• Title/Summary/Keyword: 입자 발생기

Search Result 407, Processing Time 0.028 seconds

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Study on the non-point source control and treatment by vegetation zone (식생대에 따른 비점오염원 관리 및 처리 연구)

  • Choi, I-Song;Kim, Sung-Won;Kim, Soeg-Ku;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.483-487
    • /
    • 2006
  • 본 연구는 비점오염원에 의한 수질오염현상을 억제하기 위한 수변지역의 관리기법 중 하나인 식생여과대를 효과적으로 설치하기 위하여 식생에 의한 오염물질의 저감능력을 파악하고 효율적 설치방안을 모색하기 위하여 수행되었다. 연구결과 T-N과 T-P의 깊이별 오염물질 저감효과는 나대지에서 표면유출이 각각 17.6%, -23.9%, 단면유출이 각각 51.7%, 91.0%, 하부유출이 각각 38.4%, 89.3%인 것으로 나타나 표면층을 통한 유출보다는 토양층에 침투될수록 오염물질의 저감효과가 높아지는 것으로 나타났다. 잔디로 표면층을 식재한 실험에서는 표면, 단면, 하부유출에서의 T-N이 각각 16.0%, 57.1%, 38.4%의 오염물질 저감효과를 보였고, T-P의 저감효과는 각각 -9.7%, 83.6%, 88.8%인 것으로 조사되었다. 또한 돌미나리로 표면층을 식재한 실험에서는 표면, 단면, 하부유출에서의 T-N 처리효율이 각각 -2.6%, 62.1%, 71.2%로 나타났으며, T-P는 각각 -7.2%, 94.5%, 84.5%인 것으로 조사되었다. 결론적으로 식생을 한 경우 전체적으로 오염물질의 저감효율이 비교적 안정되게 유지되는 것으로 나타났으나, T-P의 표면층을 제외하면 전체적인 저감효과에 크게 영향을 미치지 않은 것으로 판단된다. 그러나 일반적으로 알려져 있는 식생에 따른 오염물 저감효과에 대한 순기능 즉 토양입자의 침식방지, 토양용액의 저류작용 및 공극확대에 따른 침투능력 증대, 토성의 개량 등과 같은 기능을 무시할 수 없으므로 오염저감효과를 극대화하기 위해서는 처리대상이 되는 하천유역의 자생적 식생을 보다 효과적으로 활용할 수 있는 방안마련이 비용적 측면이나 생태 보존적 측면에서 유리할 것으로 판단된다.one)을 설치하는 대책이 필요하다. 저수지 관리를 효과적으로 수행하기 위해서는 저수지 내부의 탁도 거동을 정확히 예측할 수 있어야 한다. 따라서 추후 동수역학 및 열역학에 기초한 3차원 수치모형 연구와 성층흐름에 정밀한 밀도류 실험연구 및 이에 대한 적용이 필요할 것으로 판단된다.함으로써 정보의 질적보장과 정보전환의 표준화방안을 제시하는 정보분석시스템이다.이용, 수자원의 지속적 확보기술의 특성에 따른 4개의 평가기준과 26개의 평가속성으로 이루어진 2단계 기술가치평가 모형을 구축하였으며 2개의 개별기술에 대한 시범적용을 실행하였다.하는 것으로 추정되었다.면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였

  • PDF

Distribution of $^{222}Rn$ Concentration in Seoul Subway Stations (서울지역 지하철역의 라돈농도 분포 특성)

  • Jeon, Jae-Sik;Kim, Dok-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.588-595
    • /
    • 2006
  • Indoor radon($^{222}Rn$) concentrations of subway stations in Seoul area were measured to survey the environmental indoor radon levels and to identify sources of radon. The radon concentration of indoor air by method of long-term measuring with a-track detector were surveyed at 232 subway stations from 1998 to 2004. And the radon concentration in ground-water was measured with a method of alpha particle counting. To trace main source of radon, 8 out of 232 stations were selected and their radon concentrations in tunnel and on platform were analyzed. Total geometric mean and arithmetic mean of radon concentrations in all stations from 1998 to 2004 were $1.40{\pm}1.94pCi/L,\;1.65{\pm}1.07$ respectively. Geometric means of radon concentrations on platform and concourse were $1.54{\pm}1.96pCi/L,\;1.23{\pm}1.88pCi/L$ respectively, with higher concentration at the platform than at the concourse. The geological structure was significantly correlated to the indoor radon concentration in subway stations region. Radon concentrations of adjacent tunnel and ground-water of subway station was significantly correlated to the indoor radon concentration in subway stations. And There was a significant difference in radon concentration, depending on the depth levels in platform of subway stations(p<0.05).

