• Title/Summary/Keyword: 잉여

Search Result 742, Processing Time 0.026 seconds

An Efficient Packet Scheduling Scheme to support Real-Time Traffic in OFDMA Systems (OFDMA 시스템에서 실시간 트래픽 전송을 위한 효율적 스케쥴링 기법)

  • Park, Jeong-Sik;Cho, Ho-Shin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.1A
    • /
    • pp.13-23
    • /
    • 2007
  • In this paper, a packet scheduling scheme that supports real-time traffic having multi-level delay constraints in OFDMA systems is proposed. The proposed scheme pursues to satisfy the delay constraint first, and then manage the residual radio resource in order to enhance the overall throughput. A parameters named tolerable delay time (TDT) is newly defined to deal with the differentiated behaviors of packet scheduling according to the delay constraint level. Assuming that the packets violating the delay constraint are discarded, the proposed scheme is evaluated in terms of the packet loss probability, throughput, channel utilization. It is then compared with existing schemes for real-time traffic support such as the Exponential Scheduling (EXP) scheme, the Modified Largest Weighted Delay First (M-LWDF) scheme, and the Round robin scheme. The numerical results show that the proposed scheduling scheme performs much better than the aforementioned scheduling schemes in terms of the packet loss probability, while slightly better in terms of throughput and channel utilization.

The Effective Wind Velocity and the Patterns of Morphological Change in the Coastal Dune Area (해안사구에서의 유효풍속과 지형변화)

  • Sea, Jong-Cheol
    • Journal of the Korean association of regional geographers
    • /
    • v.10 no.3
    • /
    • pp.667-681
    • /
    • 2004
  • This research is aimed to investigate the relationship of the effective wind velocity and the morphological change in coastal dune at Sindu-ri in Korea. Sediment flux was estimated by the measurement of elevation change along eight transects deployed in the study area from July 1999 to July 2000. The results of this study indicated that. first. based on the occurrence of morphological change and winds effective for sand movement. two distinct seasons were identified: a season of deposition and that of erosion. During the depositional season, spanning from November to April, effective winds were dominant and sand accumulation occurred mainly in foredunes and sequentially in dune plains. During the erosional season, from May through October, volume change was small and erosion or sand loss occurred mostly at the dunefoot of foredunes. Secondly, the research revealed that the sediment budget of Sindu coastal dune turned out to be surplus on the whole, but there are some regional differences. Deficit budgets were observed partly in secondary dunes. The utmost northern part of Sindu coastal dune was provided with abundant sand, whereas the central and northern parts were poorly supplied.

  • PDF

Design & Implementation of Flight Software Satellite Simulator based on Parallel Processing (병렬처리 기반의 위성 탑재소프트웨어 시뮬레이터 설계 및 개발)

  • Choi, Jong-Wook;Nam, Byeong-Gyu
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.2
    • /
    • pp.80-86
    • /
    • 2012
  • The software-based satellite simulator has been developed from the start of the project to resolve the restriction and limitation of using hardware-based software development platform. It enables the development of flight software to be performed continuously since initial phase. The satellite simulator emulates the on-board computer, I/O modules, electronics and payloads, and it can be easily adapted and changed on hardware configuration change. It supports the debugging and test facilities for software engineers to develop flight software. Also the flight software can be loaded without any modification and can be executed as faster than real-time. This paper presents the architecture and design of software-based GEO satellite simulator which has hot-standby redundancy mechanism, and flight software development and test under this environment.

A Study on the Power Factor Improvement of DC Power Regenerating Systems (직류전력 회생시스템의 역률개선에 관한 연구)

  • 김경원;윤인식;서영민;윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.410-415
    • /
    • 2001
  • This paper proposes a new control scheme for the power factor improvement of DC power regenerating systems, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three-phase square-wave inverters and composed of two inverters, zig-zag connected output transformers, and an AC filter. The output voltages of the regenerating system are not sinusoidal. However, regenerated complex power is analyzed on the basis of fundamental components and thus the reactive power produced by harmonics is not considered. Therefore, it is needed a new control scheme capable of controlling the reactive power nearly to zero even for nonsinusoidal cases. To verify the validity of the proposed control scheme, computer simulations are carried out. And the results show that the power factor is theoretically higher than 0.99.

