• Title/Summary/Keyword: 장치장 모니터링

Search Result 32, Processing Time 0.027 seconds

Generating Tool for Visualization System in Real-time Field Monitoring (실시간 현장 감시를 위한 가시화 시스템 생성 도구)

  • Park, Bokuk;Tak, Haesung;Lee, Chae-Ho;Cho, Hwan-Gue
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.54-63
    • /
    • 2014
  • It is general that the field plant is too large to be monitored by human works. So it is crucial to prepare one automated monitoring system to prevent unexpected accidents in advance. However, most of previous monitoring systems were to be implemented by human programmer independently, so the total developing cost of a set of similar monitoring systems is so high. In order to overcome this disadvantage, we propose a new specification language for meta-description of monitoring system. Also we propose a generation tool for monitoring system with the input meta-description files. Using these meta-description files, we show it is so fast and effective to get a new monitoring system for a specific field plant. In experiment we have shown that our generation system work successfully in newly developing a monitoring system for the water-vessel plant.

Runoff Reduction Effect Analysis of Porous Asphalt Using Rainfall Simulator of Movable-Assemble Type (이동형 강우모의장치를 이용한 투수성 아스팔트 유출저감 효과 분석)

  • Jang, Youngsu;Park, Jaerock;Chun, Jonghyun;Park, Jaehyun;Shin, Hyunsuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.382-382
    • /
    • 2018
  • 최근 기후변화 및 도시화로 인해 집중호우와 도시 내의 불투수층이 증가하고 있으며, 현재 도심의 강우관리시스템이 한계에 달하여 수재해 피해가 급증하고 있다. 이와 같은 문제를 해결하기 위한 방안으로 저영향개발 기법이 대두되고 있으며, 본 기법은 해당 지역의 강우를 분산식 빗물처리 하여 도시 내의 수문학적 특성을 개발이전 상태로 회복 및 유지하는 기술이다. 저영향개발 기법의 종류는 투수성 포장, 옥상녹화, 빗물정원, 식생저류지, 식생화분 등이 있다. 본 연구에서는 저영향개발 기법 중 하나인 투수성 아스팔트에 대한 우수저감 효과를 분석하기 위해 경상남도 양산시 부산대학교 양산캠퍼스 그린인프라 저영향개발 센터에서 주차장형 LID 시설의 투수성 아스팔트 포장과 대조군인 불투수 콘크리트 포장을 실험대상으로 선정하였다. 포장체는 $10.85m(L){\times}2.3m(B){\times}0.9 m(H)$의 크기로 원지반 침투가 없는 박스형 실험시설로써 이동형 강우모의장치를 이용하여 인공강우실험을 실시하였다. 강우모의 시에 발생하는 지표유출 및 침투유출은 각 유공관을 통해 모니터링 박스에 차집되어 실시간으로 웹사이트 상에 저장된다. 저장된 자료를 이용하여 투수성아스팔트의 첨두유출량 저감, 지체시간지연효과를 분석하였다. 분석된 결과를 통해 첨두유출량은 11%저감되었고 투수성 아스팔트와 불투수 콘크리트는 각각 3시간, 1시간 동안 유출되어 2시간의 차이를 보여준다.

  • PDF

Development and Application for Stable Technology Agricultural Water Management in Recurrent Drought Areas of Geum River Basin (금강권역 상습 가뭄지역의 안정적인 농업용수 공급관리 기술 개발 및 적용)

