• Title/Summary/Keyword: 자연전위측정

Search Result 47, Processing Time 0.025 seconds

Comparison of the Ion Adsorption Method, Potentiometric Titraion and Backtitration Technique for Surface Charge measurement in Ultisol, Alfisol, and Inceptisol (Ultisol과 Alfisol 및 Inceptisol 토양에서 토양표면전하 측정에 사용된 이온흡착법, 전위차 적정법 및 역적정법간의 비교)

  • Lee, Sang-Eun;Neue, Heins Ulitz;Park, Jun-Kyu;Lim, Sookil H.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.3
    • /
    • pp.160-171
    • /
    • 1993
  • Surface charge characteristics of Ultisol(Luisiana soil from Philippines), Alfisol(Maahas soil from Philippines), and Inceptisol(Yongii soil from Korea) were studied by way of potentiometric titration, backtitration technique, and ion adsorption method(or CEC - AEC method). The PZNC(point of zero net charge) values determined by ion adsorption method were much lower than the natural pHs in all soils, indicating that all soil samples bore net negative surface charge. The PZSE (point of zero salt effect) values determined by potentiometric titration and backtitration technique were identical in Luisiana and Yongii soils but not in Maaghas soil. All soils showed higher PZSE values than PZNC values probably due to the influence of permanent negative charge. The permanent charge calculated by the theory of Uehara and Gillman (1980) occupied quite low portion of the CEC measured at pH 7 in all soils. Backtitration technique corrected errors of potentiometric titration at extreme pH. However, it still overestimate the surface charge compared with ion adsorption method. Therefore, the ion adsorption method was recommanded for the surface charge measurement of the usual soils which have high negative charge components.

  • PDF

A Study on Corrosion Potential of Cracked Concrete Beam According to Corrosion Resistance Assessment (부식 저항성 평가에 따른 균열 콘크리트 보의 부식전위 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.97-105
    • /
    • 2009
  • Development and use of blended cement concrete is gaining more importance in the construction industry with reference to durability mainly due to the pore refinement and reduction in permeability. Cracks play a major role on important parameters like permeability, rate of chloride ingress, compressive strength and thus affect the reinforcement corrosion protection. Furthermore, when a crack occurs in the cover concrete, the corrosion of the steel reinforcement may be accelerated because the deterioration causing factors can pass through the crack. In recent years the effect of cracking on the penetration of concrete has been the subject of numerous investigations. Therefore assessing the service life using blended concrete becomes obviously in considering the durability. In the present study, the corrosion assessment of composite concrete beams with and without crack with of 0.3mm using OPC, 30% PFA, 60% GGBS, 10% SF was performed using half cell potential measurement, galvanic potential measurement, mass loss of steel over a period of 60days under marine environmental conditions and the results were discussed in detail.

자연전위의 효율적 측정을 위한 전극의 잡음요소 분석

  • Song, Seong-Ho;Gwon, Byeong-Du
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.1
    • /
    • pp.9-18
    • /
    • 2002
  • We performed a long-term monitoring of self-potential(SP) using the Cu-CuSO₄non-polarizable electrode and copper-clad electrodes(CCE) in a test site in order to analyze the effects of surrounding environmental noises such as temperature, rainfall and soil moisture content on the electrodes. Analysis of the temperature dependence of the non-polarizable electrodes showed that is temperature coefficient was about +0.5 mV/°Fwhen its end was exposed to atmosphere while it was less than +0.5 mV/℃ when submerged into the subsurface, which reflects that there exists an 8 to 11 hour lag between temperatures at the depth of 15 cm and atmosphere. CCE was independent of atmospheric temperature in subsurface but showed temperature coefficient of 1.0 mV/℃ when exposed to atmosphere. Drifts of 1 to 2 mV recorded with the non-polarizable electrode directly related to the soil moisture content when it was buried in subsurface. Drift with CCE also showed similar trend to the soil moisture content, and 5 mV drift was recorded according to 5% of daily variation. The soil moisture content had strong effects on the measurement with CCE in rainfall since the flow potential is generated on the surface of the electrode.

