• Title/Summary/Keyword: 잔류오염

Search Result 491, Processing Time 0.024 seconds

Contaminant Mechanism and Management of Tracksite of Pterosaurs, Birds, and Dinosaurs in Chungmugong-dong, Jinju, Korea (천연기념물 진주 충무공동 익룡·새·공룡발자국 화석산지의 오염물 형성 메커니즘과 관리방안)

  • Myoungju Choie;Sangho Won;Tea Jong Lee;Seong-Joo Lee;Dal-Yong Kong;Myeong Seong Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.715-728
    • /
    • 2023
  • Tracksite of pterosaurs, birds, and dinosaurs in Chungmugong-dong in Jinju was designated as a natural monument in 2011 and is known as the world's largest in terms of the number and density of pterosaur footprints. This site has been managed by installing protection buildings to conserve in 2018. About 17% of the footprints of pterosaur, theropod, and ornithopod in this site under management in the 2nd protection building are of great academic value, but observation of footprints has difficulties due to continuous physical and chemical damage. In particular, the accumulation of milk-white contaminants is formed by the gypsum and air pollutant complex. Gypsum remains evaporated with a plate or columnar shape in the process of water circulation around the 2nd protection building, and the dust is from through the inflow of the gallery windows. The aqueous solution of gypsum, consisting of calcium from the lower bed and sulfur from grass growth, is catchmented into the groundwater from the area behind the protection building. Pollen and a few minerals other constituents of contaminants, go through the gallery window, which makes it difficult to expel dust. To conserve the fossil-bearing beds from two contaminants of different origins, controlling the water and atmospheric circulation of the 2nd protection building and removing the contaminants continuously is necessary. When cleaning contaminants, the steam cleaning method is sufficiently effective for powder-shaped milk-white contaminants. The fossil-bearing bed consists of dark gray shale with high laser absorption power; the laser cleaning method accompanies physical loss to fossils and sedimentary structures; therefore, avoiding it as much as possible is desirable.

Seasonal Variation and Storage Period of Rainwater Quality in Changwon (창원지역 빗물의 계절변화 및 저류시간에 따른 수질변화)

  • Han, Chi-Bok;Lee, Taek-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.461-468
    • /
    • 2010
  • This study investigated variation of rainwater quality by seasonal and storage duration of rainwater in Changwon city. Seasonally, the pollutants concentration of rainwater were higher in spring and winter. In the case of rainwater and storage rainwater quality, pH of rainwater was 4.3, storage rainwaters were 6.0 and Turbidity increased about 8 times from 1.82 NTU to 14.61 NTU. The changes of storage water quality during the storage period, initial KMnO4 consumption rainwater was exceeded drinking water standard. Total solid in rainwater was detected as 116 mg/L, it tended to stable at around 70∼80mg/L after storage period for a 6day.

Development Trend of Biosensors for Antimicrobial Drugs in Water Environment (물 환경 내 항생제 약물 분석을 위한 바이오센서 개발 연구 동향)

  • Goh, Eunseo;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.27 no.6
    • /
    • pp.565-572
    • /
    • 2016
  • While there have been great demands on improving domestic water pollution issues, the necessity for real time monitoring of particular drug residues in water resources has been raised since drug residues including antibiotics could provoke new trains of drug-resistant bacteria in water environments. Among many different types of drugs used for pharmaceutical treatment, antibiotics are considered to be one of the most hazardous to our ecosystem since they can rapidly promote the spreading of drug-resistant bacteria in water environments. In this mini-review, we will highlight recent developments made on creating in-situ sensing platforms for the fast monitoring of antibiotic residues in aquatic environmental samples focusing on optical and electrochemical techniques. Related recent technology developments and the resulting economy effects will also be discussed.

Effect of residual metal salt on reverse osmosis membrane by coagulation-UF pretreatment process (응집-UF 전처리 공정에 의한 잔류 금속염이 역삼투막에 미치는 영향)

  • Go, Gilhyun;Kim, Suhyun;Kang, Limseok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.413-420
    • /
    • 2019
  • Pretreatment system of desalination process using seawater reverse osmosis(SWRO) membrane is the most critical step in order to prevent membrane fouling. One of the methods is coagulation-UF membrane process. Coagulation-UF membrane systems have been shown to be very efficient in removing turbidity and non-soluble and colloidal organics contained in the source water for SWRO pretreatment. Ferric salt coagulants are commonly applied in coagulation-UF process for pretreatment of SWRO process. But aluminum salts have not been applied in coagulation-UF pretreatment of SWRO process due to the SWRO membrane fouling by residual aluminum. This study was carried out to see the effect of residual matal salt on SWRO membrane followed by coagulation-UF pretreatment process. Experimental results showed that increased residual aluminum salts by coagulation-UF pretreatment process by using alum lead to the decreased SWRO membrane salt rejection and flux. As the salt rejection and flux of SWRO membrane decreased, the concentration of silica and residual aluminum decreased. However, when adjusting coagulation pH for coagulation-UF pretreatment process, the residual aluminum salt concentration was decreased and SWRO membrane flux was increased.

