• Title/Summary/Keyword: 장축

Search Result 245, Processing Time 0.029 seconds

A study on the change of alveolar crest height following orthodontic treatment (교정치료와 관련된 치조골 높이 변화에 대한 연구)

  • Kang, Kyung-Hwa;Lee, Kyung-Won;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.599-611
    • /
    • 2000
  • Alveolar crest is the section of interproximal alveolar bone which includes the free edge of the alveolar process. An increase of the normal forces within limits of tolerance leads to deposition of new bone. If forces are beyond the limits of tolerance, resorption of bone will result whether the force produces pressure or tension. This study was designed to evaluate changes of alveolar bone levels in mesial and distal surface of the left, right first molar, by using pre-treatment, post-treatment panorama films. Two hundreds sixteen subjects were divided into adolescent group of 104 subjects and adult group of 112 subjects, to which orthodontic treatment with a bicuspid extraction (adolescent group-50 subjects, adult group-50 subjects) or without a nonextraction (adolescent group-54 !subjects, adult group-62 subjects) was applied by fixed appliances. Pre- and post-treatment Panorama films were traced, and alveolar crest height was measured. Amounts of changes in alveolar crest height by treatment were calculated md compared in terms of side of tooth, extraction, age. The results were as follows ; 1. When pre-treatment alveolar crest bone levels were compared, levels of adult group were significantly lower than those of adolescent group. 2. Post-treatment alveolar crest bone levels were significantly lower than pre-treatment levels. 3. When changes of alveolar crest height were compared, between adolescent and adult group were not significantly. 4. When changes of alveolar crest height were compared, significantly larger changes were noticed in ex윤action than nonextraction cases. 5. When changes of alveolar crest height were compared, significantly larger changes were noticed in maxilla than mandible. 6. When mesio-distally compared, significantly larger changes were observed in the distal than mesial sides of adult group.

  • PDF

Influence of internal connection length on screw loosening in internal connection implants (내측 연결 임플란트에서 지대주 내부길이가 나사 풀림에 미치는 영향)

  • Kim, Ji-Sun;Park, Young-Bum;Choi, Hynmin;Kim, Sungtae;Kim, Hyeon Cheol;Kim, Sun Jai;Moon, Hong-Seok;Lee, Jae-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.251-257
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate whether the internal abutment length affected screw stability in an internal connection implant. Materials and methods: Twenty long internal connection implants (Replus system, $4.7{\times}11.5mm$) were selected for this investigation. Abutments were assigned to four groups depending on the length of the internal connection (abutments with internal lengths of 1, 2, 3, and 4 mm, respectively). Each implant fixture specimen was embedded in resin medium and connected to an abutment with an abutment screw. A load of 100 N, applied at an angle of $30^{\circ}$ to the long axis of the implant, was repeated for $1.0{\times}10^6$ cycles. Reverse torque values (RTV) were recorded before and after loading, and the change in RTV was calculated. Data were analyzed with the Kruskal-Wallis test. Results: The change in RTV was not significantly different among the groups (P>.05). Screw loosening and fractures were not observed in any groups, and joint stability was maintained. Conclusion: The internal length of the abutment may not significantly affect the degree of screw loosening.

Effect of different adhesive systems and post surface treatments on the push-out bond strengths of fiber-reinforced post (다양한 접착 시스템 및 포스트의 표면 처리가 섬유 강화 포스트의 접착 강도에 미치는 영향)

  • Kim, Min-Woo;Ahn, Jin-Hee;Kim, Lee-Kyoung;Shim, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.218-225
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the push-out bond strength of glass-fiber post cemented with different adhesive systems and surface treatments. Materials and methods: 160 tooth samples made from 48 human maxillary single-rooted teeth with similar root length were divided into 4 groups according to the adhesive system (no adhesive, Adper Single Bond 2, Clearfil SE Bond, Clearfil S3). Each group had 4 subgroups according to the post surface treatment methods (no treatment, sandblast, silane, sandblast and silane). Posts (Parapost Fiber White) were cemented with Rely X Unicem. The teeth were sectioned perpendicular to their long axis into 1-mm thick sections. The push-out tests was performed at a speed of 0.5 mm/min. The results were evaluated by 2-way ANOVA, 1-way ANOVA and multiple comparison procedures (Tukey test) (${\alpha}=0.05$). Results: Tukey test showed that the adhesive system significantly influenced the push-out strength. The Clearfil SE Bond group showed the highest value. Post surface treatments showed no significant effect. Conclusion: Bond strength of glass-fiber post cemented with self-adhesive resin cement using Clearfil SE Bond showed significantly higher values compared to other adhesive systems.

