• Title/Summary/Keyword: 자성물질

Search Result 171, Processing Time 0.034 seconds

Design of the Current Segment Coil for Accelerating the Magnetic Materials (자성물질을 가속시키기 위한 전류 Segment 코일의 설계)

  • Chung, Byung-Tae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.861-866
    • /
    • 2012
  • The distance optimizing between coil and magnetic materials never be specified in the magnetic materials acceleration using the coil till now. We can know to be the distance which optimizes when being in the half position about the distance of intercoil by the result of the max point on the Differential calculus. Whether several top and bottom current segment coil structures were made and the steel ball in which the current segment coil structure is the magnetic materials could be accelerated in the optimizing distance or not confirmed. When the coil valley current about the mass of the steel ball was known as the experiment and it was but to be the nose consequently it applied to the magnetic materials and magnetic fluid, the optimal distance was solved between the coil and material.

A Study of the Properties of Magnetic Particles in Medicinal Ointments (의학용 연고제에 포함된 자성물질 입자들의 성질에 대한 연구)

  • Do, Tae-Sung;Nam, Hyo-Duk;Park, Se-Gon;Hwang, Hyeun-Gook;Hwang, Yong-Soon;Kim, Eng-Chan;Park, Eun-Jung;V. I. Nikolaev;A. V. Bykov
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.69-79
    • /
    • 1997
  • Stability of the properties of magnetite particles in novel medicinal magnetic ointments of multipurpose application has been studied by M ssbauer spectroscopy. It has been found that the comparative analysis of the results obtained by model fitting of $^{57}$ Fe nuclei spectra with those known for the system Fe$_3$O$_4$-${\gamma}$-Fe$_2$O$_3$ allows to identify the phase composition of the particles. It is noted that this composition, as well as that of the initial pure component in the form of a highly dispersed fraction (~100$\AA$), differs noticeably from the stoichiometric one. From the magnetic hyperfine field despite small particle sizes, the particles exhibit no superparamagnetism (in the temperature range from 95 to 300K). Radiative sterilization of the ointments has no effect on the magnetic component composition.

  • PDF

Magnetic Particles in Rainfalls: An Environmental Magnetic Evaluation (강수 함유 자성물질에 대한 환경자기학적 분석)

  • Baatar, Amarjargal;Yu, Yong-Jae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.99-106
    • /
    • 2010
  • To evaluate a potential wash-out effect of rainfalls, a preliminary environmental magnetic test was attempted. Measurement of isothermal remanent magnetization (IRM) and intensive microscopic observations were carried out on the solid particles extracted from the rainfalls collected for the past year (2009) in Daejeon, Korea. Dust particles collected from the rain-free (daily dust) or dustheavy days (during the Asian dust storm event) were also used as a comparison. IRMs were unanimously low for the solid particles extracted from the rainfalls, indicating an efficient wash-out effect of rainfalls as long as the magnetic concentration is concerned. Electron microscopy identified carbonbearing material, (carbon-coated) magnetite, and quartz. It is highly likely that the carbon-containing particles were produced by anthropogenic fossil fuel combustion.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Removal of Radioactive Caesium ion using Ferromagnetic in water : A reivew (강자성체를 통한 수중의 방사능 세슘이온 제거 동향)

