• Title/Summary/Keyword: 작은 유방

Search Result 40, Processing Time 0.026 seconds

Treatment of Micromastia with Pectus Excavatum: A Case Report (오목가슴을 동반한 작은유방증 환자의 치험례)

  • Kim, Sang Wha;Choi, Yun Seok;Lim, Jin Soo;Han, Ki Taik
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.739-742
    • /
    • 2008
  • Purpose: Breast augmentation is one of the common procedures in plastic surgery today. The shape, size and insertion plane of the implant is decided preoperatively by physical examination of the breast. Pectus excavatum is one of the most common anomalies of chest wall, characterized by a depression of the anterior chest wall. For patients with a mild type of pectus excavatum, the main purpose of the treatment is aesthetic rather than functional improvement. Two most surgical treatment options for skeletal deformity are the Ravitch technique and minimally invasive Nuss repair. Other options for soft tissue repair are implant insertion and autologous soft tissue augmentation. We performed a surgical operation with Nuss procedures and breast augmentation for a patient with mild pectus excavatum and hypoplastic breast. Methods: A 32 year-old female was presented with hypoplastic breast. Preoperative chest CT was performed, showing pectus excavatum. After Nuss procedure, we inserted saline implant(275 cc textured round breast implant, moderate profile) submuscularly to restore adequately projected breast. Results: Patient's postoperative course was uneventful without any complication. After 6 months of follow-up period, the patient had an excellent result, with high patient satisfaction and no complications. Conclusion: For patients with a mild type of pectus excavatum, who do not have cardiopulmonary symptoms and requires for aesthetic improvement, this simple approach with Nuss procedure and breast augmentation achieves excellent aesthetic correction with low complication rate and high patient satisfaction.

Usefulness of Three-phasic Bone Scan in Young Male Patients Suspected of Post-traumatic Reflex Sympathetic Dystrophy Syndrome (외상후 교감신경 이영양증이 의심되는 젊은 남자 환자들에서 삼상 골스캔의 유용성)

  • Lee, Won-Woo;Kim, Tae-Uk;Kim, Tae-Hoon;Jung, Cheoul-Yun;Moon, Jin-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.52-60
    • /
    • 2001
  • Purpose: In young male patients who suffered several kinds of trauma with subsequent suspicious reflex sympathetic dystrophy syndrome, we performed three-phasic bone scan in order to investigate its usefulness. Materials and Methods: Patients with narrow range of age (21-25. mean $22.8{\pm}1.3$, all male) were included with suspicious reflex sympathetic dystrophy syndrome of 12 feet and 5 hands. Only one was bilateral feet case and 16 were ipsilateral (Rt:13, Lt:3). The etiologic traumas were 4 fractures, 4 sprains, 3 blunt trauma, 2 cellulitis, 1 tendon tear, 1 crush injury, 1 overexercise, and 1 unknown. Radiologically 3 showed osteoporotic changes. Three-phasic bone scans were performed $21.2{\pm}7.3wks$ after trauma. Results: According to symptom complex, confirmatory reflex sympathetic dystrophy syndrome 4 cases and suspicious 13 were analyzed. All confirmatory cases (100%) showed increased uptake at delay phase with periarticular accentuation. Of confirmatory 4 cases, 2 showed increased uptake in all three phases (perfusion: P, blood pool: B, and delay: D), and other 2 revealed decreased P but, both increased B and D. Of suspicious 13 cases, 9(69.2%) had increased D (4 periarticular and 5 focal), 2 decreased D, and 2 symmetric D. In 12 foot cases, so-called weight hearing patterns - increased contralateral sole at P and B - were revealed in 7(58.3%). Conclusion: Diffuse periarticular increased uptake at delay phase of three-phasic bone scan was a compatible finding to reflex sympathetic dystrophy syndrome in young male patients whose symptom complex strongly designated post traumatic reflex sympathetic dystrophy syndrome.

  • PDF

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF

Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study (약하게 조영증강된 병변의 유방 전용 CT 영상의 대조도 개선을 위한 적응적 영상 재조정 방법: 팬텀 연구)

