• Title/Summary/Keyword: 자장해석

Search Result 115, Processing Time 0.027 seconds

EMGF Output Analysis Using Inductance Variation Model (인덕턴스 변화 모델을 이용한 EMGF 출력 분석)

  • Kim, Tae-Shin;Sung, In-Mo;Yang, Ji-Hyuk;You, Chun-Yeol;Kwon, Oh-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.1
    • /
    • pp.5-11
    • /
    • 2009
  • The Explosive Magnetic Generator of Frequency (EMGF) has been studied as a method to generate a strong microwave effectively through converting the explosion powder energy into the electromagnetic energy. However, the generated high frequency electromagnetic wave has not been explained clearly yet, for it is known to be difficult to analyze the high frequency electromagnetic wave oscillation using a simple time-varying equivalent circuit model. In this paper, we analyze the problems of the widely used inductance model with an exponential decreasing pattern and investigate the tendency of a more accurate inductance variation model using the finite element method of EMGF inductance by considering the magnetic compression effect. And we have shown via an EMGF output simulation that the new inductance variation model proposed here has an negative effect on EMGF output.

A Study on the Geometric Design Parameters for Optimization of Cooling Device in the Magnetocardiogram System (심자도 장비의 냉각장치 특성 최적화를 위한 기하 설계 변수 연구)

  • Lee, Jung-Hee;Lee, Young-Shin;Lee, Yong-Ho;Lim, Hyun-Kyoon;Lee, Sung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • A magnetocardiogram (MCG) is a recording of the biomagnetic signals generated by cardiac electrical activity. Biomagnetic instruments are based on superconducting quantum interference devices (SQUIDs). A liquid cryogenic Dewar flask was used to maintain the superconductors in a superconducting state at a very low temperature (4 K). In this study, the temperature distribution characteristics of the liquid helium in the Dewar flask was investigated. The Dewar flask used in this study has a 30 L liquid helium capacity with a hold time of 5 d. The Dewar flask has two thermal shields rated at 150 and 40 K. The temperatures measured at the end of the thermal shield and calculated from the computer model were compared. This study attempted to minimize the heat transfer rate of the cryogenic Dewar flask using an optimization method about the geometric variable to find the characteristics for the design geometric variables in terms of the stress distribution of the Dewar flask. For thermal and optimization analysis of the structure, the finite element method code ANSYS 10 was used. The computer model used for the cryogenic Dewar flask was useful to predict the temperature distribution for the area less affected by the thermal radiation.

Performance Comparison of Phase Detectors for the Synchronization Analysis of Electroencephalographic Signal (뇌파신호의 동기해석을 위한 위상검출기의 성능비교)

  • Kim, HyeJin;Lee, JeeEun;Yoo, Sun K.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.277-284
    • /
    • 2013
  • The analysis of phase synchronization characteristics from EEG signals is important for the understanding of information processing functionality in the brain network. In this paper, wavelet transformation(WT), Hilbert tansformation (HT), complex demodulation (CD) methods having time localization characteristics were applied to real evoked potential data and noise added simulation data with center frequencies corresponding to EEG bands for the estimation performance analysis of phase offset, phase changing point, and interband crosstalk. The WT is the best both in ${\delta}$, ${\theta}$, and ${\alpha}$ band signal decomposition, and in analyzing phase synchronization performance. The CD can be efficiently used in changing point detection under tolerant noise condition because of its abrupt performance degradation over noise endurance level. From experimental observations, the WT is the most suitable in phase synchronization application of EEG signal, and the CD can be affordable in restricted application such as changing point detection for higher bands than ${\delta}$. Particularly, WT and CD can be used to detect the changing instant of brain function by indirectly estimating the phase changing point.