  • Yeo, Wooseok;Kim, Jong Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.266-270
    • /
    • 2018
  • 원자력 방사능 폐기물 또는 원자력 발전소 해체시 발생 가능한 세슘 이온은 인체뿐만 아니라 생태계 환경에도 큰 악영향을 미친다고 알려져 있다. 이러한 세슘 이온은 자연 속으로 손쉽게 스며들어 발생한 지역뿐만 아니라 쉽게 퍼지게 되어 넓은 지역까지 피해를 주게 되며, 반감기가 30년으로써 한번 자연계에 누출되면 장시간 잔존하여 인간 및 생태계에 악영향을 미치게 된다. 세슘이온이 몸속에 들어오게 되면 장에서 몸으로 100% 흡수되며 내장에 축척되어 연조직 전체에 분포하게 되며 갑상선 암과 같은 심각한 위험에 초래하게 된다. 2011년 발생한 후쿠시마 원전 사고 이후 국내에서도 많은 관심을 가지기 시작하였으며, 따라서 수중의 세슘이온을 제거하기 위하여 나노 입자 형태의 기능성을 가진 물질들을 적용한 많은 연구가 이루어지고 있다. 이러한 나노물질들은 수중의 세슘이온 제거에 대하여 우수한 제거효율을 보여주고 있으나 나노 입자 특성상 사용 이후 회수가 어려워 기능성 물질들의 확산 및 축적에 따른 2차 환경오염의 문제점까지 발생하게 된다. 최근 수처리 분야에서 외부 자기장을 주게 되면 자성을 띄게 되는 물질인 자성체에 대한 관심이 급등하고 있다. 이러한 자성체들은 수중에서 별도의 회수 시스템 없이 자성으로 인하여 완벽히 자기분리 된다. 세슘제거에 탁월한 기능성 물질과 완벽한 자기분리가 가능한 자성체를 결합하여 특별한 회수장치 없이 외부 자기장만 주어진다면 수중의 세슘을 효과적으로 제거 또는 처리할 수 있다. 자성체 입자 표면에 흡착제인 프러시안 블루나 제올라이트와 같은 흡착제를 합성하여 수중의 세슘을 제거하는 연구가 활발히 이루어지고 있다. 그러나 기존의 자성체보다 좀 더 높은 자성을 가지고 있으며 외부 자기장에 의해 강하게 반응을 한다고 알려져 있는 강자성체(Ferromagnetic)를 사용하게 된다면 흡착제와 결합 이후 더욱더 강한 자성을 가진 흡착제가 탄생하며 이를 사용하면 높은 처리율뿐만 아니라 높은 슬러지 회수율을 가질 수 있다. 따라서 본 연구는 흡착제나 이온교환수지와 같은 기능성 물질을 사용하여 수중의 세슘을 제거하는 메커니즘과 강자성체가 가지고 있는 강한 자성의 성질을 결합한 복합체 제조에 대한 연구조사를 중점적으로 실시하였다. 본 연구에 의해 연구 조사된 결과를 바탕으로 수중의 세슘 이온에 대하여 높은 제거효율과 회수율을 가지는 새로운 형태의 복합체 제조에 관한 정보를 제공하고자 한다.

  • PDF

The NMRD Profiles of Ultrasmall Superparamagnetic Iron Oxide: Computer Simulation

  • 장용민;황문정;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.107-107
    • /
    • 2001
  • 목적: 초상자성 nano-particle 조영제의 자기이완효과에 관한 out sphere 기전에 기초하여 각각의 자기장의 세기에서 T1/T2 자기이완율을 나타내는 NMRD profile을 수치적으로 simulation 하는 프로그램을 개발하고자 하였다. 대상 및 방법: 초상자성 nano-particle 조영제의 경우 초상자성 물질을 생체적합성 고분자로 표면 coating하기 때문에 상자성 조영제와는 달리 전적으로 "out sphere"기여도만을 고려하였고 또한 초상자성 물질의 경우 자기적 에너지의 크기가 매우 크기 때문에 상자성 조영제의 기전에서 사용되는 "low field"근사를 사용할 수 없으므로 Brillouin 함수로 표현되는 총자화에 대한 표현을 적용하였다. nano-particle내에 포함된 Fe 원자수에 따른 T1 및 T2 NMRD Profile과 온도에 따른 T1 및 T2 NMRD Profile 그리고 초상자성 nano-particle size에 따른 T1 및 T2 NMR Profile을 PC (CPU=800 Mhz, memory=128 MB) 환경하에서 symbolic computation tool 인 MathCad (MathCad, USA)를 사용하여 구현하였다.

  • PDF

A Study on Structure and Magnetic Properties of Fe-N Films with Different Sputtering time (증착 시간에 따른 Fe-N 박막의 구조 및 자성 특성에 관한 연구)

  • Han, Dong-Won;Park, Won-Uk;Gwon, A-Ram
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.161.2-161.2
    • /
    • 2017
  • 희토류계 영구자석은 대부분의 전기, 전자 제품의 핵심부품이며 높은 보자력, $BH_{max}$를 가지고 있어 자기기록저장매체, MEMS(엑츄에이터), 소형센서, 소형모터 등의 응용 분야에 적용시키기 위해 다양한 연구들이 진행되고 있다. 그러나 영구자석에 들어가는 희토류계 원소의 수급의 어려움 및 가격의 문제점으로 친환경 자석으로의 전환 및 희토류나 중희토류를 사용하지 않는 비희토류계 영구자석을 제조 및 개발하는데 많은 연구가 이루어지고 있다. 이 중 Fe-N 계 자성물질인 $Fe_{16}N_2$는 포화 자화 값이 현재까지의 비희토류계 자성물질 중 가장 높은 값(240emu/g)을 나타내며 상대적으로 높은 결정자기이방성 상수를 가지고 있어 비희토류계 영구자석 물질 중 하나로 주목받으며 연구되어지고 있다. 본 연구에서는 $Fe_{16}N_2$ 박막을 얻기 위해 DC Magnetron Sputtering 방법을 이용하여 Si wafer 위에 박막을 증착하고 증착시간에 따라 두께를 제어하여 제조한 후 박막의 미세구조, 상 분석, 자성 특성을 관찰을 통해 최적의 공정 조건을 찾고자 하였다. 증착 시간에 따른 박막의 성장 속도는 일정하게 증가하였으며, 증착 시간의 증가에 따라 박막 내 $Fe_{16}N_2$의 상대적인 분율은 감소하였다. 모든 공정 조건에서 $Fe_3N$, $Fe_4N$, $Fe_{16}N_2$ 상들이 섞여 성장하였으며 XRD를 통한 상분석과 더불어 VSM을 통한 자성 특성을 분석해본 결과 $Fe_{16}N_2$의 분율을 가장 높게 성장된 공정 조건은 증착 시간이 10분이며 박막의 두께가 ${\sim}1{\mu}m$ 일 때, 최적의 조건을 얻을 수 있었으며, 이 때의 자성 특성을 분석한 결과 ~2.45T의 포화 자화 값과 ~1.41T의 잔류 자화 값을 얻을 수 있었다.

