• Title/Summary/Keyword: 자기검사회로

Search Result 14, Processing Time 0.028 seconds

A Study on Design and Reliability Assessment for Embedded Hot-Standby Sparing FT System Using Self-Checking Logic (자기검사회로를 이용한 대기이중계구조 결함허용제어기의 설계 및 신뢰도평가에 관한 연구)

  • Lee, Jae-Ho;Lee, Kang-Mi;Kim, Young-Kyu;Shin, Duc-Ko
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.725-731
    • /
    • 2006
  • Hot Standby sparing system detecting faults by using software, and being tolerant any faults by using Hardware Redundancy is difficult to perform quantitative reliability prediction and to detect real time faults. Therefore, this paper designs Hot Standby sparing system using hardware basis self checking logic in order to overcome this problem. It also performs failure mode analysis of Hot Standby sparing system with designed self checking logic by using FMEA (Failure Mode Effect Analysis), and identifies reliability assessment of the controller designed by quantifying the numbers of failure development by using FTA (Fault Tree Analysis)

A study on New Non-Contact MR Current Sensor for the Improvement of Reliability in CMOS VLSI (CMOS회로의 신뢰도 향상을 위한 새로운 자기저항소자 전류감지기 특성 분석에 관한 연구)

  • 서정훈
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.1
    • /
    • pp.7-13
    • /
    • 2001
  • As the density of VLSI increases, the conventional logic testing is not sufficient to completely detect the new faults generated in design and fabrication processing. Recently. IDDQ testing becomes very attractive since it can overcome the limitations of logic testing. This paper presents a new BIC for the internal current test in CMOS logic circuit. Our circuit is composed of Magnetoresistive current sensor, level shifter, comparator, reference voltage circuit and a circuit be IDDQ tested as a kind of self-testing fashion by using the proposed BIC.

  • PDF

Development of Magnetoimpedance Sensor Utilizing Soft Magnetic Amorphous Ribbon with Exchange Coupling and Application to Nondestructive Testing (교환결합을 가진 연자성 비정질 리본을 이용한 자기 임피던스 센서 개발과 비파괴검사 응용)

  • Yoon, Seok-Soo;Kim, Gun-Woo;Lee, Sang-Hun;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.401-406
    • /
    • 2008
  • Recently, portable magnetic sensors with high sensitivity are strongly required for various applications such as biosensor, nondestructive testing and directional sensor. A novel magnetic sensor system was developed by utilizing giant magnetoimpedance(MI) effect of soft magnetic ribbons. The sensor system consists of sensing head of $Co_{66}Fe_{4}Si_{15}B_{15}$ ribbon having asymmetric MI characteristics through exchange coupling produced by field-annealing in open air and circuit for signal processing. The sensor system showed almost linear characteristics in dynamic range of $-1\;Oe\;{\sim}\;1\;Oe$ and sensitivity of 10.5 V/Oe. The sensor was applicable to nondestructive testing system to detect defects in wire ropes.

The Effects of The concentration Program Based on Acceptance-Commitment Therapy with High School Students (수용전념치료 기반 집중력프로그램이 고등학생들의 집중력 증가에 미치는 효과)

  • Lee, JeongHwa;Son, ChongNak
    • Journal of Digital Convergence
    • /
    • v.13 no.12
    • /
    • pp.277-284
    • /
    • 2015
  • The purpose of the this study was to evaluate the effects of self-Control, avoidance cognitive fusion, concentration and learning attitude with high school students. For this, the group acceptance-commitment therapy programs were administered for 12 sessions on a weekly basis. 10 high school students were assigned to treatment group and 10 were assigned to control group. Both pre- post- follow-up of self-Control, avoidance cognitive fusion, concentration and learning attitude were assessed. The results were as the treatment group reported significantly lower avoid fusion to the control group. In addition, the treatment group reported significantly higher score level of self-Control, concentration and learning attitude compared to control. Results indicate that the treatment group is more capable than the control group, of decreasing avoid fusion, while increasing self-Control, concentration and learning attitude. This results suggest that can be applied effectively. Finally, limitations of the present study and suggestions were discussed.

Improvement of Signal Processing Circuit for Inspecting Cracks on the Express Train Wheel (고속 신호처리 회로에 의한 고속철도 차륜검사)

  • Hwang, Ji-Seong;Lee, Jin-Yi;Kwon, Suk-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.579-584
    • /
    • 2008
  • A novel nondestructive testing (NDT) system, which is able to detect a crack with high speed and high spatial resolution, is urgently required for inspecting small cracks on express train wheels. This paper proposes an improved signal processing circuits, which uses the multiple amplifying circuits and the crack indicating pulse output system of the previous scan-type magnetic camera. Hall sensors are arrayed linearly, and the wheel is rotated with static speed in the vertical direction to sensor array direction. Each Hall voltages are amplified, converted and immediately operated by using, amplifying circuits, analog-to-digital converters and $\mu$-processor, respectively. The operated results, ${\partial}V_H/{\partial}t$, are compared with a standard value, which indicates a crack existence. If the ${\partial}V_H/{\partial}t$ is larger than standard value, the pulse signal is output, and indicates the existence of crack. The effectiveness of the novel method was verified by examine using cracks on the wheel specimen model.

