• Title/Summary/Keyword: 자장분포

Search Result 83, Processing Time 0.022 seconds

The Exchange Bias of NiO/NiFe Thin Eilm by the Measurement of Anisotropic Mngnetoresistance (이방성 자기저항측정을 이용한 NiO/NiFe 박막의 교환결합연구)

  • Kim, Jong-Kee;Kim, Sun-Wook;Lee, Ky-Am;Lee, Sang-Suk;Hwang, Do-Guwn
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.4
    • /
    • pp.143-148
    • /
    • 2002
  • We report an experimental evidence of coexistence of the strong and weak exchange couplings in unidirectional NiO/NiFe (antiferromagneticlferromagnetic) bilayer thin films. The exchange bias was measured by VSM and AMR techniques and then, analyzed into the strong and weak exchange couplings by means of a regression method. In NiO(60nm)/NiFe(10nm) film, the ratio of the weak exchange coupling field over the average exchange coupling field was found to be almost unchanged within it range from 0.2 to 0.4 irrespective to the strength of an applied field. However, the ratio increased among the samples with decreasing the average exchange coupling field due to the increment of the weak exchange coupling area.

실리콘 다이오드를 적용한 다채널 중성 입자 분석기 개발

  • Cheon, Se-Min;Jwa, Sang-Beom;Gang, In-Je;Lee, Heon-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.211-212
    • /
    • 2011
  • 플라즈마를 제어하기 위해서는 플라즈마의 온도, 밀도, 에너지 분포등과 같은 플라즈마의 특성을 정확히 측정할 수 있어야한다. 핵융합발전에서는 플라즈마를 발생하기 위하여 플라즈마의 온도, 밀도 등 각종 변수들을 시공간적으로 계측, 분석할 수 있는 진달설비를 사용하고 있으며, 정확한 플라즈마 제어와 측정을 위한 새로운 진단기술을 개발하고 있다. 그리고 중요한 변수중에 하나인 플라즈마 이온온도를 측정하기 위해 중성입자 검출법이 잘 알려져 있다. 이 실험은 수소 중성입자가 토카막 내부의 플라즈마 이온과 충돌하면서 생성된 고속 중성입자의 에너지를 분석하는 실험이다. 본 연구의 실험방법은 수소 중성입자를 이온빔 장치에서 이온화 시킨 후 자체 제작한 가속기를 통하여 가속시켜 에너지 특성을 분석을 하는 것이다. 본 연구의 실험장치로 에너지 교정용 100 keV 이온빔 소스를 제작 하였고 이온빔 장치 내부에 수소기체를 주입하고 기체방전을 일으켜 플라즈마를 발생시켰다. 이온빔 외부에는 팬을 설치하고 전도성이 강한 물 대신 전도성이 약한 오일을 사용하여 냉각 하였다. 이온빔 장치와 결합될 이온 가속장치는 지름 300 mm, 두께 2 mm의 원형 구리판을 여러층으로 쌓아 전극으로 제작하였고 전극과 전극 사이에서 코로나 방전과 스파크를 방지하기 위해 전극 둘레에 코로나링을 설치 하였다. 또한 전극 사이마다 1G${\Omega}$의 저항을 설치한 후 고전압을 생성하여 이온 가속 효율을 증대시켰다. 진공시스템으로는 Alcatel사의 CFF100 터보분자 펌프와 우성진공사의 MVP24 진공로타리펌프를 결합하여 사용하였으며, 진공도측정은 Alcatel사의 ACS1000 장치를 사용하였다. 고진공후 고속 중성입자의 이온화와 에너지 측정을 위한 전하교환기를 설치하였다. 전하교환기로는 진공시스템을 별도로 설치하고 비용이 비교적 많이 드는 기체형 전하교환기 대신 소형화가 가능하고 유지보수가 좋은 고체형 전하교환기 제작하여 실험 하였다. 전하교환기에서 이온화된 고속 중성입자가 전기장이나 자장에 영향을 받았을때 에너지분포를 디텍터를 통해 측정하였다. 즉, 이온화된 중성입자의 에너지가 실리콘 다이오드를 통해 전압 펄스 신호로 변환되고 이차 증폭기를 통해 전압 펄스 신호들이 증폭한다. 에너지 측정을 위한 디텍터는 소형화가 가능하고 비용이 비교적 적게 드는 실리콘 다이오드를 설치하였다. 본 연구결과 중성입자 에너지 분석 장치가 실제 핵융합 장치의 플라즈마 이온온도와 특성 측정에 적용할 수 있으며, 앞으로 개발될 여러 형태의 응용 플라즈마 발생장치의 플라즈마 진단에 이용될 것으로 기대한다.