Numerical Analysis of Three-Dimensional Magnetic Resonance Current Density Imaging (MRCDI) (3차원 자기공명 전류밀도 영상법의 수치적 해석)

  • B.I. Lee;S.H. Oh;E.J. Woo;G. Khang;S.Y. Lee;M.H. Cho;O. Kwon;J.R. Yoon;J.K. Seo
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.269-279
    • /
    • 2002
  • When we inject a current into an electrically conducting subject such as a human body, voltage and current density distributions are formed inside the subject. The current density within the subject and injection current in the lead wires generate a magnetic field. This magnetic flux density within the subject distorts phase of spin-echo magnetic resonance images. In Magnetic Resonance Current Density Imaging (MRCDI) technique, we obtain internal magnetic flux density images and produce current density images from $\bigtriangledown{\times}B/\mu_\theta$. This internal information is used in Magnetic Resonance Electrical Impedance Tomography (MREIT) where we try to reconstruct a cross-sectional resistivity image of a subject. This paper describes numerical techniques of computing voltage. current density, and magnetic flux density within a subject due to an injection current. We use the Finite Element Method (FEM) and Biot-Savart law to calculate these variables from three-dimensional models with different internal resistivity distributions. The numerical analysis techniques described in this paper are used in the design of MRCDI experiments and also image reconstruction a1gorithms for MREIT.

The Exchange Bias of NiO/NiFe Thin Eilm by the Measurement of Anisotropic Mngnetoresistance (이방성 자기저항측정을 이용한 NiO/NiFe 박막의 교환결합연구)

  • Kim, Jong-Kee;Kim, Sun-Wook;Lee, Ky-Am;Lee, Sang-Suk;Hwang, Do-Guwn
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.4
    • /
    • pp.143-148
    • /
    • 2002
  • We report an experimental evidence of coexistence of the strong and weak exchange couplings in unidirectional NiO/NiFe (antiferromagneticlferromagnetic) bilayer thin films. The exchange bias was measured by VSM and AMR techniques and then, analyzed into the strong and weak exchange couplings by means of a regression method. In NiO(60nm)/NiFe(10nm) film, the ratio of the weak exchange coupling field over the average exchange coupling field was found to be almost unchanged within it range from 0.2 to 0.4 irrespective to the strength of an applied field. However, the ratio increased among the samples with decreasing the average exchange coupling field due to the increment of the weak exchange coupling area.

Fabrication and performance and stability tests of Bi-2223 pancake magnet

  • Sohn, M.H.;Cha, M.K.;Lee, J.K.;Cho, Y.S.;Ha, H.S.;Jang, H.M.;Lee, N.J.;Kim, B.J.;Kim, H.K.;Kim, Y.C.;Jeong, D.Y.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.241-247
    • /
    • 2000
  • 77 K와 self-field에서 22 A 의 Ic 를 갖는 길이 120 m, 19-심 Bi-2223상 선재를 제조하여, 두 개의 double pancake 코일로 구성된 proto-type 고온초전도 자석을 설계, 제작하여 이 자석에서의 4.2 K와 77 K에서의 I-V 특성과 운전 특성을 평가한 결과, 이 자석은 77 K 등온조건에서는 9.5 A 의 Ic를, 77 K 헬륨가스 속에서는 8.3 A 의 Ic를 나타내었고, 4.2 K 등온조건에서는 93.7 A 의 Ic와 102 A 의 Iq를, 4.2K헬륨가스 속에서는 88.4A의 Ic 와 92.0 A 의 Iq를 나타내어, 이 자석은 4.2 K 와 77 K 의 등온조건에서 각각 0.58 T 와 0.06 T 의 자장을 발생하였는데, 이는 해석적 방법으로 계산한 결과와 잘 일치하였다. 그리고 이 자석이 전도냉각되어 4.2 K 에서 운전될 때의 안정성 특성평가로서, Ic 보다 약간 큰 전류인 89 A 를 인가한 결과, 전류인가 후 82.6초 후에 quench가 발생하였는데, 이 quench는 네 번째 pancake의 전류도입선부 연결부에서와 약간 늦지만 첫 번째 pancake의 전류도입선부 연결부에서 거의 동시에 개시되어 전체로 파급된 것으로 사료되었는데, Ic 가 낮은 첫번째 pancake에서 더 높은 전압 강하가 나타났다. 또한 장착된 heater를 통하여 77 K 에서 8.9 A 의 전류로 운전되고 있는 코일에 146 joule 의 열을 가했을 때 quench 가 일어났는데, 이때 quench 는 방위각 방향의 Bi-2223/Ag 선재를 따라서 보다 Kapton 절연층을 관통하는 선재의 반경방향으로 훨씬 빨리 전파하였다.

