• Title/Summary/Keyword: 장기수선

Search Result 39, Processing Time 0.028 seconds

The Replacement Plans for Aged Public Water Supply Pipes in Apartment Buildings : Especially Apartment Buildings in Bucheon (공동주택의 노후 급수관 개선방안에 관한 연구 : 부천시 공동주택을 중심으로)

  • Lee, Yong-Hwa;Heo, Yong-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.228-232
    • /
    • 2015
  • The water supply galvanized steel pipes of apartment buildings in Bucheon city constructed with building permission before 1994 have many problems such as leaks, the water containing rust, and low water pressure due to corrosion. Therefore, this study aims to find a way to renew the water supply pipes under investigation through a survey. As a result, when replacing the galvanized steel pipe with the corrosion-resistant pipe, the water supply system should also be changed from the gravity tank system to the booster pump system and the hygienic water storage tank. It is necessary to redraft the long-term repair plan including the replacement of the water supply system. Also, it is necessary to save the allowance reserve according to the modified long-term repair plan.

A Study on the Service life of the Building Components in the Apartment Housing (공동주택 구성재의 내용년수 산정방법에 관한 연구)

  • Lee Kang-Hee;Chang Jung-Hee;Chae Chang-U
    • Journal of the Korean housing association
    • /
    • v.16 no.5
    • /
    • pp.67-74
    • /
    • 2005
  • The performance of building should be deteriorated with time while the building would maintain and manage the function and performance to get a living condition. For the efficient maintenance of the building, the repair cycle would be provided and applied during the service-life time. The service-life time of the building components would be needed to determine the repair time and the repair scope. The service-life time of the building components would be calculated with the 1st repair time and the recovery rate of the performance, considering the recovery rate after repaired. In this paper, the 1st repair time would be estimated with the normal probability distribution, choice probability and 3rd quadratic function. The recovery rate of the building components assumes various level according to the research target and utility area. The results of this study are as follows ; first, most of the components of the building work would range about 30 years in the service-life time and the components of the mechanical works range from 28 years to 37 years, those of the electrical works would be about 31 years.

Maintenance Management System for Long-range Planning of Apartment Buildings (공동주택의 장기수선계획을 위한 유지관리시스템)

  • Lee, Jong-Kyoon
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.67-74
    • /
    • 2003
  • The repair and maintenance planning is the principal transaction to prevent from the degradation of apartment buildings to prolong their lives. Various building components as part of living area should be maintained properly and timely before critical defects are realized, then the building life might be extended until the limit of its usability. In other words, various building components such as utilities, finishes and structural members are needed to be repaired and replaced in different time interval after completion. To do this systematically, a maintenance management system for Long-Range Planning (LRP) needs developing. The LRP should be figured out based on the forecast of repairing and replacing cycle of building components according to work trades. And the precise forecast of repairing and replacing time of the components helps to enhance the usability of the developed system. The purpose of this paper is to suggest a system with which apartment building managers carry out the tasks of periodical check, diagnosis and replacement of building components based on the maintenance calendar. By using the system, they can easily forecast repairing and replacing time of the components with the consideration of life cycle of building materials and build the LRP.

A study on the Residential Satisfaction and Maintenance Consciousness to the Life Span of Apartment (경년에 따른 공동주택 거주자의 주거환경 만족도 및 관리의식 조사연구)

  • Yoon, Chung-Sook;Shin, Soo-Young;Kim, Soo-Jeong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.43-49
    • /
    • 2005
  • The purpose of this study was to provide the fundamental data for the gradual apartment management plan. Through the questionnaire survey, residential satisfactions and maintenance consciousness were investigated. As the result of statistic analysis, the residents' needs for improvement according to the life span of apartment communities were found out. And we can also compare the differences about maintenance consciousness to the life span of apartment. The major research findings are as follows. First, the satisfaction averages according to the life span of apartment communities were classified two groups, less than 10 years' and over than 10 years'. By the requirement for improvement according as the life span apartment communities, habitability factors was demanded in less tham 10 years' group and safety factors was required in over than 10 years' group, Second, dwellers have high preference about remodeling to reconstruction. Especially we have to pay attention to the result that positive consciousness of remodeling and long term reparative marked highly in the group which has the short elapsed years. These results represent the possibility gradual step-by-step remodeling. In other words, the object of remodeling is not only odeteriorated apartments but also new apartments to have short elapsed years.

  • PDF

A Study on the Development of Low Pass Filter for Chopper Gate Control Unit of Electric Rolling Stock (부산도시철도 1호선 전동차 Low Pass Filter 개발연구)

  • Kang, Hyun-Chul;Kim, Hae-Chang;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1445-1456
    • /
    • 2011
  • This paper presents the research of Low Pass Filter(hereinafter called "LPF") which is the part of Chopper Gate Control Unit on the electric rolling stock. Chopper Gate Control Unit controling the propulsive equipments of electric rolling stock consists of several electronic parts, PCB, Power Supply, Gate Circuit Amp, Freon Cooling Device, and has been used the parts made by japan manufacturer Mitsubish. But these parts recently have been more broken down and slow down performance because of long-term use, deterioration. Most of the malfunctions are low performance of LPF. Furthermore, it is physically impossible to repair LPF. Because it is molding type part and no longer manufactured. Also it needs high cost for custom-building. Therefore, it is now making up for through self-developed LPF and operating on Busan metro 1st after on-board testing. This research performed the PS Pice simulation testing, analysis of self-developed LPF performance and the wave form characteristic by multi-function synthesizer, spectrum analyzer, oscilloscope.

