revision of The $7^{th}$ Curriculum.

  • PDF

CASE REPORTS OF TREATMENT OF ERUPTION-DISTURBED MX. FIRST MOLAR BY SURGICAL EXPOSURE (맹출 장애를 가진 상악 제1대구치의 외과적 노출을 이용한 치험례)

  • Seok, Choong-Ki;Nam, Dong-Woo;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • The eruption of permanent teeth represents the movement in the alveolar bone before appearance in oral cavity, to the occlusal plane after appearance in oral cavity, and additive movement after reaching th the occlusal plane. Tooth eruption is mostly controlled by genetic signals. The eruption stage is divided to preeruptive alveolar stage, alveolar bone stage, mucosal stage according to the process of growth and development. If the disturbance is occured in any stage of eruption, tooth does not erupt. The cause of eruption disturbance are ectopic position of the tooth germ, obstruction of the eruption path and defects in the follicle or PDL. In the treatment of eruption disturbance, surgical procedures are commonly used. There are three kind of surgical procedure ; surgical exposure, surgical repositioning, surgical exposure and traction Surgical exposure is basic procedure. This involves removal of mucosa, bone, lesion that are surrounding the teeth, dental sac when necessary to maintain a patent channel between the crown and the normal eruptive path into the oral cavity. To ensure this patency, many techniques including cementation of a celluloid crown, packing with gutta-percha or zinc oxide-eugenol, or a surgical pack, are used. When surgical exposure is conducted, operators should not expose any part of cervical root cement and not injure periodontium or root of adjunct tooth. After surgical exposure, tooth should be surrounded by keratinized gingiva. There is direct relationship between the extent of development of pathophysiologic aberrations and the intensity of the manipulative injury inflicted on the tooth by surgical treatment, so operator should consider this thing. In these cases, surgical exposure is conducted on Maxillary 1st milars that have a eruption disturbance and improve the eruption disturbance effectively.

  • PDF

A STUDY ON THE MICROLEAKAGE OF DENTIN BONDING SYSTEMS (상아질 접착제의 미세누출에 관한 연구)

  • Son, Jeong-Min;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho;Park, Yang, Ji-il
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.619-627
    • /
    • 2008
  • The objective of this study was to compare the microleakage of five adhesive systems in the enamel and dentin of permanent teeth. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 25 extracted human molar teeth. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM), Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL) and G-Bond (GB). The results were as follows: 1. At the enamel margins, PL showed the highest leakage value(0.85), and others showed values of SB(0.55), GB(0.50), SM(0.35) and SE(0.25) in decreasing order. There were statistically significant differences in PL vs. SM and PL vs. SE(p<0.05). 2. At the dentin margins, GB showed the highest leakage value(2.10), and others showed values of SE(1.45), PL(1.40), SB(1.05), SM(0.70) in decreasing order. There were statistically significant differences in GB vs. SB and GB vs. SM(p<0.05). 3. Dentin margins showed high dye penetration rate than enamel margins in all material tested groups and there were statistically significant differences for SE, PL and GB.

  • PDF

Influence of crestal module design on marginal bone stress around dental implant (임플란트 경부 디자인이 변연골 응력에 미치는 영향)

  • Lim, Jung-Yoel;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.224-231
    • /
    • 2010
  • Purpose: This study was to investigate how the crestal module design could affect the level of marginal bone stress around dental implant. Materials and methods: A submerged implant of 4.1 mm in diameter and 10 mm in length was selected as baseline model (Dentis Co., Daegu,Korea).A total of 5 experimental implants of different crestal modules were designed (Type I model : with microthread at the cervical 3 mm, Type II model : the same thread pattern as Type I but with a trans-gingival module, Type III model: the same thread pattern as the control model but with a trans-gingival module, Type IV model: one piece system with concave transgingival part, Type V model: equipped with beveled platform). Stress analysis was conducted with the use of axisy mmetric finite element modeling scheme. A force of 100 N was applied at 30 degrees from the implant axis. Results: Stress analysis has shown no stress concentration around the marginal bone for the control model. As compared to the control model, the stress levels of 0.2 mm areas away from the recorded implant were slightly lower in Type I and Type IV models, but higher in Type II, Type III and Type V models. As compared to 15.09 MPa around for the control model, the stress levels were 14.78 MPa, 18.39 MPa, 21.11 MPa, 14.63 MPa, 17.88 MPa in the cases of Type I, II, III, IV and V models. Conclusion: From these results, the conclusion was drawn that the microthread and the concavity with either crestal or trans-gingival modules maybe used in standard size dental implants to reduce marginal bone stress.

