• Title/Summary/Keyword: 장기변형

Search Result 395, Processing Time 0.031 seconds

Comparison of Conventional Thoracoscopic Wedge Resection and Modified Transaxillary Minithoracotomy with Thoracoscopy for the Treatment of Primary Spontaneous Pneumothorax (원발성 자연 공기가슴증 환자에서 고식적인 흉강경하 쐐기절제술과 흉강경을 이용한 변형된 소절개술식의 비교)

  • Lee Mi Kyoung;Ryu Dae Woong;Lee Sam Youn;Choi Jong Bum;Choi Soon Ho
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.371-376
    • /
    • 2005
  • Background: Retrospective study was carried out on patients with primary spontaneous pneumothorax with the aim of determining if conventional thoracoscopic wedge resection is superior to modified transaxillary minithoracotomy with thoracoscopy in the surgical treatment. Material and Method: 160 patients, aged 14 to 35 years with primary spontaneous pneumothorax were involved in this study. Patients were assigned to two groups by surgical technique; Conventional thoracoscopic wedge resection (group A; n=80) and modified transaxillary minithoracotomy with thoracoscopy (group B; n=80). Apical pleural abrasion & talc poudrage were performed in all cases. This study evaluated the following factors: duration of operation, days of analgesics used after operation, number of no air leak on the first postoperative day, duration of indwelling chest tube, hospital stay, postoperative complications, chronic chest pain (during follow-up) and resumption of normal activity. Relapses (ipsilateral recurrence after discharge) during follow-up periods were evaluated. Result: No significant differences were found in any of the factors studied in either group. Conclusion: Conventional thoracoscopic wedge resection and modified transaxillary minithoracotomy with thoracoscopy offer similar results in the surgical treatment of primary spontaneous pneumothorax. The rate of complication is low and the level of pain is acceptable without long-term sequele. Therefore, modified transaxillary minithoracotomy with thoracoscopy method appears as a valuable alternative surgical technique.

LTPP-SPS : Evaluation of Structural Capacity on Asphalt Pavement Reinforced with Glass Fiber (LTPP-SPS : 섬유보강 아스팔트 포장의 구조적 성능 평가)

  • Jeon, Sung-Il;Kim, Boo-Il;Kim, Jo-Sun;Lim, Kwang-Soo
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.281-292
    • /
    • 2008
  • In Korea-LTPP(Long Tenn Pavement Performance) project, the full depth asphalt pavement test sections are constructed on the national highway to evaluate the structural capacity of asphalt pavement reinforced with glass fiber. Truck loading test and FWD test were performed to measure the structural capacity of test sections. Test results showed that the reinforcement of glass fiber installed at between surface and intermediate asphalt layer decreased the strain at the bottom of surface layer and moved up the stress neutral axis in asphalt layer. As a result, the tensile stress was developed at the bottom of intermediate asphalt layer of reinforced asphalt pavement, while the compressive stress was developed at the bottom of intermediate asphalt layer of unreinforced asphalt pavement. On the other hand, the tensile strain at the bottom of asphalt base layer didn't show a difference between glass fiber reinforced and unreinforced pavements. From the FWD test, it was shown that the surface deflection of asphalt pavement reinforced with glass fiber decreased 24 percents comparing to that of unreinforced asphalt pavement. This shows that the reinforcement with glass fiber appears to improve the rutting resistance of asphalt pavement.

  • PDF

The Influence Factors on the Compensation of Column Shortening in Tall Buildings (초고층 건물의 Column Shortening보정에 미치는 영향요소)

  • Mun, Il-Won;Choi, Ki-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.208-215
    • /
    • 2018
  • The causes of column shrinkage and the codes that have been studied up to now are discussed. The documents mentioned in the code deal with the drying shrinkage, creep, compressive strength and elastic modulus of the specimen, and the elastic deformation calculated from the structural analysis. However, the deformation due to the temperature caused by the long term monitoring is less than that caused by the factors generated by the previous studies. In the previous studies, it was found that dehydration shrinkage, creep, and elastic deformation were not considered for temperature-induced deformation, while for the specimen experiments, the temperature-related items were replaced with the humidity-related terms The compensation value by the proposed equation showed error of 4.9 mm in the upper direction and 1.0mm in the lower direction when calculating column shortening, and it was found that its value by the proposed equation almost coincided with the measurement value in Site. Therefore, it is necessary to further study the temperature that can be omitted in calculating the existing column shortening, to consider the influence factors, and to supplement the criteria for the temperature measurement of the structure as well as the specimen tests.

Mechanical Fatigue Lifetime of Metal Electrode for Flexible Electronics under High Temperature and High Humidity Condition (유연 전자 소자용 금속 전극의 고온/고습 조건에서 기계적 피로 수명 연구)

  • Kown, Yong-Wook;Kim, Byoung-Joon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.45-51
    • /
    • 2020
  • As flexible electronics will be used under high temperature and high humidity with repeated bending deformations, the effects of environmental condition and repeated mechanical deformations are considered simultaneously to achieve long-term reliability. In this study, the mechanical reliability of metal electrodes (Al, Ag, Cu) deposited on flexible polymer substrate is investigated under 4 different conditions: with and without repeated mechanical deformations and normal environmental or high temperature and high humidity conditions (85℃/85%). The mechanical failure does not occur in all the metal electrodes without mechanical deformation even under high temperature and high humidity conditions. The electrical resistance of metal electrode increased about 400% to 600% after 100,000 bending cycles under normal condition. For high temperature and high humidity condition, the electrical resistance of Al and Ag increased similarly. However, the resistance of Cu during bending fatigue test under high temperature and high humidity condition increased over 90000% because of the combined effect of corrosion and mechanical fatigue. This study can give a helpful information for designing electrode materials with high mechanical reliability under high temperature and high humidity.

