• Title/Summary/Keyword: 자연전위이상

Search Result 39, Processing Time 0.02 seconds

Application of SP Survey and Numerical Modeling to the Leakage Problem of Irrigation facilities (수리시설물 누수탐지에 대한 자연전위법 적용 및 수치 해석)

  • Song Sung-Ho;Kwon Byung-Doo;Yang Jun-Mo;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.257-261
    • /
    • 2002
  • We have carried out integrated research including field survey and numerical modeling to appraise the applicability of SP method to the leakage problems of irrigation facilities. The leakage pattern of the dike studied here can be classified into the three categories: leakage through the abutment, leakage by piping through dike, and leakage due to the composite effects of landslide and distortion of the dike structure. for the numerical modeling to interpret quantitatively SP survey results acquired at dike, we have modified the computer code proposed by Sill (1983) to apply to the leakage problems. The numerical studies match the characteristic patterns of SP anomalies according to the leakage types and appear to be very useful to interpret the leakage zone and path. The SP monitoring results were also well coincided with tidal variations observed at every embankment so we found the SP method is quite effective not only to detect the leakage zone but also to determine the leakage trend. The numerical modeling results also reproduced the SP anomalies due to seawater leakage in the embankment.

A Study on the Possibility of Construction Supervision by Geophysical Prospecting (지구 물리탐사에 의한 시공감리성 연구)

  • Shon, Ho-Woong
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.165-174
    • /
    • 1997
  • It is not possible to define the earth's interior because of it complicity. However, it can be interpreted directly and/ or indirectly. Geophysics is the subject of this study. To study the possibility of construction supervision by geophysical method, geophysical prospecting was performed and studied at the SamYang pumping well area in Cheju Island, where, although underground dam was constructed, the saline water invade the pumping well area. This study focuses on the construction supervision by electrical measurements. Two electric resistivity survey lines are installed in the pumping well site, and at each line electric survey was conducted at ebb and flow tides. To increase the data quality SP (self-potential) survey was also performed. As a result the geophysical exploration methods explained the defect of construction well, and It shows that geophysical probe can be a useful tool for the construction supervision.

  • PDF

제주도 비위생매립지 주변 수리지질환경 파악을 위한 전기, 전자탐사 적용

  • 송성호;용환호;김기표;안중기;김창용
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.112-115
    • /
    • 2003
  • 쓰레기매립장의 침출수 누출 탐지를 위한 물리탐사법은 침출수의 전기전도도를 대상으로 한 전기탐사법이 주로 적용되어 왔다. 이 연구는 제주도에 위치한 비위생매립지를 대상으로 주변 수리지질환경 파악을 위한 전기비저항 탐사와 더불어 매립장 경계부와 토양층을 통한 침출수 누출 영역을 효율적으로 규명하기 위하여 다중주파수를 이용한 소형루프 전자탐사를 병행하여 수행하였으며, 아울러 오염지역의 천부 지하수 유동 방향을 추정하기 위하여 침출수의 유동에 의해 발생될 수 있는 자연전위를 모니터링 하였다. 전기비저항 탐사 및 자연전위 모니터링 결과 매립지 주변을 통한 침출수의 누출 가능성은 거의 없는 것으로 나타났으며, 이는 주변 하천에서 정기적으로 실시한 수질 분석 결과와 일치된다. 또한 소형루프 전자탐사 자료에 대하여 공간 필터링 및 1차원 역산법을 적용한 결과 매립장 경계부의 위치 및 매립장 내부의 심도별 매립물에 의한 저비저항 이상대를 효과적으로 도출 할 수 있었다.

  • PDF

Non-Destructive Diagnosis on the Corrosion of Reinforcing Bar in Concrete (콘크리트중의 철근부식에 대한 비파괴 진단방법에 관한 연구)

  • 윤재환
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.2
    • /
    • pp.75-81
    • /
    • 1992
  • 염분을 함유한 철근콘크리트중의 철근부식에 관한 2년 촉진시험으로부터 콘크리트표면에서 측정한 자연전위값과 실제의 철근 부식상황과를 비교한 결과 철근의 수식상황을 자연전위법을 이용하여 비파괴적으로 진단하는 방법이 유효함을 알았다. 포화칼로멜전극을 사용했을 경우 -300mV이하이면 부식이 발생하였으며 -200mV이상이면 부식이 발생하지 않았다. 또한 부시공시체에 대한 휨강도시험도 행하였으며 중성화에 대한 검토로 행하였다.

