• Title/Summary/Keyword: 자기 공진

Search Result 235, Processing Time 0.021 seconds

Manufacture of an Acousto-Optical Spectrometer for Radio Astronomical Observations (우주전파관측용 음향광학 전파분광기의 제작)

  • 임인성;최재현;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • The acousto-optical spectrometer as a new type backend of the receiver system for radio astronomical observations is manufactured for radio signal analysis. We studied on the effect of Acousto-Optic and Acousto-Optic devices and designed the optics system. We manufactured the optical mount and the CCD detector for deflected beam and interface card. This acousto-optical spectrometer consisted of a laser, optics, acousto-optic deflector, CCD detector and Interface card. This system use He-Ne laser as a light source and use optics to get parallel beam and to focus the deflected beam. Acousto-optic deflector converts IF signal to ultrasonic wave and deflect the laser beam according to the Bragg deflection. The ultra wide band acousto-optic deflector has 1 GHz bandwidth and a total of 2,048 channel Charge Coupled Device for signal detection. In this study, we discuss the theoretical description on the effect of Acousto-optics, the design of the optics, manufacture of optical mount, CCD detector, interface card and we presented the results of experiment. As a result of measurement, we have 1,000 channels bandwidth from CCD channels.

  • PDF

Backfill Materials for Underground Facility with Recycling Materials - Quantification of Design Parameters (재활용재료를 이용한 지하매설물용 뒤채움재 - 설계입력변수 정량화)

  • Lee, Kwan-Ho;Kim, Seong-Kyum
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.91-96
    • /
    • 2011
  • The design, construction and management of underground facilities as infrastructure of nation should be properly carried out. One of reasons for underground facilitie's failure is a non-proper construction of backfill materials. This is common for circular underground pipes. A non-proper compaction is the cause of settlement and decrease of performance of underground facilities. The use of controlled low strength materials is an alternative to reduce the couple of failure problems. The flowability, self-cementation, and non-compaction are the major advantages to use the controlled low strength materials. In this research, couple of recycled materials, such as in-situ soil, water-treatment sludge, and crumb rubbers, were adopted. The basic properties of each materials were determined according to KS or ASTM. Also, couple of laboratory tests were carried out to get the design parameters for geotechnical and roadway area.

A Study on Characteristics and Equivalent Circuit Model of Underwater Wireless Power Transfer System by Salinity (염도에 따른 수중 무선전력전송 시스템 특성 및 등가모델 연구)

  • Lee, Jeong-Geon;Kang, Wonshil;Ku, Hyunchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.851-856
    • /
    • 2018
  • In this study, we analyze the characteristics of wireless power transfer(WPT) based on magnetic resonance in an underwater environment and propose an equivalent model suitable for underwater WPT. The proposed underwater WPT equivalent model is constructed by expanding the free-space WPT T-model reflecting characteristics change according to media. Considering the water salinity, we propose a method to extract the parameters of the proposed model based on the S parameters. To verify the proposed model, a 6.78-MHz underwater WPT system was constructed and compared with the predicted power transfer efficiency of the model. As a result, it was confirmed that the proposed model predicts the variation of characteristics with an average error of less than 3 %.

A Study for Frequency Characteristics of Solenoid-Type RF Chip Inductors (크기에 따른 솔레노이드 형태 RF 칩 인덕터의 주파수 특성 연구)

  • Kim, Jae-Wook
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.145-151
    • /
    • 2007
  • In this work, small-size, high-performance solenoid-type RF chip inductors utilizing a low-loss ${Al_2}{O_3}$ core material were investigated. The size of the chip inductors fabricated in this work were $0.86{\times}0.46{\times}0.45m^3$, $1.5{\times}1.0{\times}0.7m^3$, $2.1{\times}1.5{\times}1.0m^3$, and $2.4{\times}2.0{\times}1.4m^3$ and copper (Cu) wire with $27{\sim}40{\mu}m$ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 7 have the inductance of 13 to 100nH and exhibit the self-resonant frequency (SRF) of 6.4 to 1.1GHz. The SRF of inductors decreases with increasing the inductance and the inductors have the quality factor of 50 to 80 in the frequency range of 300MHz to 1.3GHz. In this study, small-size solenoid-type RF chip inductors with high inductance and high quality factor were fabricated successfully.