A Study on the D-InSAR Method for Micro-deformation Monitoring in Railway Facilities (철도시설물 미소변형 모니터링을 위한 D-InSAR 기법 연구)

  • Kim, Byung-Kyu;Lee, Changgil;Kim, Winter;Yoo, Mintaek;Lee, Ilhwa
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.43-54
    • /
    • 2022
  • The settlement at the railroad foundation is often the leading cause of track irregularity and potential derailment. The control of such deformation is considered necessary in track maintenance practice. Nevertheless, the monitoring process performed by in situ surveying requires an excessive amount of manpower and cost. The InSAR, a remote sensing technique by RADAR satellite, is used to overcome such a burden. The PS-InSAR technique is preferred for a long-term precise monitoring method. However, this study aims to obtain relatively brief analysis results from only two satellite images using the D-InSAR technique, while a minimum of 25 images are required for PS-InSAR. This study verifies the precision of D-InSAR within a few millimeters by inspecting railroad facilities and land settlements in Korea Railroad Research Institute's test track with images from TerraSAR-X Satellite. Multiple corner reflectors were adopted and installed on an embankment and the building roof to raise the surface reflectivity. Those reflectors were slightly adjusted periodically to verify the detecting performance. The results revealed the optimum distance between corner reflectors. Further, the deformation of railway tracks, slopes, and concrete structures was analyzed successively. In conclusion, this study indicates that the D-InSAR technique effectively monitors the short-term deformation of a broad area such as railway structures.

Strain Characteristics of Reinforcing materials in the transition zone of slopes (사면의 변이영역에서 보강재의 변형률 특성)

  • 김경태;장대수;장기태;한희수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.06a
    • /
    • pp.119-127
    • /
    • 2003
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are‘active zone’and‘passive zone’. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

A Study on the Reliability Improvement of oil cooler for precision Machine Tools (정밀공작기계용 오일쿨러의 신뢰성 개선 연구)

  • Lee, Seung-Woo;Lee, Hwa-Ki
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.3
    • /
    • pp.49-54
    • /
    • 2007
  • 신뢰성이란 단기간에 측정되는 성능과는 다른 지표로서 흔히 장기간에 걸쳐 평가되는 품질의 척도이다. Oil Cooler는 공작기계(machine tools)의 주축 및 구동부 등에서 발생하는 열 변형을 제어하는 장치로서 공작기계의 신뢰성 향상을 위해서는 oil cooler의 신뢰성 개선이 이루어져야 한다. 본 연구에서는 oil cooler의 신뢰성 개선을 위해 고장률 데이터베이스를 이용한 신뢰성 예측과 이를 통한 취약부품 분석을 실시하고 신뢰성 시험기를 통한 oil cooler의 신뢰성을 평가하였다. 이를 통해 oil cooler의 정량적 신뢰도를 계산하였으며 신뢰성호 향상을 위한 공정기법을 개발하여 적용하였다. Oil cooler의 신뢰성 개선을 통해 공작기계 및 반도체 제조 장비 등과 같은 제조 시스템의 신뢰성 향상을 기대할 수 있으며, 제안된 기법을 이용하여 다른 기계류 부품의 신뢰성 평가 및 개선에 적용할 수 있다.

Sedimentation & Consolidation Behaviour of Dredged Clay Fill (준설매립 점토지반의 침강 . 압밀거동)

  • 이승원;지성현;유석준;이영남
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.4
    • /
    • pp.149-156
    • /
    • 2000
  • Sedimentation and self-weight consolidation tests in cylinder and large model tank and field measurement such as settlement and pore water pressure at each layer by wireless automatic instrumentation system were carried out to investigate the behaviour of dredged marine clay fill. The consolidation behaviour for each reclaimed layer was analyzed from these measured data and numerical analysis result using finite strain consolidation theory. It was fond from this study that the consolidation behaviour of dredged clay fill is heavily dependent on the filling process.

  • PDF

Failure Zone Estimation from the correlation between the Temperature in Slope and the Soil Nail Strain (지중온도와 변형율과의 상관관계를 통한 활동영역의 추정)

  • Chang, Ki-Tae
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.3
    • /
    • pp.123-130
    • /
    • 2005
  • It is necessary, in the light of the importance of long-term slope stability problem, to develop a simple method or tool which can figure out the possible failure zone resulted from weathering effect and other factors. The FBG sensor system is used to estimate the correlations between the temperature and the slope in Kimhae, and to find a failure zone in slopes effectively. This research is to seek for the correlation between the soil temperature distribution and the strain distribution in a active zone by analyzing the data from the in-situ measurement so that the possible failure zone should be well defined based on the correlation. For instance, the zone of high temperature fluctuation can be regarded as one of the possible sliding zone due to the weathering effect while the constant temperature depth of the ground, if exists would not be relatively affected by the weathering process.

  • PDF

Strain Distribution of transition zone in a nailed wall (네일로 보강된 구조물에서의 변이영역과 변형률 분포)

  • 장기태;남궁한;유병선;김경태;권병근;이선경
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11b
    • /
    • pp.235-239
    • /
    • 2000
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are 'active zone' and 'passive zone'. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF