• Title/Summary/Keyword: 장기적 사용성

Search Result 1,818, Processing Time 0.031 seconds

Long-Term Performance Evaluation of Concrete Utilizing Oyster Shell in Lieu of Fine Aggregate (굴패각을 잔골재로 대체 사용한 콘크리트의 장기성능 평가)

  • Yang, Eun-Ik;Yi, Seong-Tae;Kim, Hak-Mo;Shim, Jae-Seol
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.280-287
    • /
    • 2003
  • To evaluate the practical application of oyster shells(OS) as construction materials, an experimental study was performed. More specifically, the long-term mechanical properties and durability of concrete blended with oyster shells were investigated. Test results indicate that long-term strength of concrete blended with 10% oyster shells is almost identical to that of normal concrete. However, the long-term strength of concrete blended with 20% oyster shells is appreciably lower than that of normal concrete. Thereby, concrete with higher oyster shell blend has the possibility of negatively influencing the concrete long-term strength. Elastic modulus of concrete blended with crushed oyster shells decreases as the blending mixture rate increases. Namely, the modulus is reduced to approximately 10∼15% when oyster shells are blended up to 20% as the fine aggregate. The drying shrinkage strain increases with an increasing crushed oyster shells substitution rate. In addition, the existing model code of drying shrinkage and creep do not coincide with the test results of this study. An adequate prediction equation needs to be developed. The utilization of oyster shells as the fine aggregate in concrete has an insignificant effect on fleering and thawing resistance, carbonation and chemical attack of concrete. However, water permeability is considerably improved.

Two-Way Donation Locking for Transaction Management in Distributed Database Systems (분산환경에서 거래관리를 위한 두단계 기부 잠금규약)

  • Rhee, Hae-Kyung;Kim, Ung-Mo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.12
    • /
    • pp.3447-3455
    • /
    • 1999
  • Database correctness is guaranteed by standard transaction scheduling schemes like two-phase locking for the context of concurrent execution environment in which short-lived ones are normally mixed with long-lived ones. Traditional syntax-oriented serializability notions are considered to be not enough to handle in particular various types of transaction in terms of duration of execution. To deal with this situation, altruistic locking has attempted to reduce delay effect associated with lock release moment by use of the idea of donation. An improved form of altruism has also been deployed in extended altruistic locking in a way that scope of data to be early released is enlarged to include even data initially not intended to be donated. In this paper, we first of all investigated limitations inherent in both altruistic schemes from the perspective of alleviating starvation occasions for transactions in particular of short-lived nature. The idea of two-way donation locking(2DL) has then been experimented to see the effect of more than single donation in distributed database systems. Simulation experiments shows that 2DL outperforms the conventional two-phase locking in terms of the degree of concurrency and average transaction waiting time under the circumstances that the size of long-transaction is in between 5 and 9.