  • PDF

A Study of the Exclusive Embedded A/D Converter Using the Microprocessor and the Noise Decrease for the Magnetic Camera (마이크로프로세서를 이용한 자기카메라 전용 임베디드형 AD 변환기 및 잡음 감소에 관한 연구)

  • Lee, Jin-Yi;Hwang, Ji-Seong;Song, Ha-Ryong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.99-107
    • /
    • 2006
  • Magnetic nondestructive testing is very useful far detecting a crack on the surface or near of the surface of the ferromagnetic materials. The distribution of the magnetic flux leakage (DMFL) on a specimen has to be obtained quantitatively to evaluate the crack. The magnetic camera is proposed to obtain the DMFL at the large lift-off. The magnetic camera consists of a magnetic source, magnetic lens, analog to digital converters (ADCs), interface, and computer. The magnetic leakage fields or the distorted magnetic fields from the object, which are concentrated on the magnetic lens, are converted to analog electrical signals tv arrayed small magnetic sensors. These analog signals are converted to digital signals by the ADCs, and are stored, imaged, and processed by the interface and computer. However the magnetic camera has limitations with respect to converting and switching speed, full range and resolution, direct memory access (DMA), temporary storage speed and volume because common ADCs were used. Improved techniques, such as those that introduce the operational amplifier (OP-Amp), amplify the signal, reduce the connection line, and use the low pass filter (LPF) to increase the signal to noise ratio are necessary. This paper proposes the exclusive embedded ADC including OP-Amp, LPF, microprocessor and DMA circuit for the magnetic camera to satisfy the conditions mentioned above.

A Study on Effects of the vocal psychotherapy upon Self-Consciousness (성악심리치료활동을 통한 자기의식 변화에 관한 연구)

  • Lee, Hyun Joo
    • Journal of Music and Human Behavior
    • /
    • v.4 no.2
    • /
    • pp.66-83
    • /
    • 2007
  • The purpose of this study is to learn both effects of the vocal psychotherapy on the self-consciousness and the variety of the self-consciousness on the vocal psychotherapy in return. The research for this study was performed to three subjects who were students of E university, Seoul, ten times for sixty minutes. The subjects were all volunteers for the advertisement on a music-therapy program searching for them on the web site of E university. The vocal psychotherapy program consists of four steps and each of them consists of two to four short terms again. Both before and after the experiment, examinations on self-consciousness were done to recognize the change of the subjects' self-consciousness which would be caused by the vocal psychotherapy activity. After every short term, the subjects were asked to write reports to closely analyze the change of self-consciousness according to the terms and the variety of the subjects. The effect of the vocal psychotherapy activity on the changes of scores in the self-consciousness examination is the first thing to point out on this study. There appeared some personal varieties on the total scores of the examination and scores of some sub-categories. Especially, there were different scores on the private self-consciousness, the public self-consciousness, and the social anxiety between before and after performing the vocal psychotherapy program. Subject A, who had got the best score of all on the scope of the private self-consciousness, showed the steepest decrease on the very scope. On the contrary, the subject showed decrease of scores of the public self-consciousness and the social anxiety in the relatively little rate. Subject B, who had got the highest score of the three on the public self-consciousness, showed the steepest decrease on that of all scopes and showed no difference on the social anxiety scope. In the case of the last one, subject C, who had relatively low scores on the private and public self-consciousness than the others, the private self-consciousness score increased but the public self-consciousness and the social anxiety scores decreased. The changes of the scores of each questions were examined in order to see possible other changes that had not been exposed on the changes of the total and sub-categories scores. As a result of that, of all twenty-eight questions, there were changes about one to two points. Subject A showed the difference with thirteen questions, subject B with sixteen and subject C with nineteen questions. The rate of change of subject C was relatively small but more questions changed and the change of score was wider than the others. Considering all those results, It can be possibly said that the vocal psychotherapy affects the changes of the scores of sub-categories in self-consciousness examination. The next thing to point out on this study is the change of recognition that was exposed on the subjects' report after every short term of the program. As a result of the close analyzing, according to the short terms and variety of self-consciousness, recognizing the way express subjects themselves by voice and recognizing their own voices appeared to be different. How much they cared about others and why they did so were also different. According to the self reports, subject A cared much about her inner thought and emotion and tended to concentrate herself as a social object. There appeared some positive emotional experiments such as emotional abundance and art curiosities on her reports but at the same time some negative emotions such as state-trait anxiety and neuroticism also appeared. Subject B, who showed high scores on the private and public self-consciousness like subject A, had a similar tendency that concentrates on herself as a social object but she showed more social anxiety than subject A. Subject C got relatively lower points in self-consciousness examination, tended to care about herself, and had less negative emotions such as state-trait anxiety than other subjects. Also, with terms going on, she showed changes in the way of caring about her own voice and others. This study has some unique significances in helping people who have problems caused by self-estimation activated with self-consciousness, using voices closely related to one's own self, performing the vocal skills discipline to solve the technical problems. Also, this study has a potentiality that the vocal psychotherapy activity can be effectively used as a way affects the mental health and developing personality.

