• Title/Summary/Keyword: 자체진단

Search Result 470, Processing Time 0.039 seconds

A Consulting Case Study on the Small Start-up through using the Business Model Canvas (소규모 창업기업의 사업진단과 컨설팅을 위한 비즈니스모델캔버스의 활용 사례연구)

  • Pyo, Won-Ji;Ha, Hwan-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.10
    • /
    • pp.561-569
    • /
    • 2015
  • Many start-ups have many realistic hardships in getting management diagnosis about whether their business model are properly going. For this reason, there is the need for an easy and simple method that makes it possible to conduct a strategic management through the analysis and management diagnosis of the business model. The Business Model Canvas(BMC) has been popularized as a tool to help entrepreneurs describe, design, challenge, invent and pivot their business model. This model gives a framework to describe the most important building blocks(9 blocks) of existing business. Entrepreneurs can make their own business analyses and craft their own solutions through using this model. In this study, we conducted consulting by using the BMC on the NARUATO which is a small start-up in the healthy food industry. This case study can use as a learning material for entrepreneurship education.

Computer simulation for the machinery diagnosis by using the bispectrum (바이스펙트럼 해석의 설비진단을 위한 컴퓨터 시뮬레이션)

  • 오재응;정준회;염성하
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.128-133
    • /
    • 1986
  • 설비진단에 응용되는 신호처리의 기법으로는 파워스펙트럼, 바이스펙트럼, 켑스트럼 등이 사용되었다. 파워스펙트럼은 이론적인 면과 계산과정 그리고 신호처리에서의 적용방법등이 잘 알려져서 성공적으로 사용되어져 왔다. 특히 음향분야에서는 여러가지 응용기술이 개발되어 실제계에 적용되고 있으며 계측장비도 파워스펙트럼 해석법에 알맞게 개발되어져 왔다. 파워스펙트럼해석법을 사용하여 진동계를 구성하는 각 요소들의 고유진동수와 진동계 전체를 나타내는 진동파들의 주파수성분 간의 관계에 의하여 진동의 원인 및 소음원 등을 추정하는 것이 가능하다. 그러나 파워스펙트럼은 일반적으로 정상적인 신호를 갖는 진동계에 대한 해석 일 때는 그 이론과 실제가 잘 일치하지만, 진동계 자체가 항시 임의의 주파수를 갖고서 움직일 때 그 해석에는 다음과 같은 문제점이 생긴다. 첫째, 불규칙한 진동계에서는 규칙적인 진동계보다 잡음의 영향을 많이 받기 때문에 실제로 잡음이 진동계의 고유주파수 부근에 있을 경우에는 파워스펙트럼해석으로는 불가능한 경우가 있다. 둘째, 진동파 중에 포함되어 있는 위상이라는 중요한 정보가 없다. 셋째, 시간지연에 따른 진동계의 정확한 정보를 얻을 수 없다. 이상에서 볼 때 파워스펙트럼해석법은 한계가 있음을 알 수 있다. 따라서 본 논문은 바이스펙트럼이라는 해석법을 사용하여 정상과정에서 비정상과정으로 시간지연에따라 변하는 진동계 또는 정상적인 진동계의 저주파에서의 상호간섭 정도 및 위상관계를 관찰함으로써 파워스펙트럼과 비교하여 바이스펙트럼해석법의 타당성을 검토한다. 바이스펙트럼의 실제적인 계산방법은 P. J. Huber가 세가지 접근 방법을 제안했는데 시간영역에서의 평균화를 행하여 계산하는 법, 연속된 기록들을 평균화하는 것, 주파수 영역에서의 평균화를 행하는 것 등이 있다. 본 논문에서는 FFT를 먼저 행하고 파워스펙트럼과 바이스펙트럼 및 바이코히어런스를 구하였다. 그러나 바이스펙트럼해석법은 수치해석적인 면에서 볼 때 파워스펙트럼해석법에 비하여 미약한 점이 많고 통계학적인 그 의미가 확실하게 알려져 있지 않기 때문에 본 논문에서는 시뮬레이션을 통하여 그 물리적 의미를 규명하고져 한다.