  • PDF

A Study on the Removal of Suspended Solids Included in Yellow Soil Water by Using Magnetic Powders (자성분말체를 이용한 황토수에 포함된 부유물질 제거에 관한 연구)

  • Kim, Yun-Jeong;Kim, Dong-Gyu;Lee, Huk-Hee;Chang, Tae-Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.683-687
    • /
    • 2008
  • When suspended solids are removed by natural sedimentation, it is necessary to use mainly huge equipments and waste great cost. This is a problem that must be solved certainly as soon as possible. In this study, suspended solids of yellow soil water were rapidly removed by controlling pH and amounts of magnetic powder, organic and inorganic flocculants. In the case of the suspended solids of 0.3% yellow soil water, the most excellent turbidity was achieved at pH between 7 and 7.5.

Mn 도핑 농도에 따른 ZnO 나노 입자의 구조와 자성 특성 연구

  • Kim, Jeong-Hun;Kim, Seon-Ho;Jeon, Gwang-Deok;Lee, Ji-Eun;Lee, Hui-Su;Jeong, Jin-Cheol;Choe, Pu-Reum;Eo, Jin-Seok;Park, Jun-Ho;Lee, Ji-Un;Choe, Seung-Yeon;Choe, Gyu-Hyeon;Baek, Min;Yang, U-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.604-604
    • /
    • 2013
  • 차세대 반도체 분야인 스핀트로닉스 소자의 필수적인 물질인 강자성-반도체 하이브리드 물질인 Dilute magnetic semiconductor (DMS)에 관한 연구가 최근 많은 관심을 가지고 있다. 그중에서 넓은 에너지 밴드 갭 에너지(3.37 eV)를 가지고 있고 상온에서 엑시톤 결합 에너지가 ~60 mV로 광전자 소자, 전계 디스플레이 에 응용이 가능한 물질인 ZnO는 최근에 전이금속을 도핑하여 상온에서 강자성 특성을 나타내어 활발한 연구가 이루어지고 있다. 그러나, 이 물질에 대한 특성과 자성의 원인 규명에 관한 연구는 논란이 되고 있다. 본 연구에서는 Mn이 도핑된 ZnO 나노 입자를 만들고, Mn 물질의 도핑 농도에 따른 ZnO 나노 입자의 구조, 크기 및 자기 구조를 측정하여 구조와 자성의 상관관계에 관한 연구하였다. ZnxMn1-xO 나노 입자는 화학적 졸-겔(sol-gel) 방법을 이용하여 준비하였다. ZnxMn1-xO 나노 입자의 크기 및 격자 구조적 특징은 XRD (X-ray diffraction)와 TEM (Transmission Electron Microscope), SEM (Scanning Electron Microscope), SANS (Small Angle Neutron Scattering)를 이용하여 측정하였고 물질의 자기적 특징은 SQUID를 이용하여 조사하였다. Mn 도핑이 증가함에 따라 격자간격이 커지고 나노 입자의 크기는 감소하였으며, Zn와 Mn의 성장 시, 비율이 9:1의 경우에 상온에서 강자성 특성이 나타남을 보았다. 그 이상의 Mn 도핑 비율에서는 상자성 특성이 나타남을 보았다. 본 연구를 통하여 스핀트로닉스 소자 응용을 위한 ZnO 나노 입자에 최적의 Mn 도핑 농도를 제시하고 나노 입자의 자기 특성 형성의 원인 및 모델을 제시하였다.

  • PDF