  • Kim, Da Ye;Hong, Eun Bi;Maeng, Seung Jin;Lee, Gwang Ya;Park, Ji Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.74-74
    • /
    • 2021
  • 우리나라의 농업용수 사용량은 152억톤으로 우리나라 전체 물 사용량의 약 42%이며, 농업용수의 관리는 전체 논 면적 865천ha 중 한국농어촌공사에서 487천ha(56%), 지방자치단체에서 221천 ha(26%), 수리 불안전답이 157천ha(18%)이다. 또한 우리나라에 설치된 저수지, 양수장 등과 용수로로 공급되는 농업용수 공급량 중 논에 유입되지 못하고 퇴수되는 물이 약 43%이다. 농업용수 급수 중 용수로의 수위가 낮아 급수관을 통해 논에 유입되지 못하고 배수로로 퇴수되고 있는 실정이다. 농업용수 급수가 원활하기 위해서는 용수로의 수위를 20cm이상 확보하여야 급수관을 통해 논에 급수가 가능하다. 하지만 현장에서는 이러한 물 공급의 문제점을 해결하기 위해 용수로를 비료포대 등으로 막아서 사용함으로써 용수로 시설물의 관리가 되지 않고 토사가 쌓여 급수 애로가 가중되는 상황으로 시설물 관리를 위한 용수로 준설 등 시설 유지관리비가 발생하고 있다. 특히 금강권역(금강, 만경강, 동진강, 삽교천, 충남 서북부)에서 상습적인 가뭄 발생으로 농업용수 사용에 관한 분쟁이 상시적으로 도사리고 있는 실정이다. 이러한 문제를 해결하기 위해 농업용수의 급수 손실을 최소화하며 원활하고 안정적인 용수를 공급하고자 하였으며, 농민을 대상으로 설문지를 작성하여 응답을 분석하고 농민들의 요구사항을 개선하기 위해 법·제도, 거버넌스, 재원 및 기술·시설로 구분하여 제시하였다. 또한 과거 관행에 의한 유말부 용수공급에 탈피해서 원활한 용수공급이 가능하고 유지관리가 쉬운 장치인 부력식 제수문을 선정하고 제시하였다. 따라서 본 연구에서는 금강권역 상습 가뭄지역의 안정적인 농업용수의 공급관리를 위한 기술 개발 및 적용을 실시하고, 농업용수 공급관련 정량화된 손실현황을 분석한 후 수위확보 장치 적용 전·후 모니터링으로 효과 분석을 실시하였다.

  • PDF

Reliability of Infrared Thermographic Imaging in the Orofacial Region (구강안면부에서 적외선 체열검사의 신뢰도에 관한 연구)

  • Han, Dong-Joon;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.4
    • /
    • pp.355-367
    • /
    • 2001
  • 치의학 분야에서 디지탈 근적외선 체열측정 장치(digital infrared thermographic imaging; DITI)의 응용이 미미한 것은 과거 열측정장치의 기술력이 부족한 것이 주된 요인이었다. 그러나 최근들어 기술이 진보함에 따라 실시간 열영상을 재현할 수 있게 되었고 이는 치의학 및 의학계에 많은 관심을 일으키고 있다. 지금까지의 연구를 보면 두개하악장애시 구강영역의 온도변화의 임상적 효용 가능성을 제시하였으나 안면 및 두경부에 대한 실제 기기 및 측정방법의 신뢰도에 대한 연구는 이루어지지 못한 상태이다. 본 연구에서는 DITI에 대한 신뢰도를 조사하였다. DITI의 모니터 상에서 비활동성 발통점의 부위를 찾아내기가 쉽지 않다. 따라서 모니터상에서 안면발통점(joint, temporalis anterior, masseter anterior, masseter inferior)의 부위를 찾아 온도를 찾아내는 방법과 미리 발통점 피부상에 링모양의 마크를 부착하여 모니터상에서 쉽게 찾아내는 방법을 사용하여 신뢰도를 조사하여 비교한 결과 다음과 같다. 1. 조사한 발통점 중에서 temporalis anterior, joint, masseter anterior과 masseter inferior의 순서로 피부온도가 유의하게 온도가 높았으나(p<0.05) masseter 내에서는 유의한 차이를 보여주지 않았다. 2. 4개의 발통점 모두에서 높은 열적 대칭성을 보였으며, 좌우 온도차이는 $0.1^{\circ}C$미만이었다. 3. 다른 시기에 조사한 조사자내 신뢰도는 두 조사자 모두 높은 상관관계를 보여주지 않았으며 대조군과 마크를 사용한 군간에는 뚜렷한 차이를 볼 수 없었다. 4. 동일한 시기에 조사한 조사자간 신뢰도는 두 시기 모두 joint 부위의 일부를 제외하고 높은 상관관계를 보여주었으며, 마크를 사용한 경우 사용하지 않은 경우 보다 훨씬 신뢰도가 높은 상관관계를 나타내었다. 이상의 결과로 보아 DITI는 두개하악장애환자에 대한 두경부 발통점의 온도변화를 측정하는 데 있어 시간에 따른 신뢰도는 결여되었으나 동일 시기의 측정에는 매우 유익할 것으로 사료되며, 특히 발통점에 대한 표시를 사용하는 경우 매우 정확한 온도를 조사할 수 있을 것으로 판단된다.

