• Title/Summary/Keyword: 입자 가시화

Search Result 291, Processing Time 0.027 seconds

Digital image processing techniques of digital holographic PTV measurement (디지털 holographic PTV 측정을 위한 디지털 영상처리기법에 관한 연구)

  • Kim, Seok;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.1-5
    • /
    • 2005
  • The digital HPTV velocity field measurement consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the velocity extraction process, we improved PTV algorithm to extract the displacement of particle each placed in 3D space. Because a digital recording device was used, some factors such as a spatial resolution, numerical aperture, and particle concentration can affect the performance of the digital HPTV. Especially, a particle concentration ($C_{o}$) affected tile reconstruction efficiency in numerical reconstruction and particle extraction process. In this paper, the reconstruction efficiency was analyzed experimentally with different particle concentration. Optimal reconstruction efficiency was shown in the range of $C_{o}$=$13\∼15$ particles/$mm^{3}$.

  • PDF

Characteristics of Particle Laden Flows in Circular Microchannels (원형 마이크로채널 내의 입자가 부유된 유동의 특성)

  • Kim Y.W.;Jin S.W.;Yoo J.Y.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.85-88
    • /
    • 2005
  • Experimental study has been conducted to evaluate characteristics of particle laden flows at the ratio of channel diameter to particle diameter (B = 14.9, 21.6 and 55). Particle velocities and radial concentrations are obtained using a microscope Nd:YAG laser and cooled CCD camera. Results show that there are relative velocities between the fluid and the particles at B = 14.9. It is also observed that the particles are accumulated at r=$0.5\∼0.82R$, with R being tile tube radius, and particle migration occurs at small Reynolds number, by comparing with the results obtained in macro scale. This gives optimal factors for designing microfluidic channels for cell or Particle separation, particle focusing, and so on.

  • PDF

Particle Trajectory Visualization in Electrostatic Precipitator (정전집진기내의 입자궤적 가시화)

  • 박석주;김상수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3270-3275
    • /
    • 1994
  • Particle trajectory visualization using laser sheet was performed to investigate the corona wind flow interactions in the one-wire and two-wire type electrostatic precipitators. The corona wind generated by corona discharge was not negligible, and strong flow interactions took place owing to the induced circulatory cells. In the case of one-wire type, as the applied voltage was increased and the cross-section mean velocity was decreased, the effect of corona wind became active. In the case of two-wire type, if upstream discharge voltage was relatively higher than downstream discharge voltage, the effect of upstream corona wind was reduced.

Flow Visualization around the Endothelial Cell Model by the PIV System (입자영상유속계를 이용한 혈관내피세포 모형 주위의 유동가시화)

  • Roh, Hyung-Woon;Suh, Sang-Ho;Yoo, Sang-Sin
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.381-384
    • /
    • 2000
  • Relationships between biochemical phenomena and hemodynamics on human endothelial cells are very important to study the mechanism of atherosclerotic formation and development. The objective of this study is to investigate the flow phenomena around the endothelial cell model by the PIV experiment. The microscopic images of endothelial cells were acquired by a CCD camera to fabricate the shape of endothelial cell. The cell models were fabricated by using a photoforming process. Two consecutive particle images were captured by the CCD camera for the image processing. Conifer powder as the tracing particles was added to water to visualize the flow field. The cross-correlation method was applied fer the image processing of the flow visualization. Pressure and wall shear stress variations on the surfaces of the endothelial cells were calculated to investigate the effects of hemodynamic forces on the morphological changes.

  • PDF

Particle Separator using Radiation Force (광력을 이용한 입자 분리 장치)

  • Kim, Sang-Bok;Yoon, Sang-Youl;Kim, Sang-Soo;Sung, Hyung-Jin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.55-58
    • /
    • 2007
  • To improve the conventional optical chromatography, the continuous particle separator, the cross-type optical chromatography, is fabricated using micro-channel and fiber optics. A laser beam irradiates into the liquid solution containing particles in the perpendicular to the liquid flow direction. The different sized polystyrene latex micro-spheres, $2.0\;{\mu}m\;{\pm}\;0.02\;{\mu}m$, $5.0\;{\mu}m\;{\pm}\;0.05\;{\mu}m$, and $10.0\;{\mu}m\;{\pm}\;0.09\;{\mu}m$ diameter, are separated in cross-type optical chromatography. The separated particles are delivered to down stream in the micro-channel maintaining the retention distance continuously. The measured retention distances for different sized particles well agree with theoretical predictions.

