• Title/Summary/Keyword: 장치위치 결정

Search Result 300, Processing Time 0.029 seconds

Size and Retention of Tongue Bulb for Tongue Retaining Device (혀 유지구의 크기와 유지력 평가)

  • Park, Nam-Seon;Lee, Ki-Ho;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • In several treatment modalities for snoring and obstructive sleep apnea (OSA), oral appliances mainly including mandibular advancement appliance (MAA) and tongue retaining device (TRD) are recognized as a non-invasive, reversible alternative with favorable results. Tongue bulb is a major component of TRD which prevents the tongue from approaching the posterior wall of the pharynx and can be combined with MAA. Determination of tongue bulb size for the patient is important for therapeutic effect, but frequently needs time-consuming work. For effective fabrication and standardization of tongue bulbs, this study aimed to categorize tongue bulb size for healthy young men and to examine its relation with maximum retention force and with physical parameters including tongue-related variables. 36 non-snoring, asymptomatic young men with normal occlusion were voluntarily participated in this study (mean age: $24.47{\pm}2.58$ years). Experimental procedures consisted of prefabrication of tongue bulb set (20 types with a width of 27-36mm and thickness of 8 and 10 mm), determination of tongue bulb size and the maximum retention force for each subject, and measurement of physical parameters including body mass index (BMI), neck circumference and width, thickness and length of tongue. This study showed that there was significant difference of retention force among the bulb size-related groups both in upright and supine position (p<0.05) and that retention force increased with bulb size. Correlation of tongue bulb size with physical parameters was not clearly verified and there was no significant difference in retention force between upright and supine positions. Based on our results, it can be suggested that retention force relates with tongue bulb size, ultimately with tongue volume. A further study needs to be performed in the patients with snoring and OSA.

Experimental Study on the Determination of Heat Transfer Coefficient for the KURT (KURT 내 열전달계수 결정에 관한 실험적 연구)

  • Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.507-516
    • /
    • 2009
  • In cases of high-level radioactive waste repositories, heat load is apparent by radioactive waste decay. The safety of a waste repository would be influenced by changing circumstances caused by heat transfer through rock. Thus, a ventilation system is necessary to secure the waste repository. The first priority for building an appropriate ventilation system is completing a computer simulation research with thermal rock properties and a heat transfer coefficient. In this study, the heat transfer coefficient in KURT was calculated using the measurement of inner circumstance factors that include dry bulb and wet bulb temperature, rock surface temperature, and barometric pressure. The heater that is 2 m in length and 5 kw in capacity heats the inside of rock in the research module by $90^{\circ}C$. As a result of determining the heat transfer coefficient in the heating section, the changes of heat transfer coefficient were found to be a maximum of 7.9%. The average heat transfer coefficient is approximately 4.533 w/$m^2{\cdot}K$.

원형도파관을 이용한 Ku-band BPF 설계

  • Jeon, Hyeong-Jun;Gang, Chang-Su
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1273-1278
    • /
    • 2005
  • In this thesis, a 2 stage 6-pole bandpass filter(BPF) is designed and implemented by using triple-mode cavity for satellite payload system. The BPF has a 100MHz bandwidth at the center frequency of 14.5GHz(Ku-band) and the response of the filter is the Chebyshev function. The cavity filter uses two orthogonal $TE_{113}$ modes and one $TM_{012}$ mode. The coupling between the adjacent cavityes(intercavity coupling) results in a Chebyshev response and is accomplished by only H-filed component of TE modes. The size and location of intercavity slot is determined by the coupling equation from E- and H-field of TE and TM resonant modes in circular cavity. The 2-stage 6-pole triple-mode cavity BPF has the insertion loss of 2.4dB and the reflection loss of 15dB in the passband. The triple-mode BPF proposed in this thesis can be used as channel filters for satellite payload system and can minimize filter assembly in general wireless communication system.

  • PDF

Vibration Control for Tower of Suspension Bridge under Turbulence using TMD (난류하에서의 TMD에 의한 현수교 주탑의 진동제어)

  • Kim, Ki Du;Hwang, Yoon Koog;Byun, Yun Joo;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.181-191
    • /
    • 1997
  • Before cables are constructed, tower of suspension bridge is behaved as a cantilever type. Buffeting occured by unsteady loading of the tower due to velocity fluctuation in the oncoming flow has a wind velocity consistent with fundamental frequency of the tower and may give rise to large response by the tower resonance. To reduce the dynamic response by buffeting, the behavior of tower with TMD(Tuned Mass Damper) has studied using finite element method in time domain. The buffeting was obtained by transforming the velocity spectrum in frequency domain to random variable in certain time domain. The most probable maximum displacement which can be occured during the time interval was obtained using peak factor. The optimum location for TMD installation and TMD specification were decided by parametric study. Also, the effect of vibration control about various wind velocity was studied by the TMD which has optimum specification and location.

  • PDF

Degradation Diagnosis of Complex System Using Regression Analysis (희귀분석을 이용한 복합 시스템의 열화진단)

  • Kim, Seong-Hong;Song, Jae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.60-66
    • /
    • 2001
  • Because of internal voids in insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This is in agreement with the results of the research by Yoshimura and Fujita.