Modeling of SP responses for geothermal-fluid flow within EGS reservoir (EGS 지열 저류층 유체 유동에 의한 SP 반응 모델링)

  • Song, Seo Young;Kim, Bitnarae;Nam, Myung Jin;Lim, Sung Keun
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.4
    • /
    • pp.223-231
    • /
    • 2015
  • Self-potential (SP) is sensitive to groundwater flow and there are many causes to generate SP. Among many mechanisms of SP, pore-fluid flow in porous media can generate potential without any external current source, which is referred to as electrokinetic potential or streaming potential. When calculating SP responses on the surface due to geothermal fluid within an engineered geothermal system (EGS) reservoir, SP anomaly is usually considered to be generated by fluid injection or production within the reservoir. However, SP anomaly can also result from geothermal water fluid within EGS reservoirs experiencing temperature changes between injection and production wells. For more precise simulation of SP responses, we developed an algorithm being able to take account of SP anomalies produced by not only water injection and production but also the fluid of geothermal water, based on three-dimensional finite-element-method employing tetrahedron elements; the developed algorithm can simulate electrical potential responses by both point source and volume source. After verifying the developed algorithm, we assumed a simple geothermal reservoir model and analyzed SP responses caused by geothermal water injection and production. We are going to further analyze SP responses for geothermal water in the presence of water production and injection, considering temperature distribution and geothermal water flow in the following research.

Geophysical Investigation of the change of geological environment of the Nanjido Landfill due to the Stabilization Process (난지도 매립장의 안정화에 따른 지질환경 변화 조사를 위한 지구물리 탐사)

  • Lee, Kie-Hwa;Kwon, Byung-Doo;Rim, Hyoung-Rae;Yang, Jun-Mo
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.2
    • /
    • pp.113-126
    • /
    • 2000
  • We have conducted multiple geophysical surveys to investigate the geoenvironmental change of the Nanjido Landfill due to the stabilization process. Geophyscial surveys are comprized of gravity, magnetic, dipole-dipole electrical and SP methods. Due to the field conditions, surveys were conducted on the top surface of the landfill no.2 and southern border areas in front of landfills. The gravity anomalies obtained on the top surface of the landfill no.2 in 1999 show that the gradient of the anomaly on the central area is decreasing in comparison with that observed four years ago. The complexity of magnetic anomaly pattern it also decreasing. These facts suggest that the stabilization work of the Nanjido landfill makes some progress by compaction process due to repetitive subsidence and refilling. The dipole-dipole electrical resistivity and SP data obtained on the outside of the waterproof wall at the landfill no.1 were severely affected by unsatisfactory surface conditions. On the other hand, the dipole-dipole electrical resistivity profiles obtained on the inside and outside parts of the waterproof wall at the landfill no.2 show the blocking effect of leachate flow by the waterproof wall. Few SP anomalies are observed on the top and side surfaces of the landfill no.2, but SP anomalies obtained on the base area inside the waterproof wall strongly reflect the effect of leachate collecting wells.

  • PDF

A Study on Galvanic Corrosion properties between differential Al Alloys (이종 알루미늄 합금 간 갈바닉 부식 특성에 관한 연구)

