• Title/Summary/Keyword: 자외선살균조사

Search Result 51, Processing Time 0.031 seconds

A Study of Antibacterial Efficiency according to Direction of UV Irradiation in Cosmetic Case

  • Jeong, Jae Young;Hwang, You Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.2
    • /
    • pp.119-124
    • /
    • 2021
  • In this study, we propose an antibacterial efficiency according to the direction of UV irradiation. In the experiment, we measured the effective irradiation angle of UVC using S.aureus, a Gram-positive bacterium, and the variation of the antibacterial region according to the distance according to the direction of ultraviolet irradiation. Also, as a method to increase the antibacterial efficiency during horizontal irradiation of ultraviolet rays, we tested reflecting leaking UVC. As a result, the angle of ultraviolet irradiation was measured smaller than the product description, and in the case of the antibacterial area according to the direction of ultraviolet irradiation, the distance from the sample was increased during vertical irradiation, and the antibacterial area was increased as the distance from the sample was closer during horizontal irradiation. In addition, it was confirmed that antibacterial efficiency can be increased by reflecting leaking UVC during horizontal irradiation of UVC.

Development of an UV Distribution Model for the Design of a Submerged UV Disinfection Reactor and Its Application (침지형 자외선 살균조 설계를 위한 자외선 분포 모델의 개발 및 적용)

  • Park, Changyeun;Kim, Sunghong;Choi, Younggyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.505-512
    • /
    • 2021
  • A 3D model was developed to calculate the UV intensity of a submerged-type UV disinfection reactor. Numerical experiments were conducted by inputting the design factors of an open channel-type disinfection reactor and a pipe-type disinfection reactor that were installed in an actual sewage treatment plant. The following data were obtained: The average UV intensity of the installed open channel-type reactor and pipe-type reactor was 7.87 mW/cm2 and 13.09 mW/cm2, respectively; the UV dose reflecting the UV irradiation time and taking into account attenuation effects such as mixing imbalance, lamp aging, temperature, and fouling, was expected to be 21.1 mJ/cm2 and 24.8 mJ/cm2, respectively, and these values are 5 % and 24 % higher than the target UV dose of 20 mJ/cm2, respectively. By using the UV3D model, the optimal lamp position, which maximizes the average UV intensity without changing the size of the disinfection reactor or lamp output power, can be found. In this case, by only adjusting the lamp position, the average UV intensity can be increased by 0.9 % for the open channel-type and 0.5 % for the pipe-type, respectively. A better average UV intensity can be obtained by model simulation. By adjusting the horizontal and vertical ratio of the open channel-type reactor and by moving the lamp position, the average UV intensity can be increased by 7.4 % more than the present case.

Ultraviolet Inactivation of Escherichia coli in Stainless Steel Cups (스테인리스스틸 컵 내 Escherichia coli의 자외선 살균)

  • Mok, Chulkyoon;Lee, Nam-Hoon
    • Food Engineering Progress
    • /
    • v.13 no.2
    • /
    • pp.122-129
    • /
    • 2009
  • Ultraviolet (UV) is widely used as a sterilizing agent in restaurants and catering facilities in Korea. Efficacy of UV sterilizers (UVS) was investigated against E. coli on the inner bottom of stainless steel cups. UV intensity on the bottom of cups varied widely with the locations of cups in UVS, showing higher values at center while lower values at outskirts. The deviations in UV intensity were remarkable on top shelf, but alleviated as proceeded to middle and bottom shelves. Inactivation of E. coli was proportional to the UV intensity and treatment time, consequently to UV dose, and showed a pseudo-first-order kinetics with tailing. Initial inactivation rate constants ($K_{1}$) deviated with the locations of the cups, while final inactivation rate constants ($K_{2}$) showed comparable values. An equation for the calculation of the proposed UV treatment time was suggested.

Simulation Method for the Flowing Water Purification with UV Lamp (자외선램프을 이용한 유수처리장치 설계 시뮬레이션)

  • Jeong, Byeong-Ho;Lee, Kang-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.17-23
    • /
    • 2009
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. The CFD model was also used to evaluate disinfection efficiency in alternative reactor designs. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. In this paper, it describe the how to design optimal ultraviolet disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

Distribution of Ultraviolet Intensity and UV Leaking of Commercial UV Sterilizers Used in Restaurants (음식점에서 사용하는 자외선 살균소독기 내 자외선 강도 분포 및 자외선 누출)

  • Mok, Chul-Kyoon;Lee, Nam-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.228-233
    • /
    • 2008
  • Ultraviolet sterilizers (UVS) are widely used in restaurants, cafeterias and catering businesses in Korea. The proper application of UVS, however, is still questionable since no studies have clearly identified their efficacy and safety, while regulations and regulatory management systems are yet to be established. In the present study, the efficacy of UVS were investigated by measuring spatial UV intensity inside five commercially operated UVS. The operating safety parameters were also checked by measuring leaked UV intensity. The UV intensities were inversely proportional to distance from the UV lamp within 25 cm, and to the square of the distance exceeding 25 cm. The UV intensities in commercial UVS varied with the distance from UV lamp and the incident angle, highlighting efficacy and stability concerns. Notable leakage was detected through the door gaps of a studied UVS, which also brought about safety concerns. Allowable working distances for the UV leaking UVS were suggested based on international standards.