  • PDF

병원정보시스템 품질 항목에 대한 제안

  • Park, Chan-Seok;Go, Seok-Ha
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2007.05a
    • /
    • pp.300-320
    • /
    • 2007
  • 정보기술의 발달과 함께 소프트웨어 제품은 모든 산업에 필수요소가 되었고, 품질과 평가에 대한 관심도 점차 증가되고 있다. 하지만 일부 산업에서는 소프트웨어 품질 평가에 대한 사용자들의 만병 통치적 기대, 품질 표준의 부족, 측정을 위한 양질의 데이터 부족, 소프트웨어 분석과 디자인에 대한 공학적 한계로 소프트웨어 품질 평가에 대해 많은 문제점이 지적되고 있다. 국내에서도 의료산업 관련 정보시스템의 오류 및 사용자들의 운영 미숙은 매년 많은 금액의 사회적 비용을 증가시켰고, 병원정보시스템의 품질에 대한 관심을 초래하였다. 특히, 산업적 특성이 강한 병원정보시스템은 성공적 구축을 위해 사용자 중심의 소프트웨어 디자인과 다양한 전문가들의 지식 통합이 필요하며, 정보시스템 품질 측정으로 연구자들과 개발자들의 시스템 설계 혼란을 감소시키는 방법론이 필요하다는 연구들이 등장하고 있다. 대부분의 병원정보시스템이 단편적인 업무처리 위주로 개발 운영되고 있고, 장기적 경영전략이나 임상연구를 위한 분석적 정보처리 기능들은 결여되어 있다. 또한 소프트웨어 재설계나 추가적 개발 에 활용될 수 있는 객관적 품질 기준이 부족하고, 사용자들의 요구사항에 대해 소프트웨어 설계에 있어서 효율적으로 반영되지 못하고 있다. 이에 본 연구는 최근 발표된 병원정보시스템 품질 평가에 대한 연구 경향을 종합하고, 품질 평가에 대 해 효율적으로 활용되고 있는 사용성(Usability)을 기준으로 병원산업의 특수성을 포함한 품질 평가 방법과 품질척도를 제안하고자 한다. 국제표준기구(ISO:International Standards Organization)에서는 품질 특성을 기능성, 신뢰성, 사용성, 효율성, 유지 보수성과 이식성의 특성을 제시하고 있다. 특히 Folmer & Bosch(2004)가 정리한 ISO9126에서는 품질의 특성을 배움의 용이성, 운영의 용이성, 이해성과 매력성으로 분류하였고, ISO9241-11는 효과성, 효율성과 만족성으로 분류하였다. 또한 Shackel(1991)은 배움의 용이성(배움과 시간, 기억력), 효과성(오류, 직무시간), 유연성과 마음가짐으로 분류하고 있다(Shackel, 1991). Nielsen(1997)은 배움의 용이성, 기억의 용이성, 오류, 효율성, 만족성으로 분류하고 있고(Nielsen, 1997), Shneiderman(1998)는 효과성(직무시간, 배움의 시간), 효율성(기억의 지속시간, 오류), 만족도를 품질의 특성으로 분류하였다. 이와 같은 소프트웨어의 품질은 소프트웨어 계획, 개발, 성장과 쇠퇴의 모든 과정에 적용되며, 환경적 변화에 따라 사용자들의 정보욕구를 적절하게 반영하여 만족도를 높이 는 것이라고 요약할 수 있다. 그러나 현재까지 소프트웨어 품질 평가에 대한 연구들 은 보편적인 평가 항목들을 대상으로 측정하여 일반적인 품질기준을 제시하고 있고, 유사한 측정 내용들이 중복되어 있다. 이러한 경향은 산업별 특수성이 강한 소프트웨어에 대해서는 정확한 품질측정이 어려웠고, 품질측정에 대한 신뢰성을 떨어뜨리는 계기가 되었다. 이러한 한계를 극복하고자 나타난 방법론이 최종사용자들의 요구사항을 얼마나 적절하게 시스템에 반영했는지에 대한 사용성(Usability) 측정이다. 사용성에 대한 정의는 사용자들이 실질적으로 일하는 장소에서 직접 사용자들의 시스템 운용실태를 파악하여 문제점을 개선하는 것으로 요약할 수 있다. ISO9124-11에서는 사용성을 "어떤 제품이 구체적인 사용자들에 의해 구체적인 목적을 달성하기 위한 구체적인 사용의 맥락에서 효율성, 효과성을 만족함으로 사용될 수 있는 정도"로 정의하고 있다. 지난 10년간 병원정보시스템 평가에 대한 문헌들을 고찰한 결과 품질 측정의 효과는 정보화에 대한 동기유발과 의료품질을 높이는 게기가 되었으며, 질병에 대한 예방효과도 높은 것으로 조사되었다. 그러나 평가에 대한 인식의 문제, 평가 방법의 신뢰성 부족, 평가 지침과 부분적 평가에 따른 인증의 어려움 평가 결과에 대한 확산과 단편적 연구의 한계 등으로 연구결과에 대한 신뢰도와 활용도는 낮은 것으로 조사되었고, HIS에 대한 연구 빈도와 범위 가 매우 미약하였다. 특히, 품질속성은 같은 용어이지만 연구자에 따라 전혀 다른 측정 내용을 제시하고 있어 효율적인 품질 지표를 제시하는데 많은 혼란을 초래하고 있다. 이러한 품질 평가의 경향은 시스템 설계 및 개발자들에게 필요한 사용자들의 구체적이고 독특한 욕구나 병원정보시스템 환경의 특수성 파악에 한계를 보였으며, 평가 범위도 부분적으로 이루어져 전사적 시스템 설계 및 개발에 중요한 자료를 제공하지 못하고 있다. 이러한 문제점과 한계를 극복하고자 ISO와 같은 품질 표준 속성과 컨텍스트(Context)를 중심으로 사용자에 의한 평가 척도의 설정은 구체적이고 실용적이며 신뢰성 있는 평가 방법이 될 것이다.