Study of the re-osseointegration of implant fixture after mechanical unscrewing (임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구)

  • Jang, Ji-Hoon;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.209-214
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate whether the re-osseointegration of the implants that had mechanical unscrewing possibly occurred or not. Furthermore, if it happened, the degree of re-osseointegration was evaluated by comparing with previous osseointegration. Materials and methods: The smooth implant (commercial pure titanium 99%) specimens, whose diameter and length was 3.75 mm, 4 mm, respectively were produced. Two implants were inserted into each tibia of 7 New Zealand female white rabbits weighing at least 3.0 kg. The torque removal force for each implant after 6 weeks of implants placement was measured and included in group I. The torque removal forces were assessed after the fixtures were re-screwed to original position and the subjects were allowed to have 4 more weeks for healing and included in group II. One rabbit was sacrificed after first measurement and produced 4 slide specimens in group I, and two rabbits were sacrificed after 2nd measurement, 7 slide specimens, in group II for histomorphologic investigations. All slide specimens were assessed based on the proportion of BIC (bone-implant contact) as well as CBa (Bone area in the cortical passage) value produced by counting the screw threads embedded in the compact bones under the optical microscopic analysis (${\times}20$). Statistical analysis was conducted to evaluate the torque removal force, BIC and CBa between group I and II. Results: As for the torque removal force, the result was $10.8{\pm}3.6$ Ncm for group I and $20.2{\pm}9.7$ Ncm for group II. Furthermore, the torque removal force of group II increased by 98.1% in average compared to group I (P<.05). On the other hand, histomorphologic analysis displayed that there was no statistical significance in BIC and CBa values between group I and the group II (P>.05), and RT/BIC and RT/CBa between group I and group II were statistically significant (P<.05). Conclusion: It is possible to obtain more substantial re-osseointegration within shorter periods than the period needed for the initial osseointegration in case of iatrogenically unscrewed implants.

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

Rationalizing Strategies for Children's Activity Spaces and Facilities (어린이 활동공간 및 놀이시설 제도 합리화 방안)

  • Park, Mi-Ok;Koo, Bon-Hak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.36-50
    • /
    • 2012
  • This study was carried out to find contradiction factors on laws for children's activity spaces and facilities and to suggest the rational options to control and manage those spaces and facilities by environmental and landscape planning methods. The results of this study are as follows: 1. The major laws related to the environmental safety for children's activity spaces are "Environmental Health Act (ERA)" for managing the environmental safety of children's activity spaces; "Safety Supervision Law of Children's Play Facilities(SSLCPF)" for the inspection and management for safety of children's play facilities; "Quality Management and Industrial Products Safety Management Law(QMIPSML)" for managing safety certification on children's play equipments. 2. The interior space such as "living room" by the Children's Welfare Law(CWL), "Children Park" by the Act on Urban Parks and Green Spaces(AUPGS), "classroom" on private educational institutes by the Act on Establishment and Operation Private Lesson and Training(AEOPLT) and "nursing room" of child care center smaller than $430m^2$ are needed to be managed as an activity space. 3. In order to reduce industrial burden in the production, establishment, construction, and operation and to minimize unwilling extra burden in the administration effort due to legally double regulate, it is necessary to mitigate the inspections on the equipment certificate from QMIPSML and overlapped or different factors and standards must be unified. With this study, the landscape domain could he enlarged from producing, import of play equipment and establishment, construction and operation of play facilities for a comprehensive range of activity spaces, and the landscape industry such as engineering industry, academic research, management, etc.