  • PDF

Design and manufacture of mini loop coil probe style magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 초미니 Loop-코일프로브 삽입형 자기치료기의 설계 및 제작)

  • Kim, Whi-Young;Choi, Jin-Young;Park, Sung-Jun;Kim, Hee-Je
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.1
    • /
    • pp.153-169
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

FEA and Model test of Backfill Materials for Underground Facility with Recycling Materials (재활용 재료를 이용한 지하 매설물용 뒤채움재의 모형시험 및 유한요소해석)

  • Lee, Kwan Ho;Kim, Sung Kyum
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.177-177
    • /
    • 2011
  • 현재 대부분 사용되는 지하매설물용 뒤채움재는 다짐공법을 많이 사용하고 있으며, 실제로 이러한 방법은 부적절한 다짐으로 인해 침하 및 내구성 저하로 인해 파손을 초래하는 경우가 많다. 이러한 문제를 해결 할 수 있는 하나의 대안으로 유동성 뒤채움재를 이용할 수 있다. 유동성 뒤채움재는 초기 유동성, 시간에 따른 자기 강도 발현 무다짐공법 적용 등 많은 장점을 가지고 있다. 본 연구에서는 현장발생토사, 정수장슬러지 및 폐타이어분말 등 재활용 재료를 이용한 유동성 뒤채움재의 기본물성을 평가하였다. 각각의 재활용재료에 대한 입도 및 비중을 평가하였고, 최적배합설계를 결정하였으며, 모형 시험과 유한요소 해석을 위한 기본 물성값을 위해 일축압축시험, 삼축압축시험, 공진주시험 등을 수행하였다. 최적배합설계를 산정하는 과정에서 수행한 실험중 대표적인 시험으로 자가수평능력 및 자기다짐등에 필요한 유동성을 판단하는 Flow시험(ASTM D 6133) 결과 기준으로 정한 20cm이상의 값을 얻을 수 있었으며 일축압축강도의 경우 시공 후 유지 보수가 용이한 강도인 $3.0kg/cm^2{\sim}5.6kg/cm^2$이하로 설계하였으며 28일재령 일축압축강도 결과 $3.15{\sim}3.74kg/cm^2$라는 유지보수에 적당한 결과값을 나타내었다. 이 배합이 현장에서 사용이 가능하다는 것으로 판단하고 현장모형시험과 유한요소해석를 통하여 현장에서 사용하였을 때 관의 변형과 관에 작용하는 하중변화를 확인하고 현장모형시험과 유한요소해석 간의 상관관계를 규명하였다. 현장 모형 시험은 현장과 비슷하게 제작된 모형을 이용하였으며 최대한 현장과 비슷한 조건에서 뒤채움재를 타설과정 중과 타설이 완료된 상태에서 7일 양생 후 하중재하와 같이 두가지 경우에서 수직 수평토압, 관의 수직 수평변위, 관의 종단변형을 측정하였다. 유한요소해석 프로그램은 Midas GTS를 이용하여 실시하였으며 관의 변형률, 유효응력을 측정하여 규명하였다.

  • PDF

Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System (6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석)

  • Yoon, Seok;Jung, Hyeonjong;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.954-963
    • /
    • 2017
  • In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.

Some Basic Investigation on Wireless Power Transfer (무선 전력 전송에 관한 기본적인 고찰)

  • Park, Jongmin;Nam, Sangwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.10
    • /
    • pp.959-965
    • /
    • 2014
  • This paper summarizes the previous research results of fundamental investigation done in SNU on the wireless power transfer. Firstly, the physical limitation of a wireless power transfer using the spherical modes is reviewed. It is found that wireless power transfer depends only on the radiation efficiency of the antennas and the distance between two antennas involved. Secondly, we review the characteristics of WPTS with different sources and compare the performance differences of WPTS according to the source type. In addition, the method for efficient WPTS is suggested when the distance between antennas is varied. Finally, by using the time domain solution of the coupled mode equation, we present an analytic formula which can be used to differentiate Inductive Coupling(IC) and Magnetic Resonance Coupling(MAC) which are often used ambiguously in wireless power transfer system.

High Frequency Magnetic Characteristics of $Co_{90}Fe_{10}$ Thin Films and $Co_{90}Fe_{10}/SiO_2$ Multilayers ($Co_{90}Fe_{10}$ 박막 및 $Co_{90}Fe_{10}/SiO_2$ 다층박막의 고주파 자기특성)

  • 윤의중;진현준;박노경;문대철;김좌연
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.300-307
    • /
    • 1998
  • The $Co_{90}Fe_{10}$ single layer films were deposited on various substrates (glass, Si, polymide) using high vacuum RF magnetron sputtering system and nominall 1000 $\AA$ thick $Co_{90}Fe_{10}$ alloy films had a good high frequency characteristic. $M_S$ and $H_{an}$ values obtained from the B-H characteristic of the $10{\times}[100 nm \;Co_{90}Fe_{10}/100 nm\; SiO_2]$ multilayers agreed well with those obtained by calculation. Complex relative permeability $(={\{\mu}_r={\mu}_r',-j{\mu}$\mu$_r")$ at frequency f was measured from the transmission characteristics $(S_{11},\; S_{21}\;parameters)$ of the microstrip line which has a stacked structure consisting of sample magnetic films and a conductor and is connected to a network analyzer. The ${\mu}_r'-f$ characteristic was abtained from the megnetic absorption, which was analyzed from the S-parameter characteristics of the microstrip line. The ${\mu}_r'-f$ characteristic was also calculated from the ${\mu}_r"-f$-f characteristic using the Kramers-Kronig relation. The measurement results were confirmed to agree well with those obtained by calculations.culations.

  • PDF