• Title/Summary/Keyword: 자동계측시스템

Search Result 192, Processing Time 0.029 seconds

Experience of Reticulocytes Measurement at 720 nm Using Spectrophotometer (분광광도계를 이용한 720 nm에서 망상적혈구 측정 경험)

  • Sung, Hyun-Ho;Seok, Dong-In;Jung, You-Hyun;Kim, Dae-Jung;Lee, Seok-Jae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.382-389
    • /
    • 2017
  • Currently, reticulocyte experimental calculation technology used in clinical laboratories are divided two types: manual and automated. Manual reticulocyte counting using a microscopy lacks accuracy due particularly to its low reproducibility, affecting the accuracy of manual reticulocyte count. Moreover, Automatic blood corpuscle analyzer flow cytometry is difficult to be used in underdeveloped countries and small scale laboratories due to relatively high cost. Therefore, this study tried to find a new method to complement these drawbacks. The aim of this study was to compare the stained reticulocytes count by spectrophotometer and also to analyze the statistics of spectrophotometer and flow cytometer. The same 8 EDTA samples were repeated 36 times to compare the agreement between spectrophotometer and flow cytometer. This study measured the specimen diluted 600 times at 700~780 nm by 10 differences. Wavelength between 710 to 730 by absorbance showed a positive correlation between standard data and test data (r=0.967, p<0.01), presenting a correlation between variables. Statistical analyses of regression for test and standard parametric data, the optimal dilution factor was 600 times. Therefore, this study tried to technical utilizes such as contributing economical for the reticulocyte absorbance apply from the auto spectrophotometer, a monitoring system for the reticulocyte relation anemia, etc. Therefore, more extensive studies, including an auto chemical analyzer application, will be needed.

A Plan for Establishing IOT-based Building Maintenance Platform (S-LCC): Focusing a Concept Model on the Function Configuration and Practical Use of Measurement Data (IOT 기반 건축물 유지관리 플랫폼 구축(S-LCC) 방안 : 기능구성과 계측 데이터 활용을 위한 개념 모델을 중심으로)

  • Park, Tae-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.611-618
    • /
    • 2020
  • The reliability of the results of LCC analysis is determined by accurate analytical procedures and energy data from which the uncertainty is removed. Until now, systems that can automatically measure these energy data and produce databases have not been commercialized. Therefore this paper proposes a concept model of an S-LCC platform that can automatically collect and analyze electric energy consumption data of equipment systems using the IOT, which is the core tool in the Fourth Industrial Revolution and operates the equipment system efficiently using the analyzed results. The proposed concept model was developed by the convergence of existing BLCS and IOT and was comprised of five modules: Facility Control Module, LCC Analysis Module, Energy Consumption Control Module, Efficiency Analysis Module, and Maintenance Standard Reestablishment Module. Using the results of LCC analysis deduced from this system, the deterioration condition of an equipment system can be identified in real-time. The results can be used as the baseline data to re-establish standards for the maintenance factor, replacement frequency, and lifetime of existing equipment, and establish new maintenance standards for new equipment. If the S-LCC platform is established, it would increase the reliability of LCC analysis, reduce the labor force for entering data and improve accuracy, and would also change disregarded data into big data with high potential.

Design and Implementation of Automobile Air Cleaner Tester Using LabVIEW (LabVIEW를 이용한 자동차 공기청정기 성능시험장치 설계 및 구현)

  • Ahn, Jun-Sik;Jeong, Sung-Jae;Kim, Il-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.257-258
    • /
    • 2007
  • 이 논문에서는 자동차 공기청정기의 성능을 테스트하기 위한 자동화 시험 장치를 설계 및 구현하였다. 기존의 수동시험장치의 경우 정확한 유량 조절이 불가능하여 성능시험평가결과에 오차가 크고 시험과정이 불편하였다. 본 논문에서는 신뢰성 높고, 자동제어가 가능한 시스템을 설계하기 위하여 유량센서, 압력센서, 온도 센서, 습도 센서들의 데이터를 데이터 수집 장치를 통해 수집하고, 컴퓨터 기반의 제어 및 계측 프로그램인 LabVIEW를 이용하여 제어 및 모니터링 프로그램을 제작하였다. 그래픽 기반의 LabVIEW를 이용함으로써, 사용자에게 편리한 인터페이스를 제공하고, 기존의 수동 시스템보다 정확한 성능테스트 데이터를 제공함으로써, 에어필터의 품질향상이 되도록 하기 위한 성능 테스트 장치를 제작한다.