  • Kim, Sun-Ho;Lee, Seul-Gi;Park, Jun-Mu;Park, Jae-Hyeok;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.96-96
    • /
    • 2018
  • 금속재료 중 알루미늄(Al)은 일반적으로 많이 사용되는 철강재에 비해 그 비중이 약 $1/3(2.7g/cm^3)$인 경량이고 열전도율이 약 3배($196kcal/^{\circ}C$, $20^{\circ}C$)로 높은 특성 등을 갖고 있다. 또한 대량생산에 의한 경제성을 가지기 때문에 건축 구조재, 전기 및 가전 등 다양한 산업 분야에서 널리 사용되고 있다. 특히, 위와 같은 특성으로 인해 열교환기의 종류에서 응축기(Condenser) 및 증발기(Evaporator)는 알루미늄(Al)을 널리 사용하고 있다. 하지만 단일 응축기 부품에도 이종 알루미늄 소재가 사용됨에 따라 갈바닉 부식이 발생할 수 있다는 단점이 있다. 따라서 본 연구에서는 현재 상용되고 있는 열교환기 중 응축기에서의 이종 알루미늄 재료로 인해 나타나는 갈바닉 부식 특성을 관찰-분석-연구 하였다. 본 연구에 사용된 알루미늄 재료는 현재 응축기 재료 중에서 각각 Tube와 Fin으로 널리 상용되고 있는 Al 1100과 Al 3003을 사용하였다. 표면 모폴로지는 SEM을 통해 관찰하였고 EDS를 통해 조성원소를 분석하였다. 또한 내식성 평가를 위해 5% NaCl 환경에서의 SST(Salt spray test, 염수분무시험) 시험과 3% NaCl 용액 내 자연침지 시험 및 탈기된 3% NaCl 용액 내 전기화학적 동전위 양극 분극 시험을 진행하였으며 더불어 갈바닉 부식 시험에 따른 혼합 전위 측정 및 외관 관찰을 하였다. 각 재료는 실험에 대해 동일한 표면적을 노출시켜 시험하였다. 5% NaCl 환경에서의 염수분무 시험 결과 Fin(Al 3003)의 경우에는 Tube(Al 1100) 보다 빠른 부식거동을 보이며 국부적인 공식부식(Pitting corrosion)이 촉진되었다. Tube(Al 1100)의 경우에는 치밀한 Al2O3 형성과 부식에 따른 Al(OH)3를 생성함에 따라 Fin(Al 3003)에 비해 느린 부식거동을 보였다. 3% NaCl 용액 내 자연 침지 및 전위 측정 결과 초기 전위는 Fin(Al 3003, 약 -0.85V/SCE)이 Tube(Al 1100, 약 -1.05V/SCE)에 비해 더 높은 값을 가지며 약 72시간 이후 Tube(Al 1100) 시편이 더 안정적인 전위 값을 나타냈다. 이는 안정적인 Al(OH)3 피막 형성에 기인한 것으로 사료된다. 탈기된 3% NaCl 용액 내 전기화학적 동전위 양극 분극 시험 결과 Fin(Al 3003) 시편에서 더 귀한 부식 전위 값을 나타냈지만 부식 전류는 더 낮은 값을 나타냈다. 상기 시험 결과를 바탕으로 Fin-Tube 간 장기간 접촉 시에는 갈바닉 부식이 발생할 수 있을 것으로 사료된다. 갈바닉 부식 시험 결과 초기 혼합 전위는 약 -1.05 V/SCE를 나타냈으며 약 288시간 경과 후 약 -0.85 V/SCE 값을 나타냈다. 이는 자연 전위 측정 및 동전위 양극 분극 시험에서의 부식 전위 값에서 알 수 있듯이 더 비한 전위인 Tube(Al 1100) 시편이 Fin(Al 3003) 시편에 대해 희생양극적(Sacrificial anode)인 역할을 한 것을 확인할 수 있었다. 또한 갈바닉 부식 전위 측정 간 외관 관찰에서도 Tube(Al 1100) 시편은 빠르게 흑변 하는 것을 확인할 수 있었으며 Fin(Al 3003) 시편은 침지 300시간 이후에도 초기와 유사한 표면 상태 및 광택을 유지하였다. 이상의 SST 시험, 자연 침지 시험, 전기화학적 양극 분극 시험 및 갈바닉 부식 시험 결과를 바탕으로 단일 부품 내 이종 알루미늄 소재 간 접촉 및 그에 따른 갈바닉 부식 발생을 확인할 수 있었다. 따라서 동종 성분이라고 할지라도 단일 부품 제작 시에는 그 사용 환경에 따라 이종 금속 재료의 사용에 대한 재고가 필요할 것으로 사료된다.

  • PDF

Comparative Evaluation on the Corrosion Resistance of Galvalume and Galvanized Steel Pipe (갈바륨 강관과 용융아연도금 강관의 내식성 비교 평가)

