• Title/Summary/Keyword: 잡음 강도

Search Result 305, Processing Time 0.029 seconds

The Effect of Mean Brightness and Contrast of Digital Image on Detection of Watermark Noise (워터 마크 잡음 탐지에 미치는 디지털 영상의 밝기와 대비의 효과)

  • Kham Keetaek;Moon Ho-Seok;Yoo Hun-Woo;Chung Chan-Sup
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.4
    • /
    • pp.305-322
    • /
    • 2005
  • Watermarking is a widely employed method tn protecting copyright of a digital image, the owner's unique image is embedded into the original image. Strengthened level of watermark insertion would help enhance its resilience in the process of extraction even from various distortions of transformation on the image size or resolution. However, its level, at the same time, should be moderated enough not to reach human visibility. Finding a balance between these two is crucial in watermarking. For the algorithm for watermarking, the predefined strength of a watermark, computed from the physical difference between the original and embedded images, is applied to all images uniformal. The mean brightness or contrast of the surrounding images, other than the absolute brightness of an object, could affect human sensitivity for object detection. In the present study, we examined whether the detectability for watermark noise might be attired by image statistics: mean brightness and contrast of the image. As the first step to examine their effect, we made rune fundamental images with varied brightness and control of the original image. For each fundamental image, detectability for watermark noise was measured. The results showed that the strength ot watermark node for detection increased as tile brightness and contrast of the fundamental image were increased. We have fitted the data to a regression line which can be used to estimate the strength of watermark of a given image with a certain brightness and contrast. Although we need to take other required factors into consideration in directly applying this formula to actual watermarking algorithm, an adaptive watermarking algorithm could be built on this formula with image statistics, such as brightness and contrast.

  • PDF

Bit Error Bounds for Trellis Coded Asymmetric 8PSK in Rain Fading Channel (강우 페이딩 채널에서 비대칭 8PSK 트랠리스 부호화방식의 비트에러 상한 유도)

  • 황성현;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5B
    • /
    • pp.797-808
    • /
    • 2000
  • This paper presents the bit error rate(BER) upper bounds for trellis coded asymmetric 8PSK(TC-A8PSK) system using the Ka-band satellite in the rain fading environment. The probability density function(PDF) for the rain fading random variable can be theoretically derived by assuming that the rain attenuation can be approximated to a long-normal distribution and the rain fading parameters are calculated by using the rain precipitation data from the Crane global model. Furthermore, we analyze the BER upper bounds of TC-A8PSK system according to the number of states in the trellis diagram and the availability of channel state information(CSI). In the past, Divsalar and Simon[9] has analyzed the BER upper bounds of 2-state TCM system in Rician fading channels however this paper is the first to analyze the BER upper bounds of TCM system in the rain fading channels. Finally, we summarize the dominant six factors which are closely related to the BER upper bounds of TC-A8PSK satellite system in the rain fading channel as follows: 1) frequency band, 2) rain intensity, 3) elevation angle, 4) signal to noise ratio, 5) asymmetric angle, and 6) availability of CSI.

  • PDF

Improvement of Signal to Noise Ratio by Synthetic Aperture Focusing Technique in Ultrasonic Testing (집속 신호 합성 기법에 의한 초음파 탐상 신호 개선)

  • Lee, S.L.;Chang, K.O.;Kim, B.C.;Kim, G.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 1998
  • Nondestructive method can include both testing itself and analysis or evaluation of the testing results. Although vast amount of testing can be accomplished in a fairly short amount of time due to the advancement of electronic technology. it is really difficult matter to identify whether the indication found during testing corresponds to be a real defect. Thus, in ultrasonic testing, advanced digital signal processing techniques have been widely studied in order to identify the shape of the defect during testing, and one of the signal processing techniques, synthetic aperture focusing technique(SAFT) was tried for holes machined in carbon steel plate in this study. Result showed that signal to noise ratio has been improved considerably compared to the result from original RF signals.

  • PDF

Material Noise Reduction in Ultrasonic Test Using Polarity Thresholding Algorithm (초음파탐상 수행시 Polarity Thresholding 알고리즘을 이용한 재료잡음 억제)

  • Koo, Kil-Mo;Ko, Dae-Sik;Kim, Tae-Hyoun;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • In this paper, Polarity Thresholding(PT) algorithm has been studied to enhance the received signal in ultrasonic inspection of the stainless-steel(SUS 304) which is the primary piping material of a nuclear power plant. The spectral decomposition components obtained by splitting the spectrum of received signals are composed of dispersive signal of the interference pattern produced by the grain boundaries and nondispersive signal by the flaw. PT algorithm enhance the SNR of received signal by using above properties. In experiment the stainless-steel has been chosen as the sample and heat-treated at 1125, 1150, 1175, and $1200^\circ{C}$, respectively. And the flat-bottom hole type defects have been made artificially in samples. The pulse-echo signals from the sample by using ultrasonic transducer of center frequency 5 MHz have been processed by PT algorithm. It has been shown that PT algorithm enhanced the SNR by average 14.2 dB.

  • PDF

Implementation of Real-time Sound-location Tracking Method using TDoA for Smart Lecture System (스마트 강의 시스템을 위한 시간차 검출 방식의 실시간 음원 추적 기법 구현)

  • Kang, Minsoo;Oh, Woojin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.4
    • /
    • pp.708-717
    • /
    • 2017
  • Tracking of sound-location is widely used in various area such as intelligent CCTV, video conference and voice commander. In this paper we introduce the real-time sound-location tracking method for smart lecture system using TDoA(Time Difference of Arrival) with orthogonal microphone array on the ceiling. Through discussion on some models of TDoA detection, cross correlation method using linear microphone array is proposed. Orthogonal array with 5 microphone could detect omni direction of sound-location. For real-time detection we adopt the threshold of received energy for eliminating no-voice interval, signed cross correlation for reducing computational complexity. The detected azimuth angles are processed using median filter for lowering the angle deviation. The proposed system is implemented with high performance MCU of TMS320F379D and MEMs microphone module and shows the accuracy of 0.5 and 6.5 in degree for white noise and lectured voice, respectively.

