• 제목/요약/키워드: 자동소화장치

검색결과 22건 처리시간 0.021초

화재피해 감소 위한 자동소화장치 적용범위 개선 (Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage)

  • 백창선;박인선
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구 (A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer)

  • 김도현;조남욱;윤충호;박필용;박근성
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.53-62
    • /
    • 2017
  • 경제 및 산업의 원천 에너지원인 전력은 생산과 소비의 지역적 상이함으로 장거리 수송을 필수로 하며, 다중환상망(Multi-loop) 형식의 송배전계통으로 전력을 공급한다. 실질적 사용에 앞서, 변전소내 변압기를 통해 변전과정을 거쳐 각 사용처의 특성을 고려하여 전력공급이 이루어지고 있으며 변압기는 본체, 권선, 절연유, 부싱등의 구조로 결합되어 있다. 변전소에서 발생하는 변압기화재는 가구와 상업시설등에 전기공급을 중단시키고 각종 안전사고를 발생시키는 1차 손실뿐만 아니라 2차적으로 경제 손실을 야기한다. 화재의 원인은 부싱 하부파손에 따른 절연유 유출과 약 1초 이내 발화점에 도달하는 절연유에 의한 화재의 연쇄반응으로 파악된다. 화재피해의 최소화를 위해 연기감지기, 자동소화설비 등이 구축되어있으나 감지기의 동작 및 소화가스 방출지연 등으로 화재진화를 위한 골든타임 확보의 부재가 문제되고 있다. 이에 본 연구는 초기 화재진화에 따른 골든타임 확보의 중요성에 따라 화재확산을 방지하고 절연유 누출을 차단하는 능동적 메커니즘의 필요에 따라 수행되었다. 따라서 화염에 의해 팽창하는 고온형상 유지물질과 기계적 화염차단장치를 적용한 부싱방화구조체를 개발하였다. 실제 부싱 및 프렌지규격을 적용하여 제작된 변압기모형에 부싱방화구조체를 설치하여 실규모 화재실험을 수행하였다. 초기화염으로부터 3초내에 정확한 위치와 높이에 부싱방화구조체가 작동함을 확인하였으며 이는 실제 변압기화재 시 화염 확대를 효과적으로 차단할 수 있을 것으로 사료된다.