  • Bitbyeol Kim;Ho Kyung Kim;Jinsung Kim;Yongkan Ki;Ji Hyeon Joo;Hosang Jeon;Dahl Park;Wontaek Kim;Jiho Nam;Dong Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1477-1492
    • /
    • 2021
  • Purpose Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed. Materials and Methods Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images. A piece of pork was also scanned as a subclinical trial. The image quality was evaluated using image contrast and contrast-to-noise ratio (CNR). The difference of imaging performances was confirmed using student's t test. Results Total mean image contrast of AIR (0.70) reached 74.5% of that of DECT (0.94) and was higher than that of SECT (0.22) by 318.2%. Total mean CNR of AIR (5.08) was 35.5% of that of SECT (14.30) and was higher than that of DECT (2.28) by 222.8%. A similar trend was observed in the subclinical study. Conclusion The results demonstrated superior image contrast of AIR over SECT, and its higher overall image quality compared to DECT with half the exposure. Therefore, AIR seems to have the potential to improve the detectability of lesions with dedicated breast CT.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Biological activities of Hovenia dulsis $T_{HUNB}$ (헛개나무의 생리활성 탐색)

  • Lee, Mi-Kyoung;Kim, Young-Kil;An, Sang-Wook;Kim, Min-Hae;Lee, Jin-Ha;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.7 no.3
    • /
    • pp.185-192
    • /
    • 1999
  • Four different parts of Hovenia dulcis $T_{HUNB}$; fruit, bark, vessel area, fruit coat were extracted with water and ethanol. The ethanol extracts of bark, fruit coat and fruit were fractionized into diethyl ether, chloroform and aqueous partitions. Ethanol extract of fruit coat increased the activity of cathepsin B up to 55 %, which can enhance the alcohol dehydration in the liver. The ethanol extracts was more effective than water extracts against the growth of Hep3B, MCF7. The ethanol extracts of bark (0.5mg/ml) inhibited 90% the growth of MCF7. Each extracts and fractions (0.5mg/ml) did not show considerable cytotoxicity on HEL299. In overall, most of the fractions had similar effects to ethanol extracts; however, diethyl ether and chloroform fractions had higher bioactivity than ethanol extracts, but aqueous fraction.

  • PDF

The Study on Ejection Fraction Change According to Patient Position Difference in Gated Blood Pool Scan (게이트심장혈액풀 스캔에서 환자의 자세 변화에 따른 심박출계수의 변화 연구)

  • Choi, Ho-Yong;Kim, Da-Eun;Jeong, Jae-Hun;Yun, Sang-Hyeok;Kim, Yeong-Seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.91-95
    • /
    • 2012
  • Purpose: In this study, we evaluated the ejection fraction (EF) according to the difference of patient position in Gated Blood Pool (GBP) scan. Material and Methods: The analysis was performed to 80 patients ($51.2{\pm}17.4$ years old) who examined GBP scan in Department of nuclear medicine, National Cancer Center from March 2011 to August 2011. We divided the patients into two groups; one group received conventional position (raise left arm up supine) and supine position (group 1) and the other group received conventional position and left arm back down supine position (group 2). To observe the change EF according to patient position difference, the image was reconstructed and analyzed by Xeleris (GE, USA). We measured body mass index (BMI) of patients. Result: In group 1, EF error less than 3% occurred at a rate of 72.5% (29 of the 40 patients). In group 2, EF error less than 3% occurred at a rate of 79% (32 of the 40 patients). The patient's BMI did not affect ejection fraction. Conclusion: The EF error of left arm back down supine position closer to conventional position than in supine position shows the results.

  • PDF

Consideration of Standardized Uptake Value (SUV) According to the Change of Volume Size through the Application of Astonish TF Reconstruction Method (Astonish TF 재구성 기법의 적용을 통한 체적 크기의 변화에 따른 표준섭취계수(SUV)에 관한 고찰)

  • Lee, Juyoung;Nam-Kung, Sik;Kim, Ji-Hyeon;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.115-121
    • /
    • 2014
  • Purpose: In addition to improving the quality of the PET image, through much research, the development of various programs are performed. Astonish TF reconstruction techniques by Philips can confirm the improved contrast of the lesion. Also, It's image reconstruction of 2 mm is possible with rapid reconstruction rate than conventional. In this study, we compared and evaluated Standardized Uptake Value (SUV) in accordance with the 2 mm reconstruction techniques and traditional 4 mm from the $^{18}F-FDG$ PET whole body image. Materials and Methods: In the phantom experiment, NEMA IEC body phantom (sphere: 10, 13, 17, 22, 28, 37 mm) was used to obtain images by using GEMINI TF 64 PET/CT (Philips, Cleveland, USA). Also, In the clinical images, we performed $^{18}F-FDG$ PET/CT examination to 30 women (age: $55.1{\pm}11.3$, BMI: $24.1{\pm}2.9$) with a diagnosis of breast cancer. After that, we reconstructed images in 2 mm and 4 mm respectively. The region of interest was drawn to acquired images. Since then, we measured SUV and statistically analyzed with SPSS ver.18 by using EBW (Extended Brilliance Workstation) NM ver.1.0. Results: After analyzing the result of the phantom study, there was a tendency that the bigger hot sphere size, the higher SUV. If you compared the 2 mm reconstruction techniques to 4 mm, it increased 95.78% in 10 mm, 50.60% in 13 mm, 25.00% in 17 mm, 30.04% in 22 mm, 31.81% in 28 mm, and 27.84% in 37 mm. Through the result of the analysis of the 2 mm reconstruction techniques and 4 mm in clinical images, it appeared that SUV of 2 mm was higher than that of 4 mm. Also the smaller the volume was, the more the change rate increased. Conclusion: After analyzing the result of the clinical picture and phantom experiments applied by Astonish TF reconstruction techniques, as the size of the volume was small, the change rate of the SUV increased. Therefore, it was necessary to further research about the SUV correction for accurate and active utilization of 2 mm reconstruction techniques which had excellent lesion discrimination ability and contrast in clinic.