이동식 진공 배기장치를 이용한 하나로 냉중성자원 가스블랭킷계통의 기능시험

  • Jeong, Chang-Yong;Lee, Su-Cheol;Park, Guk-Nam;U, Sang-Ik;Kim, Yeong-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.330-330
    • /
    • 2010
  • 하나로 노심에서 발생하는 열중성자를 감속재인 액체수소층을 통과시켜 냉중성자를 생산 하는 설비인 냉중성자원 시설은 초경량 합금, 신소재 및 DNA 구조연구 등의 첨단기술연구에 유용한 도구로 활용될 계획이며, 현재 원자력연구원에서는 냉중성자원 시설을 개발하여 제작 설치하였고, 이 장치들에 대해 기능시험을 수행하였다. 냉중성자원 시설계통에서 가스블랭킷계통은 수소의 외부누출을 방지하고, 진공용기를 포함한 수조내기기 내부로 공기 및 경수가 유입되지 않도록 하여 냉중성자원을 보호하기 위한 역할을 수행한다. 또한 가스블랭킷계통의 구성은 가스공급장치($N_2$ 및 He 가스 실린더로부터 가스공급 기능), 질소충압탱크, 진공박스, 수소박스, 밸브박스 및 각 구역별 독립 배관 등으로 되어있다. 이동식 진공배기장치는 가스블랭킷계통에서 사용하기 위해 특수하게 제작된 장치로서 진공계통과 수소계통의 초기충진 시 또는 계통배기 시 잔류가스를 제거하거나, 블랭킷가스의 오염검사를 위한 시료채취 기능 등을 수행할 수 있도록 되어있다. 본 논문에서는 냉중성자원장치 내의 수소계통 및 진공계통의 배관과 기기를 외기와 경수로부터 안전하게 격리시키기 위해서 제작설치 적용된 가스블랭킷계통에서 이동식 진공배기장치를 이용하여 잔류가스 제거방법과 각 가스블랭킷 영역으로부터 시료를 채취하여 수행된 산소농도 분석에 대해 기술하였다.

  • PDF

Hot Air Injection/Extraction Method for the Removal of Semi-Volatile Organic Contaminants from Soils (토양내 저휘발성 유류오염물 제거를 위한 고온공기 주입/추출기술 연구)

  • Gu Chung-Wan;Ko Seok-Oh
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.1
    • /
    • pp.6-12
    • /
    • 2005
  • Contamination of soils and groundwater by leakage of petroleum compounds from underground storage tanks (USTs) has become great environmental issues. Conventional methods such as soil vapor extraction (SVE) used for the remediation of unsaturated soils contaminated with volatile organic compounds might not be applied for the removal of semi-volatile organic compounds such as diesel fuels and PCBs, which have low volatility and high hydrophobicity. The objective of this study is to develop a hot air injection method to remove semi-volatile compounds. Additionally, operation parameters such as temperature, air flow rate, and water content are evaluated. Experimental results show that diesel ranged organics (DROs) are removed in the order of volatility of organic compounds. As expected, removal efficiency of organics is highly dependent on the temperature. It is considered that more than $90\%$ of organic contaminants whose carbon numbers range between 17 and 22 can be removed efficiently by the hot air injection-extraction method (modified SVE) over the $100^{\circ}C$. It is also found that increased air flow rate resulted in high removal rate of contaminants. However, air flow rate over 40 cc/min is not effective for the operation aspects, due to mass transfer limitation on the volatilization rate of the contaminants. The effect of the water content on the decane removal is minimal, but some components show large dependence on the removal efficiency with increasing water content.

Assessment of Pollution Level and Contamination Status on Mine Tailings and Soil in the Vicinity of Disused Metal Mines in Kangwon Province (강원도 폐금속광산지역의 광미와 주변토양의 중금속 오염현황 및 오염도 평가)

  • Kim, Joung-Dae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.626-634
    • /
    • 2005
  • The objectives of this study was to assess pollution level and contamination status on tailings and soil in the vicinity of four disused metal mines in Kangwon province. As the result of total metal concentrations analysis, the pollution degree of tailings and soil decreased in the order of Wondong > Second Yeonhwa > Sinyemi ${\fallingdotseq}$ Sangdong mines. Total metal concentrations of mine tailings in this study were $1.2{\sim}78.2$ and $1.1{\sim}80.6$ times higher than those in the background soil and the tolerable levels suggested by Kloke, respectively. From these results, we found that tailings served as contamination source of nearby soil. According to sequential extraction of metals, large proportion of heavy metals in all mine tailings existed in the form of a residual fraction, and heavy metals in non-residual form was mainly associated with Fe-Mn oxide fraction and sulfidic-organic fraction. Fe-Mn oxide fraction and sulfidic-organic fraction of heavy metals may be released into and contaminated the nearby environment under the oxidation or reduction condition in long-term. In particular, the proportions of the exchangeable and carbonate fraction of Cd in mine tailings from Second Yeonhwa mine were relatively high. This suggests that Cd may be easily released into and contaminated the nearby environment in the near time. Concentrations of heavy metals in mine tailings and the nearby soil exceeded the standard (agricultural area) of Soil Environment Conservation Law. So it was thought that remediation for mine tailings and the nearby soil is needed. The pollution indices of the samples in this study were for higher than 1.0 and the pollution degree was very serious. Priority remediation site for these mines was Wondong. As Results of danger indices, it was showed that exchangeable form in Wondong and Fe-Mn oxide form in the rest mines should be removed preferentially.