  • Choe, In-Hye;Park, Jun-Mu;Lee, Chan-Sik;Mun, Gyeong-Man;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.163-163
    • /
    • 2016
  • 아연계 도금 강판은 우수한 내식성을 가지며 특히 아연의 희생방식기구에 의해 철의 부식을 억제하므로 선박, 건축자재, 전자기기 및 자동차 등 다양한 분야에서 그 수요와 사용범위가 증가하고 있다. 또한 도금 조성비 변화 및 다양한 표면처리 방법을 통해 가혹한 환경에서의 우수한 내식성에 대한 연구가 활발히 진행되고 있다. 그 중 갈바륨(Galvalume)은 55%의 알루미늄(Al)과 45%의 아연(Zn)으로 되어 있으며, 아연의 장점인 희생방식성과 내알카리성, 알루미늄의 장점인 내구성과 내열성, 내산성을 이상적으로 결합시킨 알루미늄(Al)-아연(Zn) 고내식 합금용융도금강판이다. 본 연구에서는 갈바륨 소재를 여러 산업현장에서 강관 형태로 사용할 경우의 내식성을 파악하기 위해 갈바륨 강관과 기존에 사용되고 있는 용융도금재인 용융아연도금 강관을 비교하며 실험을 진행하였다. 냉간압연강관에 용융아연도금 약 $25{\mu}m$, 갈바륨 약 $20{\mu}m$ 두께로 제작된 강관을 사용하였으며 제작된 도금층 표면 모폴로지는 SEM을 통해 관찰하였고, XRD 분석을 통해 결정 구조를 확인하였다. 또한 5% 염수분무 환경 중 노출시험(Salt spray test), 3% NaCl 용액에서의 자연침지 시험 및 3% NaCl 용액 중 전기화학적 양극분극 시험을 진행하여 평가하였다. 5% NaCl 환경에서의 염수분무 시험 결과 용융아연도금의 경우 단면에서는 90시간, 표면에서는 260시간 경과 후 적청이 발생하였다. 반면, 갈바륨의 경우에는 단면에서 210시간 경과 후에 적청이 발생하였고, 표면의 경우에는 900시간 이상에서도 적청이 발생하지 않았다. 이 결과를 통해 용융아연도금에 비해 갈바륨 도금의 내식성이 단면에서는 3배, 표면에서는 4~5배 이상 향상된 것으로 확인되었다. 또한 3% NaCl 용액 중 자연침지 시험 결과 용융아연도금 강관 표면은 24시간 경과 후 열화부를 중심으로 흑변하는 것을 확인할 수 있었으나 갈바륨의 경우에는 900시간 이상 실험이 진행되는 동안 No Scribe 및 Scribe 시편 모두 외관상 변화가 거의 없었다. 단면의 경우, 용융아연도금 시편은 900시간 이상 실험이 진행되는 동안 외관상 변화가 없었으며, 갈바륨 시편의 경우 300시간 경과 하면서 흰색의 아연 부식생성물이 나타났으나 900시간 이후로도 적청은 발생하지 않았다. 자연전위 측정결과 용융아연도금 및 갈바륨 시편 모두 유사한 전위거동을 나타냈지만 단면의 경우 갈바륨 시편이 용융아연도금에 비해 안정적인 거동을 보였다. 3% NaCl 용액 중 전기화학적 양극 분극 시험 결과 용융아연도금이 갈바륨에 비해 귀한 방향의 부식 전위 값을 나타냈으며, 부식 전류밀도도 용융아연도금이 갈바륨에 비해 더 높은 값을 나타내는 것을 확인할 수 있었다. 이상의 염수분무시험, 자연침지시험 및 전기화학적 양극분극시험을 통해 종합적으로 분석-고찰하여 보면, 그 부식이 진행되는 과정은 융융아연도금과 달리 갈바륨 도금의 경우가 다단계적인 부식 과정을 거치면서 우수한 내식 특성을 나타낸다는 것을 알 수 있었다. 즉, 갈바륨 도금은 그 도금 막에 분포된 합금상 원소 성분들이 상호 갈바닉(Galvanic) 작용하며 형성된 부식생성물이 수평적으로 자체 차단(Barrier) 역할을 하는 과정과 부분적 부식-회복 과정을 거치면서 다단계적으로 부식속도를 감소시키게 된다는 것을 확인 할 수 있었다.

  • PDF

Geophysical Survey in the Taran Area on the Central Kalimantan, Indonesia (인도네시아 중부 칼리만탄 타란지역에서의 물리탐사)

  • 조진동;김인준;박인화
    • Economic and Environmental Geology
    • /
    • v.35 no.2
    • /
    • pp.155-162
    • /
    • 2002
  • There are many typical epithermal deposits scattering in the Taran of central Kalimantan. Indonesia. To get the shallow geological information, we carried out the geophysical exploration: spontaneous potential survey, in-suite magnetic susceptibility measurement and relistivity survey method in this area for a few weeks from September 30th to October 27th in 1997. SP survey (Fluke 27 multimeter)/magnetic susceptibility (EK -7 meter) measurement was carried out with a 250m$\times$10m lattice net in N45$^{\circ}$W direction. The dipole-dipole array resistivity survey was conducted with an electrode spacing of ${\alpha}$=30 m and electrode separation index n=7 at the line 5. The result shows that was the gold bearing quartz vein area can be divided into two type lone: low sulfidation type and high sulfidation type zone. The low resistivity value in the survey line 5 indicated a fracture Bone associated with the high sulfidation zone.

Electrical Responses on the Auriferous Mineralized Bone in Sambo Mine (삼보광산 금 광화대에 대한 전기탐사 반응)

  • You Youngjune;Yoo In-Kol;Kim Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.217-224
    • /
    • 2004
  • Self-potential and electrical resistivity methods were conducted for locating the auriferous mineralized zone, called Jija Vein, of Sambo mine, Limsu-ri, Haeje-myeon, Muahn-gun, Jeollanam-do. The host rocks of the mineralization include gneiss, rhyolite and felsic dyke. Ore vein is mainly fissured-filling type and sulfide minerals, such as pyrite, are disseminated in country rock. By the electrical responses from SP and surface resistivity methods., the mineralized zone is supposed to extend about 360 m directed N5W with the width of 20 m to 30 m. From resistivity tomograms using inclined borehole to surface, the ore body shape is interpreted as the width of 20 m in depth 40 m to 50 m.