Purpose: Malignant Mixed Mullerian Tumor (MMMT) of the uterine corpus is one of the very uncommon and the most lethal tumors in the uterus. The aim of this study was to evaluate the role of FDG PET in detecting distant metastasis and residual and/or recurrent disease. Methods: Ten patients who underwent FDG PET for detecting distant metastasis and recurrence were included. focal FDG accumulation was regarded as abnormal. We also reviewed serum CA 125 levels, anatomical images, and histopathoiogical examination. Results: Three patients of 10 FDG PET showed abnormal FDG uptake. One had high serum CA 125 levels and high fractions of carcinomatous element on histopathologic examination. FDG PET showed metastatic lesions in unexpected locations, which could not be detected by anatomical images. Another had normal serum CA 125 levels with high sarcomatous element and CT could only detect a few lesions. The other had high serum CA 125 levels and also had high carcinomatous element. Seven patients who had no abnormal uptake on FDG PET had no clinical evidence of recurrence during the follow up period ($51.7{\pm}12.2$ months). The mean disease free intervals of these 7 patients were $36.4{\pm}6.0$ months. Two patients with abnormal findings had never become disease-free condition during the follow up period ($6.0{\pm}4.2$ months. Conclusion: FDG PET could be a useful modality for unexpected distant metastasis and follow up tool in patients with MMMT.
Kim, Dong-Heui;Teng, Yung-Chien;Yoon, Yang-Sook;Qi, Xu-Feng;Jeong, Hyun-Seok;Joo, Kyung-Bok;Lee, Kyu-Jae
Applied Microscopy
/
v.39
no.2
/
pp.133-139
/
2009
A officinal mushroom, Phellinus linteus (PL) has been known to exhibit potent biological activities including antioxidative and anticancer effect. PL is consumed as a type of powder or extract for the purpose of health promotion and disease treatment. Recently superfine PL products was commercialized according to the development of pulverizing technology such as nanomill, so the evaluation of food safety is suggested. This study was conducted to evaluate the food safety of superfine PL (SPL) through hematological, biochemical and histological examination in mice as compared with fine PL (FPL). In the particle size distribution in volume after nanomill processing, the mean diameter of SPL and FPL particles was 11.78 ${\mu}m$ and 216.1 ${\mu}m$, and d (0.5), the particle diameter measured at 50% of distribution was 5.5 ${\mu}m$ and 147.9 ${\mu}m$, respectively. As the result of body weight, food intake and the weight of organs, SPL group didn't show any statistical difference compared with FPL group and normal group (N). Hematological and biochemical values were also involved in the normal range, although ALT (N vs. FPL, P<0.001) and BUN (N vs. FPL, P<0.01; N vs. SPL, P<0.01) showed significance compared with N group but there are no significance between FPL and SPL group. In the result of histological examination with liver, kidney, spleen, and small and large intestine, abnormal findings such as inflammatory reaction and histological changes were not observed. Our results suggest that the oral intake of SPL diet is not harmful to the animal in the hematological, biochemical and histological aspects although particle size was reduced to the level of superfine. However, further study will be necessary to confirm the histological safety in relation to the gastrointestinal contact of superfine particles in the case of large amount and long-term intake.
Based on recent dramatic increases in foodborne outbreaks in restaurants, self-managed sanitation systems are now recommended to control contributing risk factors. This study aimed to improve sanitation management practices in restaurants and had two objectives. First, we tried to develop a self-managed sanitation check-list, including risk factors contributing to foodborne illness and Korean food hygiene regulation articles. We also tried to evaluate current sanitation management practices in restaurants according to operation and restaurant type. Thirty restaurants were evaluated by on-the-spot inspectors using an auditing tool consisting of four dimensions, seventeen categories, and forty-one items. Total compliance rate categorized by operation type significantly differed between chain restaurants and self-managed restaurants, with values of 85.5% and 51.6%, respectively. Therefore, self-managed restaurants, which showed the lowest compliance rate of below 30.0%, need more strict control to improve current unsanitary management practices, specifically relating to 'sterilization of knives, chopping boards, and wiping cloths', 'sanitation training', 'not allowing access into the kitchen to outsiders', 'handling of food or utensils on shelves at a 15 cm distance away from floor', 'prevention of cross-contamination of cooked foods or vegetables', and 'records of kitchen access or inspection'. Thus, an effective food sanitation system is essential and should be implemented to improve the existing sanitary conditions in restaurants. However, the most important factor to achieving food sanitation management objectives is food handlers' self-motivation.
