• Title/Summary/Keyword: 자동혈압계

Search Result 17, Processing Time 0.031 seconds

Verification of Reliable Blood Pressure Monitor in a Moving Ambulance during an Emergency (응급상황시 이송중인 구급차에서 신뢰할 수 있는 혈압계 검증)

  • Jeon, Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.91-97
    • /
    • 2022
  • The purpose of this study was to analyze the measurements of blood pressure and time using manual and automatic blood pressure monitors in various road conditions to verify reliable blood pressure monitor in a moving ambulance. First, the manual blood pressure monitor palpation on unpaved roads showed a systolic pressure deviation of 5 mmHg. However, the automatic blood pressure monitor showed two measurement failures, one reading failure, and the measured systolic pressure deviation was 35 mmHg. The measurement time was 102 seconds faster on average than the automatic blood pressure monitor. Second, the palpation of the manual blood pressure monitor while going over speed bumps remained constant at 130 mmHg. However, the automatic blood pressure monitor had a systolic pressure deviation of 52 mmHg. The measurement time was 61 seconds faster on average than the automatic blood pressure monitor. Finally, the manual blood pressure monitor palpation on the sharp curve road showed a systolic pressure deviation of 5 mmHg. The automatic blood pressure monitor had one reading failure and the measured systolic pressure deviation was 21 mmHg. The measurement time showed that the manual blood pressure monitor was 101 seconds faster than the automatic blood pressure monitor. As a result, in a moving ambulance during an emergency, the manual blood pressure monitor showed high reliability because the blood pressure measurement was constant and the measurement time was short.

Normal blood pressure values and percentile curves measured by oscillometric method in children under 6 years of age (진동식 자동 혈압계로 측정한 6세 이하 아동의 정상 혈압치와 백분위수 곡선)

  • Sohn, Jin A;Lee, Hee Sook;Lim, Kyoung Aha;Yoon, So Young;Jung, Jo Won;Kim, Nam Su;Noh, Chung Il;Lee, Soon Young;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.998-1006
    • /
    • 2008
  • Purpose : Hypertension is defined as average systolic blood pressure and/or diastolic blood pressure that is ${\geq}95^{th}$ percentile for gender, age, and height on ${\geq}three$ occasions. Knowing that blood pressure values increase in children as they grow older, the purposes of this study were to measure blood pressure by an oscillometric device and to determine normal values and percentile curves for children. Methods : Systolic and diastolic blood pressures were measured twice with an oscillometric device in 3,545 boys and 3,145 girls under six years of age, in Seoul. Using this data, we determined average blood pressure values and percentile curves based on gender and age; we subdivided these values into blood pressures of $50^{th}$, $90^{th}$, $95^{th}$, and $99^{th}$ percentiles, by percentile of height. The regression coefficients and standard deviations of the systolic and diastolic blood pressure values were obtained from linear regression models. Results : Older boys and girls had higher systolic and diastolic blood pressure values. Older boys and girls in the same percentile of height for age had higher systolic and diastolic blood pressure values. Taller boys and girls within the same age group had higher systolic and diastolic blood pressure values. Conclusion : Blood pressure standards based on gender, age, and height were obtained via an oscillometric method. Llimitation of this study is that the study population was not from the whole country, but exclusively from Seoul. Nonetheless, the data from this study will be helpful in diagnosing and managing hypertension in Korean children.

Time for Young Adults to Reach Resting Blood Pressure after Walking as measured by an Automatic and a Mercury Sphygmomanometer (20대 성인의 보행 후 휴식시간에 따른 진동식 자동혈압계와 수은혈압계의 안정혈압 도달 시점)

  • Choi, Min-Jung;Sohng, Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.21 no.4
    • /
    • pp.370-379
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the time for young adults to reach resting blood pressure after walking as measured by an automatic and a mercury sphygmomanometer. Methods: Participants were 33 nursing students in their 20s. Blood pressure after walking was measured every minute on both arms simultaneously for a total of 6 times after walking for 12 minutes on a treadmill at ratings of perceived exertion (RPE) of 11. Data were analyzed using paired t-test, Bland-Altman plots and repeated measures ANOVA. Results: Systolic blood pressure after walking was the same as measurements corresponding to resting blood pressure after 3 minutes of resting if measured with the automatic sphygmomanometer and 4 minutes of resting if measured with the mercury sphygmomanometer. Conclusions: In order to measure the resting blood pressure for healthy young adults who performed low-density walking for 12 minutes on flat land, the measurement needs to be made after a resting time of at least 3 minutes in the case of an automatic sphygmomanometer and 4 minutes in the case of a mercury sphygmomanometer.

