Dewaterability Improvement and Volume Reduction of Bio-Solid using Ultrasonic Treatment (Bio-Solid의 탈수성 개선 및 감량화를 위한 초음파 적용)

  • Park, Cheol;Ha, Jun Soo;Kim, Young Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.4019-4023
    • /
    • 2014
  • This study examined the effectiveness of ultrasound on enhancing the dewaterability and volume reduction of bio solids from a waste treatment plant. The test specimen was obtained from a storage tank immediately before the dewatering process at a local treatment plant. The test conditions included the energy levels of ultrasonic waves and treatment time. The tests were undertaken using three types of different treatment processors (7 liter, 1 ton, 7 ton container). The capillary suction time (CST) and the viscosity of sludge, which is one of the influencing factors for dewaterbility, were obtained under various test conditions. The results showed that ultrasound increases the CST of the raw specimens, whereas a significant reduction (20 % of the maximum value) of CST occurred in the sample with ultrasound and flocculent. The decrease in viscosity reached 40 % of the maximum value. A centrifugal test was performed to examine the characteristics of the sludge settlement. The settling rate and time required to reach the final values were both enhanced by the ultrasonic energy. An ultrasonic treatment is potentially useful tool for reducing the amount of released sludge. To examine the possible use of field application, the real scale sonic processor was designed and operated. The results were similar (50 % of the maximum value) to those of laboratory experiments.

Anaerobic Digestion Biochemical Sludge Produced from Municipal Sewage Treatment Process (하수처리시설에서 발생된 약품 잉여슬러지의 혐기성 소화 특성)

  • Cho, Sang Sun;Kang, Ho;Lim, Bong Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.561-569
    • /
    • 2014
  • This study was carried out to get the characteristics of anaerobic digestion for chemical/biological sludge produced from municipal sewage treatment plant for phosphorus. Anaerobic mesophilic batch tests showed that the ultimate biodegradability of waste activated sludge showed 31%, PACl sludge 24%, Alum sludge 26%, respectively. At the S/I 1.0, 75% of total biodegradable volatile solids (TBVS) of waste activated sludge was degraded with an initial rapid decay coefficient, k1 of $0.1129day^{-1}$ and 74% of TBVS of PACl sludge with k1 of $0.0998day^{-1}$, and 76% of TBVS of Alum sludge with k1 of $0.1091day^{-1}$ for 20 days. During the operation of SCFMRs, the 3 reactor (Control, PACl, Alum) pH maintained 6.7~7.0 and the reactor alkalinity maintained 1,800~ 2,200 mg/L as $CaCO_3$. The average biogas production rates of SCFMRs fed with PACl sludge and Alum sludge were 0.089 v/v-d and 0.091 v/v-d, respectively, which was 27~28% lower than that of the control (0.124 v/v-d) at an HRT (hydraulic retention times) of 20 days. And the methane content during the operation ranged 70~76% in 3 reactor. The average TVS removal efficiency of SCFMRs fed with PACl sludge and Alum sludge were 19.6% and 19.9%, respectively, at an HRT of 20 days, which showed 4% lower than that of the control (23.8%). The average BVS removal efficiency of SCFMRs fed with PACl sludge and Alum sludge were 25.8% and 26.9%, respectively, at an HRT of 20 days, which was 8~9% lower than that of the control (34.5%).

A Study on the Disintegration of Sewage Sludge using Batch Ultrasonic Pretreatment (회분식 초음파 전처리를 이용한 하수슬러지의 분해에 관한 연구)