  • PDF

Development of air-conditioning and drinking water supply system using air-water heat pump (공기-물 히트펌프를 이용한 공조 및 음용수급수시스템 개발)

  • Paek, Yee;Kang, Sukwon;Jang, Jae-Kyung;Kim, Young-Hwa
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.118-118
    • /
    • 2017
  • 지구 온난화에 따른 환경변화로 인하여 최근 10년('02~'11)간 여름의 일수는 4일, 겨울 일수는 16일 각각 증가하였다. 현재 육계사 내의 고밀도 밀집사육으로 인하여 고온스트레스로 하절기 육계의 폐사율이 증가하고 있는 실정이다. 2016년 폭염으로 닭 406.1천수, 오리 15.7천수, 메추리 70천수, 돼지 8천수가 폐사하였다. 이에 혹서기 가축이 약430만수가 폐사하였으며 피해 보상금액 128억원 소요되었다. 본 연구에서는 하절기 고온스트레스 경감과 폐사율 저감을 위해 계사 냉난방 공조와 냉온 음용수 급수를 병행할 수 있는 고효율 환경 개선 시스템을 개발하여 고온스트레스 저감 및 생산성 향상에 목적이 있다. 계사 냉난방 공조 및 냉온음용수 급수 병행 시스템 설계요인을 분석하고 냉난방 공조부하, 냉온수 생산 부하를 고려한 시스템 용량 산정하고 히트펌프, 축열조, 냉난방 및 냉온수 분배장치 등 구성요소로서 공조 및 냉온음용수 급수시스템을 설치하였다. 시스템 용량은 공기-물 히트펌프(10kW,1대), 축열조(10톤), 음용수조(2톤), 열교환기(열교환량,5만kcal/h), 물순환펌프(250W,2대) 및 팬코일유닛(1만kcal/h,4대)으로 시스템 모니터링 및 제어 시스템 개발하여 계사 내 환경, 시스템 성능에 대한 실시간 모니터링을 통하여 저장하였다. 조사항목으로 위치별 온습도, 체중, 사료섭취량, 페사율 등을 조사 분석하였다. 연구결과 계사의 내부온도는 시험구에서는 평균 $25.3^{\circ}C$를 나타내었고 대조구에서는 평균 $28.1^{\circ}C$로서 $2.8^{\circ}C$ 높게 나타났으나 상대습도는 시험구 76.2%, 대조구 75.0%로 큰 차이가 없었다. 냉수급여에 따른 계사 높이별 내부온도는 상하의 온도차가 $4.5^{\circ}C$로 크게 차이가 났다. 육계의 음수량은 혹서기 냉수를 급여한 시험구에서 일일 23.2L, 대조구에서는 21.5L를 섭취하였다. 일일 사료섭취량은 냉수를 급여한 시험구에서 937g, 대조구에서는 725g을 섭취하였다. 사료섭취량은 냉수를 급여한 시험구가 212g 많이 섭취하였으며 사료요구율은 시험구는 1.86, 대조구는 1.91로서 시험구가 낮게 나타났다. 체중은 냉수를 급여한 시험구가 359g 많았으며 증체량은 냉수를 급여한 시험구에서 495g, 대조구에서는 392g으로 나타났다. 폐사율은 냉수를 급여한 시험구에서 84%가 폐사율을 줄일 수 있었다.