Evluation of the DINAMAP 8100 Automated Blood Pressure monitor ; comparison with the Mercury Sphygmomanometer (수은 혈압계와 DINAMAP 8100 자동 혈압계의 혈압측정치 비교연구)

  • Kim Mee-Yeon;Choi Hee-Kang;Kim Nam-Jin
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.3 no.1
    • /
    • pp.96-107
    • /
    • 1996
  • Automated blood pressure monitors have gained acceptance in many clinical settings with the increasing demand, the accurate BP measuring devices reguire the need for validation. We have evaluated the Dinamap 8100, an oscillometric automated blood pressure monitor, using the Mercury sphygmomanometer as a reference. Comparison of sphygmomanometers was conducted 60 patients (30-Normotensive group, 30-Hypertensive group at Seoul National University Hospital. Two trained observers took measure blood pressure(systolic/diastolic) at the same time using the Dinamap 8100 on one arm and the Mercury on the other. For each measurement, the device was randomly selected from a group of devices repetively used for the experiment. Mean readings for systolic pressure with the Dinamap 8100 in normotensive group were lower(mean difference ; 4.26mmHg) than the Mercury type. Mean readings for systolic pressure with the Dinamap 8100 in hypertensive group were lower(mean difference ; 9.05mmHg) than the Mercury type. Mean readings for diastolic pressure with the Dinamap 8100 in normotensive group were lower (mean difference ; 7.46mmHg) than the Mercury type. Mean readings for diastolic pressure with the Dinamap 8100 in hypertensive group were lower(mean difference ; 9.03mmHg) than the Mercury type. We have found that blood pressure readings with the Dinamap 8100 were lower than those with the Mercury type. we are using the Mercury type in clinics, although it has observer bias and terminal digit preference. But the Dinamap 8100 is readily portable, simple to use, and capable of preventing observer bias and terminal digit preference. The Dinamap 8100 is acceptable for blood pressure determination in subjects who are normotensive or hypertensive ones.

  • PDF

Normative blood pressure references for Korean children and adolescents (한국 소아 청소년 정상 혈압 참고치)

  • Lee, Chong Guk;Moon, Jin Soo;Choi, Joong-Myung;Nam, Chung Mo;Lee, Soon Young;Oh, Kyungwon;Kim, Young Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.33-41
    • /
    • 2008
  • Purpose : It is now understood that blood pressure (BP) measurement in the routine pediatric examination is very important because of the relevance of childhood BP to pediatric health care and the development of adult essential hypertension. There hasn't been a reference table of BP for Korean children and adolescents up to now. This study was to make normative BP references and to provide criteria of hypertension for Korean children and adolescents. Methods : BP measurements were done on 57,433 Koean children and adolescents (male: 29,443, female: 27,990), aged 7 to 20 years, in 2005. Heights and weights were measured simultaneously. Oscillometric devices, Dinamap Procare 200 (GE Inc., Milwaukee, Wi, USA), were used for the measurements. BPs were measured 2 times and mean levels were gathered for the analysis. Outliers of 2,373 subjects with overweight per height, over +3SD, were excluded for the analysis. For the BP centiles adjusted by sex, age and height, fixed modified LMS method which was adopted from the mixed effect model of 2004 Task Force in NHLBI (USA) was used. Results : Normative BP tables for Korean children and adolescents adjusted for height percentiles (5th, 10th, 25th, 50th, 75th, 90th, 95th), gender (male, female) and age(7 to 18 years) were completed. Height centiles of Korean children and adolescents are available from Korean Center for Disease Control and Prevention homepage, http://www.cdc.go.kr/webcdc/. Criteria of hypertension (95th, 99th percentile) and normal range of BP (50th, 90th) adjusted for height percentiles, age and gender were made. Conclusion : This is the first study to make normative BP tables and define hypertension for the Korean children and adolescents. Reliability and accuracy of Dinamap Procare 200 oscillometer for BP measurements remains debatable.

