• Title/Summary/Keyword: 자기장 측정

Search Result 535, Processing Time 0.027 seconds

An Experiment of User Experience and Neurophysiological Patterns during Watching and Playing a Video Game (게임콘텐츠의 시청행위와 게임행위의 사용자 경험과 뇌파반응특성)

  • Jang, Han-Jin;Kim, Si-Sung;Noh, Ghee-Young
    • Journal of Korea Game Society
    • /
    • v.15 no.2
    • /
    • pp.19-32
    • /
    • 2015
  • Presence, flow, and arousal are interesting user experiences provided by video and people's demand for media which responds to personal interest is getting strong. This research compares video watching and game play by conducting a survey and measuring brain wave to find out the difference of those user experiences in the two media. As a result, all the three user experiences were proved to be significantly higher in game play than video watching. And those EEG frequencies which are known to be related to the state of flow were also measured higher scalp distribution of the game play group. Finally, presence, arousal, and EEG(${\alpha}$, ${\beta}$, ${\delta}$) were found to have influence on the flow state in game play. This research is intended to prove above relations by experiment and make a contribution to the theoretical and methodological improvement in the related area.

A Study on the Generation of Frame Synchronization Words for W-CDMA System (W-CDMA 시스템을 위한 프레임 동기 단어 발생에 관한 연구)

  • 송영준
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.451-460
    • /
    • 2004
  • The pilot bit pattern of W-CDMA system is used for the channel estimation and frame synchronization confirmation. This paper proposes the binary sequences for the frame synchronization for wideband code division multiple access (W-CDMA) system. We present the circuit for the generation of ideal frame synchronization property using the binary sequences called frame synchronization word(FSW). W-CDMA system uses compressed mode where up to 7 slots per one 10 msec frame are not transmitted to make measurements from another frequency without a full dual receiver terminal. It is shown that the proposed frame synchronization words also maintain the optimal frame synchronization property in the compressed mode by using the complementary mapping relationship of preferred pair. And we discuss the realization circuit for the generation of frame synchronization words by using the concept of preferred pairs, complementary mapping relationship, and maximal length sequence.

A study on determinants of flow status in smoking simulation game (흡연시뮬레이션 게임에서 몰입 결정요인에 대한 연구)

  • Jang, Han-Jin;Noh, Ghee-Young
    • Journal of Korea Game Society
    • /
    • v.17 no.2
    • /
    • pp.165-174
    • /
    • 2017
  • This research was conducted to find out determinant variables which can influence the degree of flow in smoking simulation game. We set up flow experience as a dependent variable. Several factors including empathy, health concern, and brainwave(${\alpha}$, ${\beta}$) EEG(Electroencephalogram) as a physiological indicator, which was expected to affect flow, were set up as independent variables to perform regression analysis. As a result, empathy, health consciousness, and ${\beta}$ wave had positive influences on flow in smoking simulation game but ${\alpha}$ wave had negative effect. This research empirically analyzed users' experience and neurophysiological changes which can influence on flow in serious game and contributed to theoretical and methodological development in health-related game research.

The influence of magnet on tissue healing after immediate implantation in fresh extraction sites in dogs (성견에서 발치 후 즉시 식립 임플란트에 설치한 자석이 주위 조직에 미치는 영향)

  • Yu, Seok-Min;Cho, In-Ho;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.435-444
    • /
    • 2009
  • Statement of problem: The clinical use of electric and electomagnetic fields for fracture healing applications began in the early 1970s. Since then, several technologies have been developed and shown to promote healing of fractures. Developments of these devices have been aided in recent years by basic research and several well controlled clinical trials not only in the medical field but in dentistry. Purpose: The purpose of this study was to compare alveolar bone reduction following immediate implantation using implants onto which magnets were attached in fresh extracted sockets. Material and methods: Four mongrel dogs were involved. Full buccal and lingual mucoperiosteal flaps were elevated and third and fourth premolars of the mandible were removed. Implants with magnets and implants without magnets were installed in the fresh extracted sockets and after 3 months of healing the animals were sacrificed. The mandibles were dissected and each implant sites were sampled and processed for histological examination. Results: The marginal gaps that were present between the implant and walls of the sockets at the implantation stage disappeared in both groups as a result of bone fill and resorption of the bone crest. The buccal bone crests were located apical of its lingual counterparts. At the 12 week interval the mean of marginal bone resorption in the control group was significantly higher than that of the magnet group. The majority of specimens in magnet group presented early bone formation and less resorption of the buccal marginal bone compared to the control group. Conclusion: Within the limitations of this study, it could be concluded that implants with magnets attached in the early stages of implantation may provide more favorable conditions for early bone formation and reduce resorption and remodeling of marginal bone.

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.

A Study on the Geometric Design Parameters for Optimization of Cooling Device in the Magnetocardiogram System (심자도 장비의 냉각장치 특성 최적화를 위한 기하 설계 변수 연구)

  • Lee, Jung-Hee;Lee, Young-Shin;Lee, Yong-Ho;Lim, Hyun-Kyoon;Lee, Sung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • A magnetocardiogram (MCG) is a recording of the biomagnetic signals generated by cardiac electrical activity. Biomagnetic instruments are based on superconducting quantum interference devices (SQUIDs). A liquid cryogenic Dewar flask was used to maintain the superconductors in a superconducting state at a very low temperature (4 K). In this study, the temperature distribution characteristics of the liquid helium in the Dewar flask was investigated. The Dewar flask used in this study has a 30 L liquid helium capacity with a hold time of 5 d. The Dewar flask has two thermal shields rated at 150 and 40 K. The temperatures measured at the end of the thermal shield and calculated from the computer model were compared. This study attempted to minimize the heat transfer rate of the cryogenic Dewar flask using an optimization method about the geometric variable to find the characteristics for the design geometric variables in terms of the stress distribution of the Dewar flask. For thermal and optimization analysis of the structure, the finite element method code ANSYS 10 was used. The computer model used for the cryogenic Dewar flask was useful to predict the temperature distribution for the area less affected by the thermal radiation.