  • PDF

Evaluation of Effects on Impact Resonance Test for Determining Modulus of Asphalt Concrete (아스팔트 콘크리트 탄성계수 결정을 위한 충격공진시험 영향요소 평가)

  • Kweon, Gi-Chul;Lee, Jae-Hoan
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.89-99
    • /
    • 2007
  • The stiffness of the asphalt concrete is represented by the complex modulus $E^*$, which is very important properties in the mechanistic design of flexible pavement system. The moduli of asphalt concrete were generally determined by dynamic modulus test. However, the dynamic modulus testing method is too complex, expensive, and time consuming to be applicable on a production basis. The IR(Impact Resonance) method has been shown to be a truly simple nondestructive testing method which produces very repetitive, consistent results. The major object of this study was to estimate of the effects on IR tests for determining modulus of asphalt concrete including impact position, specimen support condition, impact steel ball size and sampling rate. The variations of IR test results with various testing conditions are within ${\pm}2.7%$.

  • PDF

The Study of the Robustness Analysis of the autopilot for the UAV (무인항공기 자동조종장치의 강건성 해석에 관한 연구)

  • Lim, Ho;Kim, Ki-Yeol;Kim, Ho
    • The Journal of Information Technology
    • /
    • v.4 no.3
    • /
    • pp.165-170
    • /
    • 2001
  • In this paper, we proposed an autopilot of the unmanned piloted vehicle to guide to the specific position and analyzed robustness of the designed autopilot. We divide an aircraft velocity into the three case which are low, crusing and high speed, and designed autopilot gains are gain scheduled. We generated the turbulence for the operational altitudes and analyzed performance of the autopilot about it. We proved robustness of the designed autopilot for the turbulence and gust using simulation.

  • PDF

The importance of plant location decision-making in the petrochemical industry (석유화학업체의 플랜트 입지 선정의 중요성에 대한 연구)

  • Jung, Yoon-Jung;Woo, Su-Han;Park, Keun-Sik
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.1
    • /
    • pp.127-145
    • /
    • 2015
  • Plant location selection is a decision which requires huge investment and entails a significant impact in a longer-term. The petrochemical industry, in particular, is so capital- and technology-intensive that the firms in the industry pursue enhancing competitiveness through collaboration and integration among entities in their supply chains. Even though the logistics factor such as logistics costs and connectivity have, as a result, gained its importance in plant location decision making, this has rarely studies in empirical studies. Therefore, this study aims to examine the relative importance of the logistics factor in plant location decision making in the petrochemical industry using the multi-criteria decision-making approach. In addition the three representative petrochemical industrial complexes are evaluated by the factors used in this study. This study is able to provide the useful implication in both practical and policy-making aspects. Firms are required to consider the logistics factors with priority compared to other factors in plant location decision making. In addition, when federal or local governments build industrial sites and attract the petrochemical firm, logistics infrastructure should also be considered to provide better transportation connectivity and lower logistics costs in turn.

The Design of Ku-Band Cavity BPF (Ku-Band Cavity BPF설계)

  • Jeon, Hyung-Joon;Kang, Chang-Soo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.4
    • /
    • pp.69-76
    • /
    • 2005
  • In this paper, a 2 stage 6-pole bandpass filter(BPF) is designed and implemented by using triple-mode cavity for satellite payload system. The BPF has a 100MHz bandwidth at the center frequency of 14.5GHz(Ku-band) and the response of the filter is the Chebyshev function. The cavity filter uses two orthogonal $TM_{113}$ modes and one $TM_{012}$ mode. The coupling between the adjacent cavityes(intercavity coupling) results in a Chebyshev response and is accomplished by only H-filed component of If modes. The size and location of intercavity slot is determined by the coupling equation from E-and H-field of TE and TM resonant modes in circular cavity. The 2-stage 6-pole triple-mode cavity BPF has the insertion loss of 2.4dB and the reflection loss of 15dB in the passband. The triple-mode BPF proposed in this thesis can be used as channel filters for satellite payload system and can minimize filter assembly in general wireless communication system.

Determination of Phase Velocity Dispersion Curve and Group Velocity of lamb Waves Using Backward Radiation (후방복사를 이용한 램파의 위상속도 분산과 군속도의 측정)

  • 송성진;권성덕;정용무;김영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • The guided wave has been widely employed to characterize thin plates and layered media. The dispersion curves of phase and group velocities are essential for the quantitative application of guided waves. In the present work, a fully automated system for the measurement of backward radiation of LLW has been developed. The specimen moves in two dimensional plane as well as in angular rotation. The signals of backward radiation of LLW were measured from an elastic plate in which specific modes of Lamb wave were strongly generated. Phase velocity of the corresponding modes was determined from the incident angle. The generated Lamb waves propagated forward and backward with the leakage of energy into water. Backward radiated LLW was detected by the same transducer and its frequency components were analyzed to extract the related information to the dispersion curves. The dispersion curves of phase velocity were measured by varying the incident angle. Moving the specimen in the linear direction of LLW propagation, group velocity was determined by measuring the transit time shift in the ultrasonic waveform.