  • PDF

Development of the Control Algorithm for the Small PEM Fuel Cell Stack (소형 PEM 연료전지 스택의 제어 알고리즘 개발)

  • Kim, Tae-Hoon;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.134-141
    • /
    • 2010
  • Small PEM (Proton Exchange Membrane) fuel cell systems do not require humidification and have great commercialization possibilities. However, methods for controlling small PEM fuel cell stacks have not been clearly established. In this paper, a control method for small PEM fuel cell systems using a dual closed loop with a static feedforward structure is defined and realized using a DSP (Digital Signal Processor). The fundamental elements that need to be controlled in fuel cell systems include the supply of air and hydrogen, water management inside the stack, and heat management of the stack. For small PEM fuel cell stacks operated without a separate humidifier, fans are essential for air supply, heat management, and water management of the stack. A purge valve discharges surplus water from the stack. The proposed method controls the fan using double control loops to quicken transient response of the fan thereby improving the supply rate of air. Feedback control to compensate for the voltage change in fuel cell stack improves the response characteristics in fuel cell to load variations. The feasibility of proposed method was proved by the experiments with a 60W small PEM fuel cell system and operation of a notebook computer using this system.

Application of Non-Thermal Plasma for the Simultaneous Removal of Odor and Sludge (무기악취와 슬러지 동시처리를 위한 저온플라즈마의 적용)

  • Hwang, Hyun-Jung;Ann, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2010
  • In this study, odorous compounds emitted from various wastewater treatment were treated with using the non-thermal plasma reaction, and the effluent gas from the plasma reactor was introduced to a waste sludge reactor to achieve simultaneous sludge reduction. Hydrogen sulfide, the model odorous compound, was removed at 70% using the plasma reaction, and greater than 99% removal efficiency was observed when treated by the sludge reactor. In addition, the sludge reactor showed a high efficiency of ozone removal. As ozone reacted with sludge, oxidation with organic matters took place, and total COD decreased by 50~60% and soluble COD increased gradually. As a result, the integrated process consisting of the non-thermal plasma and the sludge reactor can be successfully applied for the simultaneous treatment of malodorous gas and waste sludge.

A Study on the Fire Safety Measure of Pumped Storage Power Plant (양수발전소의 화재안전 대책에 관한 연구)

  • Kim, Yoo-Shik
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.125-130
    • /
    • 2006
  • Pumped storage power plant is a system of generating electricity with hydroelectric power, in which at times of low electrical demand such as during nights, excess generation capacity of many power plants is used to pump water into the higher reservoir, and when there is higher demand, water is released back into the lower reservoir through a turbine, generating electricity. As pumped storage power plants across the nation are not on building registry under "the Article 6 of the Special Act by the Development of Power Resources", they are classified as a structure, not as a building. As a result, permit of fire protection facility is unnecessary, and fire protection administration is excluded from approval to completion of construction. Therefore, this study is to improve problems in accordance with the application of "he Article 6 of the Special Act by the Development of Power Resources", repair of facilities and problems with safety control to effectively prevent similar damages from repeatedly happening to pumped storage power plants in operation or under construction nationwide during a fire.