  • PDF

Geophysical surveys for delineation of leachate flows from AMD and buried rock wastes in Kwangyang abandoned mine (광양 폐광산의 산성광산배수의 유동경로 및 폐광석 탐지를 위한 지구물리탐사)

  • 김지수;한수형;윤왕중;김대화;이경주;최상훈;이평구
    • Economic and Environmental Geology
    • /
    • v.36 no.2
    • /
    • pp.123-131
    • /
    • 2003
  • Geophysical surveys(electrical resistivity, self-potential, seismic refraction, GPR) were conducted to investigate the physical properties of the subsurface, and to delineate the flow channel of leachate from a AMD(acid mine drainage), buried rock wastes and tailings, and drainage pipes at an abandoned mine(Kwangyang mine). Especially in rainy season the sites appear to be abundant in AMD leachate, characterized by electrical conductivities of 0.98-1.10 ms/S. Electrical resistivity sections indicate that the leachate flows running in two directions at southern part rise up through the narrow fracture zones at the central part and contaminates the surrounding soil and stream. Such schematic features at the anomalous zone are well correlated with negative peaks in self-potential data, the limited penetration depth in GPR data and low velocity zone in seismic refraction data. Shallow high-resistivity zone is associated with the buried rock wastes which cause the diffractions in GPR image. In addition, the events at depth of approximately 1-1.25 m in GPR sections must be the metal pipes through which AMD is drained off to the inner bay.

Applicability of Geophysical Prospecting for water leakage detection in water utilization facilities (수리시설물의 누수탐지를 위한 물리탐사의 적용성)

  • Park Sam-Gyu;Song Sung-Ho;Choi Jong-hak;Choi Bo-Gyu;Lee Byoung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.179-195
    • /
    • 2002
  • This paper examined the applicability of geophysical prospecting for water leakage detection of the water utilization facilities. Electrical resistivity survey and spontaneous-potential survey were carried out for the water leakage detection of dike and embankment, and the applicability was confirmed from many case studies. However, in order to efficiently maintain and detection of the more accurate water points in the embankment, the efficiently maintain and detection of the more accurate water leakage points in the embankment, the requirements are as follows; 1) It is necessary to use the electrical resistivity survey jointly with the spontaneous-potential survey in order to improve the reliability of water leakage information. 2) It is important to understand physical properties of the soil which influences the electrical resistivity of embankment in order to accurately grasp the water leakage points from the result of the electrical resistivity survey. 3) It is necessary to introduce the three-dimensional prospecting in order to improve the reliability of the measured value. 4) Introductions of the monitoring measurement system are necessary in order to efficiently and economically maintain of the water utilization facilities.

  • PDF

Anti-Corrosion Property of Geopolymer Evaluated by an Impressed Current Cathodic Protection Method, Exposed to Marine Environment (염해환경에서 외부전원법에 의한 지오폴리머 시험체 보강철근의 방식특성 평가)

  • Lee, Hae-Seung;Cho, Ggu-Hwan;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.397-405
    • /
    • 2014
  • There are many literatures reporting that the service life of re-bars in concrete structures is reduced in the oceanic environment due to chloride attack. To solve this problem, this study used geo-polymer as a mix material for concrete to increase its resistance to salt damage, and the external voltage method, one of the electric methods, is was applied to evaluate the likelihood of re-bars in the oceanic structure being exposed to the extreme salt environment. The items evaluated include the natural potential of re-bars and the corrosion rate. The results of the tests showed that in all of the salt environmental conditions (submerged zone, tidal zone, and crack), the tested materials were remarkably effective compared with ordinary concrete. The corrosion protective property was found not only in the evaluation of the natural potential but also in the evaluation of the corrosion rate, suggesting that the external voltage method can be used stably for geo-polymer RC structures in an extreme salt environment.

Electrochemical characteristics of WC-27NiCr and WC-10Co4Cr coated Al bronze (WC-27NiCr과 WC-10Co4Cr로 코팅된 동합금의 전기화학적 특성)

