• 제목/요약/키워드: 작동액

검색결과 59건 처리시간 0.029초

Electrochemical Characteristics of Ru Added Li4Ti5O12 as an Anode Material (Ru를 첨가한 음극활물질 Li4Ti5O12의 전기화학적 특성)

  • Cho, Woo-Ram;Na, Byung-Ki
    • Clean Technology
    • /
    • 제20권4호
    • /
    • pp.433-438
    • /
    • 2014
  • There is an increasing interest in the development of rechargeable batteries suitable for use in both hybrid electric vehicles and energy storage systems that require higher charge & discharge rates, bigger battery sizes and increased safety of the batteries. Spinel-type lithium titanium oxide ($Li_4Ti_5O_{12}$) as a potential anode for lithium ion batteries has many advantages. It is a zero-strain materials and it experiences no structural change during the charge/discharge precess. Thus, it has long cycle life due to its structural integrity. It also offers a stable operation voltage of approximately 1.55 V versus $Li^+/Li$, above the reduction potential of most organic electrolyte. In this study, Ru added $Li_4Ti_5O_{12}$ composites were synthesized by solid state process. The characteristics of active material were investigated with TGA-DTA, XRD, SEM and charge/discharge test. The capacity was reduced when Ru was added, however, the polarization decreased. The capacity rate of $Li_4Ti_5O_{12}$ with Ru (3%, 4%) addition was reduced during the charge/discharge precess with 10 C-rate as a high current density.

An Empirical Study on the Size Distribution of Venture Firms in the center of KOSDAQ Listed Companies (국내 벤처기업 진화과정에 관한 실증분석 - 코스닥상장 기술벤처기업 분석을 중심으로 -)

  • Cho, Sang-Sup;Yang, Young-Seok
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • 제6권1호
    • /
    • pp.23-37
    • /
    • 2011
  • This paper is brought to carry out an empirical study whether evolution process of venture firm's scale is following the Gibrat's law; random evolution process, or Pareto law; self-organizing process. The empirical test, as attaching theoretical explanation, of this research utilize the serial data samples of 92 KOSDAQ listed companies from the year of 2005 through 2008. Summarizing the research results are as followed. First, Gini Coefficients representing the density of venture firm's scale has been constantly reduced since the year of 2005 in terms of number of employee, while these index increased during the same time period from the perspective of sales volume. Second, the evolution process of Korea venture firm's scale is following the Power Law related to Pareto Law. In particular, estimated Pareto coefficient, ${\alpha}$, is shown lower than 1 which is significant result. Third, the probability of joining in the top tier group of firm starting from the early stage growing is forecasted into 6.9%, the result which emphasize the starting scale of venture firm play an important role in long term evolution of venture firm.

  • PDF

Optimal Design Standard and Application of Low Cost, High Performance Scrubber for Absorbing Hazardous Gas (유해가스 흡수처리를 위한 저비용 고효율 스크러버의 최적 설계기준 및 현장적용 방안)

  • Jung, Ga-Young;Lim, Kyung-Min;Ma, Byung-Chol
    • Journal of the Korean Institute of Gas
    • /
    • 제25권3호
    • /
    • pp.39-45
    • /
    • 2021
  • Scrubbers that treat hazardous materials at workplaces have high treatment efficiency; however, the design is complex, and pumps need to be operated 24 hours a day, which can be costly. Therefore, to minimize the operating costs, small businesses do not install scrubbers, or operate them while circulation pumps are suspended. Hence, this study investigated the application of low-cost, high-performance scrubbers that can be used economically in small businesses. Low-cost, high-efficiency scrubbers are applied to bubble columns to utilize devices for hazardous chemical absorption treatment purposes, and for the development of these scrubbers, absorption performance was reviewed and the optimal application method was studied under certain conditions. The changes in the absorption performance of hazardous gas were studied in certain environments by varying the physical conditions, and the optimal application methods were analyzed. The results showed that, while it was possible to treat some of the gas flowing into the low cost, high performance scrubber, the treatment capacity was reduced. Performance degradation was prevented by supplying an absorption liquid, and a certain level of absorption was maintained depending on the amount of circulation. Based on this, three types of site application methods of low cost, high performance scrubbers were presented. In addition, the appropriate timing of circulation and anti freezing measures were also discussed.