  • PDF

A Study on the Estimation of Remodeling Method by Focused on Apartment House User's Request (공동주택 사용자 중심의 리모델링 방법 평가에 관한 연구)

  • Yoo, In-Geun;Kim, Chun-Hag;Yoon, Yer-Wan;Yang, Keek-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.211-222
    • /
    • 2004
  • Lately construction industry tends to prefer remodeling of existing buildings rather than new construction or reconstruction of buildings due to strengthening of several restriction related to real estates along with prolonged depression. And also, remodeling of building costs less and creates less wastes compared to reconstruction and so it is more profitable in financial and environmental view. However remodeling is process of creating new environment with existing building. Therefor remodeling must follow the procedure realizing problem and fix the problem based on through investigation on existing building and users requirement must be faithfully reflected. Specially in case of apartment houses, since vagueness on ownership and management authority on common parts exists. Hereupon, in this study we are to present the procedure of analyzing apartment house remodeling method through user requirement by approaching to several considerable factors in user request side.

Development of Fluid Silicic Acid Coating with Paint Materials of the Steel Electric Power Facilities (강재 전력시설물을 위한 액상 규산질 도장제 개발에 대한 연구)

  • Kwon, Seung-Jun;Park, Sang-Sun;Lee, Sang-Min;Lee, Myung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.57-64
    • /
    • 2008
  • Generally, organic paint on steel towers can guarantee durability in normal condition but occasionally shows its deterioration on the power line tower and electric power facilities, exposed to light(ultra violet) or heat. The objective of this study is to develope the inorganic paint material based on fluid silicic acid for steel electric power facilities. For the purpose, optimal mixture proportion is derived through 6 preliminary test and, additionally physical and durability performance test are carried out for selected specimens. The performances of developed organic paint material is similar to those of organic paint material. If resistance to chemical attack is improved, the developed inorganic paint is evaluated to replace the organic paint and obtain wide application.

Application of Isolation System to the Lighthouse Structure (등대구조물의 면진시스템 적용방안 연구)

  • Hur, Moo Won;Chun, Young Soo;Kim, Dong Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.27-36
    • /
    • 2013
  • In this study, seismic isolation technology to the lighthouse structure is suggested and isolation effects on response reduction are studied for three types of isolation models with the proposed seismic isolation technology. A seismic isolation system is installed on the base of the lighthouse structure in model 1, on the base of the lighthouse lens in model 2, and on the base of both of them in model 3. The dynamic time history analysis verifies that in case of model 1, the earthquake loading is greatly reduced and the accelerations of superstructure are greatly reduced. Also, the inter-story drifts are very small and can be neglected. The isolated model is in translational state and can be seen as a rigid whole. as a results, model 1 is very effective to mitigate the influence of earthquake on structures. In model 2, isolation effects are valid but special care should be taken to failure of the non-isolated lighthouse sub-structure. In model 3, isolation effects are also valid but the effects are small. model 3 is less effective than model 1.

Analytical Study for Seismic Capacity Enhancement for Non-structural Elements in Power Plants (발전플랜트 시설 내부 비구조요소의 내진 안전성 향상을 위한 해석적 연구)

  • Bang, Jin Soo;Kwon, Yangsu;Yim, Hong Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • In the case of power plant facilities, seismic stability of non-structural elements is important. In particular, Cabinet structures to which electrical equipment is attached, should have functional safety against earthquakes. Therefore, in this study the dynamic characteristics of non-structural elements inside existing power plant buildings were identified and the response level generated during dynamic behavior was analyzed. In addition, The steel plate dampers were adopted and adjusted to suit the size of the target equipment. In order to derive the optimal seismic reinforcement, the variables according to the attachment location were set and the responses were analyzed by the seismic movement input before and after reinforcement.

