• Title/Summary/Keyword: 자기자극장치

Search Result 35, Processing Time 0.019 seconds

Magnetic Properties of Electroless Co-Mn-P Alloy Deposits (무전해 Co-Mn-P 합금 도금층의 자기적 특성)

  • Yun, Seong-Ryeol;Han, Seung-Hui;Kim, Chang-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.3
    • /
    • pp.274-281
    • /
    • 1999
  • Usually sputtering and electroless plating methods were used for manufacturing metal-alloy thin film magnetic memory devices. Since electroless plating method has many merits in mass production and product variety com­pared to sputtering method, many researches about electroless plating have been performed in the United State of America and Japan. However, electroless plating method has not been studied frequently in Korea. In these respects the purpose of this research is manufacturing Co-Mn-P alloy thin film on the corning glass 2948 by electroless plating method using sodium hypophosphite as a reductant, and analyzing deposition rate, alloy composition, microstructure, and magnetic characteristics at various pH's and temperatures. For Co-P alloy thin film, the reductive deposition reaction 0$\alpha$urred only in basic condition, not in acidic condition. The deposition rate increased as the pH and temperature increased, and the optimum condition was found at the pH of 10 and the temperature of $80^{\circ}C$. Also magnetic charac­teristics was found to be most excellent at the pH of 9 and the temperature of $70^{\circ}C$, resulting in the coercive force of 8700e and the squareness of 0.78. At this condition, the contents of P was 2.54% and the thickness of the film was $0.216\mu\textrm{m}$. For crystal orientation, we could not observe fcc for $\beta$-Co. On the other hand,(1010), (0002), (1011) orientation of hcp for a-Co was observed. We could confirm the formation of longitudinal magnetization from dominant (1010) and (1011) orientation of Co-P alloy. For Co-Mn-P alloy deposition, coercive force was about 1000e more than that of Co P alloy, but squareness had no difference. For crystal orientation, (l01O) and (lOll) orientation of $\alpha$-Co was dominant as same as that of Co- P alloy. Likewise we could confirm the formation of longitudinal magnetization.

  • PDF

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF

A Study on the Phobia Treatment Using 3D Virtual Reality System (3D 가상환경시스템 이용한 공포증 치료에 대한 연구)

  • Paek Seung-Eun
    • The Journal of Information Technology
    • /
    • v.5 no.4
    • /
    • pp.45-55
    • /
    • 2002
  • Virtual Reality(VR) is a new technology which makes humans communicate with computer. It allows the user to see, hear, feel and interact in a three-dimensional virtual world created graphically. In this paper, we introduced VR into psychotherapy area and developed VR system for the exposure therapy of acrophobia. Acrophobia is an abnormal fear of heights. Medications or cognitive-behavior methods have been mainly used as a treatment. Lately the virtual reality technology has been applied to that kind of anxiety disorders. A virtual environment provides patient with stimuli which arouses phobia, and exposing to that environment makes him having ability to over come the fear. In this study, the elevator stimulator that composed with a position sensor, head mount display, and audio system, is suggested. To illustrate the physiological difference between a person who has a feel of phobia and without phobia, heart rate was measured during experiment. And also measured a person's HR after the virtual reality training. In this study, we demonstrated the subjective effectiveness of virtual reality psychotherapy through the clinical experiment.

  • PDF

Acupuncture Analgesia : A Sensory Stimulus Induced Analgesia Observed by functional Magnetic Resonance Imaging (침의 진통효과: 체성감각신경자극으로 유도된 진통작용에 대한 기능성자기공명영상장치를 이용한 연구)

  • Cho, Zang-hee;Hwang, Seon-chool;Son, Young-don;Kang, Chang-ki;Wong, Edward K.;Bai, Sun-joon;Lee, Un-jung;Sung, Kang-kyung;Park, Tae-seok;Kim, Young-bo;Min, Hoon-ki;Oleson, Terry
    • Journal of Acupuncture Research
    • /
    • v.21 no.2
    • /
    • pp.57-71
    • /
    • 2004
  • Objective : Physiological evidence regarding acupuncture's effect in human patients is not yet well established, despite considerable evidence for its therapeutic efficacy. Besides target or disease specificity of acupuncture, acupuncture analgesia (AA) appears to be another large subclass that poses many questions, such as whether there is point specificity with respect to which acupoint is most effective for a particular condition. Methods : We observed brain activation with functional magnetic resonance imaging (fMRI) using a set of stimuli that consist of pain, pain following Meridian acupuncture, and pain following Sham acupuncture. Results : Among the new observations, the most interesting fact is that data sets of both Meridian acupuncture and Sham acupuncture show decreased activation of the same brain areas related to the pain processing signals. Present functional MRI study demonstrate two important biological observations that could elucidate AA mechanism in human participants: the effects of acupuncture occur through mediation of the higher brain areas. Sham acupuncture stimulation appears to be almost as effective as traditional Meridian acupoint stimulation, suggesting that acupuncture is not entirely point specific. Decreased activation in the limbic paleo cortical areas appears to be the probable neurological manifestation of AA and strongly implies that acupuncture stimulation inhibits the transmission of ascending pain signals to the higher cortical areas by the previously known descending pain inhibitory circuit. Conclusion : We, therefore, a hypothesized that this pain inhibitory circuit is initiated and mediated via the broad sense Hypothalamus Pituitary Adrenal (BS HPA) axis in conjunction to the "sensory stimulation."

  • PDF

Identification of Nonstationary Time Varying EMG Signal in the DCT Domain and a Real Time Implementation Using Parallel Processing Computer (DCT 평면에서의 비정상 시변 근전도 신호의 인식과 병렬처리컴퓨터를 이용한 실시간 구현)

  • Lee, Young-Seock;Lee, Jin;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.507-516
    • /
    • 1995
  • The nonstationary identifier in the DCT domain is suggested in this study for the identification of AR parameters of above-lesion upper-trunk electromyographic (EMG) signals as a means of developing a reliable real time signal to control functional electrical stimulation (FES) in paraplegics to enable primitive walking. As paraplegic shifts his posture from one attitude to another, there is transition period where the signal is clearly nonstationary. Also as muscle fatigues, nonstationarities become more prevalent even during stable postures. So, it requires a develpment of time varying nonstationary EMG signal identifier. In this paper, time varying nonstationary EMG signals are transformed into DCT domain and the transformed EMG signals are modeled and analyzed in the transform domain. In the DCT domain, we verified reduction of condition number and increment of the smallest eigenvalue of input correlation matrix that influences numerical properties and mean square error were compared with SLS algorithm, and the proposed algorithm is implemented using IMS T-805 parallel processing computer for real time application.

  • PDF