자동차 배출가스 규제 및 대책

  • 조병환
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.8-15
    • /
    • 1983
  • 1960년초 이래 우리나라는 고도의 경제성장을 이룩하게 되었으며 이러한 경제성장에 따른 산업화 사회의 특징인 공업화 도시화 인구집중 현상은 우리나라에도 심각한 환경오염 문제를 야기시켜 왔다. 또한 같은 기간동안 자동차의 보유대수 역시 급격한 증가를 보여왔던바, 1962년 30,000 대에서 1982년도 자동차 등록대수는 약 640,000대로 증가하게 되었으며 대부분의 자동차가 대 도시에 집중되어 있다. 특히 전체 차량의 40%가 집중되어 있는 서울시의 경우에는 자동차 배 출가스로 인한 대기오염문제가 도시민의 건강과 재산에 많은 피해를 일으키게 되었다. 우리나 라는 선진 외국의 대도시에 비해 자동차의 1일 주행거리가 3배 내지 5배를 더 주행하고 있고 자동차 배출가스 기준의 완화, 노후차량의 증가, 도로율의 불황 및 도로조건의 불비 등은 도시 중심천의 자동차 집중현상과 함께 자동차 배출가스로 인한 대기오염 문제가 보다 더 심각하게 우려되었고, 따라서 자동차 배출가스규제 강화의 필연성이 계속해서 주장되어 왔다. 자동차로 인한 공해문제는 1940년도 후반 미국 남부 California 지방에서 광화학스모그의 발생과 함께 거 론되기 시작하였으나 본격적으로 문제가 제기된 것은 급격한 자동차 증가로 인한 도시민의 건 강피해가 발생하기 시작한 것은 1960년대이다. 처음으로 규제되기 시작한 것은 1965년 미국에서 "자동차 오염방지법"의 제정부터이며 1968년부터 자동차 배출가스에 대한 규제가 시작되었다. 한편 일본은 1973년, 유럽에서는 1975년부터 일산화탄소, 탄화수소, 질소산화물 및 매연에 대한 규제를 시작하게 되었다. 우리나라에서는 "도로운송차량법"에서 도로교통의 안전과 질서유지라는 측면에서 일부 규제하여 오다가 1977년말 "환경보전법"이 제정 공포되면서 1980년 1월 환경정의 발족과 함께 실제로 자동차 배출가스를 규제하게 되었다.발족과 함께 실제로 자동차 배출가스를 규제하게 되었다.을 SUP7H종으로 더욱 향상된 것이 실용 화되고 있다. 아래에서 이에 대한 기계적 특성을 중심으로 검토키로 한다.9%내인 0.07cm 정도였으나 1973년과 1974년의 방축년에는 조차 3개 처리구(3.4-5.18cm)에 필적되는 연평균 4.16cm로 나타났다. 5. 전체 시험구로부터으 연평균 토양유실량은 Sharpsburg 점질양토에 대한 S.C.S 한계허용치 10ton/ha/year 이내로 나타났다. 비처리구에서의 토양유실량은 평균 2.56ton/ha/year로 높게 나타난 반면 3개의 서로 다른 추리구인 비수구, 초생수로구 및 Bromegrass구에서는 각각 0.152, 0.192 및 0.290ton/ha/year로 낮은 결과를 가져왔다. 6. 평균 침전량에 대한 L.S.D. 검정 걸과 전시험구중 비처리구가 고도의 유의차를 나타낸 반면 비수구, 초생수로구 및 Bromegrass 목초구 간에는 아무런 유의차가 인정되지 않았다. 7. 농지보전 처리구인 배수구와 초생수로구는 비처리구에 비해 낮은 침두 유출량과 낮은 토양유실량을 나타내었다.구보다 14% 절감되는 것으로 나타났다.작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수록 현저했다. 주상에서 관측된 이러한 특성은 서브스톰 확장기 활동이 자기폭풍의 발달과 밀접한 관계가 있음을 시사한다.se that were all low in two aspects, named "the Nonsignificant group". And the issues were high risk perception in