Numerical Study on the Characteristics of Thermal Plasmas Disturbed by Inserting a Langmuir Probe (랑뮤어 탐침에 의해 변형된 열플라즈마 특성에 관한 해석적 연구)

  • Lee, J.C.;Kim, Y.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.189-194
    • /
    • 2008
  • Measurements with a Langmuir probe, which are the most often used procedures of plasma diagnostics, can disturb plasma flows and change its characteristics quite a little because the probe should be inserted into thermal flowing plasmas. In this study, we calculated the characteristics of thermal plasmas with and without the probe into an atmospheric argon free-burning arc numerically, and investigated aerodynamic and thermal disturbances with temperature and axial velocity distributions. For the modelling of thermal plasmas, we have made two governing equations, which are on the thermal-flow and electromagnetic fields, coupled together with a commercial CFD package and user-coded subroutines. It was found that thermal disturbances happened to both sides of the probe, before and behind, seriously. Due to the aerodynamic disturbance, we could find that there were the stagnation point in front of the probe and the wake behind it. Therefore, aerodynamic and thermal disturbances caused by the probe insertion should be considered to increase the reliability of the probe diagnostics.

실리콘 다이오드를 적용한 다채널 중성 입자 분석기 개발

  • Cheon, Se-Min;Jwa, Sang-Beom;Gang, In-Je;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.211-212
    • /
    • 2011
  • 플라즈마를 제어하기 위해서는 플라즈마의 온도, 밀도, 에너지 분포등과 같은 플라즈마의 특성을 정확히 측정할 수 있어야한다. 핵융합발전에서는 플라즈마를 발생하기 위하여 플라즈마의 온도, 밀도 등 각종 변수들을 시공간적으로 계측, 분석할 수 있는 진달설비를 사용하고 있으며, 정확한 플라즈마 제어와 측정을 위한 새로운 진단기술을 개발하고 있다. 그리고 중요한 변수중에 하나인 플라즈마 이온온도를 측정하기 위해 중성입자 검출법이 잘 알려져 있다. 이 실험은 수소 중성입자가 토카막 내부의 플라즈마 이온과 충돌하면서 생성된 고속 중성입자의 에너지를 분석하는 실험이다. 본 연구의 실험방법은 수소 중성입자를 이온빔 장치에서 이온화 시킨 후 자체 제작한 가속기를 통하여 가속시켜 에너지 특성을 분석을 하는 것이다. 본 연구의 실험장치로 에너지 교정용 100 keV 이온빔 소스를 제작 하였고 이온빔 장치 내부에 수소기체를 주입하고 기체방전을 일으켜 플라즈마를 발생시켰다. 이온빔 외부에는 팬을 설치하고 전도성이 강한 물 대신 전도성이 약한 오일을 사용하여 냉각 하였다. 이온빔 장치와 결합될 이온 가속장치는 지름 300 mm, 두께 2 mm의 원형 구리판을 여러층으로 쌓아 전극으로 제작하였고 전극과 전극 사이에서 코로나 방전과 스파크를 방지하기 위해 전극 둘레에 코로나링을 설치 하였다. 또한 전극 사이마다 1G${\Omega}$의 저항을 설치한 후 고전압을 생성하여 이온 가속 효율을 증대시켰다. 진공시스템으로는 Alcatel사의 CFF100 터보분자 펌프와 우성진공사의 MVP24 진공로타리펌프를 결합하여 사용하였으며, 진공도측정은 Alcatel사의 ACS1000 장치를 사용하였다. 고진공후 고속 중성입자의 이온화와 에너지 측정을 위한 전하교환기를 설치하였다. 전하교환기로는 진공시스템을 별도로 설치하고 비용이 비교적 많이 드는 기체형 전하교환기 대신 소형화가 가능하고 유지보수가 좋은 고체형 전하교환기 제작하여 실험 하였다. 전하교환기에서 이온화된 고속 중성입자가 전기장이나 자장에 영향을 받았을때 에너지분포를 디텍터를 통해 측정하였다. 즉, 이온화된 중성입자의 에너지가 실리콘 다이오드를 통해 전압 펄스 신호로 변환되고 이차 증폭기를 통해 전압 펄스 신호들이 증폭한다. 에너지 측정을 위한 디텍터는 소형화가 가능하고 비용이 비교적 적게 드는 실리콘 다이오드를 설치하였다. 본 연구결과 중성입자 에너지 분석 장치가 실제 핵융합 장치의 플라즈마 이온온도와 특성 측정에 적용할 수 있으며, 앞으로 개발될 여러 형태의 응용 플라즈마 발생장치의 플라즈마 진단에 이용될 것으로 기대한다.