  • PDF

Fabrication of 13Cr-1.5Nb-Fe Alloy Powder and AC Magnetic Properties of the Sintered Magnetic Core (소결 13Cr-1.5Nb-Fe 합금의 교류 자기 특성)

  • 오환수;김택기;조용수
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.11-15
    • /
    • 2000
  • 13Cr-1.5Nb-Fe alloy powder prepared by water atomizing method is reduced with flowing hydrogen gas. The characteristics of a reduced alloy powder is investigated and magnetic cores formed by using the reduction power sintered in the vacuum of ∼10$\^$-5/ Torr. In order to study on the magnetic cores permeability and power loss in alternating magnetic field are also measured. The result of particle size distribution shows the paticle size is 70 ㎛ at volume fraction of 50 %. The saturation magnetization of the reduced alloy powder is 160 emu/g. The relative peak permeability (H$\_$a/=5Oe) of a magnetic core is 400 and the power loss (B$\_$m/=80G) 0.12 mW/cc at sintering temperature of 1,200 $\^{C}$, 10 ton/㎠ forming pressure, and 1 kHz.

  • PDF

Growth and Characterization of Epitaxial YIG Films for Microwave Devices (마이크로파 소자용 에피틱시 YIG막의 성장과 특성)

  • 김덕실;조재경
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.2
    • /
    • pp.91-97
    • /
    • 1999
  • YIG $(Y_3Fe_5O_{12})$ films with 4~80 ${\mu}{\textrm}{m}$ thickness were epitaxially grown on GGG $(Gd_3Ga_5O_{12})$ substrates by LPE (liquid phase epitaxy) techniques. Using various melts having different chemical composition the growth temperature was varied as a parameter. Growth rate, surface morphology, chemical composition, lattice constant, saturation magnetization, and magnetic resonance of the films were investigated. Lattice mismatch between the substrate and film Δa, saturation magnetization, and magnetic resonance line width ΔH increased, decreased, and increased, respectively, as undercooling temperature ΔT increased. The films grown by using the melt with larger R$_1$and smaller R$_3$had smaller ΔH. The major origin of the increase of ΔH was the increase of Δa. It is considered that the magnetic field in the film became locally inhomogeneous with the increase of Δa due to the increase of inhomogenity in stress distribution to the film depth direction. Therefore, in order to grow YIG films with small microwave loss it is necessary to grow films at small ΔT using the melt with large R$_1$and small R$_3$resulting in a small Δa.

  • PDF

MRI Enhancement using Perovskite Material for B1 Field Control at 7T (7T MRI에서 B1 필드 조정을 위해 페로브스카이트 재료를 이용한 자기공명영상 향상)

  • Kim, Yong-Tae;Kim, Joo-Yeon;Baek, Hyeon-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.565-573
    • /
    • 2021
  • The spatial distribution of electromagnetic fields in the human body can be adjusted by using high dielectric materials. This method has a complementary compared to other methods. However, it can be used as a powerful dielectric shimming tool in certain applications. It can be manufactured in a geometrically free shape and a pad manufactured according to the purpose can be applied without any change of the system. Especially in ultrahigh magnetic field (UHF) MRI, the clinical high dielectric pad used to increase the intensity of the transmit (B1+) and receive (B1-) fields, which has low sensitivity due to the high operating frequency, has great potential. In addition, there are few studies applied to UHF MRI. Therefore, in this study, a high dielectric material pad made of calcium titanate suspension was developed in the laboratory. And the signal increase of clinically useful images was confirmed in various protocols of UHF 7T MRI.

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

Evaluation of Articular Cartilage using 3D FFE-PROSET Technique in 3.0 T Knee MR Imaging : Comparison with 2D TSE - SPIR Technique (3.0T 무릎자기공명영상에서 3차원 FFE-PROSET 기법을 이용한 관절연골평가 : 2차원 TSE-SPIR 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.599-606
    • /
    • 2013
  • The purpose of this study is to know a clinical usefulness for delineation of articular cartilage compared with 2D TSE-SPIR and 3D FFE-PROSET technique. From January 2013 to september 2013, a total of 30 normal volunteers(12 men and 18 women aged between 35 and 55 years; mean 49.48 years) were studied on a philips 3.0T MRI scanner. As a quantitative analysis, SNRs and CNRs were evaluated by using two methods for delineation of articular cartilage. As a qualitative analysis, image quality was evaluated by special radiological technologist of MRI for image delineation on a three grade. As a results, SNRs and CNRs for articular cartilage were significantly greater for the 3D FFE-PROSET(SNRs: 8.40, 114.02, 9.53, CNRs: 104.49, 139.49) technique compared to 2D TSE-SPIR(SNRs: 4.41, 71.63, 7.34, CNRs: 64.30, 58.41) technique, image quality also was higher for evaluation of 3D FFE-PROSET(2.40) technique(p=0.0021). In conclusion, this study showed that a 3D FFE-PROSET MRI has improved SNRs and CNRs for evaluating of the articular cartilage, these conclusions in the future will be provided useful information in diagnosis of articular cartilage.