  • PDF

Study of system using load cell for real time weight sensing of artificial incubator (인공부화기의 실시간 중량감지를 위한 로드셀을 이용한 시스템 연구)

  • jeong, Jin-hyoung;Kim, Ae-kyung;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.2
    • /
    • pp.144-149
    • /
    • 2018
  • The eggs are incubated for 18 days through the generator and incubated in the developing incubator. During the developmental period, the weight loss of the fetus is correlated with the ventricular formation, and the proper ventricular formation is also associated with the healthy embryonic hatching and the egg hatching rate. However, in the incubator period of the domestic hatchery, it is a reality to acquire the resultant side by the Iranian standard weight measurement with the experience of the hatchery and the person concerned and the development period without the apparatus for measuring the present weight. As a result, prevalence of early mortality, hunger and illness during hatching are frequent. Monitoring the reduction of weaning weight is crucial to obtaining chick quality and hatching performance with weight changes within the development machine. Water loss is different depending on the size of eggs, egg shell, and elder group. We can expect to increase the hatching rate by measuring the weight change in real time and optimizing the ventilation change accordingly. There is a need to develop a real-time measurement system that can control 10 to 13% reduction of the total weight during hatching. The system through this study is a way to check the one - time directly when moving the existing egg, and it is impossible to control the measurement of the fetal water evaporation within the development period. Unlike systems that do not affect the hatching rate, four load cells are connected in parallel on the Arduino sketch board and the AT-command command is used to connect the mobile phone and computer in real time. The communication speed of Bluetooth was set to 15200 to match the communication speed of Arduino and Hyper-terminal program. The real - time monitoring system was designed to visually check the change of the weight of the fetus in the artificial incubator. In this way, we aimed to improve the hatching rate and health condition of the hatching eggs.

Implement module system for detection sudden unintended acceleration (자동차급발진을 감지하기 위한 모듈 시스템 구현)

  • Cha, Jea-Hui;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.255-257
    • /
    • 2017
  • These days automotive markets are launching models that include a variety of IT technologies. Tesla's Tesla model S and Google's unmanned automobiles are emerging one after another. This type of automobile with IT technology provides various convenience to the driver and the driver is getting benefit by various conveience services. on the contrary, it is also true that defects for errors in electronic components cause accidents that threaten the safety of drivers. There is a sudden unintended acceleration among these accidents. The cause of the accident is not clear yet, but the claim that the ECU device caused by the magnetic field causes accident of the car due is the most reliable. But, in Korea, when occur a car sudden unintended acceleration accident, the char maker often claims that an accident occurred due to driver's pedal malfunction. Also most drivers are responsible for the lack of grounds to refute. In this paper, the pedal operation image of the driver is acquired and the sensor is attached to the control part such as the excel and brake so as to discriminate whether the vehicle sudden unintended acceleration accident is the driver's pedal operation error or the fault of. i have implemented a system that can do this.

  • PDF

On-line Monitoring of the Flocs in Mixing Zone using iPDA in the Drinking Water Treatment Plant (정수장 응집혼화공정에서의 응집플럭 연속 모니터링)