  • PDF

A Study on the Long-Term Behavior of UHPC Pedestrian Cable Stayed Bridge (UHPC 보도사장교의 장기거동에 관한 연구)

  • Chin, Won-Jong;Kim, Young-Jin;Choi, Eun-Suk;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.109-110
    • /
    • 2010
  • A pedestrian UHPC cable-stayed bridge(Super Bridge I) of the KICT was completed as a test bed. A long-term monitoring system has been installed on the UHPC bridge in order to acquire all types of long-term data such as strain, acceleration, tension force, wind direction and speed, temperature, etc. This system will provide valuable database enabling to assess the long-term behavior of the UHPC pedestrian hybrid cable-stayed bridge. This database will be exploited for the evaluation of the mechanical characteristics and serviceability of the UHPC members so as to estimate the behavioral features of long-span hybrid cable stayed bridges.

  • PDF

Optimal Storage Condition of Clubroot Pathogen, Plasmodiophora brassicae for Artificial Inoculation (배추뿌리혹병균(Plasmodiophora brassicae)의 인공접종을 위한 효율적인 저장조건)

  • Yang, Seul Gi;Park, Ju Young;Seo, Mun Won;Kim, Hong Gi
    • The Korean Journal of Mycology
    • /
    • v.43 no.4
    • /
    • pp.286-289
    • /
    • 2015
  • Clubroot, caused by the obligate parasite Plasmodiophora brassicae, is a severe soilborne disease of Brassicaceae. Storage of clubroot gall is important for studies on pathogenicity and race identification. As the current storage method has been used for more than 100 years, a new storage method should be developed and the most efficient way maintaining pathogenicity should be determined. Effects of storage conditions with different storage periods on pathogenicity in galls of kimchi cabbage were examined in a greenhouse. The experiments were performed under six conditions and four temperatures in order to determine the most effective storage conditions for maintenance of pathogenicity. The most effective conditions for clubroot gall storage was the storage of whole gall at $-70^{\circ}C$ or storage of filtrate at the same temperature through eight layers of gauze after homogenization of the galls.

Risk of Gastrointestinal Bleeding Associated with Use of Low-dose Aspirin in Korean Children (소아에서 소용량 아스피린의 장기간 사용에 의한 위.장관 출혈 위험성에 대한 연구)

  • Bae, Sun-Hwan;Son, Dong-Woo;Park, Kyung-Hee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.1
    • /
    • pp.10-16
    • /
    • 2003
  • Purpose: To evaluate the risk of gastrointestinal bleeding associated with use of low-dose aspirin in children. Methods: Among about 250 children who received low-dose aspirin (5 mg/kg/day) under the diagnosis of Kawasaki disease, from March 1995 to May 2001, at Eul-Ji general hospital, 100 children were enrolled in this study. We reviewed the medical records and interviewed the children's parents over the phone to confirm the existence of gross gastrointestinal bleeding. Results: The age of the children at the beginning of medication ranged 4~118 months. About 75% of them was younger than 3 years old. The duration of medication ranged 0.5~17 months. About 70% of the children took the medicine for 2~3 months. Only 1 child (1%) had hematochezia during medication without any accompanying gastrointestinal symptom, and cimetidine for 1 week had cleared up the bleeding. The total duration of medication of 100 children was 341.5 months, and only 1 child had gastrointestinal bleeding. This translates into a rate of clinically significant gastrointestinal bleeding of 3.5 episodes/100 children/year. Conclusion: The long-term use of low-dose aspirin is safe, but, is associated with the risk of gastrointestinal bleeding in children. Careful follow-up and efforts to reduce the risk of gastrointestinal bleeding are necessary during long-term low-dose aspirin therapy in children.

  • PDF

Development of a Hospital Application Integrated with Healthcare Services (헬스케어 서비스를 통합한 병원 애플리케이션 개발)

  • Min Ho Jo;Sung Jin Kim;Young Hyun Yoon;Jai Soon Baek
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.269-272
    • /
    • 2023
  • 본 논문은 디지털 플랫폼과 헬스케어 서비스를 통합한 병원 애플리케이션(병원 앱)의 개발 및 활용에 초점을 맞춘다. 목표는 환자와 의료 제공자 간의 의사 소통과 효율성을 향상시키는 것이다. 이 연구는 병원 앱의 주요 기능과 이점을 탐색하고, React Native를 사용하여 기술적 측면과 디자인 원칙을 제공하고, 적절한 사용 및 보안을 위한 지침을 검토한다. 이 연구는 병원 앱의 잠재력과 장점을 평가하고 의료 서비스 효율성과 품질을 향상시키기 위한 실용적인 지침을 제공하고 있다. 병원 앱의 통합으로 환자 치료, 커뮤니케이션을 개선하고 의료 프로세스를 간소화할 수 있다. React Native와 같은 기술을 활용하여 약속 일정, 예약 확인, 의료 정보 액세스, 의료 전문가 디렉토리와 같은 기능을 구현하여 포괄적인 사용자 경험을 제공할 수 있다. 지침과 규정을 준수하는 것은 의료 데이터의 적절한 사용과 보호를 보장하는 데 필수적이다. 향후 연구에서는 인공 지능 및 원격 의료와 같은 신기술을 병원 앱에 통합하고 장기적인 영향을 평가할 수 있다. 이 분야의 지속적인 개발과 혁신은 디지털 시대에 의료 서비스를 변화시킬 잠재력을 가지고 있다.