Study for Failure Examples Including with Gas filter Clogging of Emergency Cutting Valve, Assemblying Part Damage of Solenoid Valve, Contact Damage of LPG Switch Connector Fin in a LPG Car (LPG 자동차의 긴급차단밸브 기상필터막힘, 솔레노이드밸브 조립부손상, LPG 스위치 커넥터 핀 접촉불량에 관련된 고장사례 연구)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Kim, Jee Hyun;Kim, Sung Mo;Jung, Dong Hwa;You, Chang Bae;Moon, Hak Hoon;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • 제26권1호
    • /
    • pp.1-6
    • /
    • 2022
  • This paper is a purpose to study and analyze the engine starting failure examples for LPG car. The first example, the researcher verified the phenomenon that didn't supply the fuel because of filter clogging by fine alien substance in the gas valve line when he inspected the emergency cutting valve. The second example, there was no the influence of gas leakage when the solenoid operated at first. But the damage part of solenoid assemblying face wad downed a durability according to running a valve. Eventually, the researcher checked on the phenomenon of engine stopping by no gas feeding in solenoid because of leaking of gas. The third example, the researcher sought that the wiring sheaths of connector fin between EGR 10A fuse and LPG switch verified the burn-out phenomenon due to the bad contacting as tension damage produced the overheating. Therefore, the manager of a car has to do pre-inspection no producing electric failure and he must maintain his car with optimum condition.

A Study on the Adaptability of Oxygen Reduction System to Fire in Cold Storage through Fire Simulation Analysis (화재시뮬레이션 분석을 통한 냉장·냉동 창고 화재의 저산소 시스템 적응성에 관한 연구)

  • Min-Seok Kim;Sang-Bum Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • 제19권1호
    • /
    • pp.117-127
    • /
    • 2023
  • Purpose: The number of Cold Storages at home and abroad is on the rise, fires in large Cold Storages have recently occurred. As fires continue to occur and property damage is on the rise every year, the importance of preventing fires in large Cold Storage is growing. Method: Real Cold Storages were investigated on-site and fire cases were analyzed to derive and analyze fire risk, and the ORS, which is emerging as an adaptive fire prevention technology of Cold Storage, was investigated through FDS. Result: oxygen concentration 21, 15.7% and 17.7, 16.7% were analyzed through FDS, and flashover was reached within 3~4 minutes from 21, 17.7, 16.7%, but if oxygen concentration was lowered to 15.7%, it didn't ignite for 13 minutes. Conclusion: This study understood the concept and general part of the ORS, modeled the freezer through FDS, and analyzed the oxygen concentration to analyze the fire protection adaptability of the ORS. In the future, it is expected that large-scale empirical experiments and related regulations will be prepared to provide solutions for fire prevention in Cold Storages in blind spots of fire.

GIS-based Disaster Management System for a Private Insurance Company in Case of Typhoons(I) (지리정보기반의 재해 관리시스템 구축(I) -민간 보험사의 사례, 태풍의 경우-)

  • Chang Eun-Mi
    • Journal of the Korean Geographical Society
    • /
    • 제41권1호
    • /
    • pp.106-120
    • /
    • 2006
  • Natural or man-made disaster has been expected to be one of the potential themes that can integrate human geography and physical geography. Typhoons like Rusa and Maemi caused great loss to insurance companies as well as public sectors. We have implemented a natural disaster management system for a private insurance company to produce better estimation of hazards from high wind as well as calculate vulnerability of damage. Climatic gauge sites and addresses of contract's objects were geo-coded and the pressure values along all the typhoon tracks were vectorized into line objects. National GIS topog raphic maps with scale of 1: 5,000 were updated into base maps and digital elevation model with 30 meter space and land cover maps were used for reflecting roughness of land to wind velocity. All the data are converted to grid coverage with $1km{\times}1km$. Vulnerability curve of Munich Re was ad opted, and preprocessor and postprocessor of wind velocity model was implemented. Overlapping the location of contracts on the grid value coverage can show the relative risk, with given scenario. The wind velocities calculated by the model were compared with observed value (average $R^2=0.68$). The calibration of wind speed models was done by dropping two climatic gauge data, which enhanced $R^2$ values. The comparison of calculated loss with actual historical loss of the insurance company showed both underestimation and overestimation. This system enables the company to have quantitative data for optimizing the re-insurance ratio, to have a plan to allocate enterprise resources and to upgrade the international creditability of the company. A flood model, storm surge model and flash flood model are being added, at last, combined disaster vulnerability will be calculated for a total disaster management system.