  • Ga, Gil-Hyun;Jang, Hyun-Sung;Kim, Young-Beom;Kwak, Jong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.263-271
    • /
    • 2009
  • This study evaluated the flocs forming characteristics in the mixing zone to increase the coagulation effect in the drinking water plant. As a measuring tool of formed flocs, on-line particle dispersion analyzer (iPDA) was used in Y drinking water plant. To evaluate the forming flocs, many parameters such as poly amine, coagulant dosing amount, raw water turbidity, and pH was applied in this study. During the periods of field test, poly aluminium chloride (PACl) as a coagulant was used. With the increase of the raw water turbidities, poly amine was also added as one of aids for increasing in coagulation efficiency. The turbidity and pH of raw water was ranged from 7 to 9 and from 25 to 140 NTU, respectively. The increasing of raw water turbidity brought the bigger floc sizes accordingly. From a regression analysis, $R^2$ value was 0.8040 as a function of T, raw water turbidity. Floc size index (FSI) was obtained from a correlation equation as follows; FSI = 0.9388logT - 0.3214 Also, polyamine gave the bigger flocs the moment it is added to the coagulated water in the rapid mixing zone. One of parameters influencing the floc sizes was the addition of powdered active carbon(PAC) in the mixing zone. In case of higher turbidity of raw water, $R^2$ value was 0.9050 in the parameters of [PACl] and [PAC]; FSI = $0.0407[T]^{0.324}[PACI]^{0.769}[PAC]^{0.178}$ On-line floc monitor was beneficial to evaluate the flocs sizes depending on the many parameters consisting raw water properties, bring the profitable basic data to control the mixing zone more effectively.

Pilot-Scale Evaluation of Granular Filters Using Particle Distribution Analysis (여재구성에 따른 탁질입자 제거특성 및 효율 비교)

  • Ahn, Jong-Ho;Yoon, Jae-Heung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.919-926
    • /
    • 2000
  • The experiment in this study was conducted as a part of an effort to evaluate filter performance with pilot-filters consisting of one mono-media and two dual-media columns. Particle distribution analysis using a particle counter is more sensitive and better than turbidity analysis in observing particle detachments and a breakthrough. In sand media filters having 1.5 m of available head, caution is needed in the head loss of the late stages of filtration, and for dual-media filters, appropriate media configuration and effluent Quality monitoring should be used for preventing the final breakthrough. Also the time of particle breakthrough in the dual media filter can be deferred by increasing bed depth, and it is necessary to use a filtration aid prior to filtration to prevent breakthrough of these intermediate sized particles in high filtration rate.

  • PDF

Water Quality Improvement of Stagnant Water using an Upflow Activated Carbon Biofilm Process and Microbial Community Analysis (상향류 활성탄 생물막 공정을 이용한 정체 수역 수질 개선 및 공정 내 미생물 군집 해석)

  • Oh, Yu-Mi;Lee, Jae-Ho;Park, Jeung-Jin;Choi, Gi-Choong;Park, Tae-Joo;Lee, Tae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.23-32
    • /
    • 2010
  • The capacity of natural purification was limited by the interruption of natural flow and the problems such as eutrophication were occurred by nutritive salts accumulation in stagnant stream. Moreover, the inflow of non-point sources causes non-degradable materials to increase in stagnant stream. In this study, an upflow biological activated carbon (BAC) biofilm process comprised of anoxic, aerobic 1, and aerobic 2 reactors were introduced for treatment of stagnant stream and SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN, and TP were monitored in the upflow BAC biofilm reactors with continuous cycling. In order to simulate stagnant stream, the lake water of amusement park and golf course were stored as influent in a tank of $2m^3$ and hydraulic retention time (HRT) was changed into 6, 4, and 2 hours. At HRT 4hr and the lake water of amusement park as influent, the removal efficiencies of SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN, and TP showed the best water quality improvement and were 69.8, 83.0, 91.3, 74.1, 74.7, and 88.9%, respectively. At HRT 4hr and the lake water of golf course as influent, the removal efficiencies of SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN and TP were 78.5, 78.0, 80.2, 74.9, 55.6 and 97.5%, respectively. As the results of polymerase chain reaction - denaturing gel gradient electrophoresis (PCR-DGGE), microbial community was different depending on influent type. Fluorescence in situ hybridization (FISH) showed that nitrifying bacteria was dominant at HRT 4 hr. The biomass amount and microbial activities by INT-DHA test were not decrease even at lower HRT condition. In this study, the upflow BAC biofilm process would be considered to the water quality improvement of stagnant stream.