  • PDF

CHEMOPREVENTION OF COLON CANCER BY THE KOREAN FOOD STUFFS COMPONENTS

  • Kim, Dae-Joong;Shin, Dong-Hwan;Ahn, Byeong-Woo;Jang, Dong-Deuk;Hiroyuki Tsuda;Shoji Fukushima
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.05b
    • /
    • pp.106.2-132
    • /
    • 2002
  • 형질전환 (유전자 결핍; Knockout) Min 마우스를 이용하여 대장암 발생에서 배추, 양배추 주성분인 indole-3-carbinol (I3C)의 대장암 예방효과를 규명하고자 하였다. 실험동물로는 C57BL/6J-Apc$^{min/+}$(Min 마우스)계의 5내지 6주령의 수컷 이형접합체 형질전환 마우스 70마리와 C57BL/6J계의 동일 산자, 동일 주령의 수컷 wildtype 비형질전환 마우스 10kfl를 The Jackson Laboratory 사 (Bar harber, ME, USA)로부터 직접 구입하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 (Min)마우스 70마리를 각 군 20내지 25마리씩 세군으로 나누었다. Group 1에는 20마리, Group 2에는 25마리, Group 3에는 25마리를 배치하고, I3C 투여 실험군 (Group 1과 2)에는 실험시작시에 AIN-76A 분말사료에 I3C가 각각 100 및 300ppm이 함유되도록 조제하여 공급하였다. 그리고 실험군(Group 3)에는 실험시작부터 종료시까지 AIN-76A 정제고형사료(Teklad사, WI, USA)를 자유로이 급이하였다. 각군간의 체중, 사료 및 음수소비량을 매 2주마다 측정하였고, 10주간 (16주령)의 실험종료시에는 최종체중과 간장, 신장, 비장 등의 장기무게를 측정하여 상대장기 무게비를 산출하였다. 대조군으로서 C57BL/6J계의 동일 산자, 동일 주령의 수컷 wildtype 비형질전환 마우스 10마리는 같은 조건의 사육실에서 AIN-76A 정제고형사료를 33주간 자유로이 급이하였다. 실험동물은 부검전에 하룻밤 동안 절식하고 이산화탄소 흡입 마취하에서 흉대동맥을 절단하여 방혈하고 각 장기(심장, 폐, 위)를 적출하여 생리심염수에 넣어 장기무게를 측정하고 포르말린에 고정하였다. 소장과 대장의 검사를 위하여 위의 식도부위와 직장을 실로 결찰하여 적출하고 생리심염수를 주입하여 팽창시켜, 십이지장, 공장, 및 회장, 그리고 대장으로 나누어 여과지에 펼친 후 포르말린에 고정하였다. 소장과 대장은 육안 및 자동 영상분석길ㄹ 이용한 분석이 끝난 후에 각 부위별로 4-6개의 절편을 작제하여 포르말린에 재고정하고, 통상적인 조직처리과정, 파리핀 포매 및 3-4$\mu$m 두께의 조직절편을 제작하여 H&E 염색을 실시하여 현미경으로 검경하였다. 약 1주일간의 포르말린 고정이 끝난 소장 및 대장을 부위별, 별 종양개수 및 분포를 자동영상분석기(Kontron Co. Ltd., Germany)로 분석하였다. 체의 변화, 장기무게, 사료소비량 및 마리당 종양의 개수에 대한 통계학적 유의성 검증을 위하여 Duncan's t-test로 통계처리 하였고, 종양 발생빈도에 대하여는 Likelihood ration Chi-square test로 유의성을 검증하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군의 대장선종의 발생률은 84%(Group 3; 21/25례)로써 I3C 100ppm 및 300ppm을 투여한 경우에 있어서는 각군 모두 60%(Group 1; 12/20 례, Group 2; 15/25 례)로 감소하는 경향을 나타내었다. 