  • PDF

Functional MRI of Visual cortex in the Patients with Occipital Lobe Ischemia (후두엽의 허혈성 뇌졸중 환자에서 시각피질의 기능적 자기공명영상)

  • 이영준;정태섭;윤영수;한승한;조영재;배준호
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.173-178
    • /
    • 1999
  • Purpose : To evaluate the usefulness of functional MRI (fMRI) of visual cortex in patients with ischemic infarction in the occipital lobe. Materials and Methods : Four patients with the symptoms and signs of visual cortical ischemia were included. Functional MRI was performed by 2D-FLASH technique with the parameter of 90/56msec TR/TE, $40^{\circ}$ flip angle, $240{\times}240{\;}FOV,{\;}64{\times}128$ matrix number, 8.32 seconds acquisition time, 8mm slice thickness. An axial slice including both visual cortices was selected and alternative activation and resting of the visual cortex was performed using red color photostimulator. all patients undertook visual field test, and vascular abnormality was examined by MRA (n=4) and DSA (n=2). fMRI results were compared with the results of a visual field test, conventional MRI and cerebral angiography. Results : On fMRI, decreased activity of the visual cortex was found in the occipital lobe corresponding to stenosis of the posterior cerebral artery or its branch noted on angiogram. However, 2 of 4 patients showed no abnormal findings on conventional MRI. Visual field defect was noted in 3 patients, one and of whom showed no abnormality on conventional MRI and diffusion-weighted image, but revealed decreased activity in the corresponding visual cortex on fMRI. Conclusion : fMRI may be a sensitive method for detection of the status of decreased blood flow or vascular reserve which other methods can not.

  • PDF

Empirical Characterization of an Air-cored Induction Coil Sensor using Constructional Parameters (Air-cored induction 코일 센서의 실험 기반 고주파 특성 모델링에 대한 연구)

  • Lim, Han-Sang;Kim, In-Joo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • This paper presents empirical equations indicating the high frequency performance characteristics of air-cored induction coil sensors with their constructional parameters. An air-cored induction coil sensor is widely used due to good linearity at low frequency ranges but the sensor has weakness of relatively low sensitivity to the magnetic field. At high frequency ranges, the sensitivity can be dramatically increased, largely depending on the frequency of the injected field, and this property can be a great asset to some electromagnetic inspections, since they utilize the interrogating current with a fixed frequency. The application of this property of the coil sensor requires the estimation of its high frequency performance. We made experiments on the frequency responses of the coil sensors under diverse constructional conditions and, on the basis of the experimental results, the high frequency performance, such as the resonant frequency and the sensitivity at the frequency, was estimated, as a function of the constructional parameters of the coil sensor. The good agreements between experimental and estimated data were reported.

Implementation of High Reliable Fault-Tolerant Digital Filter Using Self-Checking Pulse-Train Residue Arithmetic Circuits (자기검사 Pulse별 잉여수연산회로를 이용한 고신뢰화 Fault Tolerant 디지털필터의 구성에 관한 연구)

  • 김문수;손동인;전구제
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.2
    • /
    • pp.204-210
    • /
    • 1988
  • The residue number system offers the possibility of high-speed operation and error detection/correction because of the separability of arithmetic operations on each digit. A compact residue arithmetic module named the self-checking pulse-train residue arithmetic circuit is effectively employed as the basic module, and an efficient error detection/correction algorithm in which error detection is performed in each basic module and error correction is performed based on the parallelism of residue arithmetic is also employed. In this case, the error correcting circuit is imposed in series to non-redundant system. This design method has an advantage of compact hardware. Following the proposed method, a 2nd-order recursive fault-tolerant digital filter is practically implemented, and its fault-tolerant ability is proved by noise injection testing.

  • PDF