  • PDF

Energy Usage and Emissions of Air Pollutants in North Korea (북한 에너지 사용과 대기오염물질 배출 현황)

  • Kim, In-Sun;Lee, Ji-Yi;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.3
    • /
    • pp.303-312
    • /
    • 2011
  • Data on the energy usage including biomass, emissions of air pollutants ($SO_x$, $NO_x$, CO), and the air quality in North Korea are analyzed. The energy usage in North Korea has decreased in the 1990s and thus, the emission amount of air pollutants. Coal and biomass constitute a major fraction of energy sources since the 1990s. It is identified that the emission amount of air pollutants per unit energy consumption in North Korea is much higher than South Korea for the period data are available (since 1990) implying that the air pollutant emission management system in North Korea is inadequate. In particular, the amount of biomass burning for household cooking and heating is significant with the huge emissions of air pollutants such as CO and organic species both in the gas and aerosol phase. Furthermore, it is found that the existing energy usage and air pollutant emission data are not consistent in biomass burning related data.

Fabrication and analysis of $1.3\mum$ spot-size-converter integrated laser diodes (광모드변환기가 집적된 $1.3\mum$ SC-FP-LD 제작 및 특성 해석)

  • 심종인
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.271-278
    • /
    • 2000
  • We have fabricated and analyzed the lasing characteristics of 1.3$\mu\textrm{m}$ Spot-Size-Converter (SSC) integrated Fabry-Perot (FP) laser diodes, which are very promising light sources for optical subscriber networks. SSC-LDs has been developed by BIB (buttjoint-built-in) coupling and selective MOVPE growth. High-performances were achieved such as the slope efficiency from the SSC facet of 0.23-0.32 mW/mA, the full-width at the half maximum of the far-field pattern (FFP) of 9.5$^{\circ}$~12.3$^{\circ}$, the alignment tolerances of $\pm$2.3$\mu\textrm{m}$ and $\pm$2.5$\mu\textrm{m}$ within the extra-coupling loss of 1 dB for the vertical and parallel directions, respectively. These experimental results were compared to theoretical ones in order to clarify the operational problems and give a good design direction of the fabricated SSC-LDs. It was revealed that an asymmetric output power from the facets, an irrelevancy of FFP and the waveguide structure around SSC facet region, and a poor temperature characteristics were originated from the scattering in the BIB and SSC sections and SHB effect in the active section for the first time.t time.

  • PDF

Removal of Nitrate Nitrogen for Batch Reactor by ZVI Bipolar Packed Bed Electrolytic Cell (영가철 충진 회분식 복극전해조에 의한 질산성 질소 제거)

  • Jeong, Joo Young;Park, Jeong Ho;Choi, Won Ho;Park, Joo Yang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2B
    • /
    • pp.187-192
    • /
    • 2011
  • Nitrate nitrogen is common contaminant in groundwater aquifers, its concentration is regulated many countries below 10 mg/L as N (As per WHO standards) in drinking water. An attempt was made to get optimal results for the treatment of nitrate nitrogen in groundwater by conducting various experiments by changing the experimental conditions for ZVI bipolar packed bed electrolytic cell. From the experimental results it is evident that the nitrate nitrogen removal is more effective when the reactor conditions are maintained in acidic range but when the acidic environment changes to alkaline due to the hydroxide formed during the process of ammonia nitrogen there by increasing the pH reducing the hydrogen ions required for reduction which leads to low effectiveness of the system. In the ZVI bipolar packed bed electrolytic cell, the packing ratio of 0.5~1:1 was found to be most effective for the treatment of nitrate nitrogen because ZVI particles are isolated and individual particle act like small electrode with low packing ratio. It is seen that formation of precipitate and acceleration of clogging incrementally for packing ratio more than 2:1, decreasing the nitrate nitrogen removal rate. When the voltage is increased it is seen that kinetics and current also increases but at the same time more electric power is consumed. In this experiment, the optimum voltage was determined to be 50V. At that time, nitrate nitrogen was removed by 94.9%.