Measuring Blood Pressure Using Oscillation Signal from an Automatic Sphygmomanometer (자동혈압계의 오실레이션 신호를 이용한 혈압 측정)

  • Kim, Dong-Jun;Kim, Young-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1720-1724
    • /
    • 2012
  • This study describes an oscillometric-based blood pressure measuring algorithm by detecting turning points of oscillation signal from digitally filtered cuff signals of an automatic sphygmomanometer. The blood pressure measuring algorithm uses a characteristic ratios method from the turning points. The accurate values of the systolic/diastolic blood presures(SBP/DBP) are calculated using the peaks in the ranges of characteristic ratios. Performances of the proposed algorithm and four automatic sphygmomanometers are compared with the mercury manometer(manual type sphygmomanometer), regarding the SBP and DBP values of manual sphygmomanometer as the reference values. The performance test showed the proposed algorithm revealed the best results in errors and a statistical analysis. Therefore this algorithm can be usable in any automatic sphygmomanometers.ssure states. This may be compromising results for subject-independent sensibility evaluation using EEG signal.

Effect of Green Tea and Coffee Drinking after Meal on the Postprandial Fall of Blood Pressure in Elderly Person with Postprandial Hypotension (식후저혈압 노인에서 식후의 녹차와 커피 섭취가 혈압하강에 미치는 효과)

  • Son, Jung Tae
    • 한국노년학
    • /
    • v.36 no.4
    • /
    • pp.1141-1155
    • /
    • 2016
  • The purpose of this study was to compare the preventive effects of green tea and coffee drinking on postprandial hypotension in the elderly. A total of 30 women ($81.2{\pm}6.8years$) who had experience of postprandial hypotension participated 3 interventions by random order allocation. During the experimental interventions, each participant had a cup of instant coffee (60mg caffeine), or green tea (15.8mg caffeine) after lunch, and control group had only their lunch. Systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate (HR) were measured with 15 minute interval from 30 minutes before the meal to 120 minutes after the meal. The preprandial SBP and DBP were not significantly different between three groups. Postprandial SBP reduction measured at the 1 hour after meal was significantly smaller in coffee group compared to the control group, whereas green tea group was not ($-15.1{\pm}17.9mmHg$ vs $-13.4{\pm}22.4mmHg$ vs. $-4.1{\pm}18.6mmHg$ for control, green tea, and coffee group, respectively, p=.032). Likewise, DBP decrement at the 1 hour after meal was significantly smaller in coffee than control group ($-12.8{\pm}13.0mmHg$ vs $-6.9{\pm}16.6mmHg$ vs $-0.8{\pm}13.4mmHg$ respectively, p=.033). The HR response of the three groups were not significantly different throughout the intervention. Coffee drinking was potentially beneficial for preventing postprandial hypotension and resultant falling event.

Relationship between Blood Pressure and Impairment of Cognitive Function In Some Rural Residents Aged 60-64 (일부 60-64세 농촌 거주자에서 혈압과 인지기능 장애와의 관계)

