• 제목/요약/키워드: 자기공명영상(MRI)

검색결과 1,160건 처리시간 0.044초

정형보철용 금속이 자기공명영상에 미치는 영향 I (Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I)

  • 김형균;최성대
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.46-50
    • /
    • 2012
  • Stainless steel and titanium used for orthopedic prosthetic metal, magnetic resonance imaging was measured quantitatively the extent of distortion. Based on reading tests at varying metal magnetic resonance imaging (MRI) were investigated. To two image acquisition conditions for having three metal bodies mutually quantitative it compared analyzed the image of cross direction and the image of lengthwise. As for the distortion of the magnetic resonance image, as for the distortion of image it became small in the order of Clip, Strainless and Titanium. In addition, with T1WI and T2WI which are image acquisition condition T2WI the distortion of image became small. As for the distortion of the image by the metal, you could see the distortion of image in elliptical shape, the metal a bigger image distortion appeared in many parts. If clinical doctor has the condition of the same operation, use the Titanium material, it can, raising the diagnostic value of magnetic resonance image inspection after the operating from Stainless.

두개골의 랑게르한스 세포 조직구증: 자기공명영상과 다른 영상과의 비교 (Langerhans Cell Histiocytosis in the Skull: Comparison of MR Image and Other Images)

  • 임수진;임명관;박선원;김정은;김지혜;김덕환;이석룡;서창해
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권1호
    • /
    • pp.74-80
    • /
    • 2009
  • 목적: 이 연구의 목적은 두개골 랑게르한스 세포 조직구증의 특징적인 자기공명 영상소견을 기술하고 단순촬영과 컴퓨터 단층 촬영에서의 영상소견과 비교함에 있다. 대상 및 방법: 총 9명의 환자 중 10예의 병변을 대상으로 자기공명 영상을 분석하였다(연령범위: 5-42세, 평균 연령: 18세, 전예 여자). 9예에서 수술이나 미세 침 흡입 생검술에 의해서 병리학적으로 두개골의 랑게르한스 세포 조직구증이 증명되었다. 모든 환자는 자기공명영상을 시행하였고 이 중 7명 (8예) 에서 컴퓨터 단층 촬영과 단순 촬영을 시행하였다. 두 명의 숙련된 신경영상의학 의사가 영상에서 병변의 위치, 크기, 모양과 특징을 독립적으로 분석하고 병변의 범위와 주변 조직으로의 침범 여부를 비교하였다. 결과: 병변은 모든 두개골에 편향 없이 분포하였다. 자기공명 영상에서 종괴들은 조영증강되는 골 융해성 종괴(10/10)로 주로 판사이 공간에 위치하고(8/10) 두피(9/10)나 경질막(7/10)을 침범하였다. 경질막의 조영증강(7/10)과 비후(4/10)가 모든 병변에서 보였다. 골 융해성 종괴의 크기는 1.1 cm에서 6.8 cm의 범위였으며 모양은 원형(5/10)이거나 난원형(5/10)이었다. 컴퓨터 단층 촬영에서 병변은 판사이 공간의 골 융해성 종괴로(6/8) 두피의 침범(7/8)이 잘 보였다. 컴퓨터 단층촬영에서 골미란이나 골파괴가 자기공명영상보다 좀 더 분명하게 보였지만 연부종괴와 경질막의 조영증강 유무는 판단하기 어려웠다. 이와 대조적으로 단순촬영에서 모든 랑게르한스 세포 조직구증은 도려낸 병터 (punched out) 모양(4/8)이나 beveled-edge 모양(4/8)의 골융해성 종괴로 보였고 두피나 경질막으로의 침범은 판단 할 수 없었다. 결론: 두개골 랑게르한스 세포 조직구증의 특징적인 자기공명 영상소견은 판사이 공간에 위치한 골 융해성 종괴가 경질막과 두피를 침범하는 것으로, 자기공명영상이 단순촬영이나 컴퓨터 단층 촬영 보다 우월한 영상 기법이다.

