Kim, Tae-Hun;Ye, Ki-Hun;Kim, Jae-Kwang;Sung, A-Young
Journal of Korean Ophthalmic Optics Society
/
v.13
no.2
/
pp.29-36
/
2008
Purpose: We have evaluated both the reliability and accuracy of refractive measurement from autorefractor by comparing with subjective refraction data. Methods: Measurements of refractive error were performed on 198 eyes of 99 subjects in noncycloplegic condition. Also we analyzed refraction results and evaluated repeatability and accuracy of subjective refraction and autorefraction. Furthermore we analyzed accuracy of autorefractor by Fourier analysis. Results: Reliability coefficient of the autorefraction for the right eye were determined to by 0.993, 0.974 and 0.925 respectively, in the spherical, cylinderical component and cylinderical Axis. Also, the reliability coefficient of the autorefraction for the left eye were found to be 0.991, 0.948 and 0.886, respectively, in the spherical, cylinderical component and cylinderical Axis. From the Fourier analysis no statistically significant differences in $J_{0}$ component were found between the auto and subjective refraction measurements (p>0.05) whereas difference of refractive power of $J_{45}$ component when compared with the subjective refraction were -0.019, -0.164. Conclusions: We conclude that autorefractormeter can be effectively used to measure the refractive power within the error limits.
Kim, Tae-Hun;Kwon, Young-Seok;Ye, Ki-Hun;Sung, A-Young
Journal of Korean Ophthalmic Optics Society
/
v.11
no.4
/
pp.293-298
/
2006
For this study, Clinical evaluation of the diverse Autorefractors was performed to examine validity and repeatability compared with subjective refraction. Measurements of refractive error were performed on 212 eyes of 106 subjects subjectivly noncycloplegic. Intersession repeatability of the Autorefractors were also assessed on all 106 subjects together with intersession repeatability on 7 to 14 days intervals. Spherical powers of subjective refraction and autorefractions by Autorefractors were analyzed by paired T-test.
Purpose: To investigate the proper distance from patient to target when measuring refractive error using open view target type auto-refractor(OVTAR), it was compared refractive errors between by OVTAR using N-vision-K5001 auto-refractor and internal fixation target type auto-refractor(IFTAR) using Canon auto-refractor. Methods: 21 subjects(42 eyes) aged 22.2(${\pm}$3.4) years old who had over 1.0 of corrected visual acuity and no ocular disease were participated for this study. Noncycloplegic measurements of refractive error were performed using a IFTAR(RK-F1, Canon, Japan) and an OVTAR(N-vision-K5001, Shin-nippon, Japan). The distances from subjects to targets in using the open the view target type auto-refractor were 1 m, 3 m, 4 m and 6 m. The refractive errors were compared between by IFTAR and by 1 m, 3 m, 4 m and 6 m target distances respectively using OVTAR. Results: At 1 m fixation distance the mean of refractive errors for total subjects was not significantly different between by OVTAR(-2.75${\pm}$1.84 D) and by IFTAR(-2.95${\pm}$2.04 D)(p=0.06). However at 3, 4 and 6 m fixation distance refractive errors by OVTAR were significantly lower myopic refractive errors than by IFTAR(p<0.05). Conclusions: The distance from subject to fixation target is needed over 3 m for the measurement of refractive error using OVTAR even not to 5~6 m distance.
Clinical evaluation of the Closed-view autorefractor and Open-view autorefractor was performed to examine validity and repeatability compared with subjective refraction. Measurements of refractive error were performed on 126 eyes of 65 subjects (aged $26{\pm}7.5$ years) subjectively noncycloplegic. Intersession repeatability of the Closed-view and Open-view were also assessed on all 65 subjects together with Intersession repeatability on 7 to 14 days intervals. Spherical powers and spherical equivalent values of subjective refraction and autorefractions by Closed-view and Open-view were analyzed by paired T-test. The mean spherical powers of subjective refraction, Closed-view and Open-view were determined to be $-2.125{\pm}2.155D$, $-2.146{\pm}1.907D$, $-2.117{\pm}2.121D$, respectively. The mean spherical equivalent values of subjective refraction, Closed-view and Open-view were determined to be $-2.362{\pm}2.204D$, $-2.391{\pm}1.967D$, $-2.366{\pm}2.162D$, respectively. The results showed that the refractive errors as measured by the Closed-view and Open-view were found to be similar to the subjective refraction in all components.
Kim, Dae-Young;Lee, Koon-Ja;Baarg, Saang-Bai;Kim, Hyojin
Journal of Korean Ophthalmic Optics Society
/
v.15
no.2
/
pp.123-130
/
2010
Purpose: The study was conducted to compare the values of auto-refraction, manifest refraction and cycloplegic refraction in school-aged children. Methods: One hundred five myopic school children ranged from 6 to 14 years old (210 eyes, $10.28{\pm}1.59$ years old) were recruited and noncycloplegic auto-refraction (AR) and manifest refraction (MR) were conducted and then underwent cycloplegia and refractive status (CR) again with the auto-refractometer. Results: Refractive powers measured by AR, MR, and CR were highly correlated. However, spherical and cylindrical powers of the subjects measured by AR were measured higher negative power than in CR (p<0.001). From 210 eyes, the discrepancy rate in the spherical and cylindrical powers were 40 eyes (19%) and 19 eyes (9%) of the total subjects, respectively and the differences between noncycloplegic and cycloplegic refractions were higher with the spherical and cylindrical powers increasing. Conclusions: The use of the autorefractometer in children with negative spherical power without cycloplegia may overestimate the actual myopia that subjective refraction is the most important in prescription for the eyeglasses and regression equations would be used to prognose the cycloplegic refraction from the auto-refraction as the basic data for the subjective refraction.