  • PDF

Evaluation of the Mechanical Properties of Field-Cast Shotcrete and Long-Term Durability by Combined Deterioration Test (현장타설 숏크리트의 역학적 성능 평가 및 복합열화시험을 통한 장기내구성 평가)

  • Ma, Sang-Joon;Jang, Phil-Sung;Kim, Dong-Min;Choi, Jae-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.47-56
    • /
    • 2007
  • Recently, tunnels are increasingly constructed in this country with the increased construction of highways, high-speed railways and subways. Shotcrete is one of the major processes in the tunnel construction. Many problems, however, exist in the current shotcrete practice. The purpose of the study is, therefore, to explore the trobles in the current shotcreting practice, and to develop high-quality silica fume shotcrete. For the purpose of security a long-term durability of shotcrete, this study conducted combined deterioration tests. In this study, a combined deterioration test in consideration of a variety of deterioration factors were proceeded. Especially, micro-silica fume that was used frequently in overseas because of a outstanding strength-promotion effect was applied to combined deterioration test, and a long-term durability of shotcrete was investigated according to additions mixing. As a result of test, the shotcrete mixed Micro-silica fume showed a good deterioration quality compared with the other mixes. And is shows that the Micro-silica fume has an outstanding strength-promotion effect and is effective to secure a long-term durability of shotcrete by means of decreasing a deterioration caused by steel fiber mixed.

Review on Spent Nuclear Fuel Performance and Degradation Mechanisms under Long-term Dry Storage (사용후핵연료의 장기 건식 건전성 성능과 주요 열화 기구에 관한 고찰)

  • Kim, Juseong;Kook, Donghak;Sim, Jeehyung;Kim, Yongsoo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.4
    • /
    • pp.333-349
    • /
    • 2013
  • As the capacity of spent nuclear fuel storage pool at reactor sites becomes saturated in ten years, long term dry storage strategy has been recently discussed as an alternative option in Korea. In this study, we reviewed safety-criteria-related research results on spent nuclear fuel performance and integrity under long-term dry storage and proposed the direction and the scope of future domestic research and development. Creep and hydride effect in relation to the embrittlement are known to be the major degradation mechanisms of the spent fuels during the long term dry storage. However, recent research results showed that hydride reorientation and hydride embrittlement are one of the most critical factors to the spent fuel integrity. Accordingly safety criteria of US and Japan for the storage system are basically founded on those mechanisms. However, in Korea, not only in-pile but out-of-pile experimental data have not been generated to understand fuel cladding degradation and to determine the criteria to ensure the safety. In addition, the transient behavior of the spent fuel during transportation also needs to be thoroughly examined. Therefore, various experimental research and development will be required to establish our own safety criteria for future long-term dry storage of domestic spent fuels.

석고의 배수성에 관한 계통적 연구

  • 한국양회공업협회
    • Cement
    • /
    • s.61
    • /
    • pp.58-63
    • /
    • 1975
  • 1) 본연구논문은 Zement-Kalk-Gips 1975년도 8월호에 게재된 TH Chavatal씨의 $\ulcorner$Systematische Versucke zur Hydrophbierung des Gipses$\lrcorner$를 번역 발췌한 것으로 요약하면 다음과 같다. 2) 현재 사용가능한 agent 중에서 가장 효과적인 것을 선택하여 석고에 장기 배수성을 가지게 하는 것이 가능한가의 여부에 대한 실험 결과이다. 3) 원필자의 실험은 28일간 계속되었으며 $\alpha$형 및 $\beta$형 반수석고에 대해 물의 흡수, 강도변화, 체적의 감소 및 표면의 손상 등에 대해 계통적으로 실험하였다. 4) $\alpha$형 및 $\beta$형 반수석고에 대해 어떤 agent도 안전히 배수성을 가지게 할 수는 없었으며 이 두 석고의 물에 대한 저항은 거의 대동소이하였다.

  • PDF