대장선종의 마리당 발생개수에 있어서는 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군은 1.40$\pm$0.24(100%)에 비하여 I3C 저농도 투여 실험군(Group 1; 0.85$\pm$0.23; 61%, P<0.01), 그리고 I3C 고농도 투여 실험군(Group 2 ; 1.32$\pm$0.29 ; 94%)의 순으로 감소하였다. 선종의 크기별 종양의 발생개수의 분포에 있어서 I3C 저농도 투여 실험군에 있어서는 선종의 크기가 3mm이하의 수가 현저하게 감소하였다. C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스에 AIN-76A 정제사료만을 투여한 대조군의 부위별 소장선종의 발생수는 십이지장부위를 제외하고 각 군에서 유의한 변화는 관찰되지 않았다. 십이지장 종양의 발생개수에서만 I3C 저농도 투여 실험군(Group 1 ; 3.11$\pm$0.85)이 대조군 (Group 3: 1.48$\pm$0.35) 및 I3C 고농도 투여 실험군(Group 2: 1.56$\pm$0.47)에 비하여 유의성 있게 증가하였다. (P<0.05). 따라서 I3C은 소장에서는 암예방 효과가 뚜렷하지 않으나, 대장에 대한 암에방 효과가 있을 것으로 생각된다. 소장 및 대장을 제외한 간장, 신장, 비장, 심장, 폐 그리고 위 등의 기타 장기에서의 조직병리학적 변화는 관찰되지 않았다. 소장 및 대장의 종양은 선종(polyps)으로 관찰되었다. 지난 10여년간 형질전환 및 유전자 결핍 실험동물의 종류가 기하 급수적으로 증가하여 이용되고 있다. 가족성 대장 선종성 용종증(FAP)의 대표적인 모델로 이용되고 있는 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스를 사용하여 배추나 양배추의 주요성분인 Indole-3-carbinol(I3C)의 대장암 예방효과가 있는지를 검색하여 본 결과 AIN-76A정제사료만을 투여한 대조군의 대장선종의 발생률 84%에 비하여 I3C 100 및 300ppm을 투여한 실험군에 있어서 각군 모두 60%로서 감소하는 경향을 나타내었으며, 대장선종의 마리당 발생개수에 있어서는 대조군의 1.40$\pm$1.041를 100%로 환산하였을 경우 I3C 저농도 및 고농도 투여 실험군에서는 각각 약 61%와 94%를 나타내여 감소하였다. 특히 대장선종의 크기별 분포에 있어서 선종의 크기가 3mm이하의 수가 현저하게 감소하였다. 따라서 저농도 I3C의 투여는 실험적 유전성 가족성 대장 선종성 용종증 모델에 있어서 어느정도 암 예방효과가 있는 것으로 생각된다. 그러나 소장 선종의 발생에는 별 영향이 없는 것으로 생각된다. 그러나 본 실험에 사용된 C57BL/6J-Apc$^{min/+}$계 수컷 이형접합체 형질전환 마우스는 실험개시 시점이 7내지 8주령이 경과하여 이미 태생기부터 소장 및 대장의 선종 발생이 진행되어 온 것을 감안하고 특히 비스테로이드계 항염증 소염제(NSAIDS)와 같은 강력한 COX-2억제제가 아님을 고려하면, 상당한 선종의 발생을 억제할 수 있는 가능성이 매우 높다고 생각한다. 또한 이제까지 배추나 양배추 성분의 복합성분들에 대한 실험적 대장암 모델에서의 촉진효과 등에 대한 보고들이 있어 온 점을 고려할 때 위암(Kim 등, 1994) 간암(Kim 등, 1994), 유방암(Grubbs, 등, 1995; Bradlow 등, 1995)에 대한 예방효과가 있을 것으로 생각된다. 앞으로 이러한 종양조직내에서의 COX-2 및 iNOS mRNA와 단백질의 발현정도를 분자병리학적으로 연구중에 있으며, 향후 십자화과식물 성분인 indole-3-carbinol이 마우스뿐 만 아니라 랫드의 화학발암물질에 의한 대장종양에 대한 억제효과 있는지 연구 필요가 있다. Min 마우스와 같은 형질 전환(유전자결핍;knockout) 실험동물을 이용한 새로운 중기 발암성 시험범의 확립을 통한 각종 환경 유해물질의 발암성 유무 및 COX-2 억제작용이 있는 식품인자의 암예방 후보물질을 체계적으로 검색하는데 유용하게 활용될 수 있을 것으로 생각한다.

  • PDF