Purpose : To find out the reliability of autorefractometer after laser refractive surgery Methods : We measured and compared spherical and cylinder powers of those undergone LASEK surgery with 1.0 of naked vision after at least 3 months of the surgery with an autorefractometer(CANON Full Auto Ref-Keratometer RK-F1, Japan) and a retinoscope(Streak Retinoscope 18200, WelchAllyn, USA), and also applied spherical equivalent powers. The refractive status before surgery was divided into high, medium, and low myopia according to the results measured using an autorefractometer, and then analyzed again the reliability of the autorefractometer after surgery according to the preoperative refractive status. The agreement of two methods was identified using Bland-Altman(Bland-Altman limits of agreement(LoA)). Results : After the surgery, when comparing spherical, cylinder and equivalent powers in the whole data measured by autorefractometry and retinoscopy significant differences were found(p<0.01). According to the degree of refractive errors, all sort of refractive errors was shown significantly different(p<0.01) except for cylinder power of the medium myopia. In general, the refractive errors especially spherical and spherical equivalent powers by autorefractometry were shown a myopic trend from -0.38 D to -0.53 D. On the other hand, it was shown a hyperopic trend of approximately +0.30 D using retinoscopy. In comparison of two objective refractions, it was shown a myopic trend as $-0.51{\pm}0.45D$(LoA +0.36 D ~ -1.39 D) and compatible. Conclusion : Even though it would be positive in terms of compatibility of the methods, it is necessary that the glasses should be prescribed by subjective refraction since autorefractometry is shown myopic in those undergone the surgery and suffering from myopic regression.
The purpose of this research was to measurement real Accommodative response amount using both eyes open-view autorefractometer. Compared each Accommodative response amount to distinction of sex, age, kind of ametropia, amount of astigmatism and kind of astigmatism. The subjects were 153 healthy men and women between the age of 20~80 years. Age comparison, 20 years 1.15D, 30 years 1.23D and above 40 years 0.60D. It was no difference between 20 to 30 years old. But, is decrescent remarkably above 40 years old. Ametropia examined by hypermetropia 1.78D, emmetropia 1.51D, low myopia 1.08D, middle myopia 0.72D, high myopia 0.643D. Myopia increased, Accommodative response amount was expose that decrease. Astigmatism examined by non astigmatism 1.13D, low astigmatism 1.12D, middle astigmatism 0.85D, high astigmatism 0.83D. Astigmatism increased, Accommodative response amount was expose that decrease. The sex and astigmatism type difference appeared with the fact that the result is not a difference.
Purpose: This study has been conducted to know the prevalence of anisometropia and corneal refraction, accommodative response of myopic anisometropia. Methods: The study subject were 67 persons who myopic anisometropia of at least 1.00D, from among 808 total subject without ophthalmic diseases history from age 5 to 89 and the test were used to examine with both eyes open-view autorefractometer (NvisionK-5001). Results: The case which anisometropia were 85(10.5%) persons and myopic anisometropia were 67(78.8%) persons among the anisometropia. Difference between higher myopic eye and lower myopic eye were -1.22D${\pm}$0.94 in spherical equivalent, -0.25D${\pm}$0.72 in accommodative response, 0.04D${\pm}$0.68 in corneal refraction. In addition, the same case of both eyes accommodative response were 33(49.3%) persons, the great case of lower myopic eye accommodative response were 25(37.3%) persons and the great case of higher myopic eye accommodative response were 9(13.4%) persons. Conclusions: Myopic anisometropia was not affected by corneal refraction and both eyes difference of spherical equivalent was less as compared with both eyes difference of accommodative response.
Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.
Journal of the Korean Society for Precision Engineering
/
v.28
no.3
/
pp.370-376
/
2011
Recently, the application range of plastic gears is widely expanding by the development of engineering plastics with good mechanical properties. Plastic gears have excellent performances such as light weight, water resistance and vibration absorbing ability for metallic gears. In this study, the optimization of injection molding process was done for the large disk type plastic gears of auto phoropter. Design Of Experiment (Taguchi method) was adopted to find a tendency of molding conditions that influence the flatness of disk type gear. Four main factors for molding conditions were selected based on injection temperature, filling time, packing pressure and mold temperature. Also, Filling, packing and cooling analyses were carried out to evaluate Z directional deflection of large disk type gear by using the simulation software (Moldflow) based on the DOE. From the results, it was found that the injection temperature and packing pressure are the most sensitive parameters for the Z directional deflection of large disk type gears.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.