  • PDF

A study on Development of Auto Steel-Plate Pile System Using Measurement System (계측시스템을 이용한 자동 강재 적치 관리 시스템 개발에 관한 연구)

  • Yu, Ji-Hun;Kim, Ho-Kyoung;Kim, Rea-Soo;Sin, Hun-Joo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.424-428
    • /
    • 2008
  • On processing of the shipbuilding, Various steel plates are used as the important material in many fields including the shell plate, a structure, etc. Therefore, the proper steel plate management system like a warehousing, pile, delivery is very important. Presently Operators manage the steel plate by using the software program, but they manage many parts manually, so many problems are generated on the steel plate check, management, and operator safety. In order to solve this problem, we developed Auto Steel-Plate Piling System. Also this system automatically manages and traces the steel-plate from warehousing to delivery.

  • PDF

A Formal Verification Technique for PLC Programs Implemented with Function Block Diagrams (함수 블록 다이어그램으로 구현된 PLC 프로그램에 대한 정형 검증 기법)

  • Jee, Eun-Kyoung;Jeon, Seung-Jae;Cha, Sung-Deok
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.3
    • /
    • pp.211-215
    • /
    • 2009
  • As Programmable Logic Controllers (PLCs) are increasingly used to implement safety critical systems such as nuclear instrumentation & control system, formal verification for PLC based programs is becoming essential. This paper proposes a formal verification technique for PLC program implemented with function block diagram (FBD). In order to verify an FBD program, we translate an FBD program into a Verilog model and perform model checking using SMV model checker We developed a tool, FBD Verifier, which translates FBD programs into Verilog models automatically and supports efficient and intuitive visual analysis of a counterexample. With the proposed approach and the tool, we verified large FBD programs implementing reactor protection system of Korea Nuclear Instrumentation and Control System R&D Center (KNICS) successfully.

Design of Monitoring System for Managing Officer's Operation with Supporting of Nautical Safety (선박 안전운항 지원을 위한 승무원 운용상황 감시 시스템의 설계)

  • Kim, Ok-Soo;Lee, Myung-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1335-1343
    • /
    • 2012
  • Although navigation systems and automatic identification technologies are in use for nautical safety of ocean vessels, ship collisions are increasing due to the growing number of overseas transportations. Since these accidents are mostly caused by the watch officers and crews' human mistakes, it is essential to develop a new set of systems to prevent such misfortunes. Therefore, we suggest a control and management system which monitors crews in order to conduct secure on-board navigation and nautical safety. We also materialized a mobile terminal system and portable device for the crews to check the status of the ship, and we designed a platform for an integrated surveillance system to assure a harmless voyage. Lastly, we attested the mutual connections of integrated safety-related data.

Analysis of a Weak Zone in Embankment Close to a Drainage using Resistivity Monitoring Data (전기비저항 모니터링을 이용한 저수지 제체 취수시설 취약성 해석)

  • Lim, Sung Keun
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.1
    • /
    • pp.8-14
    • /
    • 2018
  • For the purpose of maintenance and prevention of earth fill dams against damage from natural hazards, automatic monitoring through various measuring instruments and resistivity survey has been carried out. Reservoirs and embankments have the structural vulnerability on the agricultural usages since most of them were built more than thirty years ago. The main aim to use monitoring method is to verify the safety and integrity of the dam. Resistivity survey can detect potential weaknesses, such as defective zones, anomalous seepages or internal erosion processes. Permanent resistivity monitoring systems were installed at a reservoir, which daily measurements have been taken every 6 hour. Using monitoring data for one year, anomalous seepage and structural defects were clarified for dam safety. Annual water level fluctuations are around 10 m. During their operation, reservoir dams are subject to a never-ending hydraulic load from the reservoir, which over the years may cause changes in the properties of the inner parts of the dam construction. Detailed analysis of the monitoring results was performed and showed that resistivities at most locations have been very stable over the full monitoring period excluding the effects of water fluctuation and seasons. To investigate the detectability of weak zone using the DC resistivity monitoring, numerical modeling with a simplified model for the drainage at a reservoir dam was also performed. The results showed that the seepage zone near drainage in a reservoir dam could be detected by resistivity response change.