Journal of The Korean Society of Grassland and Forage Science
/
v.29
no.3
/
pp.253-262
/
2009
The present study was conducted to develop a rapid and accurate method of evaluating chemical composition of total mixed ration (TMR) for dairy cows using near infrared reflectance spectroscopy (NIRS). A total of 253 TMR samples were collected from TMR manufacturers and dairy farms in Korea. Prior to NIR analysis, TMR samples were dried at $65^{\circ}C$ for 48 hour and then ground to 2 mm size. The samples were scanned at 2 nm interval over the wavelength range of 400-2500 nm on a FOSS-NIR Systems Model 6500. The values obtained by NIR analysis and conventional chemical methods were compared. Generally, the relationship between chemical analysis and NIR analysis was linear: $R^2$ and standard error of calibration (SEC) were 0.701 (SEC 0.407), 0.965 (SEC 0.315), 0.796 (SEC 0.406), 0.889 (SEC 0.987), 0.894 (SEC 0.311), 0.933 (SEC 0.885) and 0.889 (SEC 1.490) for moisture, crude protein, ether extract, crude fiber, crude ash, acid detergent fiber (ADF) and neutral detergent fiber (NDF), respectively. In addition, the standard error of prediction (SEP) value was 0.371, 0.290, 0.321, 0.380, 0.960, 0.859 and 1.446 for moisture, crude protein, ether extract, crude fiber, crude ash, ADF and NDF, respectively. The results of the present study showed that the NIR analysis for unknown TMR samples would be relatively accurate. Use of the developed NIR calibration curve can obtain fast and reliable data on chemical composition of TMR. Collection and analysis of more TMR samples will increase accuracy and precision of NIR analysis to TMR.
This study aimed to develop a modular smart clothing system for heart rate monitoring that reduces the inconvenience caused by battery charging and the large size of measurement devices. The heart rate monitoring system was modularized into a temporary device and a continuous device to enable heart rate monitoring depending on the requirement. The temporary device with near-field communication (NFC) and heart rate sensors was developed as a clothing attachment type that enables heart rate monitoring via smart phone tagging when required. The continuous device is based on Bluetooth Low Energy (BLE) communication and batteries and was developed to enable continuous heart rate measurement via a direct connection to the temporary device. Furthermore, the temporary device was configured to connect with a textile electrode made of a silver-based knitted fabric designed to be located below the pectoralis major muscle for heart rate measurement. Considering the user-experience factors, key functions, and the ease of use, we developed an application to automatically log through smart phone tagging to improve usability. To evaluate the accuracy of the heart rate measurement, we recorded the heart rate of 10 healthy male subjects with a modular smart clothing system and compared the results with the heart rate values measured by the Polar RS800. Consequently, the average heart rate value measured by the temporary system was 85.37, while that measured by the reference device was 87.03, corresponding to an accuracy of 96.73%. No significant difference was found in comparison with the reference device (T value = -1.892, p = .091). Similarly, the average heart rate measured by the continuous system was 86.00, while that measured by the reference device was 86.97, corresponding to an accuracy of 97.16%. No significant difference was found in terms of the heart rate value between the two signals (T value = 1.089, p = .304). The significance of this study is to develop and validate a modular clothing system that can measure heart rates according to the purpose of the user. The developed modular smart clothing system for heart rate monitoring enables dual product planning by reducing the price increase due to unnecessary functions.
Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
The Korean Journal of Nuclear Medicine Technology
/
v.20
no.2
/
pp.32-35
/
2016
Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.
For many rears, traffic accident statistics are the most direct measure of safety for a signalized intersection. However it takes more than 2 or 3 yearn to collect certain accident data for adequate sample sizes. And the accident data itself is unreliable because of the difference between accident data recorded and accident that is actually occurred. Therefore, it is rather difficult to evaluate safety for a intersection by using accident data. For these reasons, traffic conflict technique(TCT) was developed as a buick and accurate counter-measure of safety for a intersection. However, the collected conflict data is not always reliable because there is absence of clear criteria for conflict. This study developed objective and accurate conflict criteria, which is shown below based on traffic engineering theory. Frist, the rear-end conflict is regarded, when the following vehicle takes evasive maneuver against the first vehicle within a certain distance, according to car-following theory. Second, lane-change conflict is regarded when the following vehicle takes evasive maneuver against first vehicle which is changing its lane within the minimum stopping distance of the following vehicle. Third, cross and opposing-left turn conflicts are regarded when the vehicle which receives green sign takes evasive maneuver against the vehicle which lost its right-of-way crossing a intersection. As a result of correlation analysis between conflict and accident, it is verified that the suggested conflict criteria in this study ave applicable. And it is proven that estimating safety evaluation for a intersection with conflict data is possible, according to the regression analysis preformed between accident and conflict, EPDO accident and conflict. Adopting the conflict criteria suggested in this study would be both quick and accurate method for diagnosing safety and operational deficiencies and for evaluation improvements at intersections. Further research is required to refine the suggested conflict criteria to extend its application. In addition, it is necessary to develope other types of conflict criteria, not included in this study, in later study.