Development of a Pilot-Scale Soil Washing Process (파일롯 규모의 토양세척장치 개발)

  • 장윤영;신정엽;황경엽
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.55-62
    • /
    • 1998
  • Soils contaminated with hydrocarbons and residual metals can be effectively treated by soil washing. In developing the soil washing process several major effects for separating contaminants from coarse soils progressively improved upon combinations of mining and chemical processing approaches. The pilot-scale soils washing process consists of the four major parts : 1) abrasive scouring, 2) scrubbing action using a washwater that is sometimes augmented by surfactants or other agents, 3) rinsing, and 4) regenerating the contaminated washwater. The plant was designed based upon the treatment capacity > 5 ton/hr on site. The lumpy contaminated soil fractions first experience deagglomeration and desliming passing through a rolling mill pipe. In the second unit the attrition scrubbing module equipped with paddles uses high-energy to remove contaminants from the soils. And a final rinsing system is assembled to separate the washwater containing the contaminants and very fine soils from the washed coarse soils. For recycling the contaminated washwater passes through a washwater clarifier specifically designed for flocculation, sedimentation and gravity separation of fine as well as flotation and separation of oils from the washwater. In order to more rapidly assess the applicability of soil washing at a potential site while minimizing the expense of mobilization and operation, a mobile-type soil washing process which is self-contained upon a trailer will be further developed.

  • PDF

Desorption of organic Compounds from the Simulated Soils by Soil Vapor Extraction (인공토양으로부터 토양증기추출법에 의한 유기화합물의 탈착 현상에 관한 실험 연구)

  • 이병환;이종협
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.2
    • /
    • pp.101-114
    • /
    • 1998
  • Soil vapor extraction (SVE) is known to be an effective process to remove the contaminants from the soils by enhancing the vaporization of organic compounds using forced vapor flows or applying vacuum through soils. Experiments are carried out to investigate the effects of the organic contaminants, types of soils, and water contents on the removal efficiency with operating time. In the study, simulated soils include the glass bead which has no micropore, sand and molecular sieve which has a large volume of micropores. As model organic pollutants, toluene, methyl ethyl ketone, and trichloroethylene are selected. Desorption experiments are conducted by flowing nitrogen gas. Under the experimental conditions, it is found that there are linear relationships between logarithm of removal efficiency and logarithm of number of pore volumes. The number of pore volumes are defined as the total amount of air flow through the soil column divided by the pore volume of soil column. For three organic compounds studied, the removal rate is slow for no water content, while the number of pore volumes for removal of organic compounds are notably reduced for water contents up to 37%. For the removal of dense organic compound, such as trichloroethylene, a large number of pore volumes are needed. Also, the effects of the characteristics of simulated soils on the removal efficiency of organic compounds are studied. After the characterization of soil surface, porosity of soil columns and types of contaminants, the results could provide a basis for the design of SVE process.

  • PDF

Effect of the Applied Biostimulant Depth on the Bioremediation of Contaminated Coastal Sediment (연안오염퇴적물에 주입한 생물활성촉진제의 깊이가 생물정화효율에 미치는 영향)

  • Woo, Jung-Hui;Subha, Bakthavachallam;Song, Young-Chae
    • Journal of Navigation and Port Research
    • /
    • v.39 no.4
    • /
    • pp.345-351
    • /
    • 2015
  • This study investigated the optimum depth for the application of bioremediation in contaminated coastal sediment using a lab scale column experiment. The biostimulants were placed in the top surface of the sediment facing seawater, 3cm, 6cm and 10cm of the depth from the surface, respectibely. During the experiment, the changes of organic pollutants and heavy metal fractions in the sediment were monitored in 1 month and 3month time intervals. The organic pollutants found during various analysis such as chemical oxygen demand, total solids and volatile solids, significantly reduced when the depth of the biostimulant was 3cm or less. In contrast, at a depth of over 6cm, the reduction of organic pollutants decreased, and the results were similar to the control. Heavy metals fractions in the sediment also changed with the depth of the biostimulants. The exchangeable fraction of the metals was quite reduced at the sediment surface in the column, but the organic bound and residual fractions considerably increased at a depth of 3cm. Based on this study, the optimum biostimulants depth for in-situ bioremediation of contaminant coastal sediment is 3cm from the sediment surface.