Characteristics of Open-Loop Current Sensor with Temperature Compensation Circuit (온도보상회로를 부착한 개방형 전류측정기의 특성)

  • Ku, Myung-Hwan;Park, Ju-Gyeong;Cha, Guee-Soo;Kim, Dong-Hui;Choi, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8306-8313
    • /
    • 2015
  • Open-type current sensors have been commonly used for DC motor controller, AC variable controller and Uninterruptible Power Supply. Recently they have begun to be used more widely, as the growth of renewable energy and smart-grid in power system. Considering most of the open-type current sensors are imported, developing the core technology needed to produce open-type current sensors is required. This paper describes the development and test results of open-type current sensors. Design of C type magnetic core, selection and test of a Hall sensor, design of current source circuit and signal conditioning circuit are described. 100A class DIP(Dual In-line Package) type and SMD(Surface Mount Devide) type open-type current sensors was made and tested. Test results show that the developed open-type current sensor satisfies the accuracy requirement of 2% and linearity requirement of 2% at 100 A of DC and AC current of 60Hz. Temperature compensation was carried out by using a temperature compensation circuit with NTC(Negative Temperature Coefficient) thermistor and the effect of the temperature compensation are described.

남해 동부 연안 지역 지하수의 수리지구화학적 연구: 해수침투에 대한 고찰

  • 신광섭;윤성택;허철호;이상규
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.438-441
    • /
    • 2003
  • 남해 동부 연안 지역 지하수의 해수 침투 영향을 광역적으로 파악하기 위하여, 202개소의 지하수 시료를 채취하고 수리지구화학적 연구를 수행하였다. 전체 시료 중 14.4%가 500 $\mu\textrm{m}$/cm을 초과하는 높은 EC값을 나타내어 해수 영향을 시사해 주었다. 해수 영향 판단의 또 다른 파라메터로 사용되는 CI/HCO$_3$ 몰비는 전체 시료의 23.3%가 1.3 이상의 값을 나타내었다. 한편, 대표적으로 해수침투 영향 및 인위적 오염의 영향을 각각 반영하는 것으로 알려진 Cl과 NO$_3$의 농도에 관한 누적도수분포도를 작성하여 배경수질군과 오염영향군을 구분짓는 배경치(background concentration)를 구한 결과, 각각 Cl = 22.3 mg/1 및 NO$_3$= 23.1 mg/l로 나타났다. 이 두 파라메터의 농도 분포를 기준으로 하여 채취된 지하수 시료를 크게 4개의 그룹으로 나눌 수 있었다. 그 결과, 자연적 또는 인위적 기원의 오염이 배제된 그룹 1은 전체 시료의 31%, 자연적 오염(해수 영향)을 반영하는 그룹 2는 전체의 24%, 인위적 오염의 영향을 반영하는 그룹 3은 전체의 9%, 해수 영향 및 인위적 오염을 동시에 반영하는 그룹4는 전체의 36%로 나타났다. 또한 그룹2와 그룹4는 대부분 Na-Cl유형으로 진화하는 Ca-Cl유형을 나타내었다. 따라서, 여러 지구화학 방법에 의한 해수 영향 판단 결과는 서로 잘 일치하고 있음을 알 수 있다. 결국, 지구화학적 파라메터를 종합적으로 활용함으로써, 연안 지역 해수침투의 효과적인 파악은 물론 예측 및 방지, 복구에 효과적으로 사용될 수 있을 것으로 판단된다.으로 토양에서 유동 가능성이 있는 중금속만을 추출하였다. 분석실험은 토양의 Cd2+ 와 Pb2+를 대상으로 행하여졌으며, 여러 토양에서 추출 분석한 결과를 EDTA분석결과와 비교하였다. 실험결과, 중금속은 매우 신속하게 고분자 자성체와 결합하였고, 그 후 자성체를 외부 자장으로 모은 후 산으로 용해시키고, 결합된 중금속은 Graphite furnace AAS로 분석함으로써 빠르고 효율적으로 분석실험을 수행할 수 있음을 알 수 있었다. 한편, 실험에서 나타난 수치들을 비교 검토한 결과 토양 분석시 sandy soil에서는 자성체를 이용한 분석이 EDTA에 의한 방법보다 더 높은 추출도를 보인 반면, silt 함량이 많은 토양의 경우에서 EDTA분석에서 더 높은 중금속 추출도를 보였다.s 중에서 490nm와 555nm의 복합밴드를 포함하는 OC2 알고리즘(ocean color chlorophyll 2 algorithm)을 사용하는 것이 OC2 series 및 OC4 알고리즘보다 좋은 추정 값을 도출할 수 있을 것으로 기대된다.환경에서는 5일에서 7월에 주로 이 충체의 유충이 발육되고 전파되는 것으로 추측되었다.러 가지 방법들을 적극 적용하여 금후 검토해볼 필요가 있을 것이다.잡은 전혀 삭과가 형성되지 않았다. 이 결과는 종간 교잡종을 자방친으로 하고 그 자방친의 화분친을 사용할 때만 교잡이 이루어지고 있음을 나타내고 있다. 따라서 여교잡을 통한 종간잡종 품종육성 활용방안을 금후 적극 확대 검토해야 할 것이다하였다.함을 보이고 있다.X> , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어

  • PDF