  • Ko, Hyun-Woong;Jung, Byung-Gil;Jung, Yon-Hwa;Kim, Hyeung-Seok;Jang, Seong-Ho;Sung, Nak-Chang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.4
    • /
    • pp.121-129
    • /
    • 2004
  • Anaerobic digestion is the most common process for sewage sludge stabilization and has benefits of VS reduction and biogas production. Many pretreatment methods have been studied to improve hydrolysis rate because the rate of sewage sludge degradation is slow in anaerobic digestion. This study mainly focused upon the effects on disintegration of sewage sludge by ultrasonic pretreatment according to the variation of acoustic density and duration of sonication time. In this study, acoustic density has been changed as follows : 33W/L, 70W/L, 88W/L, 139W/L in case of 40 kHz with the test time changes of 10min, 20min, 25min, 30min and 40min. In the comparison of $SCOD_{Cr}/TCOD_{Cr}$ variation for excess sludge and mixed sludge disintegration, the rates of $SCOD_{Cr}/TCOD_{Cr}$ have been increased in the condition of denser acoustic density and longer sonication time with acoustic frequency of 40kHz. The pH of the excess sewage sludge and mixed sewage sludge has been decreased in the condition of denser acoustic density and longer sonication time with acoustic frequency of 40kHz.

  • PDF

Application of Non-Thermal Plasma for the Simultaneous Removal of Odor and Sludge (무기악취와 슬러지 동시처리를 위한 저온플라즈마의 적용)

  • Hwang, Hyun-Jung;Ann, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2010
  • In this study, odorous compounds emitted from various wastewater treatment were treated with using the non-thermal plasma reaction, and the effluent gas from the plasma reactor was introduced to a waste sludge reactor to achieve simultaneous sludge reduction. Hydrogen sulfide, the model odorous compound, was removed at 70% using the plasma reaction, and greater than 99% removal efficiency was observed when treated by the sludge reactor. In addition, the sludge reactor showed a high efficiency of ozone removal. As ozone reacted with sludge, oxidation with organic matters took place, and total COD decreased by 50~60% and soluble COD increased gradually. As a result, the integrated process consisting of the non-thermal plasma and the sludge reactor can be successfully applied for the simultaneous treatment of malodorous gas and waste sludge.

Characteristics for Co-digestion of Food Waste and Night Soil using BMP Test (BMP실험을 이용한 음식물폐기물 및 분뇨의 병합소화 특성)

  • Cho, Jinkyu;Kim, Hyungjin;Oh, Daemin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.9
    • /
    • pp.13-18
    • /
    • 2014
  • BMP test was carried out to evaluate the characteristics for co-digestion of night soil and food waste. 6 types of sludge were tested in 30 days which were raw, excess, digested, night soil/septic tank (1:1), food waste (food : dilution water = 1:1), and mixed sludge. Bio gas was produced actively after 2 days, and continued in 2 weeks. Gas generation amount was decreased rapidly after considerable space of time. Especially maximum productivity of gas was shown in 7~8 days. The ultimate methane yields of raw, excess, digested, night soil/septic tank, food waste, and mixed sludge were 64.63, 67.49, 66.45, 72.44, 107.85, and 46.71 mL $CH_4/g$ VS respectively from Modified Gompertz model. The lag growth phase time and maximum specific methane production rate of mixed sludge were 1.88 day and 80.4 mL/day respectively. The methane potential of mixed sludge was higher than individual sludge. So high methane potential was expected by controlling mixing ratio of food waste. Besides stable operation of digestion tank and the solution of oligotrophic problem were possible.

Sewage sludge conditions for promoting solubilization in the ball mill treatment (볼-밀 가용화 효과의 향상을 위한 하수슬러지 조건에 대한 연구)

  • Lee, Myoung Joo;Kim, Tae Hyung;Nam, Yang Won;Hwang, Sun Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.505-510
    • /
    • 2008
  • Excess sludge and raw sludge were treated by ball mill in order to promote solubilization, and it was known that the level of solubilization was higher in excess sludge rather than raw sludge. About solid concentration, with the increase of TS, the amounts of solubilization was increased. And excess sludge was solubilized more effectively with the increase of ball mill treatment time. Especially, in case of excess sludge, within 5 min of ball mill treatment, 6 times of solubilization was achieved compared with raw sludge. The effect of bead size was also tested and 1 mm bead was most desirable when applied to the TS 4% of excess sludge. Particle size decrease by the ball mill treatment was more effective in raw sludge, nevertheless the level of solubilization was always higher in excess sludge. This means that the results of particle analysis could not be understood as a indicator for sludge solubilization. Generally, excess sludge and raw sludge are mixed at the thicker in the STP, but considering a ball mill pretreatment as an alternative for sludge solubilization, it is desirable to treat not raw sludge but excess sludge alone in the aspect of solubilization yield and economical process.