  • Lee, Moo-Sik;Chun, Jong-Chan;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.2
    • /
    • pp.208-214
    • /
    • 2000
  • Objectives : Face-to-face interviews were conducted to investigate the relationship between blood pressure and the impairment of cognitive function in rural elderly (N=932) aged 60-64 in Dalsung County, April to September in 1996 Methods : Impairment of cognitive function was defined as a score of less than 23 by the Korean version of the Mini-Mental State Examination (MMSEK). Blood pressure was measured once in each subject using a portable automatic sphygmomanometer. Results : By univariate logistic regression on males, no category of systolic blood pressure bore statistical significance. Groups with diastolic blood pressures of, less than 80 mmHg, 90-94 mmHg, and more than 95mmHg had odds ratios of more than one compared with the reference group (80-89 mmHg). This was most significant in the group with blood pressures lower than 80 mmHg, which had a statistically significant odds ratio of 1.68 (95% confidence interval CI; 1.02-2.75). No category of blood pressure was statistically significant in females. Multivariate logistic regression for males, with adjustment for age, educational attainment, smoking, alcoholic drinking, body mass index, atherosclerotic disease, and antihypertensive medication use, did not alter the odds ratios significantly in terms of systolic blood pressure. However, the group with diastolic blood pressure of less than 80 mmHg had an increased odds ratio of 2.01 (95% CI; 1.15-3.52) compared with the reference group. In females, systolic blood pressure did not alter the odds ratio, but the group with a diastolic blood pressure of less than 80 mmHg had a statistically significant odds ratio of 0.57 (95% CI; 0.37-0.89). Conclusions : These results suggest that the relationship between blood pressure and cognitive function status is stronger diastolic than systolic blood pressure and that there is a complex relationship between blood pressure and cognitive function by sex.

  • PDF

A Study on Implemetation of Non-invasive Blood Pressure (비침습적 혈압 측정 시스템 구현에 관한 연구)

  • 노영아;이종수;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.451-454
    • /
    • 2000
  • Invasive methode and Non-invasive methode are used in blood pressure measurement. The Invasive methode can Set the correct measured blood pressure but, it has patient feels uncomfortable. So most of cases use Non-invasive methode. The Oscillometric method is commonly apply to modem electric sphygmomanometer and using various algorithm. In this paper describe about a algorithm it control and to determinate the cuff pressure, and filtering that data for measure the blood pressure. The communicating with personal computer can pressure deflation is by Solenoid valve and it uses RS-232 system in packet communication. The main using algorithm for blood pressure measurements are maximum amplitude algorithm and oscillometric algorithm. MAA(maximum amplitude algorithm) has various measured oscillation it depend on patient's age, height, weight and arm circumference size. In this paper, 1 studied the various measured oscillation apply to characteristic ratio and can get the result of systolic blood pressure, diastolic blood pressure, mean blood pressure. It was not used same ratio to measuring oscillation. In the MAA(maximum amplitude algorithm), we hope for reduce the difference with the real blood pressure and the measured blood pressure, when it applied with various specific ratio.

  • PDF

Blood Pressure of Healthy Newborns in the First Week of Life (분당 차병원에서 출생한 신생아 혈압치 비교)

  • Lee Jung-Sun;Park Shin-I;Park Hye-Won;Kim Se-Hyun;Hah Tae-Sun;Lee Jun-Ho
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.8-14
    • /
    • 2005
  • Purpose : This study was peformed to study normative blood pressure data in full-term neonates that may be used to facilitate Identification of neonatal hypertension.Methods : 383 newborns born in our hospital from May 2003 to January 2004 were enrolled in this study Using an oscillometric device(BP-88 NEXT, COLIN Corp.), their blood pressures were measured more than one time within a week after birth. According to each clinical variable such as sex, delivery mode, birth weight, gestational age and presence of maternal disease or perinatal problems, we divided the population into groups and calculated the mean blood pressures of each group. We compared mean blood pressures between the divided groups according to each clinical variable statistically.Results : Mean systolic and diastolic blood pressure of the Population was 70.8$\pm$ 10.9 mmHg and 43.4 $\pm$ 8.0 mmHg, respectively. There was no satistically significant difference in blood pressure according to clinical variables. Mean systolic pressure showed positive correlation with birth weight and gestational age(r=0.1420, 0.03130).Conclusion : Our results are almost in agreement with Zubrow's data from 695 newborns in U.S.A, 1995. Our data may be helpful for early detection and management of neonatal hypertension, thereby maintaining renal function ,and preventing possible complications of renal disease.

  • PDF