  • PDF

Study of Incipient Soot Particles with Measuring Methodologies (입자 측정방법을 통한 초기 수트입자 연구)

  • Lee Eui Ju
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.12-17
    • /
    • 2004
  • The physical characteristics of soot near the soot inception point were investigated with various measurements. In-situ measurements of particle size and volume fraction were introduced based on time resolved laser-induced incandescence (TIRE-LII) and laser-induced ion mobility (LIIM). The one has more convenience and accuracy than conventional LII technique and the other works best for particle sizes of a few nanometers at high concentrations in a uniform concentration field. A complementary ex-situ measurement of particle size is nano differential mobility analyzer (Nano-DMA), which recently developed for measuring particle sizes between 2nm and 100nm and provides high-resolution size information for early soot. Particles will be also collected on transmission electron microscope (TEM) grids using rapid thermophoretic sampling and analyzed for morphology. These measurements will allow fresh and original insight into the characterizing soot inception process. The measured physical properties of incipient soot will clarify the controlling growth mechanism combined with chemical ones, and the dominant mechanism for soot modeling can be deduced from the information.

  • PDF

Precise Estimations on Vorticities using a Hybrid PTV-PIV Algorithm (하이브리드 PTV-PIV알고리듬에 의한 고정밀 와도 추정)

  • Doh, Deog-Hee;Cho, Gyong-Rae;Lee, Jae-Min
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.26-30
    • /
    • 2010
  • A PTV algorithm was constructed using a linear transformation, in which the merits of the conventional PIV and PTV were adopted. In PIV calculations, the obtained velocity vectors are affected by the filtering effects by its calculation principle. PTV techniques are widely used for their excellences of measuring small scaled flows, such as nano and bio flows. However, PTVs produce vector errors due to interpolation process. To overcome these problems, a hybrid PTV algorithm was constructed by combining PTVs' and PIVs' benefits using a linear transformation. The Taylor-Green vortex flows were generated for the tests of vorticity calculations. The conventional gray-level cross-correlation PIV technique and 2-Frame PTV technique were tested for the same flows for comparisons with those obtained by the constructed hybrid algorithm. The excellence of the constructed hybrid algorithm was validated through an actual experiment on the cylinder wake.

Dynamic Stability of Particle-Lattice Structures Simulating Swarms in Turbulence (군집을 모사한 입자-격자 구조의 난류 내 동적 안정성)

  • Oh, Jeong Suk;Yoon, Sung Gun;Park, Han June;Hwang, Wontae
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.3
    • /
    • pp.32-38
    • /
    • 2019
  • The dynamic stability of swarms is crucial in preventing collisions in clustered flights and safely moving along a defined path. Although there have been many simulation studies on dynamic stability, there have not been many experimental studies using real clusters due to the difficulty in implementation. In this study, we constructed a particle-lattice structure simulating bird flocks or drone swarms, and conducted experiments within turbulent flow. We identified a criterion that describes dynamically stable particle-lattice structures. The stability increased as this newly defined spatial index increased.

Study on Temperature Field Measurement of Fluid using Phophor Particle (Sr,Mg)2SiO4:Eu2+ (인광입자(Sr,Mg)2SiO4:Eu2+를 이용한 액체의 온도장 측정에 관한 연구)

  • Song, Dong Jin;Lee, Hyunchang
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.3
    • /
    • pp.59-65
    • /
    • 2019
  • Phosphor particles ((Sr,Mg)2 SiO4:Eu2+ were suspended in deionized water in quartz cuvette and used for measuring liquid temperature field by using two-color-ratio method. In the temperature range of 23~77℃, it showed the relative error from 2.4% to 4% and the temperature sensitivity of 0.65 %/℃ at 30℃ and 0.95 %/℃ at 77 ℃. This performance is comparable to measurement techniques using thermographic liquid crystal or laser induced fluorescence or other thermographic phosphor particle. Among investigated potential error sources, the particle number density affected the intensity ratio and the temperature, but the effect of laser fluence was not evident.

Measurements of a Ship's Propeller Wake with Stereoscopic-PIV and Stereoscopic-PTV (스테레오 PTV와 스테레오 PIV에 의한 선박프로펠러 후류측정)

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.26-32
    • /
    • 2007
  • Stereoscopic PTV and Stereoscopic-PIV measurements have been carried out for the studies of the wake of a ship's propeller. Stereoscopic photogrammetry based on a 3D-PTV principle was introduced using two high-definition cameras(1k x 1k, 30Hz). The arrangement of the two cameras was based on angular position. The pair-matching of the three-dimensional velocity vectors were based on Genetic Algorithm based 3D-PTV technique. The results obtained by both measurement systems have been compared at the advance ratio J=0.88(290 rpm, d=54 mm). Turbulent properties have also been compared each other at the same condition.