  • PDF

A New Concept of Magnetic Cable for Safe Mobile Power Delivery (안전한 전력전달을 위한 새로운 형태의 자기케이블)

  • Lee, Woo-Young;Huh, Jin;Choi, Su-Yong;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.542-553
    • /
    • 2011
  • A magnetic cable that can safely deliver high frequency AC electric power in flammable or sensitive workplaces by preventing from arcs and electric shocks is firstly proposed in this paper. Several new magnetic cable structures with magnetic shields, which are composed of such cancel coil, cancel copper plate, and cancel copper pipe, were compactly implemented by considering and analyzing fringe field and thus the parallel leakage flux is drastically reduced. The output power and efficiency of a prototype magnetic cable with 1.5 m length and 5 cm gap were measured as 353.8W and 68%, where the source current and switching frequency were 10 $A_{rms}$ and 20 kHz, respectively. The proposed magnetic cables are fully analyzed and verified by finite-element method (FEM) simulations and experiments. The results are in a good agreement.

Analysis of the Magnetic Field Distribution and the Current Characteristics of Rotating Type Low Tc Superconducting Power Supply (회전자속형 초전도 전원장치의 박막상에서의 2차원 자장분포 및 전류 특성 해석)

  • Sim, Ki-Deok;Kim, Ho-Min;Yoon, Yong-Soo;Chu, Yong;Han, Tae-Su;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.343-345
    • /
    • 1998
  • By computer simulation, the pattern of magnetic field distribution on the Nb-foil of a rotating flux type superconducting power supply has been calculated. Using the results, the current pumping rate has been calculated and compared with the results obtained by the experiment. The experiment has been executed with small-size flux-rump in the environment of LN2 and LHe in order to compare the pattern of magnetic filed in the superconducting state and in the normal state. Five hall-sensor was located on the center, right side, left-side, upper side, lower side of the Nb-foil in order to obtain more accurate pattern of the magnetic field generated by rotating pole. In the simulation, the effects of the excitation-magnet and the iron core located at the inner-side and circumference of the magnet have been considered. By comparing the data from the experiment and the results from the simulation, the size of normal spot estimated. At the same time, by calculating the linkage flux, the current-pumping-rate has been obtained. Consequently, the results obtained from experiment and simulation coincided as expected.

  • PDF

Modeling of a linear GMR Isolator Utilizing Spin Valves (스핀밸브를 이용한 선형 GMR 아이솔레이터의 모델링)

  • Park, S.;Jo, S.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.232-235
    • /
    • 2004
  • Linear GMR isolator which is profitable for transmitting analog signal was modeled and the output voltage and current in relation to the input current were investigated. GMR isolator modeling was divided into two parts, namely magnetic and electric parts. The flow chart of the modeling was drawn in which the MR curve of the spin valves were incorporated to obtain the electrical voltage output. For magnetic modeling, 3-dimensional model of planar coil was analyzed by FEM method to obtain the magnetic field strength corresponding to the input current. Coil efficiency of the planar coil having magnetic core layer was shown to have about 1.5 times larger than that of the coil without the magnetic core layer. The feedback coil current(output current) corresponding to the input coil current was calculated to be within ${\pm}$0.25 mA of the linear fitting function of I$\_$out/= I$\_$in/-5 mA. Also, the response time and output waveforms were obtained when the coil current was a rectangular waveform. The rise time and fall time was 6 ${\mu}\textrm{s}$, respectively when the slew rate of the op-amp was 0.3 V/${\mu}\textrm{s}$.

Simulation Analysis of Spatially Arterial Pulse Wave using Two-dimensional Array Sensors with Magnetoresistive Device (2차원 배열 자기저항소자를 이용한 공간 맥진파형의 전산모사 분석)

  • Kim, M.S.;Kim, S.W.;Kim, G.W.;Lee, S.J.;Lee, S.G.;Lee, H.S.;Park, D.H.;Hwang, D.G.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.307-310
    • /
    • 2005
  • To get the spatial feature of arterial pulse, we designed spatial pulse diagnostic apparatus (SPDA) using a 2-dimensional magnetoresistive sensor array. The magnetic field distribution fur magnet may was simulated using finite element method. We recognized that the field distribution of parallel magnet mays was more sensitive and uniformed than that of perpendicular one. Also the spatial displacements of magnet array were agreed with the output signal of magnetic tunnel junction (MTJ) sensor array.