  • PDF

신경망의 결정론적 이완에 의한 자기공명영상 분류 (Classification of Magnetic Resonance Imagery Using Deterministic Relaxation of Neural Network)

  • 전준철;민경필;권수일
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권2호
    • /
    • pp.137-146
    • /
    • 2002
  • 목적: 본 논문에서는 신경망을 이용한 자기공명영상의 분류에 있어 결정론적 이완 방법(deterministic relaxation)과 응집 군집화(agglomerative clustering) 방법에 의한 개선된 영상 분류방법을 제시한다. 제안된 방법은 신경망을 이용한 영상의 분류시 지역적 최소치로의 수렴문제와 입력 패턴의 증대로 인하여 수렴 속가 늦어지는 문제를 해결한다. 대상 및 방법: 신경망을 이용한 영상의 분류는 지역적 계산과 병렬 계산이 가능한 특성을 갖고 있어 기존의 통계적 방법을 대신하는 방법으로 주목을 받고 있다. 그러나 일반적으로 신경망에 의한 분류알고리즘이 지닌 문제점의 하나는 에너지함수가 항상 전역적 최소치로 수렴하지 않고 지역적 최소치로도 수렴할 수 있다는 점이고, 또 다른 문제점은 반복수렴을 수행하는 에너지함수의 수렴속도가 너무 늦다는 점이다. 따라서 지역적 최소치로의 수렴을 방지하고 전역적 최소치로의 수렴속도를 가속화시키기 위하여 본 논문에서는 결정적 이완 알고리즘의 하나인 MFA(Mean Field Annealing) 방법을 적용하여 지역적 최소치로의 수렴문제를 해결하는 방법을 제시한다. MFA는 모의 애닐링의 통계적 성질을 변수의 평균값에 적용하는 결정론적인 수정 법칙들로 대신하고, 이러한 평균값을 최소화함으로서 수렴속도를 개선한 방법이다 아울러 신경망이 갖고 있는 문제점인 과다한 클래스 패턴의 생성에 따른 처리속도 지연의 문제점을 해결하기 위하여 응집 군집화 알고리즘을 이용하여 영상을 구성하는 군집을 결정하여 신경망에 입력되는 값을 초기화하여 영상패턴이 증가되는 것을 제한하였다. 결과: 본 논문에서 제시된 응집 군집화 방법 및 결정론적 이완 방법은 신경망에 의한 자기공명영상의 분류 시 발생할 수 있는 지역적 최적 치로의 수렴 문제를 해결하여 전역적 최적화로 신속히 수렴함을 알 수 있었다. 결론: 본 논문에서는 클러스터의 분석과 결정론적 이완 방법에 의하여 신경망에 의한 자기공명영상의 분류결과를 향상시키기 위한 새로운 방법을 소개하였으며 실험결과를 통하여 그러한 사실을 확인할 수 있었다.

  • PDF

휴식상태 EEG-to-MRI 크로스 모달리티 변환을 위한 스펙트로그램 기반 딥러닝 기법에 관한 예비 연구 (A Feasibility Study on Spectrogram-based Deep Learning Approach to Resting State EEG-to-MRI Cross-Modality Transfer)

  • 이규석;마히마 아리아;유원상
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 춘계학술발표대회
    • /
    • pp.13-14
    • /
    • 2023
  • 뇌의 전기적 신경활동을 측정하는 뇌전도(EEG)는 저렴하게 취득할 수 있고 높은 시간 해상도를 갖는 반면 공간적 정보를 제공하지는 않는다. 기능적 자기공명영상(fMRI)은 혈류변화를 감지하여 뇌활동을 측정하는 방식으로서 높은 공간 분해능을 갖지만 고가의 비용과 설비를 요구한다. 최근 저렴하게 취득할 수 있는 EEG 데이터로부터 딥러닝을 사용하여 fMRI 합성영상을 생성하는 기술이 제안되었지만, 저주파수 대역에서 EEG와 fMRI 간의 뇌과학적 상관관계를 반영하지는 않는다. 본 연구에서는 휴식상태에서 취득된 EEG 데이터를 스펙트로그램으로 변환한 후 저주파수 특성을 사용하여 fMRI 합성영상을 생성하는 U-net 기반의 크로스 모달리티 변환 모델의 실현가능성을 평가하였다.

CHESS 기법을 이용한 지방소거 경추 자기공명영상에서 자화감수성 인공물을 줄이기 위한 연구 (A Study on the Reduction of the Magnetic Susceptibility Artifact in MRI of the Cervical Spine with Chemical Shift Selective Fat Suppression)

  • 임우택;정홍량
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2014년도 추계 종합학술대회 논문집
    • /
    • pp.197-198
    • /
    • 2014
  • CHESS(chemical shift selective saturation) 기법을 이용한 경추 자기공명영상에서 주로 나타나는 자화 감수성 인공물(susceptibility artifact)을 줄이기 위한 보조물질을 찾고자 하였다.