Minimization of Excess Activated Sludge in Nonwoven Fabric Filter Bioreactor (부직포 여과막 생물반응조에서의 폐활성슬러지 감량화)

  • Jung, Kyoung-Eun;Bae, Min-Su;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.88-96
    • /
    • 2006
  • Among the various methods for minimization of waste activated sludge, maintaining a low F/M ratio in the bioreactor is known to be the most effective reliable one. In this research, various experiments were performed to check the capability of the nonwoven fabric filter bioreactor, which has been proved able to maintain a low F/M ratio by maintaining a high MLSS concentration, for excess sludge minimization. The reactor was intermittently fed with a synthetic wastewater having a COD concentration of approximately 300 mg/L and no SS. Results of the experiments showed that the F/M ratio in the reactor decreased to a minimum value of 0.02 g COD/g MLSS-day as the MLSS concentration increased to a maximum value of 31,010 mg/L. However, the measured endogenous decay coefficients and oxygen uptake rates of the MLSS confirmed that the activity of the MLSS decreased as the MLSS concentration increased. Based on the increase of MLSS in the reactor and the mass balance during the whole experimental period, the average microorganism yield coefficients were computed to be low values of 0.148 and 0.139 g MLSS/g COD, respectively. These results indicate that the nonwoven fabric filter bioreactor employed in this research is effective for minimization of excess sludge production.

Evaluation of the Nutrient Removal Performance of the Pilot-scale KNR (Kwon's Nutrient Removal) System with Dual Sludge for Small Sewage Treatment (소규모 하수처리를 위한 파일럿 규모 이중슬러지 KNR® (Kwon's nutrient removal) 시스템의 영얌염류 제거성능 평가)

  • An, Jin-Young;Kwon, Joong-Chun;Kim, Yun-Hak;Jeng, Yoo-Hoon;Kim, Doo-Eon;Ryu, Sun-Ho;Kim, Byung-Woo
    • Clean Technology
    • /
    • v.12 no.2
    • /
    • pp.67-77
    • /
    • 2006
  • A simple dual sludge process, called as $KNR^{(R)}$ (Kwon's Nutrient Removal) system, was developed for small sewage treatment. It is a hybrid system that consists of an UMBR (Upflow multi-layer bioreactor) as anaerobic and anoxic reactor with suspended denitrifier and a post aerobic biofilm reactor, filled with pellet-like media, with attached nitrifier. To evaluate the stability and performance of this system for small sewage treatment, the pilot-scale $KNR^{(R)}$ plant with a treatment capacity of $50m^3/d$ was practically applied to the actual sewage treatment plant, which was under retrofit construction during pilot plant operation, with a capacity of $50m^3/d$ in a small rural community. The HRTs of a UMBR and a post aerobic biofilm reactor were about 4.7 h and 7.2 h, respectively. The temperature in the reactor varied from $18.1^{\circ}C$ to $28.1^{\circ}C$. The pilot plant showed stable performance even though the pilot plant had been the severe fluctuation of influent flow rate and BOD/N ratio. During a whole period of this study, average concentrations of $COD_{cr}$, $COD_{Mn}$, $BOD_5$, TN, and TP in the final effluent obtained from this system were 11.0 mg/L, 8.8 mg/L, 4.2 mg/L, 3.5 mg/L, 9.8 mg/L, and 0.87/0.17 mg/L (with/without poly aluminium chloride(PAC)), which corresponded to a removal efficiency of 95.3%, 87.6%, 96.3%, 96.5%, 68.2%, and 55.4/90.3%, respectively. Excess sludge production rates were $0.026kg-DS/m^3$-sewage and 0.220 kg-DS/kg-BOD lower 1.9 to 3.8 times than those in activated sludge based system such as $A_2O$ and Bardenpho.