  • PDF

Improvement of Elevator Management System after Completion (준공 이후 승강기 관리체계 개선에 관한 연구)

  • Cho, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.455-461
    • /
    • 2016
  • To operate a large structure or a high-rise building, elevator is essential. Nevertheless, elevator breakdowns or accidents have been consistently reported. When the accidents are not serious, the records are not reported and cumulated in the Korea Elevator Safety Agency. Additionally, in case of replacement or repair of the parts of elevator, conflicts about the person responsible for the expense of the replacement or repair are frequently occurred. However the record of accidents is not decreasing and the conflict about the fund of elevator repair is serious. So, it is needed to reduce the elevator accidents or malfunction, the operation stop of the elevator, the conflict between building owners and users. Therefore, in this study, the elevator maintenance procedures during defect liability period, the notification procedure in case of breakdown or accident elevator, the direction of elevator maintenance contracts, the direction of the elevator inspection were suggested.

The Comparison of Apartment Management System Between Korea and Japan (한국과 일본의 공동주택 관리제도 비교)

  • Kang, Hye-Kyoung
    • Journal of Family Resource Management and Policy Review
    • /
    • v.10 no.3
    • /
    • pp.45-62
    • /
    • 2006
  • This research is carried out to inspect the Apartment Management System of Japan, to examine the similarities and differences between the Korean Apartment Management System and the Japanese Apartment Management System. First, as the basis law of apartment management, there exists the Building Unit Ownership Act, the Promotion Law fur Adequate Mansion Management of Japan, the Housing Law, Housing Execution Law and Rule of Korea. Second, the Association of Apartment Owners, an organization of owners of apartments in Japan and the Commission of the Representatives of the Occupants in Korea become the subject of maintenance. The Japan structure is made of the Assembly, the Director and the President. The Korean structure is made of Regular and Temporary Conferences and elected Officers(1 president, at least 2 directors and at least 1 inspector). The Commission of the Representatives of the Occupants and the Organization of Owners of Apartments make bylaws and diverse maintenance rules. Third, the foremost reason why the Korean structure of maintenance of apartments is less efficient than Japan is because of the small number of people dispatched to the living-environment maintenance team and their short terms. It is necessary to grow professionals related to this sector and to have enough public servants that specialize in this. Fourth, although it is compulsory to make long term plans for maintenance based on the Housing Law, because the reserve fund is decided by the maintenance rule(with no compulsory standards of reservation) of each apartment, it is difficult to reserve an adequate amount of reserve fund. So as in the example of the state of Hawaii in America, based on long term plans for maintenance, an execution rule of the Housing Law should be made which enforces to reserve at least 50 percent of future maintenance expenses.

  • PDF

Development of Dry Process Caisson Method for Maintenance of Submerged Harbor Structure (수중 항만구조물의 유지보수를 위한 건식 케이슨 공법 개발)

  • Lee Joong-Woo;Oh Dong-Hoon;Kwak Seung-Kyu;Kim Sung-Tae
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.163-170
    • /
    • 2006
  • Together with the trend of enhancement in domestic industrial development and economic progress due to import and export, the demand for construction of the roads, bridges, especially port facilities, and several coastal protection and ocean structures is increasing rapidly. MOMAF of Korean Government is driving construction of 9 new ports and renovation of the existing fishery ports. Among these structures most of bridge base, wharves, dolphins, quays, and jetties are being newly built of steel or concrete pile. As the base, supporting bulkheads, and piles are underwater after construction, it is difficult to figure out the status of structures and not enough to get maintenance and strengthen the structures. Every year, moreover, these works suck the government budget due to higher incomplete maintenance expense for protection from corrosions of structures and increased underwater construction period. For the purpose of cutting down the expense of government budget, it is necessary to extend the life cycle of the existing structures. Therefore, we developed a new method for maintenance of submerged structures near the waterline by allowing dry work environment with the floating caisson. The method shows easy to move around the working area and handle. It also showed not only a significant reduction maintenance expenses and time for anti-corrosion work but also better protection. This will be a milestone to reduce the maintenance and construction expenses for the shore and water structures.

  • PDF

Pelvic MRI Application to the Dosimetric Analysis in Brachytherapy of Uterine Cervix Carcinoma (자궁경부암의 강내조사치료에 있어서 흠수선량평가시 골반강 자기공명사진의 응용)

  • Chung, Woong-Ki;Nah, Byung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.57-64
    • /
    • 1997
  • Purpose : Before we report the results of curative radiotherapy in cervix cancer patients, we review the significance and safety of our dose specification methods in the brachytherapy system to have the insight of the potential Predictive value of doses at specified points. Matersials and Methods : We analyze the 리5 cases of cervix cancer patients treated with intracavitary brachytherapy in the lateral simulation film we draw the isodose curve and observe the absorbed dose rate of point A, the reference point of bladder(SBD) and rectum(SRD). In the sagittal view of Pelvic MRI film we demarcate the tumor volume(TV) and determine whether the prescription dose curve of point A covers the tumor volume adequately by drawing the isodose curve as correctly as possible. Also we estimate the maximum Point dose of bladder(MBD) and rectum(MRD) and calculate the inclusion area where the absorbed dose rate is higher than that of point A in the bladder(HBV) and rectum(HRV), respectively. Results : Of forty-five cases, the isodose curve of point A seems to cover tumor volume optimally in only 24(53%). The optimal tumor coverage seems to be associated not with the stage of the disease but with the tumor volume. There is no statistically significant association between SBD/SRD and MBD/MRD, respectively. SRD has statistically marginally significant association with HRV, while TV has statistically significant association with HBV and HRV. Conclusion : Our current treatment calculation methods seem to have the defect in the aspects of the nonoptimal coverage of the bulky tumor and the inappropriate estimation of bladder dose. We therefore need to modify the applicator geometry to optimize the dose distribution at the position of lower tandem source. Also it appears that the position of the bladder in relation to the applicators needs to be defined individually to define 'hot spots'.

  • PDF