A Study on Adaptive Operation Control to Stabilize bus Voltage of GEO Satellite Power Supply Module (정지궤도 위성용 전력공급 모듈의 버스 전압 안정화를 위한 최적동작 제어에 관한 연구)

  • Ahn, Tae-Young;Choe, Hyun-Su
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.123-129
    • /
    • 2016
  • In this paper, results of produced PCU(Power Control Unit) prototype was showed by suggesting and maintaining optimal operation status which let the three functional modules automatically operate with its necessity by prioritizing operation process. In order to validate effectiveness of the suggested method, we produced a test PCU and examined the results. PCU consists of S3R(Sequential Switching Shunt Regulator), BCR(Battery Charge Regulator), and BDR(Battery Discharge Regulator): converting photovoltaic power into constant voltage at linked bus voltage; storing dump power in the battery which is an auxiliary energy storage device; and supplying power charged in battery to the load. To maintain its high reliability and optimal condition of these three power conversion modules, each module operates in parallel and stable bus voltage is required to be retained at all-time due to the nature of power supply for satellite.

Analysis of Energy Saving Effect of the Residential BESS Connected to the Balcony-PV in Apartment Houses (공동주택 발코니 PV 연계 가정용 BESS의 에너지 절감 효과 분석)

  • Kim, Cha-Nyeon;Eum, Ji-Young;Kim, Yong-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.21-31
    • /
    • 2020
  • The government mandates gradually zero energy building and Photovoltaic power generation systems installed in buildings are emerging as the most realistic alternative to increase the independence rate of building energy. In this study, we propose a method to reduce the power consumption of households by increasing the PV capacity of balconies and applying the method used the charged electric power stored in batteries after sunset. In order to evaluate the electric power energy savings of the residential BESS, a balcony PV 1.2 kW and a battery pack 2 kWh were installed for 9 houses in 4 apartments in Seoul and Gyeonggi-do. The BESS is charged when the balcony PV is generated electric power, and when solar power generation is finished, it supplies power to the electric appliances connected to the load. As a result of installing the solar PV module 1.2 kW and 2 kWh class BESS for 3 households located in Seoul and Gyeonggi-do, the average electric power consumption saving rate was 40%. The reduction in electricity consumption in the case of zero generation surplus power by maximizing the utilization rate of BESS has been improved to about 53%. Therefore, in order to increase the self-sufficiency rate of electric energy in apartment houses, it is effective to increase the solar photovoltaic capacity of the balcony and apply the residential BESS. In the future, it is believed that the balcony PV and home BESS will play a key role in achieving mandatory zero-energy housing.

Evaluation of Low-temperature Thermal Pre-treatment and Biogas Characteristics using Waste Activated Sludge (잉여슬러지를 이용한 저온 열적전처리 및 바이오 가스 특성 평가)

  • Choi, Jae-Hoon;Jeong, Seong-Yeob;Kim, Ji-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.4
    • /
    • pp.299-307
    • /
    • 2019
  • The purpose of this study was to investigate the effect of low temperature thermal pre-treatment on biodegradation of waste activated sludge for anaerobic digestion as a countermeasure for increasing sludge generation. The experimental condition was accomplished in 2 %, 4 %, and 6 % TS concentration, and $70^{\circ}C$, $80^{\circ}C$, $90^{\circ}C$ of temperature for a maximum of 120 minutes retention time. Then, it was followed by analysis of physical/chemical properties, BMP test and composition of biogas. The biogas characteristic was evaluated by applying the modified Gomperz model. As a result, solubility of dissolved substrate, such as $SCOD_{Cr}$, soluble carbohydrate, and soluble protein, and biogas production increased as temperature increased. Solubilization efficiency at $90^{\circ}C$ was 18.4 %, 17.03 % and 16.88% in 2 %, 4 %, and 6 % TS concentration respectively. Also, solubilization rates of carbohydrate and protein similarly increased. BMP test results also showed that methane production in excess sludge increased to 0.194, 0.187 and $0.182m^3/kg$ VS. respectively, and lag phase decreased to 0.145, 0.220, 0.351 day due to acceleration of the hydrolysis step. Consequently, low-temperature thermal pre-treatment could increase biodegradability of sludge, positively affecting biogas production and sludge reduction.