  • Kim, Min-Seong;Park, Jae-Cheol;Jang, Seok-Gi;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.80-80
    • /
    • 2011
  • 세계 기후 변화와 불안정한 유가 변화에 대응하고 국내산업의 저탄소 녹색성장을 위해 신재생에너지 개발이 활발하게 이루어지고 있다. 해양에너지 중에서 조류발전은 대규모 댐을 건설할 필요가 없어 비용이 적게 소요되고 특히 날씨 변화나 계절에 관계가 없고, 발전량이 예측 가능하므로 신뢰성 있는 에너지원으로 적용이 가능하다. 조류발전기 블레이드에 폴리머계 복합재료와 스테인리스강이 대부분인데, 이 재료는 특정 회사에서만 제작 가능하며, 충격에 약하고, 균열전파 속도가 빠르며, 대단히 고가이며, 수입에 의존하고 있는 실정이다. 이러한 조류발전에 사용되는 블레이드는 가혹한 부식, 캐비테이션 그리고 침식환경에 노출되어 있어 내구성이 우수한 제품개발이 대단히 중요하며, 조류발전 블레이드를 동합금으로 제작시, 내식성이 뛰어나며 구리의 특성상 해양생물 서식을 방지할 수 있고, 내캐비테이션 특성, 내구성, 가공성 및 유지보수가 용이한 장점이 있다. 이러한 동합금에 WC-27NiCr와 WC-10Co4Cr를 초고속 화염용사(HVOF)를 이용하여 코팅층의 캐비테이션 특성 및 전기화학적 거동을 연구하였다. 본 연구에서는 조류발전용 블레이드의 재료로 사용하려는 동합금에 WC-27NiCr와 WC-10Co4Cr이 용사코팅된 시험편을 사용하였다. 다채널 부식시험기인 WonA-tech WMPG-1000을 이용하여, 자연전위를 측정하였으며, 분극실험은 자체 제작한 홀더를 사용하여 $0.3318cm^2$를 노출 시켜 실험하였다. 기준전극은 은/염화은 전극을, 대극은 백금 전극을 사용하였다. 양분극과 음분극 실험을 통해 개로전위에서의 부식거동을 확인하였고, 정전위 실험도 실시하였다. 실험 종료 후 3D현미경 및 전자주사현미경(SEM)을 사용하여 코팅층 표면의 손상거동을 관찰하였다. 캐비테이션 실험은 ASTM-G32 규정에 의거하여 압전효과를 용한 진동발생 장치(RB 111-CE)를 사용하였다. 수조는 전기화학적 부식의 영향을 고려하여 아크릴로 제작하였고, 시험편은 실험장비에 맞게 파인커팅머신을 이용하여 $20mm{\times}20mm$로 절단하여 사용하였으며 혼과 대향하도록 하여 1mm 간격을 두어 실험하였다. 실험 실시 전, 미소전자저울을 사용하여 무게감소량을 측정하였으며 표면관찰을 통하여 캐비테이션 거동을 관찰하였다.

  • PDF

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Synthesis and Electrolyte Characterization of 1-Benzyl-3-butylimidazolium Hydroxide Ionic Liquid (1-Benzyl-3-butylimidazolium Hydroxide 이온성액체 합성 및 전해질 특성 조사)

  • Salman, Muhammad;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.603-606
    • /
    • 2020
  • A hydrophilic alkaline room temperature ionic liquid electrolyte (RT-IL) carrying hydroxide ion as an anion and 1-benzyl-3-butylimidazolium as a cation was synthesized. Electrochemical, physical and structural properties of the synthesized RT-IL were characterized using cyclic voltammetry, ionic conductivity, viscosity, thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), FT-IR, and 1H-NMR measurements. High ionic conductivity and low viscosity characteristics comparable to 0.1 M KCl electrolyte solution were achieved for the RT-IL in addition to a wide electrochemical potential window of about 4.4 V. The results indicate that the RT-IL is promising for future applications as an alternative electrolyte to energy and environmental research fields.

Corrosion Level Measurement Technique for RC Reinforcement Using Non-Destructive Test Methods (비파괴기법을 이용한 철근 콘크리트 벽체 철근의 부식률 예측기법)

  • Roh, Young-Sook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.24-31
    • /
    • 2011
  • In order to measure corrosion level of reinforcement rebar in RC structures, non-destructive test methods which are concrete surface current density method and infrared thermographic technique were employed to measure corrosion levels. Experimental test parameters were various levels of corrosion states(0, 1, 3, 5, 7% of weight loss) and concrete cover depth(30 mm, 40 mm) and two different reinforcing rebar arrangements. The larger amount of concrete surface current density, the higher corrosion level in reinforcement rebar. The laboratory conditions which are ambient temperature and humidity have negligible effect on the infrared thermographical data. After analysis of current density and temperature distribution from concrete surface, corrosion level of reinforcement rebar embedded in concrete can be measured qualitatively based on the amount of electric current and heat flux.