Fabrication of PDMS microlens for optical detection (광학적 검출을 위한 PDMS 마이크로렌즈의 제작)

  • Park, Se-Wan;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.15-20
    • /
    • 2009
  • In a detection system based on laser light scattering, focusing an excitation laser beam into a focal point of a channel in a microfluidic chip is important for obtaining the highest excitation intensity, and consequently for obtaining a laser light scattering signal using a photodetector with a high efficiency. In this paper, we present a polydimethylsiloxane (PDMS) microfluidic chip consisting of an integrated PDMS microlens for cell detection based on laser light scattering. We fabricated PDMS microlens for optical detection system by simply putting down on PDMS chips. The PDMS microlens was fabricated by photoresist reflow and replica molding. This fabrication technique is simple and has an excellent property in terms of the microlens and a high-dimensional accuracy. The PDMS microlens integrated on the PDMS microfluidic chip has been verified to improve the laser intensity, and accordingly, the signal-to-noise ratio and sensitivity of laser light scattering detection for red blood cells(RBCs)

A Study on the Optical Receiver System for Digital Transmission System (디지털 전송 시스템을 위한 광 수신시스템에 관한 연구)

  • Kim, Sun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4462-4466
    • /
    • 2013
  • In optical system, the signal and additive noise for statistical properties of a variety of ways to evaluate the performance of the system is essential for the optimization. In this paper, performance analysis of spectrum-sliced optical system in the optical pre-amplifier in the receiver the received signal by including the error limits for the bit that is, the bit error rate (BER: Bit Error Rate) required to maintain the average optical power represents the number of photons per bit is included in this paper to digital form, noticeable signal the receiver to calculate the sensitivity of the method for the calculation was performed. The general strength of the transmission of the modulated signal and digital signal transmission was required for the comparison of optical power. As shown in Figure 3, the general strength of the digital signal transmission system for transmitting a modulated signal compared with the case is improved by at least 10dB.

Optimization of Resistance Spot Weld Condition for Single Lap Joint of Hot Stamped 22MnB5 by Taking Heating Temperature and Heating Time into Consideration (핫스템핑 공정에서 가열온도 및 유지시간을 고려한 22MnB5의 단일겹치기 저항 점용접 조건 최적화)

  • Choi, Hong-Seok;Kim, Byung-Min;Park, Geun-Hwan;Lim, Woo-Seung;Lee, Sun-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1367-1375
    • /
    • 2010
  • In this study, optimization of the process parameters of the resistance spot welding of a sheet of aluminum-coated boron alloyed steel, 22MnB5, used in hot stamping has been performed by a Taguchi method to increase the strength of the weld joint. The process parameters selected were current, electrode force, and weld time. The heating temperature and heating time of 22MnB5 are considered to be noise factors. It was known that the variation in the thickness of the intermetallic compound layer between the aluminum-coated layer and the substrate, which influences on the formation of nugget, was generated due to the difference of diffusion reaction according to heating conditions. From the results of spot weld experiment, the optimum weld condition was determined to be when the current, electrode force, and weld time were 8kA, 4kN, and 18 cycles, respectively. The result of a test performed to verify the optimized weld condition showed that the tensile strength of the weld joint was over 32kN, which is considerably higher than the required strength, i.e., 23kN.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Correspondence between Temporomandibular Disorder Symptoms and Clinical Examination Findings (측두하악장애 환자에서 주관적 증상과 임상검사 소견 간의 일치성)

  • Im, Yeong-Gwan;Baek, Hey-Sung;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.1
    • /
    • pp.83-91
    • /
    • 2010
  • Objectives: This study aimed to assess the characteristics of temporomandibular disorder (TMD) symptoms and to determine the correspondence between TMD symptoms and clinical examination findings. Material and methods: A total of 218 patients (143 females and 75 males; age=$31.3{\pm}14.0$) were enrolled in this study who completed a questionnaire and underwent a clinical examination and radiographic assessment. Patients were asked about all the symptoms and complaints, including onset or duration, and locations of the symptoms. Clinical examination included amounts of mouth opening, palpable temporomandibular joint (TMJ) sounds, and tenderness to palpation of the TMJ and all masticatory muscles. Tenderness scores obtained from palpation of the masticatory system were summated to define the variables for further analysis. Results: Pain was the most frequently reported symptom (78.9%), followed by joint sounds (45.4%), and limitation in mouth opening (17.0%). Jaw pain comprised 91.9% of pain complaints. The subjective intensity of jaw pain was low to medium in most patients (93.7%), but it was poorly correlated with the sum of tenderness scores of the TMJ and masticatory muscles (Kendall tau = 0.084). In contrast, the side in which pain was reported by patients was well associated with the clinical examination results (pain of the right side, p < 0.001, and left side, p < 0.001). There was moderate agreement in TMJ sounds between the side identified by patients as symptomatic and clinical examination findings (kappa = 0.482). Finally, patients who complained of restricted mouth opening showed about a 10 mm less opening in all three measurements, compared to other patients (p < 0.001). Conclusion: The most frequent symptoms reported by TMD patients were jaw pain, TMJ sounds, and mouth opening limitation. The side of jaw pain, the side of TMJ sounds, and the presence of opening limitation were highly concordant between symptom reports and examination findings.