MR Imaging Measurement of the Femoral Anteversional Angle as a PACS Image Viewer (MR 영상에서의 PACS Image Viewer를 이용한 대퇴골 전염각 측정)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2003
  • The accurate measurement of the femoral anteversion is very important to the practice of orthopedic and osteotomy. It is measured by means of the axis of head and neck of the femur and the knee axis. At the present time, widely used computed tomography method of measuring anteversion on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In September and October 2002, 5 patients 28 to 36 years of age were randomly selected from Seoul National University Hospital. The purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing PACS image viewer program in the MR imaging. Significant difference was observed between the right and left side the image viewer measurement of femoral anteversion. In conclusion, MR imaging very usefulness in the measured the angle of the femoral anteversion.

  • PDF

Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading (새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력)

  • Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate screw removal torque of the two-piece zirconia abutment with the novel titanium component compared to the conventional one-piece titanium abutment in the internal connection implant before and after dynamic cyclic loading. Materials and methods: Two types of the abutment assemblies with internal connection were prepared and divided into the groups; titanium abutment-titanium abutment screw assemblies as control, and zirconia abutment-titanium socket-titanium abutment screw assemblies as experimental group. A total of 12 abutments and implants were used of six assemblies each group. Each assembly was tightened to 30 Ncm. A cyclic load of 300 N at an angle of 30 degrees in reference to the loading axis was applied until one million cycles or failure. The removal torque values (RTVs) of the abutment screws were measured with a digital torque gauge before and after cyclic loading. The RTVs of the pre load and post load were analyzed with t-test, and P-values < .05 were considered statistically significant. Results: The assemblies of both groups survived all after the dynamic cyclic loading test without screw loosening. The statistically significant differences were found between the mean RTVs before and after the cyclic loading in both groups (P < .05). The RTV differences for the control and the experimental group were $-7.25{\pm}1.50Ncm$ and $-7.33{\pm}0.93Ncm$, respectively. Statistical analysis revealed that the RTV differences in both groups were not significantly different from each other (P > .05). Conclusion: Within the limitation of this study, the two-piece zirconia abutment with the titanium component did not show a significant RTV difference of the abutment screw compared to the titanium abutment after dynamic cyclic loading.

Differences in percussion-type measurements of implant stability according to height of healing abutments and measurement angle (임플란트 healing abutment 높이와 타진각도에 따른 타진방식 임플란트 안정성 측정기기의 수치 차이)

  • Park, Yang-Hoon;Leesungbok, Richard;Lee, Suk-Won;Paek, Janghyun;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.278-286
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the effect of healing abutment height and measurement angle on implant stability when using Periotest and AnyCheck. Materials and methods: 60 implants were placed into artificial bone blocks. After implant insertion, 2, 3, 4 and 5 mm healing abutments were installed on 15 specimens, respectively. Insertion torque value, implant stability test, Periotest value were measured. Insertion torque value was controlled between 45 - 55 Ncm. AnyCheck was used for measuring implant stability test and Periotest M was used for measuring Periotest value. Implant stability test and Periotest value were measured at the angles of 0 and 30 degrees to the horizontal plane. Measured values were analyzed statistically. Results: Insertion torque value had no significant difference among groups. When healing abutment height was higher, implant stability test and Periotest value showed lower stability. Also when measurement angle was decreased, implant stability test and Periotest value showed lower stability. Conclusion: When measuring stability of implants with percussion type devices, measured values should be evaluated considering height of healing abutments and measurement angle.

Detection of Subsurface Ancient Remains in Sooseong Dang Area, Buan Using Ground Penetration Radar Technique (지하투과레이다 기법을 이용한 부안 수성당 지역의 지하 유적 탐사)

  • Lee, Hyoun-Jae;Jeon, Hang-Tak;Yun, Sul-Min;Hamm, Se-Yeong
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.553-563
    • /
    • 2019
  • In order to survey archaeological sites, drilling and excavation are carried out at the final stage. However, at the preliminary stage, non-excavation geophysical prospection is used for assessing underground archaeological ruins. Among the geophysical prospecting techniques, Ground Penetration Radar (GPR) prospection has effectively been applied to historical sites due to its high resolution at shallow depths. In this study, the GPR prospection was conducted to find underground ruins near Suseong-Dang, the place of ancient rituals in Buan area, Korea. First, the GPR prospection was conducted at three sites (Site-1, 2, and 3), and subsequently, the GPR prospection was carried out at Site-3 in more detail. As a result of the prospection, the underground layered structure of the survey area consists of three layers, which are soil layer, weathered rock, and sound rock from the surface. And the GPR anomaly to the archaeological structure was clearly identified at around 100-cm depth showing est-west direction that is parallel to the long-axis array. This GPR anomaly of irregular geomorphological features and intermittent distribution may be related to the ritual remains found in Suseong Dang. The GPR prospection could be effectively used to detect archaeological sites or remains buried in the ground.

The Oogenesis of Coreoleuciscus splendidus, Cyprinidae, Teleostei (경골어류 잉어과 쉬리(Coreoleuciscus splendidus)의 난자형성과정)

  • Kim, Dong-Heui;Kim, Wan-Jong;Teng, Yung-Chien;Kim, Seok;Lee, Kyu-Jae
    • Applied Microscopy
    • /
    • v.40 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • Coreoleuciscus splendidus is a teleost belonging to Gobioninae, Cyprinidae. The oogenesis was investigated by light microscope. The ovary was located between intestine and air bladder, a grayish and ellipsoidal shape with the major axis 20 mm and the minor axis 5 mm. Cytoplasm of oogonia was basophilic and many nucleoli were located at inside of nuclear membrane. In primary oocytes, yolk vesicles were distributed only in the marginal area and egg envelope was not formed on the outside of an egg. In secondary oocytes, the egg envelope was formed and yolk vesicles in the cytoplasm were increased than the earlier stage. The basophilic substance of cytoplasm was changed to acidic. In case of matured egg, thickness of egg envelope and size of egg were increased. The yolk vesicles were changed to yolk mass in accordance with development. In conclusion, the oogenesis of C. splendidus was characterized by the increase in cell size, the formation and accumulation of yolk, and the decrease of basophilic substance in the cytoplasm. The oogenesis of C. splendidus is similar with other Cyprinidae fishes. But further study on ultrastructural study of fertilized egg envelope will be necessary to get the species specificity.

The Spermatogenesis of Chinese minnow, Leuciscinae, Teleostei (경골어류 황어아과 버들치의 정자형성과정)

  • Kim, Dong-Heui;Chang, Byung-Soo;Kim, Wan-Jong;Lee, Myeong-Seon;Teng, Yung-Chien;Kim, Seok;Lee, Kyu-Jae
    • Applied Microscopy
    • /
    • v.40 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • The ultrastructure of spermatogenesis and sperm in Chinese minnow, Rhynchocypris oxycephalus belonging to Leuciscinae was investigated by light and electron microscopes. The whitish testis was located between intestine and air bladder. The size of testis was major axis 2.3 cm, minor axis 6 mm. The testis contained numerous testicular cysts, and spermatogenesis was non-synchronized in these testicular cysts. In the case of spermatogonium, the nucleus was comparatively large ellipsoidal, and mitochondria showed a marked development. The size of primary spermatocyte was smaller than that of spermatogonia, and secondary spermatocyte was smaller than primary spermatocyte. The chromatin of spermatocyte was highly condensed according to their development. The nucleus with electron-dense was round shape. In spermiogenesis, flagella started to be formed and chromatin was more condensed. The mitochondria were rearranged in a middle piece. The sperm was formed by loss of cytoplasm. The head of mature sperm was a spherical shape and have not acrosome. The microtubules of flagella were arranged 9+2 structure. Also, the tail of sperm have not lateral fins.

The effect of implant system with reverse beveled platform design on marginal bone stress distribution (임플란트 경부의 역사면 디자인이 변연골 응력분포에 미치는 영향)

  • Cha, Ji-Young;Cho, Jin-Hyun;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.266-272
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effects of the surface morphology of the implant neck on marginal bone stress measured by using finite element analysis in six implant models. Materials and methods: The submerged type rescue implant system (Dentis co., Daegu, Korea) was selected as an experimental model. The implants were divided into six groups whose implant necks were differently designed in terms of height (h, 0.4 and 1.0 mm) and width (platform width, w = 3.34 + 2b [b, 0.2, 0.3 and 0.4 mm]). Finite element models of implant/bone complex were created using an axisymmetric scheme. A load of 100 N was applied to the central node on the top of crown in parallel with the implant axis. The maximum compression stress was calculated and compared. Results: Stress concentration commonly observed around dental implants did not occur in the marginal bone around all six test implant models. Marginal bone stress varied according to the implant neck bevel which had different width and height. The stress was affected more markedly by the difference in height than in width. Conclusion: This result indicates that the implant neck bevel may play an important role in improving stress distribution in the marginal bone area.