An Analysis on the Value Chain and the Value System of the Korean Wind Power Industry (한국 풍력산업의 가치사슬 및 가치시스템 분석)

  • Ryu, Jae-Ho;Choi, Ta-Gwan;Park, Jung-Gu
    • Journal of Energy Engineering
    • /
    • 제23권1호
    • /
    • pp.46-57
    • /
    • 2014
  • This study analyzes whether the value-added structure of Korean wind power industry exhibits a virtuous cycle through the value chain(VC) within wind power firms and the value system(VS) among the wind power industries, using a regression analysis based on a survey about Korean wind power companies. According to the VC, the government's R&D support is analyzed to have contributed to an increase in the R&D investments of the wind power companies. An increase in corporates' R&D investments has led to an increase in corporates' R&D outputs, and in turn, induced a remarkable increase in the amounts of production. But an increase in production has not led to a decrease in the costs of production, not resulting in an increase in profit rates per sales amount. In addition, while an increase in profit rates is analyzed to have contributed to an increase in production, this did not induce further investments in corporate's R&D. The virtuous cycle of the value chain in Korean wind power firms is, therefore, analyzed to be weak. Next, the VS is analyzed by dividing the whole chain into the system group including rotor blades, gear boxes, and power generators, and the structure group, such as towers. Two groups are analyzed to have mutually positive effects in the processes of the government's support for corporates' R&D, corporates' investment in R&D, R&D outputs, and profit rates per sales amount. Such mutual positive effects are, however, not found in the processes of the amounts of production and the costs of production. These results demonstrates that the value system of Korean wind power industry is not completed. This study has a policy implication to need further efforts to create the virtuous cycle in the VC and VS of Korean wind power industry.

Optimization of Retrovirus Mediated-Gene Transfer into Hematopoietic Stem Cells (Retrovirus를 이용하여 조혈모세포에 유전자를 전달하기 위한 최적화)

  • Kim, Sang-Gyeong;Seo, Heon-Seok;Lee, Jong-Won;Sin, Dong-Geon;Lee, Jae-Gwan;Kim, Hyeon-Min;Kim, Jae-Sik;Seo, Jang-Su
    • KSBB Journal
    • /
    • 제14권5호
    • /
    • pp.593-599
    • /
    • 1999
  • In this study, optimal conditions to infect CD34 positive cells containing hematopoietic stem cells obtained from cord blood and bone marrow were found using two different retroviral vectors expressing human growth hormone (hGH) and $\beta$-galactosidase. CD34 positive cells were successfully infected with recombinant retroviruses only when the CD34 positive cells were co-cultured with packaging cells secreting recombinant retroviruses. To find the highest infection efficiency for the gene transfer, CD34 positive cells from cord blood were co-cultured with packaging cells secreting recombinant retroviruses encoding E. coli lacZ gene. The highest infection efficiency was obtained when CD34 positive cells were cultured for 3 days, and then co-culturing was done for another 2 days. When CD34 positive cells from bone marrow were co-cultured with packaging cells secreting recombinant retroviruses encoding hGH gene, the maximum amount of hGH was also secreted at the same conditions found above, i.e. 3 days of culture and 2 days of co-culture. These results show that there are optimal conditions for the gene transfer into hematopoietic stem cells regardless of sources of target cells or retroviral vectors used to infect.

  • PDF

Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure (유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과)

  • Ryu, Young Hyo;Uhm, Han Sup;Park, Gyung Soon;Choi, Eun Ha
    • Journal of the Korean Vacuum Society
    • /
    • 제22권2호
    • /
    • pp.55-65
    • /
    • 2013
  • Sterilization of Neurospora crassa has been investigated in this research by using a surface air plasma with dielectric barrier discharged (DBD) structure under atmospheric pressure. The sinusoidal alternating current has been used in this experiment with discharge voltage of 1.4~2.3 kV. The phase difference between the voltage and current signals are found to be almost 80 degree due to the capacitive property of dielectric barrier. Temperature on the biomaterials has been minimized by radiating the heat with the air cooling system. It is noted that the substrate temperature remains under 37 degree for plasma exposure time of 10 minutes with operation of cooler system. It is found that the ozone, $O_3$, has been measured to be about 25~30 ppm within 1 cm region and to be about 5 ppm at the 150 cm downstream region away from the suface plasma. It is also noted that the nitric oxide, NO, and nitric dioxide, $NO_2$, are not nearly detected. Germination rate and mitochodrial activity of Neurospora crassa immersed in the deionized water have been found to be drastically decreased as the plasma treatment time and its electrical power are increased in this experiment. Here, the mitochondrial activity has been analyzed by MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) assay. However, sterilization of Neurospora crassa immersed in the Vogel's minimal media has been found to be low by plasma treatment, which is caused by surrounding background solution. This research shows the sterilization possibility of Neurospora crassa by using the noncontated surface DBD plasma, which is different from the plasma jet. This is mainly attibuted to the reactive species generated by the surface plasma, since they play a major role for inhibition of micobes such as Neurospora crassa.