Journal of the Korean Society of Food Science and Nutrition
/
v.33
no.8
/
pp.1279-1285
/
2004
To evaluate the antimutagenic effect and hepato protective of bamboo trees and bamboo byproduct, hot-water extracts from four kinds of bamboo [wang-dae (Phyllostachys bambusoides S. et Z.), som-dae (Phyllostachys nigra var. henonis), maengjong-juk (Phyllostachys pubescens) and o-juk (Phyllostachys nigra Munro)] and maengjong-juk extract coated rice were evaluated for antimutagenicity by Ames test using Salmonella typhimurium TA100. Bamboo extracts showed strong antimutagenic activity in the Ames test which MNNG was used as mutagen in the absence and presence of S9 mix. Maengjong-juk extract coated rice diet suppressed the loss of body weight significantly. Food intake was increased in maengjong-juk extract coated rice supplemented group but showed no significant differences between control and maengjong-juk extract coated rice diet groups. Food efficiency of maengjong-juk extract coated rice supplemented group was significantly higher than that of the control group. Liver weight was significantly increased by maengjong-juk extract coated rice diet administration. Plasma GOT & GPT activities of rabbit were significantly suppressed in maengjong-juk extract coated rice supplemented group. These results suggest that bamboo trees extracts and maengjong-juk extract coated rice are bioavailable resource on treatment of cardiovascular disease, such as atherosclerosis and hypercholesterolemia.
Purpose: Radiation adaptive response in human peripheral lymphocytes and mouse bone marrow cells was investigated using both metaphase analysis and micronucleus assay. We assessed the correlation between both tests. Materials and Methods: Two groups of the human peripheral lymphocytes and mouse bone marrow cells were exposed to low dose (conditioning dose, 0,18 Gy) or high dose (challenging dose, 2 Gy) ${\gamma}$-rays. The other 4 groups were exposed to low dose followed by high dose after several time intervals (4, 7, 12, and 24 hours, respectively). The frequencies of chromosomal aberrations in metaphase analysis and micronuclei in micronucleus assay were counted. Results: Chromosomal aberrations and micronuclei of preexposed group were lower than those of the group only exposed to high dose radiation. Maximal reduction in frequencies of chromosomal aberrations were observed in the group to which challenging dose was given at 7 hour after a conditioning dose (p<0.001). Metaphase analysis and micronucleus assay revealed very good correlation in both human lymphocytes and mouse bone marrow cells (r=0.98, p<0.001 ; r=0.99, p=0.001, respectively). Conclusion: Radiation adaptive response could be induced by low dose irradiation in both human lymphocytes and mouse bone marrow cells. There was a significant correlation between metaphase analysis and micronucleus assay.
Purpose: Scintimammography is one of the screening tests for the early diagnosis of breast cancer. It has been widely accepted as very useful in assessing masses that have not been detected in breast scanning. This method is highly sensitive and specific with respect to the diagnosis of primary and relapsing breast cancer. It has some difficulties, however, in detecting tumors sized 1 cm and below due to the radioactivity around the breast and the geometrical structure of the equipment. The recent introduction of high-resolution Breast-specific Gamma Imaging (BSGI) has made it possible to more accurately discriminate between malignant and benign tumors than with any other test method. Thus, the possibility of an unnecessary biopsy being performed has decreased. The purpose of this study was to examine the diagnostic capacity of mammography, breast sonography, and scintimammography, which are used for the early diagnosis of known breast cancer, and of BSGI, and to evaluate the skillfulness of radiologists. Materials and Methods: The 53 volunteers participants who had no clinical manifestation of breast cancer underwent the BSGI in February 2009. In the BSGI procedure, scanning images were obtained from the craniocaudal projection (CC) and the mediolateral Oblique projection (MLO), as well as from the additional $80{\times}80$-matrix-sized views at various angles in the Present Time method, 10 minutes after the 25 mCi $^{99m}Tc$-MIBI was injected. Results: The results of the BSGI showed that two participants had masses in their breast tissue. As the results of the diagnosis of four participants were not clear, they were retested and the results of the second test were negative. The results of the clinical screening test for breast cancer showed that the sensitivity of BSGI, scintimammography, mammography, and breast sonography was 86.5%, 77.8%, 85~90%, and 66.7%, respectively, and that their specificity was 92.4%, 84.2%, 20~42%, and 68%, respectively. Conclusion: The autodiagnosis and breast cancer screening test are needed for the early diagnosis of breast cancer. It was not easy, however, to accurately determine the presence of a mass in the breast using the existing breast cancer screening test. The patients with unclear test findings were made to undergo a histologic biopsy for a more accurate diagnosis. It is expected that the BSGI can provide useful information for the early diagnosis of breast cancer and of primary breast cancer, and will reduce the performance of unnecessary biopsies because of its higher sensitivity and specificity than existing breast cancer screening tests.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.