Correlationship of the electrical, optical and structural properties of P-doped ZnO films grown by magnetron sputtering (마그네트론 스퍼터링에 의해 phosphorous 도핑된 ZnO 박막의 전기적, 광학적, 구조적 특성의 연관성)

  • Ahn, Cheol-Hyoun;Kim, Young-Yi;Kang, Si-Woo;Kong, Bo-Hyun;Han, Won-Suk;Cho, Hyung-Koun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.177-177
    • /
    • 2007
  • ZnO는 3.36eV의 넓은 밴드캡을 가지는 II-IV족 반도체로써 태양전지, LED와 같은 광학적 소자로 이용이 기대가 되는 물질이다. 더욱이, 상온에서의 60meV에 해당하는 큰 엑시톤 에너지와 밴드캡 에지니어링이 가능하다는 장점 때문에 광학적 소자로 널리 이용되고 있는 GaN을 대체할 수 있는 물질로 주목을 받고 있다. 하지만, p-type ZnO는 형성이 어렵고 낮은 이동도와 케리어 농도의 특성을 보이고, 대기 중에 장시간 노출할 경우 n-type ZnO의 특성으로 돌아가는 불안정성을 보이고 있다. 최근에 몇몇의 연구자들에 의해 V족의 원소인 P(phosphorous), N(nitrogen), As(arsenic))를 도핑하여 p-type ZnO의 형성에 대한 논문이 발표되고 있다. 또한, V족 원소 중에 P는 p-type ZnO 형성에 효과적인 도핑 물질로 보고되 고 있다. 본 연구는 마그네트론 스퍼터링을 이용하여 다양한 온도에서 성장된 P도핑 ZnO 박막의 특성에 대해 연구하였다. P도핑된 ZnO 박막은 사파이어 기판에 buffer층을 사용한 Insulator 특성의 ZnO박막위에 400, 500, 600, $700^{\circ}C$에서 성장되 었다. 박막의 특성 분석에는 325nm의 파장을 가지는 He-Cd의 레이져 광원을 사용하여 10K의 저온 PL과 0.5T의 자기장을 사용한 van der Pauw configuration에 의한 Hall effect측정, 그리고 결정성 분석에는 XRD와 TEM을 이용하였다. 상온 Hall-effect 측정 결과, $400{\sim}600^{\circ}C$ 에서 성장된 박막은 n-type의 특성을 보였고, $700^{\circ}C$에서 성장된 Phosphorous 도핑 ZnO박막은 $1.19{\times}10^{17}$의 캐리어 농도를 가지는 p-type의 특성을 보였다. 그리고 XRD분석과 TEM분석을 통하여 박막의 성장온도가 증가 할수록 P도핑된 ZnO박막의 결정성이 향상되는 것을 알 수 있었다. 또한 10K의 저온 PL분석을 통해 p도핑에 의한 액셉터에 관련된 피크들을 관찰할 수 있었다.

  • PDF

Surface Wave Method II: Focused on Passive Method (표면파 탐사 II: 수동 탐사법을 중심으로)

  • Cho, Sung Oh;Joung, Inseok;Kim, Bitnarae;Jang, Hanna;Jang, Seonghyung;Hayashi, Koich;Nam, Myung Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.1
    • /
    • pp.14-25
    • /
    • 2022
  • The passive surface wave method measures seismic signals from ambient noises or vibrations of natural phenomena without using an artificial source. Since passive sources are usually in lower frequencies than artificial ones being able to ensure the information on deeper geological structures, the passive surface wave method can investigate deeper geological structures. In the passive method, frequency dispersion curves are obtained after data acquisition, and the dispersion curves are analyzed by assuming 1D-layered earth, which is like the method of active surface wave survey. However, when computing dispersion curves, the passive method first obtains and analyzes coherence curves of received signals from a set of receivers based on spatial autocorrelation. In this review, we explain how passive surface wave methods measure signals, and make data processing and interpretation, before analyzing field application cases.

A Study on Measuring the Integrated Risk of Domestic Banks Using the Copula Function (코플라 함수를 이용한 국내 시중은행의 통합위험 측정)

  • Chang, Kyung-Chun;Lee, Sang-Heon;Kim, Hyun-Seok
    • Management & Information Systems Review
    • /
    • v.30 no.4
    • /
    • pp.359-383
    • /
    • 2011
  • One of the representative prudential regulations is the capital regulation. The current regulation and international criteria are just simply adding up the market risk and credit risk. According to the portfolio theory due to diversification effect the total risk is less than the summation of market and credit risk. This paper investigates to verify the existence of diversification effect in measuring the integrated risk of financial firm by the copula function, which is combine the different distribution maintain their propriety. The result of the test shows that in measuring the integrated risk not only the correlation and but also the proprieties of market and credit risk distribution are very important. And the tail of risk distribution is important when measuring the economic capital, especially the external impact to the financial market. This paper's contribution is that the empirical evidence in considering the relationship between market and credit risk the integrated risk is less than sum of them.

  • PDF