Analysis of Soil Characteristics and its Relationship According to the Geological Condition in Natural Slopes of the Landslide Area (산사태지역 자연사면의 지질별 토질특성 및 상관관계 분석)

  • Kim, Kyeong-Su
    • The Journal of Engineering Geology
    • /
    • v.17 no.2 s.52
    • /
    • pp.205-215
    • /
    • 2007
  • In this study, the soil characteristics are analyzed using the result of various soil tests as an object of the soil layer of natural slopes in landslides areas. Also, the relationship with landslides and interrelation with each soil properties are analyzed. The landslides in three areas with different geological condition are occurred due to heavy rainfall in same time. The geology of Jangheung area, Sangju area and Pohang area is gneiss, granite, and the tertiary sedimentary rock, respectively. However soil characteristics have a little differentiation to geological condition, the soils sampled from landslide area have higher proportion of fine particle and porosity, and lower density than those from non landslide area. In case of same geological condition, landslides are occurred in the terrain slope with high permeability. The permeability is mainly influenced by the soil characteristics such as particle size distribution, porosity, particle structure, and the geological origins such as weathering, sedimentary environment. The soil layer with high internal friction angle is more stable than that with low internal friction angle in all geological condition. The permeability is mainly influenced by effective particle size, coefficient of uniformity, coefficient of gradation, porosity, density and so on. Also, those have interrelation with each factor. These interrelations are similar in all study area. Meanwhile, in proportion as the void ratio and the porosity rises the permeability increases.

Clogging Potential in Constructed Vertical Flow Wetlands Employing Different Filter Materials for First-flush Urban Stormwater Runoff Treatment (도시 초기 강우유출수 처리를 위한 수직흐름습지에서 여재별 폐색 잠재성 분석)

  • Chen, Yaoping;Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.235-242
    • /
    • 2018
  • The function of vertical subsurface flow wetlands can potentially be reduced with time due to clogging and are often assumed to be occurring when ponding and overflow is observed during rainfall. To investigate their clogging potential, three pilot-scale vertical subsurface flow (VSF) wetland systems were constructed employing woodchip, pumice, and volcanic gravel as main media. The systems received stormwater runoff from a highway bridge for seven months, after which the media were taken out and divided into layers to determine the amount and characteristics of the accumulated clogging matters. Findings revealed that the main clogging mechanism was the deposition of suspended solids. This is followed by the growth of biofilm in the media which is more evident in the wetland employing woodchip. Up to more than 30% of the clogging matter were found in the upper 20 cm of the media suggesting that this layer will need replacement once clogging occurs. Moreover, no signs of clogging were observed in all the wetlands during the operation period even though an estimation of at least 2 months without clogging was calculated. This was attributed to the intermittent loading mode of operation that gave way for the decomposition of organic matters during the resting period and potentially restored the pore volume.

An Experimental Study on the Energy Separation of the $100Nm^3$/hr Vortex Tube for $CO_2$ Absorption ($CO_2$ 흡수용 $100Nm^3$/hr급 Vortex Tube의 에너지분리 특성에 관한 실험적 연구)

  • Kim, Chang-Su;Han, Keun-Hee;Park, Sung-Young
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.213-219
    • /
    • 2010
  • Vortex tube is the device that can separate small particles from the compressed gas, as well as compressed gas into hot and cold gas. Due to energy and particle separation ability, a vortex tube can be used as the main component of the $CO_2$ absorption device. In this study, experimental approach has been performed to analyze the energy separation characteristics of the vortex tube. To obtain the preliminary design data, energy separation characteristics of the vortex tube has been tested for orifice diameter, nozzle area ratio, and tube length. As a result, the orifice diameter is the major factor of the vortex tube design. The nozzle area ratio and tube length have a minor effect on the energy separation performance. For Dc=0.6D, AR=0.14~0.16, and L=16D, maximum energy separation has been occurred. The result from this study can be used as the basic design data of the $100Nm^3$/hr class vortex tube applied to the $CO_2$ absorption device. Compared with the $CO_2$ absorption process containing an absorption tower, the process with a vortex tube is expected to have a huge advantage of saving the installation space and the operating cost.