Performance Evaluation of Automatic Exercise Weight and Repetition Measuring Device Add-on for Existing Fitness Machines (기존 운동기기 부착용 운동중량/횟수 자동측정기기의 성능평가)

  • Kim, Jung Gi;Lee, Yongkoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.329-332
    • /
    • 2017
  • In this study, a performance evaluation was carried out to develop a new add-on device with an algorithm for automatically measuring the exercise weight and repetitions when using an existing fitness machine. The developed device was designed to be simply attached to an exercise machine to measure the exercise weight and repetitions. The measured data are transferred to a smartphone using Bluetooth. As result, it is possible to detect the weights and repetitions from three users with different exercise habits with little error. The system can measure the user's motion and transfer the data to various devices capable of utilizing the workout data, giving it the advantage of being applicable to personalized health care and rehabilitation therapy.

Automatic Measurement of Temperature in Real Time by Using an Internal and Data Processing System (인터넷을 이용한 원격 실시간 온도 계측 모니터 및 계측데이터 자동처리 시스템)

  • Kim, Hui-Sik;Kim, Yeong-Il;Seol, Dae-Yeon;Nam, Cheol;O, Heung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.99-102
    • /
    • 2003
  • In this paper, we have developed a system for monitoring and processing the real time sensor data in remote site through Internet. For realizing this system, measurement equipment and protocol are used to transmit the measurement data to remote server and to process measurement data. In server part, the received data from remote site sensor is converted to text or graphic charts for user. The measurement device in sensor part receives the sensor data form sensor and store the received data to its internal memory for transmitting data to server part through Internet. Also the measurement device can receive data form server. The temperature sensor is corrected to the measurement device located in laboratory and the measurement device measures temperature of laboratory which can be confirmed by user through Internet. We have developed a server program working on the Linux to store measurement data from measurement device to server memory. The program is use for SNMP(Simple Network Management Protocol) to exchange data with measurement device. Also the program changes the measurement data into text and graphic charts for user display. The program is use apache PHP program for user display and inquiry. The real time temperature measurement system can be applly for many parts of industry and living.

  • PDF

Assessment on the Monitoring System for KURT using Optical Fiber Sensor Cable (광섬유센서케이블을 이용한 지하처분연구시설의 감시시스템 운영 평가)

  • Kim, Kyung-Su;Bae, Dae-Seok;Koh, Yong-Kwon;Kim, Jung-Yul
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.293-301
    • /
    • 2010
  • Optical fiber cable, as a sensor, was installed on the wall of KAERI(Korea Atomic Energy Research Institute) Underground Research Tunnel(KURT) in order to monitor the physical stability of the tunnel, which was constructed for technical development and demonstration of radioactive waste disposal. This monitoring system has two simultaneous measurements of temperature and strain over time using Brillouin backscatter. According to the results of the monitoring from Jan. 2008 to Nov. 2009, there is no significant displacement or movement at the tunnel wall However, the cumulative volume of total strain increased slightly as time passes with the comparison of the reference observation, which was measured in Jan. 2008. The change in cumulative volume of total strain indicates that the strain level had been affected by saturation and de-saturation phenomena due to groundwater fluctuation at several points at KURT. This system is based on the distributed sensing technique concept, not point sensing. By using this system, a displacement can be detected with the range from $20{\mu}{\varepsilon}$ to $28,000{\mu}{\varepsilon}$ every 1m interval in minimum. A temperature variation can be monitored at every 0.5m interval with the resolution of 0.01 in minimum. Based on the study, this monitoring system is potentially applicable to long term monitoring systems for radioactive waste disposal project as well as other structures and underground openings.