  • PDF

Development of airflow control technology for Korean-type bioreactor based on influent water quality (유입수질 기반 한국형 생물반응조 송풍량 제어 기술 개발)

  • Yeo, Wooseok;Woo, Jea Suk;Song, Dong Hoon;Shin, Sung Bok;Kim, Jong Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.388-388
    • /
    • 2022
  • 하수처리 공정 중 생물반응조에서는 미생물의 산화 반응을 통해 하수 내 각종 유기물들을 처리하고 있다. 블로워는 호기조를 유리산소상태로 만들어 미생물들의 유기물 제어, 질산화가 원활하게 이루어질 수 있도록 지원하는 역할을 담당하고 있다. 그러나 실제 하수처리장에서는 유기물을 원활하게 처리하기 위하여 과도하게 블로워를 가동하고 있어 경제적인 측면에서 문제를 겪고 있다. 블로워를 통해 수중에 산소를 부족하게 공급할 경우 활성슬러지의 침전성이 저해되어 방류수 수질이 저해되는 반면, 용존산소가 과도하게 공급되어도 유기물질의 처리 효율은 증대되지 않으며 잉여용존산소는 대기 중으로 방류된다. 이러한 이유로 국내 하수처리장에서는 강화된 방류수 수질 기준을 만족하기 하고자 유입수질에 관계없이 과도하게 송풍기를 운영하고 있다. 이러한 하수처리장의 운영 및 경제적인 문제점을 해결하고자, 본 연구에서는 하수처리장으로 유입되는 원수의 수질을 처리하는 데 실제로 미생물이 필요한 산소요구량 및 공기공급량을 산정하는 프로그램을 개발하였다. 이를 통해 실제 하수처리장에서 필요한 산소요구량, 공기공급량을 산출하여 효율적인 하수처리장 운영이 가능하다. 실제 하수처리장에서의 프로그램을 통한 송풍량 절감 효율을 분석하고자 한 달간의 A 하수처리장 수질 데이터를 기반으로 하수처리에 필요한 산소요구량 및 공기공급량을 산정하였다. 실험 결과 프로그램 적용시 약 평균적으로 10%의 송풍량을 절감이 가능하며, 연구 결과를 바탕으로 효율적이고 경제적인 송풍기 운영조건의 기준을 제시하고자 한다.

  • PDF

A Study on the Optimum Design of Multiple Screw Type Dryer for Treatment of Sewage Sludge (하수슬러지 처리를 위한 다축 스크류 난류 접촉식 건조기의 최적 설계 연구)

  • Na, En-Soo;Shin, Sung-Soo;Shin, Mi-Soo;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.223-231
    • /
    • 2012
  • The purpose of this study is to investigate basically the mechanism of heat transfer by the resolution of complex fluid flow inside a sophisticated designed screw dryer for the treatment of sewage sludge by using numerical analysis and experimental study. By doing this, the result was quite helpful to obtain the design criteria for enhancing drying efficiency, thereby achieving the optimal design of a multiple screw type dryer for treating inorganic and organic sludge wastes. One notable design feature of the dryer was to bypass a certain of fraction of the hot combustion gases into the bottom of the screw cylinder, by the fluid flow induction, across the delicately designed holes on the screw surface to agitate internally the sticky sludges. This offers many benefits not only in the enhancement of thermal efficiency even for the high viscosity material but also greater flexibility in the application of system design and operation. However, one careful precaution was made in operation in that when distributing the hot flue gas over the lump of sludge for internal agitation not to make any pore blocking and to avoid too much pressure drop caused by inertial resistance across the lump of sludge. The optimal retention time for rotating the screw at 1 rpm in order to treat 200 kg/hr of sewage sludge was determined empirically about 100 minutes. The corresponding optimal heat source was found to be 150,000 kcal/hr. A series of numerical calculation is performed to resolve flow characteristics in order to assist in the system design as function of important system and operational variables. The numerical calculation is successfully evaluated against experimental temperature profile and flow field characteristics. In general, the calculation results are physically reasonable and consistent in parametric study. In further studies, more quantitative data analyses such as pressure drop across the type and loading of drying sludge will be made for the system evaluation in experiment and calculation.