  • PDF

Asthma Management System Design and Implementation Using PC-based Spirometer (PC-기반 폐활량기를 이용한 천식 관리 시스템 설계 및 구현)

  • Bak, Jong-Cheon;Hwang, Dong-Guk;Lee, Woo-Ram;Jeon, Byeong-Min
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.587-590
    • /
    • 2009
  • 천식환자의 폐활량 측정 및 관리는 정기적으로 검사되어 관리될 필요가 있는 매우 중요한 관리 항목이다. 본 연구는 천식환자의 폐활량을 정기적으로 관리할 수 있도록 PC-기반 폐활량기를 이용한 천식환자의 폐활량 측정 및 관리 시스템의 설계 및 구현에 관한 연구이다. 폐활량 검사는 크게 3종류 구성되며, 본 연구는 노력성 폐활량 검사(Forced Vital Capacity Test)를 1차적으로 설계 및 구현 방법을 제안하였다. FVC 검사의 목적은 폐질환의 진단, 중증도 그리고 치료효과 판정, 기관지 천식의 진단 및 관리, 수술시 마취방식의 결정 등으로 무엇보다 정확한 검사와 정기적인 검사를 필요로 하는 중요한 검사이다. FVC 검사는 검사과정에서 천식환자에게 많은 노력을 필요로 하는 힘든 검사로서 검사자의 도움이 필수적이므로 폐활량 검사 프로그램 개발에 있어 고려되어 알고리즘이 효율적으로 개발되어야 한다. 본 시스템은 휴대형 폐활량기(Spirometer)를 PC에 연결하고, 폐활량을 측정할 수 있도록 구성되었고, 검사 내용은 PC의 DB에 저장하고, 추후에 정기적으로 서버의 DB로 전송함으로서 보다 더 폭넓은 관리를 가능하도록 하며 천식환자는 서버가 제공하는 웹 사이트를 이용함으로서 자신의 건강관리를 가능하도록 구성된다. FVC 검사 프로그램은 정확한 검사와 편리한 사용자 인터페이스를 제공하도록 설계 및 구현하였고 따라서 자체 개발된 폐활량기를 PC-기반 프로그램으로 제어 가능함으로서 추후 다양한 임상실험의 데이터 확보, 기능의 확장과 성능의 개선을 할 수 있고, 좀 더 편리하고, 정확한 폐활량측정이 가능 할 것이다.

  • PDF

A Preliminary Design for Hybrid Building System with Progressive Collapse Prevention Means (연속붕괴가 방지된 초고층 복합빌딩시스템의 예비설계)

  • Choi, Ki-Bong;Cho, Tae-Jun;Kim, Seong-Soo;Lee, Jin-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.48-54
    • /
    • 2015
  • In this study, we propose an innovative lateral force distribution building system between tall buildings by utilizing the difference of moment of inertia, resulting the reduction of lateral displacement and the lateral forces in terms of an alternative for the dense human and increased cost of lands in highly integrated city area. A successive collapse prevention means by providing additional bearing plate between connections is proposed. In addition to that, a more economical vibration reduction is expected due to the suggested tuned mass damper on the surface of spacial structure. In the considered verification examples, reduced drifts at the top location of the building systems are validated against static wind pressure loads and static earthquake loads. The suggested hybrid building system will improve the safety and reliability of the new or existing building system in terms of more than 30% reduced drift and vibration through the development of convergence of tall buildings and spatial structures.