Synthesis of Macroporous TiO2 Microparticles for Anti-Bactericidal Application (거대 기공을 갖는 다공질 TiO2 분말의 살균 효과)

  • Roh, Seong Hoon;Kim, Jeong Keun;Cho, Young-Sang
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.524-535
    • /
    • 2018
  • In this study, macroporous titania powders were synthesized utilizing the emulsion-assisted self-assembly to apply the removal of B. subtilis under UV irradiation, and the results were compared with the bactericidal effect of commercial titania nanoparticles. By changing the pore size of the porous titania powder, the reduction of B. subtilis by photocatalytic effect was measured, and the bactericidal capacity of the porous particles according to the pore size was compared in order to derive the optimum condition of the sterilization experiment. It was observed that the sterilization effect increased as the pore size became smaller, and it was confirmed that more than 50% of B. subtilis cold be removed for 1 hour of UV irradiation. Also, in order to promote the generation of active chemical species, a diluted solution of hydrogen peroxide was combined with the photocatalytic sterilization method, resulting in the removal of most of the strain after ultraviolet irradiation for 1 hour.

Effects of UV Sterilization on Quality of Acer mono Sap (자외선 살균이 고로쇠 수액의 품질에 미치는 영향)

  • Choe, Su Bin;Han, Sang Jin;Han, Ouk Hee;Kim, Hak Su;Kang, Sung Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.1
    • /
    • pp.148-152
    • /
    • 2013
  • An ultraviolet (UV) sterilization system was developed to decrease the number of microorganisms in filtered Acer mono sap (FAS). The Acer mono sap (AS) was passed through 18 strips of PTA fluoroplastic tubing with 30 UV lamps (total 1,170 W). During passage, the AS was effectively exposed to the UV rays. The total bacteria, coliform group and fungi were sterilized at a flow rate ranging from 852 to 1,358 mL/min and a UV power higher than 156 W. Although the sensory score of the UV-sterilized AS was significantly lower than that of the untreated AS, the sensory score was better under the condition of 390 W and 852~1,358 mL/min than under the other conditions examined. ANOVA did not reveal a significant difference in pH, total acidity, sugar content and color characteristic under all conditions tested (p<0.05). Considering the overall attributes of the AS quality, the optimum sterilization condition was determined to be 390 W and 852~1,358 mL/min.

Survey of Preservatives and UV Filter Ingredients of Distributed Sunblock Products in Korea (국내 유통 자외선 차단 기능성화장품 중 살균보존제 및 자외선차단성분 사용실태조사)

  • Park, Jeong Hee;Kim, Jong Pil;Kim, Jin A;Seo, Kye Won;Kim, Eun Sun;Seo, Jumg Mi
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.4
    • /
    • pp.381-390
    • /
    • 2017
  • This study was conducted to determine 16 preservatives and 18 UV filter ingredients levels in 100 sunblock products. The order of detection rates of preservatives was phenoxyethanol (n=61), benzoic acid (n=19), methyl paraben (n=11), benzyl alcohol (n=8), propyl paraben (n=7). Also the order of detection rates of UV filter ingredients was titanium dioxide (n=81), ethylhexyl methoxycinnamate (n=69), zinc oxide (n=48), ethylhexyl salicylate (n=48), bis-ethylhexyloxyphenol methoxyphenyltriazine (n=44). The content of the detected preservatives and UV filter ingredients was within maximum allowed amount established by KFDA. In addition, preservatives and UV filter ingredients, which were not labeled in the products, were detected in 31 and 2 products respectively.

Development of UV sterilizer for tissues for human skin contact (UV lamp를 사용한 피부 접촉용 지류 살균기 개발)

  • Kim, Seung-Jun;Choe, Ji-Seong;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.248-249
    • /
    • 2009
  • 자외선 램프를 이용한 살균기는 고전압 방전과 달리 오존의 발생을 최소화 하면서 짧은 시간에 원하는 물체를 살균할 수 있는 장점이 있다. 본 연구에서는 인체의 피부에 직접 접촉하는 티슈들의 포장 상태에서 세균의 밀도를 조사하고 그 결과 살균이 필요한 수준이라는 것을 파악한 다음, 공중 화장실용 공동 티슈 공급기에 적합한 살균기를 설계, 제작하고 그 효과를 세균 배양 실험을 통하여 확인하였다.

  • PDF

Microbial reduction effect of steam heating, UV irradiation, and gamma irradiation on red pepper powder (스팀 가열 및 자외선, 감마선 조사 처리에 따른 고춧가루의 미생물 저감화 효과)

  • Choi, Jun-Bong;Cheon, Hee Soon;Chung, Myong-Soo;Cho, Won-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.2
    • /
    • pp.177-182
    • /
    • 2020
  • This study evaluated the effect of steam heating, gamma irradiation, and ultraviolet (UV) irradiation on microorganism reduction in order to determine an effective sterilization method for red pepper powder. The effect of each treatment on the reduction of thermoduric bacteria and total aerobic bacteria in red pepper powder were as follows: 10 kGy gamma irradiation, reduction of 4 log and 6 log CFU/g, respectively; 12 mW/㎠ UV irradiation (264 nm UV-C), reduction of less than 1 log CFU/g; steam heating at 120℃ for 40 s, reduction of approximately 2 log CFU/g. High-temperature short-time processing at 110℃ for 30 s reduced the total bacterial count in Gochujang solution from 5.70 log CFU/g to 2.26 log CFU/g; at 121℃, the solution was commercially sterile. Steam heating resulted in 1, 2, and 4 log microbial inactivation in garlic, onion, and pepper powder, respectively. Steam sterilization, which consumers prefer over other methods, may be an effective method for reducing microorganisms in spice powders, including those in red pepper powder.