  • PDF

3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가 (Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

급성 전방십자인대 손상 시 자기공명영상에서 나타나는 골멍과 전방십자인대 손상 정도의 관계 (The Relationship between Bone Bruise in MR-Imaging and the Degrees of Acute Anterior Cruciate Ligament Injury)

  • 정화재;신헌규;고천석;김장환
    • 대한관절경학회지
    • /
    • 제16권1호
    • /
    • pp.17-25
    • /
    • 2012
  • 목적: 급성 전방십자인대 손상 환자의 자기공명영상(magnetic resonance imaging, MRI)에서 나타난 골멍의 형태 및 크기와 전방십자인대의 손상 정도와의 관계를 알아보고 골멍의 발자취(footprint)를 조사해 손상기전을 알아보고자 하였다. 대상 및 방법: 급성 전방십자인대 손상 6주 이내의 급성기에 자기공명영상을 촬영하여 골멍이 나타나는 65명을 대상으로 하였다. 골멍의 형태는 Costa-Paz 분류에 따라, 골멍의 크기는 Kornaat의 방식으로 측정하였다. 자기공명영상의 전방십자인대 관상사면영상(anterior cruciate ligament [ACL] oblique coronal view)에서 손상 정도를 등급화 하였다. 결과: Costa-Paz 분류에 따른 대퇴골 외과의 골멍 형태와 전방십자인대 손상 정도의 관계를 알아본 결과, 부분 파열군(1, 2 등급)에서 제2형이 많고, 완전 파열군(3 등급)에서 제3형이 많았다(P=0.037). Kornaat 총 골멍 점수는 전방십자인대 손상 등급에 따라 차이를 보였으며(P=0.014), 손상기전은 축회전 손상(pivot shift injury)이 가장 많았고 편타 외반 손상 (clip valgus injury) 등이 뒤를 이었다. 결론: 급성 전방십자인대 손상 시 골멍의 형태와 크기는 전방십자인대의 손상 정도와 관련이 있었고, 골멍의 발자취를 통해 손상기전을 유추할 수 있어 급성 전방십자인대 손상의 진단 및 치료에 도움이 되리라 사료된다.

  • PDF

말티즈 견의 견갑부에서 발생한 섬유육종 (Fibrosarcoma in the Scapula of a Maltese Dog)

  • 이재훈;정다정;강은희;장화석;최치봉;유치호;서정향;김휘율
    • 한국임상수의학회지
    • /
    • 제25권2호
    • /
    • pp.126-130
    • /
    • 2008
  • 6연령의 말티즈 견이 오른쪽 견갑부의 종괴로 내원하였다. 신체검사와 자기공명영상(MRI)의 평가, 전체혈구 계산 (CBC), 혈청화학검사, 미세흡인 생검(FNA), 조직학적인 평가가 이루어졌다. 전체혈구계산 검사에서는 정상범위를 나타내었으며, 혈청화학 검사상에서는 ALP의 증가를 보였다. 방사선 소견에서 견갑골의 완전한 골 융해 소견을 보였으며, 자기공명영상에서는 혼재된 신호강도를 보였다. 면역조직화학(염색과 Masson's trichrome 염색) 소견에 근거하여, 섬유육종으로 최종진단 되었다.

악관절증의 진단을 위한 역동적 자기공명 영상의 이용 및 증례 (Diagnostic Reliability & Case Reports Of The Dynamic MRI For Temporomandibular Joint Disease)

  • 박진호;진병로;변우목
    • Journal of Yeungnam Medical Science
    • /
    • 제12권1호
    • /
    • pp.141-148
    • /
    • 1995
  • 본 교실에서는 측두하악관절주위의 동통, 관절 잡음동의 증상을 주소로 내원한 환자들에 있어서 역동적 자기공명영상의 촬영을 시행하여 관절원판의 전방변위와 형태적 이상 및 주위 구조물들과의 관계를 분석한 결과 근육성 동통기능장애와의 감별뿐만 아니라 환자의 중상에 따른 관절 내부 장애의 정도를 파악할 수 있었으며 악기능시의 구조적 이상, 장애의 원인 등을 판독하여 치료의 방침을 세우는데 있어 매우 유용한 정보를 얻을 수 있었기에 보고 하는 바이다.

  • PDF

자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원;한지현;이시내;김민지;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.